期刊文献+
共找到4篇文章
< 1 >
每页显示 20 50 100
Development and Preliminary Application of SYBR Green I Real-Time Fluorescence Quantitative PCR Method for Detecting Porcine Parvovirus Virus
1
作者 SHEN Zhi-qiang WANG Jin-liang +3 位作者 GUO Xian-po WANG Xiao-hu WANG Ming ZHAO De-ming 《Animal Husbandry and Feed Science》 CAS 2009年第11期42-46,共5页
According to VP2 gene sequence of the porcine parvovirus virus strain NADL-2 (NC001718) available in GenBank (NC_001718), a pair of specific primer was designed, and the target fragment of 431 bp was obtained by P... According to VP2 gene sequence of the porcine parvovirus virus strain NADL-2 (NC001718) available in GenBank (NC_001718), a pair of specific primer was designed, and the target fragment of 431 bp was obtained by PCR amplification. The products were ligated with pMD18- T vector and then transformed into bacteria DH5α for recombinant plasmid extraction. After PCR identification and sequencing, recombinant plasmid was used as a standard template to establish the standard curve of SYBR Green I fluorescence quantitative PCR. Sensitivity test, specificity test and repeatability test were also determined. The results indicated that there was a good linear relationship between threshold cycle of the standard curve and template concentration, R2 =0.997 6. Tm ranged from 82.3 to 82.9 ℃, while the sensitivity was 72.1 copies/μl with good specificity and repeatability. The developed SYBR Green I real-time quantitative PCR method to detect PPV VP2 gene laid the basis for further studies on patho- oenesis, early clinical diaonosis of this virus and quantitative analysis of PPV infection. 展开更多
关键词 Porcine parvovirus virus real-time fluorescence quantitative PCR detection
下载PDF
Establishment of a new quantitative detection approach to adefovir-resistant HBV and its clinical application 被引量:5
2
作者 Zhao, Wei-Feng Shao, You-Lin +4 位作者 Chen, Liang-Yun Wu, Jin-Hua Zhu, Yi-Ling Gan, Jian-He Xiong, Hui 《World Journal of Gastroenterology》 SCIE CAS CSCD 2010年第10期1267-1273,共7页
AIM:To establish the more feasible and sensitive assessment approach to the detection of adefovir (ADV) resistance-associated hepatitis B virus (HBV) quasispecies.METHODS: Based on the characteristics of rtA181V/T and... AIM:To establish the more feasible and sensitive assessment approach to the detection of adefovir (ADV) resistance-associated hepatitis B virus (HBV) quasispecies.METHODS: Based on the characteristics of rtA181V/T and rtN236T mutations, a new approach based on real-time fluorescent quantitative polymerase chain reaction (RT-PCR) was established for the detection of ADV-resistant HBV quasispecies, total HBV DNA, rtA181 and rtN236 mutations in blood samples from 32 chronic hepatitis B (CHB) patients with unsatisfactory curative effect on ADV and compared with routine HBV DNA sequencing.RESULTS: Both the sensitivity and specificity of this new detection approach to ADV-resistant HBV quasispecies were 100%, which were much higher than those of direct HBV DNA sequencing. The approach was able to detect 0.1% of mutated strains in a total plasmid population. Among the 32 clinical patients, single rtA181 and rtN236T mutation and double rtA181T and rtN236T mutations were detected in 20 and 8, respectively, while ADV-resistant mutations in 6 (including, rtA181V/T mutation alone in 5 patients) and no associated mutations in 26.CONCLUSION: This new approach is more feasible and efficient to detect ADV-resistant mutants of HBV and ADV-resistant mutations before and during ADV treatment with a specificity of 100% and a sensitivity of 100%. 展开更多
关键词 Chronic hepatitis B ADEFOVIR Drug resistance quantitative detection real-time fluorescent quantitative polymerase chain reaction
下载PDF
Development of real-time PCR method for rapid detection and quantification of Heterosigma akashiwo 被引量:1
3
作者 何闪英 于志刚 米铁柱 《Journal of Harbin Institute of Technology(New Series)》 EI CAS 2008年第1期118-123,共6页
To rapidly detect the harmful algae H.akashiwo qualitatively and quantitatively, sequences of the 18S rDNA deduced from H.akashiwo were used for designing species-specific primers, and a RFQ-PCR (Real-time Fluorescent... To rapidly detect the harmful algae H.akashiwo qualitatively and quantitatively, sequences of the 18S rDNA deduced from H.akashiwo were used for designing species-specific primers, and a RFQ-PCR (Real-time Fluorescent Quantitative Polymerase Chain Reaction) method was developed for quantitative detection of H.akashiwo. Primer H.akashiwo and TaqMan probe were designed, and the specificity of primer was checked with PCR. A calibration curve was constructed with cycle threshold value against visual counted cell number. And the value of the curve was tested with other H.akashiwo samples, which were assayed with both the RFQ-PCR method and visual count under microscope. 展开更多
关键词 Heterosigma akashiwo fluorescent quantitative PCR molecular probe real-time detection
下载PDF
Micro-droplet Digital Polymerase Chain Reaction and Real-Time Quantitative Polymerase Chain Reaction Technologies Provide Highly Sensitive and Accurate Detection of Zika Virus 被引量:7
4
作者 Yuan Hui Zhiming Wu +12 位作者 Zhiran Qin Li Zhu Junhe Liang Xujuan Li Hanmin Fu Shiyu Feng Jianhai Yu Xiaoen He Weizhi Lu Weiwei Xiao Qinghua Wu Bao Zhang Wei Zhao 《Virologica Sinica》 SCIE CAS CSCD 2018年第3期270-277,共8页
The establishment of highly sensitive diagnostic methods is critical in the early diagnosis and control of Zika virus(ZIKV)and in preventing serious neurological complications of ZIKV infection. In this study, we esta... The establishment of highly sensitive diagnostic methods is critical in the early diagnosis and control of Zika virus(ZIKV)and in preventing serious neurological complications of ZIKV infection. In this study, we established micro-droplet digital polymerase chain reaction(ddPCR) and real-time quantitative PCR(RT-qPCR) protocols for the detection of ZIKV based on the amplification of the NS5 gene. For the ZIKV standard plasmid, the RT-qPCR results showed that the cycle threshold(Ct) value was linear from 10~1 to 10~8 copy/l L, with a standard curve R^2 of 0.999 and amplification efficiency of 92.203%;however, a concentration as low as 1 copy/l L could not be detected. In comparison with RT-qPCR, the dd PCR method resulted in a linear range of 10~1–10~4 copy/l L and was able to detect concentrations as low as 1 copy/l L. Thus, for detecting ZIKV from clinical samples, RT-qPCR is a better choice for high-concentration samples(above 10~1 copy/l L),while ddPCR has excellent accuracy and sensitivity for low-concentration samples. These results indicate that the ddPCR method should be of considerable use in the early diagnosis, laboratory study, and monitoring of ZIKV. 展开更多
关键词 Zika virus Nucleic acid detection - Micro-droplet digital polymerase chain reaction (ddPCR)real-time fluorescence quantitative polymerase chain reaction (RT-qPCR)
原文传递