期刊文献+
共找到16篇文章
< 1 >
每页显示 20 50 100
Novel approach of ultrasound-guided lateral recess block for a patient with lateral recess stenosis: A case report 被引量:1
1
作者 Jiao Yang Xin-Ling Li Qing-Bing Li 《World Journal of Clinical Cases》 SCIE 2024年第5期1010-1017,共8页
BACKGROUND Ultrasound guide technology,which can provide real-time visualization of the needle tip and tissues and avoid many adverse events,is widely used in mini-mally invasive therapy.However,the studies on ultraso... BACKGROUND Ultrasound guide technology,which can provide real-time visualization of the needle tip and tissues and avoid many adverse events,is widely used in mini-mally invasive therapy.However,the studies on ultrasound-guided Lateral recess block(LRB)are limited,this is probably because there is no recognized standard method for ultrasound scanning.This study aimed to evaluate the effect of ultrasound-guided LRB in patients with lateral recess stenosis(LRS).CASE SUMMARY A 65-year-old patient complained of low back pain accompanied occasionally by pain and numbness in the left lower limb.Physical examination showed ten-derness on the spinous process and paraspinal muscles from L1 to S1,extensor hallucis longus and tibialis anterior weakness(muscle strength:4-),and a positive straight leg raising test in the left lower limb(60°).Magnetic resonance imaging showed L4–L5 disc degeneration with left LRS and nerve root entrapment.Subsequently,the patient was diagnosed with LRS.This patient was treated with a novel ultrasound-guided LRB approach.The patient’s symptoms significantly improved without any complications at 1 wk postoperatively and at the 3-month follow-up.CONCLUSION This is the first report on the LRS treatment with ultrasound-guided LRB from the contralateral spinous process along the inner side of the articular process by out-plane technique.Further studies are expected to investigate the efficacy and safety of ultrasound-guided LRB for patients with LRS. 展开更多
关键词 Lateral recess stenosis ultrasound Lateral recess block real-time visualization Low back pain Case report
下载PDF
Value of myocardial function in children with Kawasaki disease by two-dimensional and three-dimensional ultrasound speckle tracking
2
作者 Ya-Mei Shen Tao-Min Bai +4 位作者 Xue-Mei Zhang Chun-Miao Kang Xiao-Ni Chang Yan-Hua Gao Xiao-Hua Yan 《Journal of Hainan Medical University》 2019年第21期58-61,共4页
Objective:To investigate the value of two-dimensional ultrasound speckle tracking(2D-STI)and three-dimensional ultrasound speckle tracking(3D-STI)in evaluating myocardial function in children with Kawasaki disease.Met... Objective:To investigate the value of two-dimensional ultrasound speckle tracking(2D-STI)and three-dimensional ultrasound speckle tracking(3D-STI)in evaluating myocardial function in children with Kawasaki disease.Methods 92 children with Kawasaki disease admitted to our hospital from February 2017 to February 2019 were retrospectively analyzed.50 children who underwent 3D-STI examination were taken as observation group and 42 children who underwent 2D-STI examination were taken as control group.The left ventricular systolic function index,storage time and analysis time of the image,the diameter of coronary artery,the strain difference of left ventricular basal segment,middle segment,apical segment and whole segment were observed.Results The levels of left ventricular end-diastolic volume(LVEDV),left ventricular end-systolic volume(LVESV),left ventricular myocardial mass(LVMI)in the observation group were higher than those in the control group(P<0.05),but there was no statistical difference in left ventricular ejection fraction(LVEF)between the two groups(P>0.05).The storage time and analysis time of the image in the observation group were significantly lower than those in the control group(P<0.05).The left coronary artery(LCA)and right coronary artery(RCA)in the observation group were higher than those in the control group(P<0.05).There was no statistical difference between left anterior descending(LAD)in the two groups(P>0.05).The longitudinal peak systolic strain(LS),circumferential peak systolic strain(CS)and radial peak systolic strain(RS)in the observation group were higher than those in the control group(P<0.05).The global longitudinal peak strain(GLS),global circumferential peak strain(GCS)and global radial peak strain(GRS)in the observation group were higher than those in the control group(P<0.05).LS and CS in the middle segment of the observation group were higher than those in the control group(P<0.05).Conclusions Compared with 2D-STI,3D-STI can objectively and accurately reflect the myocardial function of children with Kawasaki disease. 展开更多
关键词 KAWASAKI disease two-dimensional ultrasound SPECKLE TRACKING three-dimensional ultrasound SPECKLE TRACKING myocardial FUNCTION left ventricular systolic FUNCTION
下载PDF
Correlation analysis of real-time three-dimensional ultrasound in diagnosis of left ventricular function, portal hemodynamics and severity of liver function in patients with liver cirrhosis
3
作者 Lin Li Hong-Ying Zhu He-Juan Du 《Journal of Hainan Medical University》 2019年第12期67-70,共4页
Objective:To analyze the correlation between real-time three-dimensional ultrasound in diagnosis of left ventricular function, portal hemodynamics and severity of liver function in patients with liver cirrhosis.Method... Objective:To analyze the correlation between real-time three-dimensional ultrasound in diagnosis of left ventricular function, portal hemodynamics and severity of liver function in patients with liver cirrhosis.Methods: 90 patients with cirrhosis admitted to our hospital from January 2017 to December 2018 were enrolled in the cirrhosis group, and the cirrhosis components were group A, B and C according to the Child-Pauh classification criteria. During the same period, 90 healthy subjects who underwent physical examination were selected as the control group;real-time three-dimensional ultrasonography was performed to examine left ventricular function and portal hemodynamic parameters;Pearson correlation was used to analyze left ventricular function, portal hemodynamics and liver. Functional severity relationship.Results: The left heart E and E/A levels in the cirrhosis group were significantly lower than those in the control group (P<0.05), and the A level was significantly higher than the control group (P<0.05). The Dpv and Q levels in the cirrhosis group were significantly higher than those in the healthy control group. The difference was statistically significant (P<0.05), and the level of Vpv was significantly lower than that of healthy controls (P<0.05). There were significant differences in E, A and E/A levels between different Child-Paugh patients (P<0.05). There were significant differences in portal hemodynamics Dpv, Vpv and Q between the different Child-Paugh grades, and the difference was statistically significant (P<0.05);left heart function E and E/A and liver function severity There was a significant negative correlation (P<0.05). There was a significant positive correlation between left cardiac function A and liver function severity (P<0.05). Portal vein hemodynamics Dpv, Vpv and QE were significantly associated with liver function severity. Positive correlation (P<0.05). Conclusion: Real-time three-dimensional ultrasound can effectively detect left ventricular function and portal hemodynamics changes in patients with cirrhosis, and left heart function, portal hemodynamics and liver function severity are significantly correlated. 展开更多
关键词 real-time three-dimensional ultrasound CIRRHOSIS Left VENTRICULAR FUNCTION Portal HEMODYNAMICS Liver FUNCTION
下载PDF
Differential diagnosis of different types of solid focal liver lesions using two-dimensional shear wave elastography 被引量:3
4
作者 Jia Guo Dong Jiang +4 位作者 Yi Qian Jiao Yu Yi-Jun Gu Yu-Qing Zhou Hui-Ping Zhang 《World Journal of Gastroenterology》 SCIE CAS 2022年第32期4715-4724,共10页
BACKGROUND The clinical management and prognosis differ between benign and malignant solid focal liver lesions(FLLs),as well as among different pathological types of malignant FLLs.Accurate diagnosis of the possible t... BACKGROUND The clinical management and prognosis differ between benign and malignant solid focal liver lesions(FLLs),as well as among different pathological types of malignant FLLs.Accurate diagnosis of the possible types of solid FLLs is important.Our previous study confirmed the value of shear wave elastography(SWE)using maximal elasticity(Emax)as the parameter in the differential diagnosis between benign and malignant FLLs.However,the value of SWE in the differential diagnosis among different pathological types of malignant FLLs has not been proved.AIM To explore the value of two-dimensional SWE(2D-SWE)using Emax in the differential diagnosis of FLLs,especially among different pathological types of malignant FLLs.METHODS All the patients enrolled in this study were diagnosed as benign,malignant or undetermined FLLs by conventional ultrasound.Emax of FLLs and the periphery of FLLs was measured using 2D-SWE and compared between benign and malignant FLLs or among different pathological types of malignant FLLs.RESULTS The study included 32 benign FLLs in 31 patients and 100 malignant FLLs in 96 patients,including 16 cholangiocellular carcinomas(CCCs),72 hepatocellular carcinomas(HCCs)and 12 liver metastases.Thirty-five FLLs were diagnosed as undetermined by conventional ultrasound.There were significant differences between Emax of malignant(2.21±0.57 m/s)and benign(1.59±0.37 m/s)FLLs(P=0.000),and between Emax of the periphery of malignant(1.52±0.39 m/s)and benign(1.36±0.44 m/s)FLLs(P=0.040).Emax of liver metastases(2.73±0.99 m/s)was significantly higher than that of CCCs(2.14±0.34 m/s)and HCCs(2.14±0.46 m/s)(P=0.002).The sensitivity,specificity and accuracy were 71.00%,84.38%and 74.24%respectively,using Emax>1.905 m/s(AUC 0.843)to diagnose as malignant and 23 of 35(65.74%)FLLs with undetermined diagnosis by conventional ultrasound were diagnosed correctly.CONCLUSION Malignant FLLs were stiffer than benign ones and liver metastases were stiffer than primary liver carcinomas.2D-SWE with Emax was a useful complement to conventional ultrasound for the differential diagnosis of FLLs. 展开更多
关键词 Focal liver lesions Conventional ultrasound two-dimensional shear wave elastography Differential diagnosis
下载PDF
Diagnostic problems in two-dimensional shear wave elastography of the liver 被引量:4
5
作者 Hiroko Naganuma Hideaki Ishida +3 位作者 Atsushi Uno Hiroshi Nagai Hidekatsu Kuroda Masahiro Ogawa 《World Journal of Radiology》 CAS 2020年第5期76-86,共11页
Two-dimensional shear wave elastography(2D-SWE)is used in the clinical setting for observation of the liver.Unfortunately,a wide spectrum of artifactual images are frequently encountered in 2D-SWE,the precise mechanis... Two-dimensional shear wave elastography(2D-SWE)is used in the clinical setting for observation of the liver.Unfortunately,a wide spectrum of artifactual images are frequently encountered in 2D-SWE,the precise mechanisms of which remain incompletely understood.This review was designed to present many of the artifactual images seen in 2D-SWE of the liver and to analyze them by computer simulation models that support clinical observations.Our computer simulations yielded the following suggestions:(1)When performing 2D-SWE in patients with chronic hepatic disease,especially liver cirrhosis,it is recommended to measure shear wave values through the least irregular hepatic surface;(2)The most useful 2D-SWE in patients with focal lesion will detect lesions that are poorly visible on B-mode ultrasound and will differentiate true tumors from pseudo-tumors(e.g.,irregular fatty change);and(3)Measurement of shear wave values in the area posterior to a focal lesion must be avoided. 展开更多
关键词 two-dimensional shear wave elastography ultrasound ARTIFACTS Liver cirrhosis Liver tumor Computer simulation model
下载PDF
Real-time virtual sonography visualization and its clinical application in biliopancreatic disease 被引量:1
6
作者 Atsushi Sofuni Takao Itoi +11 位作者 Fumihide Itokawa Takayoshi Tsuchiya Toshio Kurihara Kentaro Ishii Syujiro Tsuji Nobuhito Ikeuchi Reina Tanaka Junko Umeda Ryosuke Tonozuka Mitsuyoshi Honjo Shuntaro Mukai Fuminori Moriyasu 《World Journal of Gastroenterology》 SCIE CAS 2013年第42期7419-7425,共7页
AIM:To evaluate the usefulness of real-time virtual sonography(RVS)in biliary and pancreatic diseases.METHODS:This study included 15 patients with biliary and pancreatic diseases.RVS can be used to observe an ultrasou... AIM:To evaluate the usefulness of real-time virtual sonography(RVS)in biliary and pancreatic diseases.METHODS:This study included 15 patients with biliary and pancreatic diseases.RVS can be used to observe an ultrasound image in real time by merging the ultrasound image with a multiplanar reconstruction computed tomography(CT)image,using pre-scanned CT volume data.The ultrasound used was EUB-8500with a convex probe EUP-C514.The RVS images were evaluated based on 3 levels,namely,excellent,good and poor,by the displacement in position.RESULTS:By combining the objectivity of CT with free scanning using RVS,it was possible to easily interpret the relationship between lesions and the surrounding organs as well as the position of vascular structures.The resulting evaluation levels of the RVS images were12 excellent(pancreatic cancer,bile duct cancer,cholecystolithiasis and cholangiocellular carcinoma)and 3 good(pancreatic cancer and gallbladder cancer).Compared with conventional B-mode ultrasonography and CT,RVS images achieved a rate of 80%superior visualization and 20%better visualization.CONCLUSION:RVS has potential usefulness in objective visualization and diagnosis in the field of biliary and pancreatic diseases. 展开更多
关键词 BILIARY and pancreatic disease COMPUTED tomography-multiplanar reconstruction IMAGE Navigation real-time ultrasound IMAGE real-time VIRTUAL SONOGRAPHY
下载PDF
Current use of intraoperative ultrasound in modern liver surgery
7
作者 Kai-Jian Chu Yoshikuni Kawaguchi Kiyoshi Hasegawa 《Oncology and Translational Medicine》 2023年第4期168-175,共8页
Ultrasound plays an important role not only in preoperative diagnosis but also in intraoperative guidance for liver surgery.Intraoperative ultrasound(IOUS)has become an indispensable tool for modern liver surgeons,esp... Ultrasound plays an important role not only in preoperative diagnosis but also in intraoperative guidance for liver surgery.Intraoperative ultrasound(IOUS)has become an indispensable tool for modern liver surgeons,especially for minimally invasive surgeries,partially substituting for the surgeon’s hands.In fundamental mode,Doppler mode,contrast enhancement,elastography,and real-time virtual sonography,IOUS can provide additional real-time information regarding the intrahepatic anatomy,tumor site and characteristics,macrovascular invasion,resection margin,transection plane,perfusion and outflow of the remnant liver,and local ablation efficacy for both open and minimally invasive liver resections.Identification and localization of intrahepatic lesions and surrounding structures are crucial for performing liver resection,preserving the adjacent vital vascular and bile ducts,and sparing the functional liver parenchyma.Intraoperative ultrasound can provide critical information for intraoperative decision-making and navigation.Therefore,all liver surgeons must master IOUS techniques,and IOUS should be included in the training of modern liver surgeons.Further investigation of the potential benefits and advances in these techniques will increase the use of IOUS in modern liver surgeries worldwide.This study comprehensively reviews the current use of IOUS in modern liver surgeries. 展开更多
关键词 Intraoperative ultrasound(IOUS) Contrast-enhanced intraoperative ultrasound(CE-IOUS) Intraoperative ultrasound cholangiography(IOUSC) Doppler intraoperative ultrasound(Doppler IOUS) real-time tissue elastography(RTE) real-time virtual sonography(RVS)
下载PDF
Modified B-ultrasound method for measurement of antral section only to assess gastric function and guide enteral nutrition in critically ill patients 被引量:27
8
作者 Ying Liu Ya-Kun Gao +1 位作者 Lei Yao Li Li 《World Journal of Gastroenterology》 SCIE CAS 2017年第28期5229-5236,共8页
AIM To establish a modified B-ultrasound method of measuring the antral section only to assess gastric motility in healthy people,and evaluate its application in guiding enteral nutrition(EN) in critically ill patient... AIM To establish a modified B-ultrasound method of measuring the antral section only to assess gastric motility in healthy people,and evaluate its application in guiding enteral nutrition(EN) in critically ill patients. METHODS First,30 healthy volunteers were selected. The modified B-ultrasound method and the traditional B-ultrasound method were applied to assess gastric function. The correlation of indices of gastric function between the two groups was analyzed statistically. In addition,64 critically ill patients were selected,and the modified B-ultrasound method and the gastric juice withdrawal method were applied to guide the implementation of EN. Daily caloric value,the time required to achieve complete EN,ICU stay,hospitalization time,and serum prealbumin and albumin levels were recorded and compared between the two groups. Kaplan-Meier survival curve was used to compare the complications of EN between the two groups. RESULTS In healthy subjects,there was a good correlation among gastric emptying time,antral contraction frequency andantral motility index between the two groups(r = 0.57,0.61 and 0.54,respectively). The study on critically ill patients also revealed that a better effect of EN was achieved in the modified B-ultrasound method group,in which patients had shorter ICU stay and hospitalization time and higher levels of serum prealbumin and albumin. The Kaplan-Meier survival analysis revealed that the improved B-ultrasound method was associated with significantly fewer EN complications(P = 0.031).CONCLUSION The modified B-ultrasound method can provide a good real-time assessment of gastric function and has a better effect than the traditional method in guiding EN in critically ill patients. 展开更多
关键词 Gastric emptying real-time ultrasound Critically ill patients Enteral nutrition
下载PDF
Clinical Value of Transperineal 3D Volume Ultrasound Combined with 2D High Frequency Ultrasound in Anal Fistula 被引量:3
9
作者 Dan Yang Xiufen Yao 《Journal of Biosciences and Medicines》 2020年第5期12-19,共8页
Objective: To explore the clinical diagnostic value of transperineal volume ultrasound combined with two-dimensional high-frequency ultrasound for anal fistula. Methods: A total of 52 patients with anal fistula admitt... Objective: To explore the clinical diagnostic value of transperineal volume ultrasound combined with two-dimensional high-frequency ultrasound for anal fistula. Methods: A total of 52 patients with anal fistula admitted to the Affiliated Hospital of Shaanxi University of Traditional Chinese Medicine from December 2017 to July 2018 were selected. They were all undergoing transperineal 3D volume ultrasound combined with 2D high-frequency ultrasound examination, and the diagnosis results were analyzed. The results of ultrasonography and surgical pathology were compared. Results: Among 52 patients, 3D volume ultrasound combined with 2D high-frequency ultrasound were used to diagnose 32 cases of anal fistula intersphincteric type, 14 cases of transsphincter type, 5 cases of supra-sphincter type, and 1 case of extra-sphincter type. T supervisor classification accuracy rate is 90%. The detection rate of branch pipes was 92%, and the compliance rate of internal fistula was 95%. Two-dimensional high-frequency ultrasound was used to diagnose 34 cases of anal fistula intersphincteric type, 14 cases of transsphincter type, 4 cases of supra-sphincter type, and 0 cases of extra-sphincter type. The detection rate of branch canals was 42%, and the accuracy of type classification was 90%. The coincidence rate was 95%. There was a statistically significant difference in the detection rate of the anal fistula branch and the coincidence rate of the internal fistula between the two methods (both P Conclusion: 1) The overall coincidence rate of three-dimensional volumetric ultrasound combined with two-dimensional high-frequency ultrasound in the diagnosis of anal fistula is high;2) Three-dimensional volumetric ultrasound technology has great application prospects in infants and anal fistulas. 展开更多
关键词 two-dimensional HIGH-FREQUENCY ultrasound Anal Fistula Three-Dimensional VOLUME ultrasound COMBINED with two-dimensional HIGH-FREQUENCY ultrasound
下载PDF
Real Time Ultrasound Elastography for the Differentiation of Benign and Malignant Thyroid Nodules 被引量:6
10
作者 Hamad Elniel H. Eltyib Ibrahim A. Awad +1 位作者 Naglaa M. Elsayed Saddig D. Jastaniah 《Open Journal of Medical Imaging》 2014年第1期38-47,共10页
The purpose of this study was to evaluate the predictive value of real-time ultrasound elastography (RUE) in differentiating benign from malignant thyroid nodules, with fine needle aspiration cytology analysis as the ... The purpose of this study was to evaluate the predictive value of real-time ultrasound elastography (RUE) in differentiating benign from malignant thyroid nodules, with fine needle aspiration cytology analysis as the reference standard. A total of 78 consecutive patients with thyroid nodules who were selected for fine needle aspiration biopsies were examined in this prospective study. 78 nodules in these patients were examined by conventional ultrasound, and ultrasound elastography. The final diagnosis was obtained from cytological findings. Tissue stiffness on ultrasound elastography was scored from 1 (low stiffness over the entire nodule) to 5 (high stiffness over the entire nodule and surrounding tissue). On real-time ultrasound elastography, 47 of 62 benign nodules (76%) had a score of 1 or 2, whereas 15 of 16 malignant nodules had a score of 3 to 5, with sensitivity of 93.7%, specificity of 90%, a positive predictive value of 71%, and a negative predictive value of 98%. Real-time ultrasound elastography is a promising imaging technique that is useful in the differential diagnosis of thyroid cancer. Utilization of ultrasound elastography could reduce the rate of thyroid biopsies because of its high elasticity being highly associated with benign cytology. 展开更多
关键词 ELASTOGRAPHY real-time THYROID NODULES ultrasound MALIGNANT
下载PDF
Clinical efficacy of ultrasound-guided pulsed radiofrequency combined with ganglion impar block for treatment of perineal pain 被引量:2
11
作者 Shui-Qing Li Ling Jiang +1 位作者 Li-Gang Cui Dong-Lin Jia 《World Journal of Clinical Cases》 SCIE 2021年第9期2153-2159,共7页
BACKGROUND Ganglion impar block alone or pulsed radiofrequency alone are effective options for treating perineal pain.However,ganglion impar block combined with pulsed radiofrequency(GIB-PRF)for treating perineal pain... BACKGROUND Ganglion impar block alone or pulsed radiofrequency alone are effective options for treating perineal pain.However,ganglion impar block combined with pulsed radiofrequency(GIB-PRF)for treating perineal pain is rare and the puncture is usually performed with X-ray or computed tomography guidance.AIM To evaluate the safety and clinical efficacy of real-time ultrasound-guided GIBPRF in treating perineal pain.METHODS Thirty patients with perineal pain were included and were treated by GIB-PRF guided by real-time ultrasound imaging between January 2015 and December 2016.Complications were recorded to observe the safety of the ultrasound-guided GIB-PRF procedure,and visual analogue scale(VAS)scores at 24 h before and after treatment and 1,3,and 6 mo later were analyzed to evaluate clinical efficacy.RESULTS Ultrasound-guided GIB-PRF was performed successfully in all patients,and no complications occurred.Compared with pretreatment scores,the VAS scores were significantly lower(P<0.05)at the four time points after treatment.The VAS scores at 1 and 3 mo were slightly lower than those at 24 h(P>0.05)and were significantly lower at 6 mo after treatment(P<0.05).There was a tendency toward lower VAS scores at 6 mo after treatment compared with those at 1 and 3 mo(P>0.05).CONCLUSION Ultrasound-guided GIB-PRF was a safe and effective way to treat perineal pain.The 6-mo short-term clinical efficacy was favorable,but the long-term outcomes need future study. 展开更多
关键词 Ganglion impar Perineal pain Pulsed radiofrequency real-time ultrasound guidance
下载PDF
Real-time SERS monitoring anticancer drug release along with SERS/MR imaging for pH-sensitive chemo-phototherapy
12
作者 Xueqin Huang Bingbing Sheng +10 位作者 Hemi Tian Qiuxia Chen Yingqi Yang Brian Bui Jiang Pi Huaihong Cai Shanze Chen Jianglin Zhang Wei Chen Haibo Zhou Pinghua Sun 《Acta Pharmaceutica Sinica B》 SCIE CAS CSCD 2023年第3期1303-1317,共15页
In situ and real-time monitoring of responsive drug release is critical for the assessment of pharmacodynamics in chemotherapy.In this study,a novel pH-responsive nanosystem is proposed for real-time monitoring of dru... In situ and real-time monitoring of responsive drug release is critical for the assessment of pharmacodynamics in chemotherapy.In this study,a novel pH-responsive nanosystem is proposed for real-time monitoring of drug release and chemo-phototherapy by surface-enhanced Raman spectroscopy(SERS).The Fe3O4@Au@Ag nanoparticles(NPs)deposited graphene oxide(GO)nanocomposites with a high SERS activity and stability are synthesized and labeled with a Raman reporter 4-mercaptophenylboronic acid(4-MPBA)to form SERS probes(GO-Fe3O4@Au@Ag-MPBA).Furthermore,doxorubicin(DOX)is attached to SERS probes through a pH-responsive linker boronic ester(GO-Fe3O4@Au@Ag-MPBA-DOX),accompanying the 4-MPBA signal change in SERS.After the entry into tumor,the breakage of boronic ester in the acidic environment gives rise to the release of DOX and the recovery of 4-MPBA SERS signal.Thus,the DOX dynamic release can be monitored by the real-time changes of 4-MPBA SERS spectra.Additionally,the strong T2 magnetic resonance(MR)signal and NIR photothermal transduction efficiency of the nanocomposites make it available for MR imaging and photothermal therapy(PTT).Altogether,this GO-Fe3O4@Au@Ag-MPBA-DOX can simultaneously fulfill the synergistic combination of cancer cell targeting,pH-sensitive drug release,SERS-traceable detection and MR imaging,endowing it great potential for SERS/MR imaging-guided efficient chemo-phototherapy on cancer treatment. 展开更多
关键词 Surface-enhanced Raman spectroscopyp H-sensitive nanoparticles real-time monitoring Chemo-phototherapy Drug delivery systems Anti-cancer nanotechnology two-dimensional matrix Cancer cell targeting MR imaging
原文传递
Validation of real-time three-dimensional echocardiography for quantifying left and right ventricular volumes:an experimental study 被引量:38
13
作者 费洪文 王新房 +5 位作者 谢明星 庄磊 陈立新 杨颖 黄润青 王静 《Chinese Medical Journal》 SCIE CAS CSCD 2004年第5期695-699,共5页
Background Assessment of the left ventricular (LV) and the right ventricular (RV) volumes and their functions is important for prognostic prediction and clinical decision making. We compared the accuracy for quantify... Background Assessment of the left ventricular (LV) and the right ventricular (RV) volumes and their functions is important for prognostic prediction and clinical decision making. We compared the accuracy for quantifying the LV and the RV volumes in vitro between conventional two-dimensional echocardiography (2DE) and real-time three-dimensional echocardiography (RT3DE) Methods The volumes of 37 rubber-models (10 regularly shaped to simulate normal LV, 7 shaped to simulate LV with symmetric aneurysm, 8 shaped to simulate LV with asymmetric aneurysm, and 12 irregularly shaped to simulate normal RV) and 10 excised canine hearts were measured by RT3DE and 2DE On RT3DE 'full volume' imaging, the inner-surfaces of the rubber-models and canine LV and RV were outlined and the volumes were measured using 2-, 4-, 8- and 16-plane methods with the RT3DE analysis software On 2DE imaging, the volumes were measured by the Simpson method The LV and RV volumes measured by drained water were served as reference values, with which we compared RT3DE and 2DE data Results In rubber models mimicking normal LV and LV with symmetric aneurysms, RT3DE results were strongly correlated with reference values ( r =0 795-0 998) and there was a good correlation between 2DE estimates and reference values ( r =0 715-0 729) There were no significant differences between RT3DE estimates, 2DE results and reference values ( P >0 05) In rubber models mimicking the RV and LV with asymmetric aneurysm, RT3DE strongly correlated with reference values ( r =0 765-0 988), but 2DE weakly correlated with reference values ( r =0 518-0 592) There were no differences between RT3DE and reference values ( P >0 05), but a significant difference between 2DE and reference values occurred ( P <0 05) For excised canine hearts, there was a strong correlation between RT3DE and reference values ( r =0 728-0 914), while 2DE showed a less obvious correlation ( r =0 502-0 615) Again, there were no significant differences between RT3DE and reference values ( P >0 05), but there was a significant difference between 2DE and reference values ( P <0 05) Conclusions RT3DE can accurately quantify LV and RV volumes and provides a new tool to evaluate LV and RV function For LV and RV measurements by RT3DE, 8-plane strategy is the optimum choice for accuracy and convenience 展开更多
关键词 real-time three-dimensional echocardiography · two-dimensional echocardiography · left ventricular volume · right ventricular volume
原文传递
Non-invasive assessment of liver fibrosis using twodimensional shear wave elastography in patients with autoimmune liver diseases 被引量:8
14
作者 Jie Zeng Ze-Ping Huang +2 位作者 Jian Zheng Tao Wu Rong-Qin Zheng 《World Journal of Gastroenterology》 SCIE CAS 2017年第26期4839-4846,共8页
AIM To determine the diagnostic accuracy of two-dimensional shear wave elastography(2D-SWE) for the noninvasive assessment of liver fibrosis in patients with autoimmune liver diseases(AILD) using liver biopsy as the r... AIM To determine the diagnostic accuracy of two-dimensional shear wave elastography(2D-SWE) for the noninvasive assessment of liver fibrosis in patients with autoimmune liver diseases(AILD) using liver biopsy as the reference standard.METHODS Patients with AILD who underwent liver biopsy and 2D-SWE were consecutively enrolled. Receiver operating characteristic(ROC) curves were constructed to assess the overall accuracy and to identify optimal cut-off values.RESULTS The characteristics of the diagnostic performance were determined for 114 patients with AILD. The areas under the ROC curves for significant fibrosis, severe fibrosis, and cirrhosis were 0.85, 0.85, and 0.86, respectively, and the optimal cut-off values associated with significant fibrosis(≥ F2), severe fibrosis(≥ F3), and cirrhosis(F4) were 9.7 k Pa, 13.2 k Pa and 16.3 k Pa, respectively. 2D-SWE showed sensitivity values of 81.7% for significant fibrosis, 83.0% for severe fibrosis,and 87.0% for cirrhosis, and the respective specificity values were 81.3%, 74.6%, and 80.2%. The overall concordance rate of the liver stiffness measurements obtained using 2D-SWE vs fibrosis stages was 53.5%.CONCLUSION2D-SWE showed promising diagnostic performance for assessing liver fibrosis stages and exhibited high cut-off values in patients with AILD. Low overall concordance rate was observed in the liver stiffness measurements obtained using 2D-SWE vs fibrosis stages. 展开更多
关键词 Autoimmune liver disease Liver fibrosis two-dimensional shear wave elastography ultrasound Liver stiffness
下载PDF
Assessment of diaphragmatic function by ultrasonography:Current approach and perspectives 被引量:4
15
作者 Alain Boussuges Sarah Rives +1 位作者 Julie Finance Fabienne Brégeon 《World Journal of Clinical Cases》 SCIE 2020年第12期2408-2424,共17页
This article reports the various methods used to assess diaphragmatic function by ultrasonography.The excursions of the two hemidiaphragms can be measured using two-dimensional or M-mode ultrasonography,during respira... This article reports the various methods used to assess diaphragmatic function by ultrasonography.The excursions of the two hemidiaphragms can be measured using two-dimensional or M-mode ultrasonography,during respiratory maneuvers such as quiet breathing,voluntary sniffing and deep inspiration.On the zone of apposition to the rib cage for both hemidiaphragms,it is possible to measure the thickness on expiration and during deep breathing to assess the percentage of thickening during inspiration.These two approaches make it possible to assess the quality of the diaphragmatic function and the diagnosis of diaphragmatic paralysis or dysfunction.These methods are particularly useful in circumstances where there is a high risk of phrenic nerve injury or in diseases affecting the contractility or the motion of the diaphragm such as neuro-muscular diseases.Recent methods such as speckle tracking imaging and ultrasound shear wave elastography should provide more detailed information for better assessment of diaphragmatic function. 展开更多
关键词 ultrasound Hemidiaphragm Motion Thickness PARALYSIS Dysfunction two-dimensional mode M-MODE Speckle tracking imaging ultrasound shear wave elastography
下载PDF
2-D/2-D heterostructured biomimetic enzyme by interfacial assembling Mn_(3)(PO_(4))_(2) and MXene as a flexible platform for realtime sensitive sensing cell superoxide 被引量:2
16
作者 Shen Fei Zhao Fang Xin Hu +5 位作者 Zhuan Zhuan Shi Jing Jing Fu Yue Chen Fang Yin Dai Chun Xian Guo Chang Ming Li 《Nano Research》 SCIE EI CAS CSCD 2021年第3期879-886,共8页
It is critical for fabricating flexible biosensors with both high sensitivity and good selectivity to realize real-time monitoring superoxide anion(O_(2)^(·−)),a specific reactive oxygen species that plays critic... It is critical for fabricating flexible biosensors with both high sensitivity and good selectivity to realize real-time monitoring superoxide anion(O_(2)^(·−)),a specific reactive oxygen species that plays critical roles in various biological processes.This work delicately designs a Mn_(3)(PO_(4))_(2)/MXene heterostructured biomimetic enzyme by assembling two-dimensional(2-D)Mn_(3)(PO_(4))_(2) nanosheets with biomimetic activity and 2-D MXene nanosheets with high conductivity and abundant functional groups.The 2-D nature of the two components with strong interfacial interaction synergistically enables the heterostructure an excellent flexibility with retained 100%of the response when to reach a bending angle up to 180°,and 96%of the response after 100 bending/relaxing cycles.It is found that the surface charge state of the heterostructure promotes the adsorption of O_(2)^(·−),while the high-energy active site improves electrochemical oxidation of O_(2)^(·−).The Mn_(3)(PO_(4))_(2)/MXene as a sensing platform towards O2•−achieves a high sensitivity of 64.93µA·µM^(−1)·cm^(−2),a wide detection range of 5.75 nM to 25.93µM,and a low detection limit of 1.63 nM.Finally,the flexible heterostructured sensing platform realizes real-time monitoring of O_(2)^(·−)in live cell assays,offering a promising flexible biosensor towards exploring various biological processes. 展开更多
关键词 two-dimensional(2-D)nanosheets assembled heterostructure interface flexible biosensor real-time monitoring
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部