A magnetic proton recoil (MPR) spectrometer is a novel instrument with superior performance, including high energy resolution, high count rate and good signal-to-noise ratio (SNR) for measurements of neutron spect...A magnetic proton recoil (MPR) spectrometer is a novel instrument with superior performance, including high energy resolution, high count rate and good signal-to-noise ratio (SNR) for measurements of neutron spectra from inertial confinement fusion (ICF) experiments and high power Tokomaks. In this work, the design of a compact MPR spectrometer (cMPR) was evaluated for deuteron-tritium (DT) neutron spectroscopy. The characteristics of the spectrometer were analyzed using 2-D beam transport simulations, 3-D particle transport calculations and Monte-Carlo simulations. Based on the theoretical results, an instrument design that satisfies special experimental requirements is proposed. The energy resolution and efficiency of the spectrometer are also evaluated. The results indicate that the proposed cMPR spectrometer would achieve a detection efficiency and energy resolution of approximately 10?8 and 4%, respectively, for DT neutrons.展开更多
A proton recoil method for measuring D-T neutron energy spectra using polyethylene film and a Si(Au)surface barrier detector is presented. An iteration algorithm for unfolding the recoil proton energy spectrum to th...A proton recoil method for measuring D-T neutron energy spectra using polyethylene film and a Si(Au)surface barrier detector is presented. An iteration algorithm for unfolding the recoil proton energy spectrum to the neutron energy spectrum is investigated. The response matrices R of the polyethylene film at angles of 0o and45o were obtained by simulating the recoil proton energy spectra from mono-energetic neutrons using the MCNPX code. With an assumed D-T neutron spectrum, the recoil proton spectra from the polyethylene film at angles of 0oand 45owere also simulated using the MCNPX code. Based on the response matrices R and the simulated recoil proton spectra at 0oand 45o, the respective unfolded neutron spectra were obtained using the iteration algorithm,and compared with the assumed neutron spectrum. The results show that the iteration algorithm method can be applied to unfold the recoil proton energy spectrum to the neutron energy spectrum for D-T neutron energy spectra measurement using the recoil proton method.展开更多
The magnetic proton recoil(MPR)spectrometer is a novel diagnostic instrument with high perfor-mance for measurements of neutron spectra in inertial confinement fusion(ICF)experiments and high power fusion devices....The magnetic proton recoil(MPR)spectrometer is a novel diagnostic instrument with high perfor-mance for measurements of neutron spectra in inertial confinement fusion(ICF)experiments and high power fusion devices.A compact MPR-type spectrometer dedicated to the research of pulsed deuterium-tritium(DT)neutron spectroscopy of special experimental conditions is currently under design.Analyses of the main parameters and performance of the magnetic analysis system through 3-D particle transport calculations and MonteCarlo simulations and calibration of the system performance as a test using CR-39 solid track detector and α particle from 239pu and 226Ra radioactive sources are presented in this paper.The results indicate that the magnetic analysis system will achieve a detection efficiency level of 10-5-10-4 at an energy resolution of 1.5%-2.1%,and fulfills the design goals of the spectrometer.展开更多
基金Supported by Science and Technology Development Foundation of China Academy of Engineering Physics (2008B0103003)
文摘A magnetic proton recoil (MPR) spectrometer is a novel instrument with superior performance, including high energy resolution, high count rate and good signal-to-noise ratio (SNR) for measurements of neutron spectra from inertial confinement fusion (ICF) experiments and high power Tokomaks. In this work, the design of a compact MPR spectrometer (cMPR) was evaluated for deuteron-tritium (DT) neutron spectroscopy. The characteristics of the spectrometer were analyzed using 2-D beam transport simulations, 3-D particle transport calculations and Monte-Carlo simulations. Based on the theoretical results, an instrument design that satisfies special experimental requirements is proposed. The energy resolution and efficiency of the spectrometer are also evaluated. The results indicate that the proposed cMPR spectrometer would achieve a detection efficiency and energy resolution of approximately 10?8 and 4%, respectively, for DT neutrons.
基金Supported by National Natural Science Foundations of China(11375077,21327801)National Key Scientific Instrument And Equipment Development Project(2013YQ40861)
文摘A proton recoil method for measuring D-T neutron energy spectra using polyethylene film and a Si(Au)surface barrier detector is presented. An iteration algorithm for unfolding the recoil proton energy spectrum to the neutron energy spectrum is investigated. The response matrices R of the polyethylene film at angles of 0o and45o were obtained by simulating the recoil proton energy spectra from mono-energetic neutrons using the MCNPX code. With an assumed D-T neutron spectrum, the recoil proton spectra from the polyethylene film at angles of 0oand 45owere also simulated using the MCNPX code. Based on the response matrices R and the simulated recoil proton spectra at 0oand 45o, the respective unfolded neutron spectra were obtained using the iteration algorithm,and compared with the assumed neutron spectrum. The results show that the iteration algorithm method can be applied to unfold the recoil proton energy spectrum to the neutron energy spectrum for D-T neutron energy spectra measurement using the recoil proton method.
基金Supported by Science and Technology Development Foundation of China Academy of Engineering Physics (2008B0103003)
文摘The magnetic proton recoil(MPR)spectrometer is a novel diagnostic instrument with high perfor-mance for measurements of neutron spectra in inertial confinement fusion(ICF)experiments and high power fusion devices.A compact MPR-type spectrometer dedicated to the research of pulsed deuterium-tritium(DT)neutron spectroscopy of special experimental conditions is currently under design.Analyses of the main parameters and performance of the magnetic analysis system through 3-D particle transport calculations and MonteCarlo simulations and calibration of the system performance as a test using CR-39 solid track detector and α particle from 239pu and 226Ra radioactive sources are presented in this paper.The results indicate that the magnetic analysis system will achieve a detection efficiency level of 10-5-10-4 at an energy resolution of 1.5%-2.1%,and fulfills the design goals of the spectrometer.