The capacitive reactive power reversal in the urban distribution grid is increasingly prominent at the period of light load in the last years.In severe cases,it will endanger the security and stability of power grid.T...The capacitive reactive power reversal in the urban distribution grid is increasingly prominent at the period of light load in the last years.In severe cases,it will endanger the security and stability of power grid.This paper presents an optimal reactive power compensation method of distribution network to prevent reactive power reverse.Firstly,an integrated reactive power planning(RPP)model with power factor constraints is established.Capacitors and reactors are considered to be installed in the distribution system at the same time.The objective function is the cost minimization of compensation and real power loss with transformers and lines during the planning period.Nodal power factor limits and reactor capacity constraints are new constraints.Then,power factor sensitivity with respect to reactive power is derived.An improved genetic algorithm by power factor sensitivity is used to solve the model.The optimal locations and sizes of reactors and capacitors can avoid reactive power reversal and power factor exceeding the limit.Finally,the effectiveness of the model and algorithm is proven by a typical high-voltage distribution network.展开更多
First, the paper analyzes the advantages and disadvantages of all kinds of reactive power compensation technology, and then proposes a principle and integrated control strategy of the composite operation of TSC and SV...First, the paper analyzes the advantages and disadvantages of all kinds of reactive power compensation technology, and then proposes a principle and integrated control strategy of the composite operation of TSC and SVG, also the paper designs and develops the main controller of Network based composite power quality regulation device, based on RTDS, the real-time digital simulation model of The Device is established, and finally the prototype of the device is developed with the function of filter and split-phase compensation. The main controller determines the cooperative operation of both TSC and SVG, and the switching strategy of TSC. The simulation result in RTDS can verify the precision of the measure system and the validity of the control logic, the prototype has finished the type test according to the national standard.展开更多
在电力行业追求高效、节能的大背景下,低压配电网降损中的无功补偿技术应运而生的。随着电力需求的不断增长,低压配电网的损耗问题日益突出,为提升功率因数、降低线损并改善电网的电压质量,采用静止无功发生器(Static Var Generator,SVG...在电力行业追求高效、节能的大背景下,低压配电网降损中的无功补偿技术应运而生的。随着电力需求的不断增长,低压配电网的损耗问题日益突出,为提升功率因数、降低线损并改善电网的电压质量,采用静止无功发生器(Static Var Generator,SVG)和晶闸管投切电容器(Thyristor Switch Capacitor,TSC)等设备的混合补偿方案,并结合MATLAB仿真模型进行验证。SVG+TSC混合补偿方案进一步提升了电网性能,将电压波动范围降低到±1.5%,线损率降低到2.0%,并减少了350 kvar的无功功率。实验数据充分证明了无功补偿技术在优化电力系统运行、降低能耗方面的显著效果,为企业和区域发展带来了更大的经济效益。展开更多
文摘The capacitive reactive power reversal in the urban distribution grid is increasingly prominent at the period of light load in the last years.In severe cases,it will endanger the security and stability of power grid.This paper presents an optimal reactive power compensation method of distribution network to prevent reactive power reverse.Firstly,an integrated reactive power planning(RPP)model with power factor constraints is established.Capacitors and reactors are considered to be installed in the distribution system at the same time.The objective function is the cost minimization of compensation and real power loss with transformers and lines during the planning period.Nodal power factor limits and reactor capacity constraints are new constraints.Then,power factor sensitivity with respect to reactive power is derived.An improved genetic algorithm by power factor sensitivity is used to solve the model.The optimal locations and sizes of reactors and capacitors can avoid reactive power reversal and power factor exceeding the limit.Finally,the effectiveness of the model and algorithm is proven by a typical high-voltage distribution network.
文摘First, the paper analyzes the advantages and disadvantages of all kinds of reactive power compensation technology, and then proposes a principle and integrated control strategy of the composite operation of TSC and SVG, also the paper designs and develops the main controller of Network based composite power quality regulation device, based on RTDS, the real-time digital simulation model of The Device is established, and finally the prototype of the device is developed with the function of filter and split-phase compensation. The main controller determines the cooperative operation of both TSC and SVG, and the switching strategy of TSC. The simulation result in RTDS can verify the precision of the measure system and the validity of the control logic, the prototype has finished the type test according to the national standard.