大型运载火箭重量特性快速测量技术研究
1
作者 JIAO Zhen DING Yifan +3 位作者 HUANG Shuai XIANG Changzheng LI Wenjie QIAO Fan 《Aerospace China》 2023年第2期15-20,共6页
In order to further adapt to the task requirements for rapid testing and high-density launches,the LM-5 series of rocket boosters have adopted an automated acquisition and measurement process for key parameters such a... In order to further adapt to the task requirements for rapid testing and high-density launches,the LM-5 series of rocket boosters have adopted an automated acquisition and measurement process for key parameters such as the weight and centroid of the launch vehicle.A fully automatic rapid measurement technology for the weight characteristics of the rocket,consisting of a measurement system,a control system,an execution system,and a data processing system,has been developed and incorporated.This does not just achieve the adjustment of the overall assembly attitude of the rocket body and the measurement of the center of mass,but also greatly reduces the workload in the traditional measurement operations such as for assembly erection and rail transfer.Thus improving the general convenience,while greatly improving the reliability and measurement accuracy of product installation,which further promotes the popularization of an intelligent measurement technology application. 展开更多
关键词 INTELLIGENCE AUTOMATION rapid measurement technology weight characteristics
下载PDF
Fast-Response Fiber-Optic FPI Temperature Sensing System Based on Modulated Grating Y-Branch Tunable Laser
2
作者 Yang CHEUNG Zhenguo JING +6 位作者 Qiang LIU Ang LI Yueying LIU Yihang GUO Sen ZHANG Dapeng ZHOU Wei PENG 《Photonic Sensors》 SCIE EI CSCD 2024年第1期59-72,共14页
In this paper,a cost-effective and miniaturized instrument is proposed,which is based on a tunable modulated grating Y-branch(MG-Y)laser for rapid temperature measurement using a Fabry-Perot interferometer(FPI)sensor.... In this paper,a cost-effective and miniaturized instrument is proposed,which is based on a tunable modulated grating Y-branch(MG-Y)laser for rapid temperature measurement using a Fabry-Perot interferometer(FPI)sensor.The FPI sensor with a 1463-μm cavity length is a short segment of a capillary tube sandwiched by two sections of single-mode fibers(SMFs).This system has a broad tunable range(1527 nm-1567 nm)with a wavelength interval of 8 pm and a tuning rate of 100 Hz.Temperature sensing experiments are carried out to investigate the performance of the system by demodulating the absolute cavity length of the FPI sensor using a cross-correlation algorithm.Experimental results show that the sensor can reach the response time as short as 94 ms with the sensitivity of 802 pm/C.Benefiting from the homemade and integrated essential electrical circuits,the entire system has the small size,low cost,and practical application potential to be used in the harsh environment for rapid temperature measurement. 展开更多
关键词 MG-Y laser INTERROGATOR rapid temperature measurement cross-correlation algorithm
原文传递
Rapid dissociation and on-site saturation evaluation of methane hydrate sediment samples for natural gas hydrate exploitation 被引量:1
3
作者 Shuanshi Fan Kai Guo +3 位作者 Yanhong Wang Xuemei Lang Na Wei Qingping Li 《Petroleum》 CSCD 2021年第4期469-476,共8页
Natural gas hydrate is a kind of clean energy with huge reserves,and the saturation(volume percentage of hydrate in pore space of sediments)is the key parameter for determining whether the reservoir is worthy of explo... Natural gas hydrate is a kind of clean energy with huge reserves,and the saturation(volume percentage of hydrate in pore space of sediments)is the key parameter for determining whether the reservoir is worthy of exploitation.In this work,rapid hydrate dissociation by the combination of heat injection and NaCl inhibitor addition was studied,and an on-site evaluation method for hydrate saturation in sediment samples was proposed by using a core sampler to transfer hydrate samples under pressure.The results showed that the average gas production rate per unit volume was increased significantly to reach 7.22 L/Lr$min-1 by the injection of NaCl aqueous solution with 50.9C,which was attributed to the increase of the chemical potential to further accelerate the rate of hydrate dissociation in the presence of NaCl.Furthermore,for the measurement of methane hydrate samples saturation with a volume of 673 cm3(which contained 1.4 mol hydrates with the saturation of 58%),hydrate saturation could be accurately achieved within 30 min with a relative error lower than 11.7%This work may provide new thoughts for on-site saturation evaluation and rapid dissociation of hydrate samples during natural gas hydrate exploitation. 展开更多
关键词 Natural gas hydrate SATURATION rapid on-site measurement NaCl solution rapid dissociation
原文传递