The present study evaluated the application of three dimensional echocardigraphy (3DE) in the diagnosis of atrial septal defect (ASD) and the measurement of its size by 3DE and compared the size with surgical find...The present study evaluated the application of three dimensional echocardigraphy (3DE) in the diagnosis of atrial septal defect (ASD) and the measurement of its size by 3DE and compared the size with surgical findings. Two-dimensional and real-time three dimensional echocardiography (RT3DE) was performed in 26 patients with atrial septal defect, and the echocardiographic data were compared with the surgical findings. Significant correlation was found between defect diameter by RT3DE and that measured during surgery (r=0.77, P〈0.001). The defect area changed significantly during cardiac cycle. Percentage change in defect size during cardiac cycle ranged from 6%-70%. Our study showed that the size and morphology of atrial septal defect obtained with RT3DE correlate well with surgical findings. Therefore, RT3DE is a feasible and accurate non-invasive imaging tool for assessment of atrial septal size and dynamic changes.展开更多
AIM: To differentiate focal liver lesions based on enhancement patterns using three-dimensional ultrasonography (3D US) with perflubutane-based contrast agent.METHODS: Two hundred and eighty two patients with focal li...AIM: To differentiate focal liver lesions based on enhancement patterns using three-dimensional ultrasonography (3D US) with perflubutane-based contrast agent.METHODS: Two hundred and eighty two patients with focal liver lesions,including 168 hepatocellular carcinomas (HCCs),63 metastases,40 hemangiomas and 11 focal nodular hyperplasias (FNHs),were examined by 3D US with perflubutane-based contrast agent.Tomographic ultrasound images and sonographic angiograms were reconstructed.Among 282 lesions,enhancement patterns of 163 lesions between January 2007 and October 2007 were analyzed retrospectively.Then from November 2007 to May 2008,compared with contrast-enhanced (CE) 2D US,CE 3D US was performed on 119 lesions for prospective differential diagnosis.Sensitivity,specificity,area under receiver operating characteristic curve (Az) and inter-reader agreement were assessed.RESULTS: With the tridimensional view,dominant enhancement patterns were revealed as diffuse enhancement or peripheral ring-like enhancement,followed with washout change for HCCs or metastases,respectively,and peripheral nodular enhancement or diffuse enhancement with spoke-wheel arteries,followed by persistent enhancement for hemangiomas or FNHs,respectively.At CE 3D US,the prospective differentiation of lesions showed sensitivity 92% (mean for two readers),specificity 91% and Az value 0.95 for HCCs,84%,97%,and 0.95 for metastases,91%,98%,and 0.98 for hemangiomas and 80%,99%,and 0.99 for FNHs,respectively,while good to excellent inter-reader agreement was achieved.No significant difference exists between prospective diagnosis accuracy at CE 3D US and that at CE 2D US.CONCLUSION: CE 3D US provides a spatial perspective for liver tumor enhancement,and could help in differentiating focal liver lesions.展开更多
Objective To quantitatively analyze the fetal lung echo and right lung volume in the third trimester by real-time three-dimensional ultrasound(3-D US)and evaluate the feasibility of fetal lung maturity.Methods A total...Objective To quantitatively analyze the fetal lung echo and right lung volume in the third trimester by real-time three-dimensional ultrasound(3-D US)and evaluate the feasibility of fetal lung maturity.Methods A total of 732 women with normal singleton pregnancies between 28 and 42 weeks of gestation underwent ultrasound examination.The 3-D US equipment with a 3.5-5 MHz transabdominal transducer was used for the fetal biometric measurement.The echogenicity ratio between fetal lung and liver was compared.The fetal lung volume was calculated by the rotational multiplanar technique for volume measurement(VOCAL).Results The right fetal lung volume increased with the increase of gestational age with a linear positive correlation(r=0.884,P<0.01).After 34 weeks,the echogenicity ratio of fetal lung to liver was more than 1.1.Conclusion The echogenicity of lung/liver and fetal lung volume could be used as normal fetal predictable indicators for fetal lung maturity.展开更多
To evaluate the clinical value of three dimensional ultrasonography (3DUS) in prenatal diagnosis, 134 pregnant women with high risk factors in second and third trimester were examined by 3DUS. The results showed tha...To evaluate the clinical value of three dimensional ultrasonography (3DUS) in prenatal diagnosis, 134 pregnant women with high risk factors in second and third trimester were examined by 3DUS. The results showed that 3DUS could provide more diagnostic information, exclude the abnormalities and enhance the confidence level of physician in 102 normal pregnant women. 3DUS was helpful in the diagnosis in 17 (60.7 %) of 28 cases of fetal anomalies. However, 3DUS was not useful in evaluating intrauterine growth retardation in 4 cases. It is conclucded that 3DUS is helpful in prenatal diagnosis.展开更多
To investigate the clinical value of three dimensional ultrasonography (3DUS) in obstetrics, various 3DUS rendering methods including surface mode, transparent mode and multiplanar mode were employed to scan 30 fetus...To investigate the clinical value of three dimensional ultrasonography (3DUS) in obstetrics, various 3DUS rendering methods including surface mode, transparent mode and multiplanar mode were employed to scan 30 fetuses in second and third trimester by using the transabdominal volume transducer. The results showed that surface mode could vividly demonstrate the surface morphologic features of the fetuses, as well as the stereo shape and the spatial relationship among the surface structures. The face, limbs, umbilical cord and outer genitalia of the fetus could be well displayed by surface mode. Transparent mode could reveal the bony structures under the surface, such as ribs, vertebrae, crania, etc. The result was not affected by the sophisticated curvature of these bony structures and the success rate was up to 100 %. When rendered by multiplanar mode, the region of interest (ROI) could be viewed from different directions. It should be concluded that 3DUS could serve as a supplement to two dimensional ultrasonography (2DUS). 3DUS might play an important role in prenatal diagnosis and enhance the diagnostic confidence level of the physicians.展开更多
<strong>Objective: </strong>To explore the value of real-time bedside ultrasonography in the etiologic diagnosis of acute dyspnea.<strong> Methods:</strong> Sixty-two patients with acute dyspne...<strong>Objective: </strong>To explore the value of real-time bedside ultrasonography in the etiologic diagnosis of acute dyspnea.<strong> Methods:</strong> Sixty-two patients with acute dyspnea who were treated in our hospital from January 2016 to December 2020 were randomly selected and their clinical data were retrospectively analyzed. All patients were randomly divided into a control group for routine examinations (n = 31) and an observation group for real-time beside ultrasonography (n = 31). The costs of medical examinations, examination duration, and diagnostic results of severe pneumonia, acute cardiogenic pulmonary edema, pulmonary embolism, chronic obstructive pulmonary disease, and pneumothorax (including sensitivity, specificity, positive predictive value, negative predictive value, and diagnostic accuracy) of the two groups of patients were compared and analyzed. <strong>Results:</strong> Compared with the control group, the observation group had significantly shorter examinations (P < 0.05). Although the cost of medical examinations of the observation group tended to be higher, the difference between groups was not significant (P > 0.05). Moreover, there were no significant differences in left ventricular ejection fraction, left ventricular end-diastolic diameter, or brain natriuretic peptide between the two groups (P > 0.05). Comparison of the etiologic diagnosis results between the two groups showed that the observation group had significantly higher diagnostic sensitivity, specificity, positive and negative predictive values, and diagnostic accuracy for various causes compared with the control group (P < 0.05). <strong>Conclusion:</strong> Real-time bedside ultrasonography for the etiologic diagnosis of patients with acute dyspnea was quicker and had higher diagnostic accuracy;thus providing accurate guidance for the disease treatment, and having a higher promotional value in clinical practice compared with routine examinations.展开更多
To investigate the methodology and evaluate the clinical value of surface mode on three- dimensional ultrasonography (3DUS) in static anatomical structures, 62 patients with various diseases were studied. The equipmen...To investigate the methodology and evaluate the clinical value of surface mode on three- dimensional ultrasonography (3DUS) in static anatomical structures, 62 patients with various diseases were studied. The equipment used here was Voluson 530D 3DUS imaging system and 3D volume trahsducer with frequency being 3. 0-5. 0 MHz. The 3DUS rendering method was surface mode. The results showed that: 1 ) Surface mode of 3DUS could demonstrate clearly the anatomical characteristics of the region-of-interest (ROI) and the inner wall of lesions or organs that contained fluid. The anatomic details, such as location, size, shape, and number of the ROI, could be visualized intuitively; 2) The outer anatomic features (e. g. contour, edge, configuration, etc. ) of some organs or lesions surrounded by fluid could be displayed clearly. It could be concluded that surface mode on 3DUS could provide more diagnostic information than two-dimensional ultrasonography (2DUS) in some cases and could served as a beneficial supplement to ZDUS in clinical practice.展开更多
Objectives: To demonstrate the value of 3-dimensional (3-D) ultrasound (US) in the diagnosis of congenital uterine anomalies. Methods: Fifty one infertile patients referred to our US unit during 12 years period, with ...Objectives: To demonstrate the value of 3-dimensional (3-D) ultrasound (US) in the diagnosis of congenital uterine anomalies. Methods: Fifty one infertile patients referred to our US unit during 12 years period, with suspected diagnosis of congenital uterine anomalies by previous HSG or 2D US examinations, were evaluated by transvaginal 3-D US. The 3-D US diagnoses were compared to the initial HSG diagnosis, and to hysteroscopic evaluation when performed. Results: 3-D scan confirmed the initial HSG diagnosis in 27 out of 51 (52.9%) women. The concordancy rates between the initial diagnosis by HSG and 3-D US results were 30.4% for bicornuate uterus;75% for arcuate uterus;83% for septate uterus;and 80% for unicornuate uterus. Of the 13 cases with normal HSG and suspicious 2-D US, 30.8% were found to be normal by 3D sonography. In cases where hysteroscopy was done, the results were 100% in concordance with the 3-D US evaluations. Conclusions: 3-D US is an accurate test for the assessment of uterine congenital anomalies. Its ability to concomitantly visualized, the external uterine contour with the uterine cavity on the same coronal plan, makes this noninvasive, easy to perform test the procedure of choice for the diagnosis of uterine anomalies.展开更多
基金supported by a grant from the Youth Science Foundation of China (No.30600213)
文摘The present study evaluated the application of three dimensional echocardigraphy (3DE) in the diagnosis of atrial septal defect (ASD) and the measurement of its size by 3DE and compared the size with surgical findings. Two-dimensional and real-time three dimensional echocardiography (RT3DE) was performed in 26 patients with atrial septal defect, and the echocardiographic data were compared with the surgical findings. Significant correlation was found between defect diameter by RT3DE and that measured during surgery (r=0.77, P〈0.001). The defect area changed significantly during cardiac cycle. Percentage change in defect size during cardiac cycle ranged from 6%-70%. Our study showed that the size and morphology of atrial septal defect obtained with RT3DE correlate well with surgical findings. Therefore, RT3DE is a feasible and accurate non-invasive imaging tool for assessment of atrial septal size and dynamic changes.
文摘AIM: To differentiate focal liver lesions based on enhancement patterns using three-dimensional ultrasonography (3D US) with perflubutane-based contrast agent.METHODS: Two hundred and eighty two patients with focal liver lesions,including 168 hepatocellular carcinomas (HCCs),63 metastases,40 hemangiomas and 11 focal nodular hyperplasias (FNHs),were examined by 3D US with perflubutane-based contrast agent.Tomographic ultrasound images and sonographic angiograms were reconstructed.Among 282 lesions,enhancement patterns of 163 lesions between January 2007 and October 2007 were analyzed retrospectively.Then from November 2007 to May 2008,compared with contrast-enhanced (CE) 2D US,CE 3D US was performed on 119 lesions for prospective differential diagnosis.Sensitivity,specificity,area under receiver operating characteristic curve (Az) and inter-reader agreement were assessed.RESULTS: With the tridimensional view,dominant enhancement patterns were revealed as diffuse enhancement or peripheral ring-like enhancement,followed with washout change for HCCs or metastases,respectively,and peripheral nodular enhancement or diffuse enhancement with spoke-wheel arteries,followed by persistent enhancement for hemangiomas or FNHs,respectively.At CE 3D US,the prospective differentiation of lesions showed sensitivity 92% (mean for two readers),specificity 91% and Az value 0.95 for HCCs,84%,97%,and 0.95 for metastases,91%,98%,and 0.98 for hemangiomas and 80%,99%,and 0.99 for FNHs,respectively,while good to excellent inter-reader agreement was achieved.No significant difference exists between prospective diagnosis accuracy at CE 3D US and that at CE 2D US.CONCLUSION: CE 3D US provides a spatial perspective for liver tumor enhancement,and could help in differentiating focal liver lesions.
基金supported by the Guanghua Innovation Medical Research Fund(No.0203116)
文摘Objective To quantitatively analyze the fetal lung echo and right lung volume in the third trimester by real-time three-dimensional ultrasound(3-D US)and evaluate the feasibility of fetal lung maturity.Methods A total of 732 women with normal singleton pregnancies between 28 and 42 weeks of gestation underwent ultrasound examination.The 3-D US equipment with a 3.5-5 MHz transabdominal transducer was used for the fetal biometric measurement.The echogenicity ratio between fetal lung and liver was compared.The fetal lung volume was calculated by the rotational multiplanar technique for volume measurement(VOCAL).Results The right fetal lung volume increased with the increase of gestational age with a linear positive correlation(r=0.884,P<0.01).After 34 weeks,the echogenicity ratio of fetal lung to liver was more than 1.1.Conclusion The echogenicity of lung/liver and fetal lung volume could be used as normal fetal predictable indicators for fetal lung maturity.
基金This project was a science research- planning schemesponsored by Educational Committee of Hubei Province (No.99C0 6 9) and a fifth Three- year Research- planning Schemeof Medicine sponsored by Hubei Provincial Health Bureau(Serial No.WJ0 15 19)
文摘To evaluate the clinical value of three dimensional ultrasonography (3DUS) in prenatal diagnosis, 134 pregnant women with high risk factors in second and third trimester were examined by 3DUS. The results showed that 3DUS could provide more diagnostic information, exclude the abnormalities and enhance the confidence level of physician in 102 normal pregnant women. 3DUS was helpful in the diagnosis in 17 (60.7 %) of 28 cases of fetal anomalies. However, 3DUS was not useful in evaluating intrauterine growth retardation in 4 cases. It is conclucded that 3DUS is helpful in prenatal diagnosis.
基金This project was a science research- planning scheme sponsored by Educational Com mittee of Hubei Province (No:99C0 6 9)
文摘To investigate the clinical value of three dimensional ultrasonography (3DUS) in obstetrics, various 3DUS rendering methods including surface mode, transparent mode and multiplanar mode were employed to scan 30 fetuses in second and third trimester by using the transabdominal volume transducer. The results showed that surface mode could vividly demonstrate the surface morphologic features of the fetuses, as well as the stereo shape and the spatial relationship among the surface structures. The face, limbs, umbilical cord and outer genitalia of the fetus could be well displayed by surface mode. Transparent mode could reveal the bony structures under the surface, such as ribs, vertebrae, crania, etc. The result was not affected by the sophisticated curvature of these bony structures and the success rate was up to 100 %. When rendered by multiplanar mode, the region of interest (ROI) could be viewed from different directions. It should be concluded that 3DUS could serve as a supplement to two dimensional ultrasonography (2DUS). 3DUS might play an important role in prenatal diagnosis and enhance the diagnostic confidence level of the physicians.
文摘<strong>Objective: </strong>To explore the value of real-time bedside ultrasonography in the etiologic diagnosis of acute dyspnea.<strong> Methods:</strong> Sixty-two patients with acute dyspnea who were treated in our hospital from January 2016 to December 2020 were randomly selected and their clinical data were retrospectively analyzed. All patients were randomly divided into a control group for routine examinations (n = 31) and an observation group for real-time beside ultrasonography (n = 31). The costs of medical examinations, examination duration, and diagnostic results of severe pneumonia, acute cardiogenic pulmonary edema, pulmonary embolism, chronic obstructive pulmonary disease, and pneumothorax (including sensitivity, specificity, positive predictive value, negative predictive value, and diagnostic accuracy) of the two groups of patients were compared and analyzed. <strong>Results:</strong> Compared with the control group, the observation group had significantly shorter examinations (P < 0.05). Although the cost of medical examinations of the observation group tended to be higher, the difference between groups was not significant (P > 0.05). Moreover, there were no significant differences in left ventricular ejection fraction, left ventricular end-diastolic diameter, or brain natriuretic peptide between the two groups (P > 0.05). Comparison of the etiologic diagnosis results between the two groups showed that the observation group had significantly higher diagnostic sensitivity, specificity, positive and negative predictive values, and diagnostic accuracy for various causes compared with the control group (P < 0.05). <strong>Conclusion:</strong> Real-time bedside ultrasonography for the etiologic diagnosis of patients with acute dyspnea was quicker and had higher diagnostic accuracy;thus providing accurate guidance for the disease treatment, and having a higher promotional value in clinical practice compared with routine examinations.
文摘To investigate the methodology and evaluate the clinical value of surface mode on three- dimensional ultrasonography (3DUS) in static anatomical structures, 62 patients with various diseases were studied. The equipment used here was Voluson 530D 3DUS imaging system and 3D volume trahsducer with frequency being 3. 0-5. 0 MHz. The 3DUS rendering method was surface mode. The results showed that: 1 ) Surface mode of 3DUS could demonstrate clearly the anatomical characteristics of the region-of-interest (ROI) and the inner wall of lesions or organs that contained fluid. The anatomic details, such as location, size, shape, and number of the ROI, could be visualized intuitively; 2) The outer anatomic features (e. g. contour, edge, configuration, etc. ) of some organs or lesions surrounded by fluid could be displayed clearly. It could be concluded that surface mode on 3DUS could provide more diagnostic information than two-dimensional ultrasonography (2DUS) in some cases and could served as a beneficial supplement to ZDUS in clinical practice.
文摘Objectives: To demonstrate the value of 3-dimensional (3-D) ultrasound (US) in the diagnosis of congenital uterine anomalies. Methods: Fifty one infertile patients referred to our US unit during 12 years period, with suspected diagnosis of congenital uterine anomalies by previous HSG or 2D US examinations, were evaluated by transvaginal 3-D US. The 3-D US diagnoses were compared to the initial HSG diagnosis, and to hysteroscopic evaluation when performed. Results: 3-D scan confirmed the initial HSG diagnosis in 27 out of 51 (52.9%) women. The concordancy rates between the initial diagnosis by HSG and 3-D US results were 30.4% for bicornuate uterus;75% for arcuate uterus;83% for septate uterus;and 80% for unicornuate uterus. Of the 13 cases with normal HSG and suspicious 2-D US, 30.8% were found to be normal by 3D sonography. In cases where hysteroscopy was done, the results were 100% in concordance with the 3-D US evaluations. Conclusions: 3-D US is an accurate test for the assessment of uterine congenital anomalies. Its ability to concomitantly visualized, the external uterine contour with the uterine cavity on the same coronal plan, makes this noninvasive, easy to perform test the procedure of choice for the diagnosis of uterine anomalies.