The establishment of highly sensitive diagnostic methods is critical in the early diagnosis and control of Zika virus(ZIKV)and in preventing serious neurological complications of ZIKV infection. In this study, we esta...The establishment of highly sensitive diagnostic methods is critical in the early diagnosis and control of Zika virus(ZIKV)and in preventing serious neurological complications of ZIKV infection. In this study, we established micro-droplet digital polymerase chain reaction(ddPCR) and real-time quantitative PCR(RT-qPCR) protocols for the detection of ZIKV based on the amplification of the NS5 gene. For the ZIKV standard plasmid, the RT-qPCR results showed that the cycle threshold(Ct) value was linear from 10~1 to 10~8 copy/l L, with a standard curve R^2 of 0.999 and amplification efficiency of 92.203%;however, a concentration as low as 1 copy/l L could not be detected. In comparison with RT-qPCR, the dd PCR method resulted in a linear range of 10~1–10~4 copy/l L and was able to detect concentrations as low as 1 copy/l L. Thus, for detecting ZIKV from clinical samples, RT-qPCR is a better choice for high-concentration samples(above 10~1 copy/l L),while ddPCR has excellent accuracy and sensitivity for low-concentration samples. These results indicate that the ddPCR method should be of considerable use in the early diagnosis, laboratory study, and monitoring of ZIKV.展开更多
基金supported by the National Natural Science Foundation of China (Nos. 31470271 and 81730110)Guangzhou Science and Technology Program key projects (No. 201803040006)
文摘The establishment of highly sensitive diagnostic methods is critical in the early diagnosis and control of Zika virus(ZIKV)and in preventing serious neurological complications of ZIKV infection. In this study, we established micro-droplet digital polymerase chain reaction(ddPCR) and real-time quantitative PCR(RT-qPCR) protocols for the detection of ZIKV based on the amplification of the NS5 gene. For the ZIKV standard plasmid, the RT-qPCR results showed that the cycle threshold(Ct) value was linear from 10~1 to 10~8 copy/l L, with a standard curve R^2 of 0.999 and amplification efficiency of 92.203%;however, a concentration as low as 1 copy/l L could not be detected. In comparison with RT-qPCR, the dd PCR method resulted in a linear range of 10~1–10~4 copy/l L and was able to detect concentrations as low as 1 copy/l L. Thus, for detecting ZIKV from clinical samples, RT-qPCR is a better choice for high-concentration samples(above 10~1 copy/l L),while ddPCR has excellent accuracy and sensitivity for low-concentration samples. These results indicate that the ddPCR method should be of considerable use in the early diagnosis, laboratory study, and monitoring of ZIKV.