BACKGROUND Computed tomography(CT)small bowel three-dimensional(3D)reconstruction is a powerful tool for the diagnosis of small bowel disease and can clearly show the intestinal lumen and wall as well as the outside s...BACKGROUND Computed tomography(CT)small bowel three-dimensional(3D)reconstruction is a powerful tool for the diagnosis of small bowel disease and can clearly show the intestinal lumen and wall as well as the outside structure of the wall.The horizontal axis position can show the best adjacent intestinal tube and the lesion between the intestinal tubes,while the coronal position can show the overall view of the small bowel.The ileal end of the localization of the display of excellent,and easy to quantitative measurement of the affected intestinal segments,the sagittal position for the rectum and the pre-sacral lesions show the best,for the discovery of fistulae is also helpful.Sagittal view can show rectal and presacral lesions and is useful for fistula detection.It is suitable for the assessment of inflammatory bowel disease,such as assessment of disease severity and diagnosis and differential diagnosis of the small bowel and mesenteric space-occupying lesions as well as the judgment of small bowel obstruction points.CASE SUMMARY Bleeding caused by small intestinal polyps is often difficult to diagnose in clinical practice.This study reports a 29-year-old male patient who was admitted to the hospital with black stool and abdominal pain for 3 months.Using the combination of CT-3D reconstruction and capsule endoscopy,the condition was diagnosed correctly,and the polyps were removed using single-balloon enteroscopyendoscopic retrograde cholangiopancreatography without postoperative complications.CONCLUSION The role of CT-3D in gastrointestinal diseases was confirmed.CT-3D can assist in the diagnosis and treatment of gastrointestinal diseases in combination with capsule endoscopy and small intestinal microscopy.展开更多
BACKGROUND Few reports have described living foreign bodies in the human body.The current manuscript demonstrates that computed tomography(CT)is an effective tool for accurate preoperative evaluation of living foreign...BACKGROUND Few reports have described living foreign bodies in the human body.The current manuscript demonstrates that computed tomography(CT)is an effective tool for accurate preoperative evaluation of living foreign bodies in clinic.The threedimensional(3D)reconstruction technology could clearly display anatomical structures,lesions and adjacent organs,improving diagnostic accuracy and guiding the surgical decision-making process.CASE SUMMARY Herein we describe a 68-year-old man diagnosed with digestive tract perforation and acute peritonitis caused by a foreign body of Monopterus albus.The patient pre-sented to the emergency department with complaints of dull abdominal pain,profuse sweating and a pale complexion during work.A Monopterus albus had entered the patient’s body through the anus two hours ago.During hospitalization,the 3D reconstruction technology revealed a perforation of the middle rectum complicated with acute peritonitis and showed a clear and complete Monopterus albus bone morphology in the abdominal and pelvic cavities,with the Monopterus albus biting the mesentery.Laparoscopic examination detected a large(diameter of about 1.5 cm)perforation in the mid-rectum.It could be seen that a Monopterus albus had completely entered the abdominal cavity and had tightly bitten the mesentery of the small intestine.During the operation,the dead Monopterus albus was taken out.CONCLUSION The current manuscript demonstrates that CT is an effective tool for accurate preoperative evaluation of living foreign bodies in clinic.展开更多
With the development of the compressive sensing theory, the image reconstruction from the projections viewed in limited angles is one of the hot problems in the research of computed tomography technology. This paper d...With the development of the compressive sensing theory, the image reconstruction from the projections viewed in limited angles is one of the hot problems in the research of computed tomography technology. This paper develops an iterative algorithm for image reconstruction, which can fit the most cases. This method gives an image reconstruction flow with the difference image vector, which is based on the concept that the difference image vector between the reconstructed and the reference image is sparse enough. Then the l1-norm minimization method is used to reconstruct the difference vector to recover the image for flat subjects in limited angles. The algorithm has been tested with a thin planar phantom and a real object in limited-view projection data. Moreover, all the studies showed the satisfactory results in accuracy at a rather high reconstruction speed.展开更多
The additional sparse prior of images has been the subject of much research in problems of sparse-view computed tomography(CT) reconstruction. A method employing the image gradient sparsity is often used to reduce t...The additional sparse prior of images has been the subject of much research in problems of sparse-view computed tomography(CT) reconstruction. A method employing the image gradient sparsity is often used to reduce the sampling rate and is shown to remove the unwanted artifacts while preserve sharp edges, but may cause blocky or patchy artifacts.To eliminate this drawback, we propose a novel sparsity exploitation-based model for CT image reconstruction. In the presented model, the sparse representation and sparsity exploitation of both gradient and nonlocal gradient are investigated.The new model is shown to offer the potential for better results by introducing a similarity prior information of the image structure. Then, an effective alternating direction minimization algorithm is developed to optimize the objective function with a robust convergence result. Qualitative and quantitative evaluations have been carried out both on the simulation and real data in terms of accuracy and resolution properties. The results indicate that the proposed method can be applied for achieving better image-quality potential with the theoretically expected detailed feature preservation.展开更多
BACKGROUND Primary adenoid cystic carcinoma in the trachea(TACC)is a rare tumour.Tracheal bronchoscopy is always chosen as a routine approach to obtain a pathological diagnosis,but it can be associated with an increas...BACKGROUND Primary adenoid cystic carcinoma in the trachea(TACC)is a rare tumour.Tracheal bronchoscopy is always chosen as a routine approach to obtain a pathological diagnosis,but it can be associated with an increased risk of asphyxia.CASE SUMMARY We describe a case of TACC in a patient evaluated by chest computed tomography(CT)with three-dimensional reconstruction imaging and diagnosed by transoesophageal endoscopic ultrasonography.The pathological diagnosis confirmed tracheal adenoid cystic carcinoma.CONCLUSION We highlight the importance of CT and provide a successful exploration of transoesophageal biopsy as a safe alternative approach.展开更多
The traditional computed tomography(CT)reconstruction methods are noisy,low resolution,poor contrast,and generally not suitable to detect the smaller flaws.Besides,the filter design is also difficult.The CT characteri...The traditional computed tomography(CT)reconstruction methods are noisy,low resolution,poor contrast,and generally not suitable to detect the smaller flaws.Besides,the filter design is also difficult.The CT characteristics reconstruction technology was brought forward to improve in these aspects,which is defined to directly reconstruct the characteristics of the projection for the best requirements not the overall image quality.The two-dimension(2D)and three-dimension(3D)CT characteristics reconstruction algorithm were firstly introduced,then by detailed analysis,experimental results and comparsion of parameters calculated,its advantages in keeping better high-frequency feature,better noise immunity,short time-consuming and easier design are verified.展开更多
Objective To evaluate the clinical features,diagnosis,treatment,and outcome of intralobar pulmonary sequestration (ILS). Methods Patients who were diagnosed with ILS in our hospital between January 1988 and January 20...Objective To evaluate the clinical features,diagnosis,treatment,and outcome of intralobar pulmonary sequestration (ILS). Methods Patients who were diagnosed with ILS in our hospital between January 1988 and January 2009 were retrospectively reviewed. We recorded the clinical symptoms,imaging findings,operative technique,complications,and outcome of these patients. Results Forty-seven patients (25 men and 22 women) with an average age of 32.3 years were enrolled. Forty-two patients had symptoms including cough and hemoptysis. Chest X-ray,computed tomography (CT),magnetic resonance imaging (MRI),and angiography were performed. Thoracotomy was performed in 45 patients,while thoracoscopy was performed in 2 patients. Lobectomy was the most common treatment procedure. Massive bleeding developed in 2 patients due to injury of aberrant supplying artery intraoperatively,1 patient had atrial fibrillation,1 patient had thrombosis of upper extremity postoperatively. All patients were confirmed the diagnosis pathologically,4 accompanied with bronchogenic cyst,15 with bronchiectasis,8 with infection,2 with aspergilloma,and 1 with carcinoid. No late complications occurred. Conclusions ILS is rare,surgery is recommended because some patients may have potential severe complications. Contrast enhanced CT and three-dimensional reconstruction is the best diagnostic method. Both thoracotomy and thoracoscopy are appropriate for the selected candidates.展开更多
Although emission spectral tomography (EST) combines emission spectral measurement with optical computed tomography (OCT), it is difficult to gain transient emission data from a large number of views, therefore, h...Although emission spectral tomography (EST) combines emission spectral measurement with optical computed tomography (OCT), it is difficult to gain transient emission data from a large number of views, therefore, high precision OCT algorithms with few views ought to be studied for EST application. To improve the reconstruction precision in the case of few views, a new computed tomography reconstruction algorithm based on multipurpose optimal criterion and simulated annealing theory (multi-criterion simulated annealing reconstruction technique, MCSART) is proposed. This algorithm can suffice criterion of least squares, criterion of most uniformity, and criterion of most smoothness synchronously. We can get global optimal solution by MCSART algorithm with simulated annealing theory. The simulating experiment result shows that this algorithm is superior to the traditional algorithms under various noises.展开更多
In conventional computed tomography (CT) reconstruction based on fixed voltage, the projective data often ap- pear overexposed or underexposed, as a result, the reconstructive results are poor. To solve this problem...In conventional computed tomography (CT) reconstruction based on fixed voltage, the projective data often ap- pear overexposed or underexposed, as a result, the reconstructive results are poor. To solve this problem, variable voltage CT reconstruction has been proposed. The effective projective sequences of a structural component are obtained through the variable voltage. The total variation is adjusted and minimized to optimize the reconstructive results on the basis of iterative image using algebraic reconstruction technique (ART). In the process of reconstruction, the reconstructive image of low voltage is used as an initial value of the effective proiective reconstruction of the adjacent high voltage, and so on until to the highest voltage according to the gray weighted algorithm. Thereby the complete structural information is reconstructed. Simulation results show that the proposed algorithm can completely reflect the information of a complicated structural com- ponent, and the pixel values are more stable than those of the conventional.展开更多
Objective To evaluate the significance of multidetector CT 3D reconstruction technique inshowing anatomy of ethmoid sinus, at the same time, anatomic variations of ethmoid sinus and its clinical significance were also...Objective To evaluate the significance of multidetector CT 3D reconstruction technique inshowing anatomy of ethmoid sinus, at the same time, anatomic variations of ethmoid sinus and its clinical significance were also discussed. Methods 250 cases of ethmoid sinuses were scanned transversally by multidetector scaner, coronal and sagittal views were reconstructed. Results Coronal and sagittal views were good enough to make diagnosis. 5 kinds of common ethmoid sinus variations were seen, including pneumatization of ethmoid bulla (56. 5% ) , Onodi air cell(26% ) , Haller cell(6. 5% ) ,low ethmoid foveolas(4. 3% )and over intromigratiny lamella papyracea (6. 5% ). Conclusion The coronal and other special views of ethmoid sinus are showed clearly by 3D reconstruction which can provide detailed image informations for functional endoscopic sinus surgery.展开更多
文摘BACKGROUND Computed tomography(CT)small bowel three-dimensional(3D)reconstruction is a powerful tool for the diagnosis of small bowel disease and can clearly show the intestinal lumen and wall as well as the outside structure of the wall.The horizontal axis position can show the best adjacent intestinal tube and the lesion between the intestinal tubes,while the coronal position can show the overall view of the small bowel.The ileal end of the localization of the display of excellent,and easy to quantitative measurement of the affected intestinal segments,the sagittal position for the rectum and the pre-sacral lesions show the best,for the discovery of fistulae is also helpful.Sagittal view can show rectal and presacral lesions and is useful for fistula detection.It is suitable for the assessment of inflammatory bowel disease,such as assessment of disease severity and diagnosis and differential diagnosis of the small bowel and mesenteric space-occupying lesions as well as the judgment of small bowel obstruction points.CASE SUMMARY Bleeding caused by small intestinal polyps is often difficult to diagnose in clinical practice.This study reports a 29-year-old male patient who was admitted to the hospital with black stool and abdominal pain for 3 months.Using the combination of CT-3D reconstruction and capsule endoscopy,the condition was diagnosed correctly,and the polyps were removed using single-balloon enteroscopyendoscopic retrograde cholangiopancreatography without postoperative complications.CONCLUSION The role of CT-3D in gastrointestinal diseases was confirmed.CT-3D can assist in the diagnosis and treatment of gastrointestinal diseases in combination with capsule endoscopy and small intestinal microscopy.
文摘BACKGROUND Few reports have described living foreign bodies in the human body.The current manuscript demonstrates that computed tomography(CT)is an effective tool for accurate preoperative evaluation of living foreign bodies in clinic.The threedimensional(3D)reconstruction technology could clearly display anatomical structures,lesions and adjacent organs,improving diagnostic accuracy and guiding the surgical decision-making process.CASE SUMMARY Herein we describe a 68-year-old man diagnosed with digestive tract perforation and acute peritonitis caused by a foreign body of Monopterus albus.The patient pre-sented to the emergency department with complaints of dull abdominal pain,profuse sweating and a pale complexion during work.A Monopterus albus had entered the patient’s body through the anus two hours ago.During hospitalization,the 3D reconstruction technology revealed a perforation of the middle rectum complicated with acute peritonitis and showed a clear and complete Monopterus albus bone morphology in the abdominal and pelvic cavities,with the Monopterus albus biting the mesentery.Laparoscopic examination detected a large(diameter of about 1.5 cm)perforation in the mid-rectum.It could be seen that a Monopterus albus had completely entered the abdominal cavity and had tightly bitten the mesentery of the small intestine.During the operation,the dead Monopterus albus was taken out.CONCLUSION The current manuscript demonstrates that CT is an effective tool for accurate preoperative evaluation of living foreign bodies in clinic.
基金Project supported by the National Basic Research Program of China(Grant No.2006CB7057005)the National High Technology Research and Development Program of China(Grant No.2009AA012200)the National Natural Science Foundation of China (Grant No.60672104)
文摘With the development of the compressive sensing theory, the image reconstruction from the projections viewed in limited angles is one of the hot problems in the research of computed tomography technology. This paper develops an iterative algorithm for image reconstruction, which can fit the most cases. This method gives an image reconstruction flow with the difference image vector, which is based on the concept that the difference image vector between the reconstructed and the reference image is sparse enough. Then the l1-norm minimization method is used to reconstruct the difference vector to recover the image for flat subjects in limited angles. The algorithm has been tested with a thin planar phantom and a real object in limited-view projection data. Moreover, all the studies showed the satisfactory results in accuracy at a rather high reconstruction speed.
基金Project supported by the National Natural Science Foundation of China(Grant No.61372172)
文摘The additional sparse prior of images has been the subject of much research in problems of sparse-view computed tomography(CT) reconstruction. A method employing the image gradient sparsity is often used to reduce the sampling rate and is shown to remove the unwanted artifacts while preserve sharp edges, but may cause blocky or patchy artifacts.To eliminate this drawback, we propose a novel sparsity exploitation-based model for CT image reconstruction. In the presented model, the sparse representation and sparsity exploitation of both gradient and nonlocal gradient are investigated.The new model is shown to offer the potential for better results by introducing a similarity prior information of the image structure. Then, an effective alternating direction minimization algorithm is developed to optimize the objective function with a robust convergence result. Qualitative and quantitative evaluations have been carried out both on the simulation and real data in terms of accuracy and resolution properties. The results indicate that the proposed method can be applied for achieving better image-quality potential with the theoretically expected detailed feature preservation.
文摘BACKGROUND Primary adenoid cystic carcinoma in the trachea(TACC)is a rare tumour.Tracheal bronchoscopy is always chosen as a routine approach to obtain a pathological diagnosis,but it can be associated with an increased risk of asphyxia.CASE SUMMARY We describe a case of TACC in a patient evaluated by chest computed tomography(CT)with three-dimensional reconstruction imaging and diagnosed by transoesophageal endoscopic ultrasonography.The pathological diagnosis confirmed tracheal adenoid cystic carcinoma.CONCLUSION We highlight the importance of CT and provide a successful exploration of transoesophageal biopsy as a safe alternative approach.
基金National Natural Science Foundation of China(No.61471325)
文摘The traditional computed tomography(CT)reconstruction methods are noisy,low resolution,poor contrast,and generally not suitable to detect the smaller flaws.Besides,the filter design is also difficult.The CT characteristics reconstruction technology was brought forward to improve in these aspects,which is defined to directly reconstruct the characteristics of the projection for the best requirements not the overall image quality.The two-dimension(2D)and three-dimension(3D)CT characteristics reconstruction algorithm were firstly introduced,then by detailed analysis,experimental results and comparsion of parameters calculated,its advantages in keeping better high-frequency feature,better noise immunity,short time-consuming and easier design are verified.
文摘Objective To evaluate the clinical features,diagnosis,treatment,and outcome of intralobar pulmonary sequestration (ILS). Methods Patients who were diagnosed with ILS in our hospital between January 1988 and January 2009 were retrospectively reviewed. We recorded the clinical symptoms,imaging findings,operative technique,complications,and outcome of these patients. Results Forty-seven patients (25 men and 22 women) with an average age of 32.3 years were enrolled. Forty-two patients had symptoms including cough and hemoptysis. Chest X-ray,computed tomography (CT),magnetic resonance imaging (MRI),and angiography were performed. Thoracotomy was performed in 45 patients,while thoracoscopy was performed in 2 patients. Lobectomy was the most common treatment procedure. Massive bleeding developed in 2 patients due to injury of aberrant supplying artery intraoperatively,1 patient had atrial fibrillation,1 patient had thrombosis of upper extremity postoperatively. All patients were confirmed the diagnosis pathologically,4 accompanied with bronchogenic cyst,15 with bronchiectasis,8 with infection,2 with aspergilloma,and 1 with carcinoid. No late complications occurred. Conclusions ILS is rare,surgery is recommended because some patients may have potential severe complications. Contrast enhanced CT and three-dimensional reconstruction is the best diagnostic method. Both thoracotomy and thoracoscopy are appropriate for the selected candidates.
基金This work was supported by the Chinese Natural Science Foundation of China(No.60577016)the Foundation(No. 0512034)of Jiangxi Natural Science+1 种基金the Science and Technology Program(No. 2006-164)of Jiangxi Provincial Department of Educationthe Program(No.2005-314)of Key Laboratory of Nondestructive Testing Technology,Ministry of Education.
文摘Although emission spectral tomography (EST) combines emission spectral measurement with optical computed tomography (OCT), it is difficult to gain transient emission data from a large number of views, therefore, high precision OCT algorithms with few views ought to be studied for EST application. To improve the reconstruction precision in the case of few views, a new computed tomography reconstruction algorithm based on multipurpose optimal criterion and simulated annealing theory (multi-criterion simulated annealing reconstruction technique, MCSART) is proposed. This algorithm can suffice criterion of least squares, criterion of most uniformity, and criterion of most smoothness synchronously. We can get global optimal solution by MCSART algorithm with simulated annealing theory. The simulating experiment result shows that this algorithm is superior to the traditional algorithms under various noises.
文摘In conventional computed tomography (CT) reconstruction based on fixed voltage, the projective data often ap- pear overexposed or underexposed, as a result, the reconstructive results are poor. To solve this problem, variable voltage CT reconstruction has been proposed. The effective projective sequences of a structural component are obtained through the variable voltage. The total variation is adjusted and minimized to optimize the reconstructive results on the basis of iterative image using algebraic reconstruction technique (ART). In the process of reconstruction, the reconstructive image of low voltage is used as an initial value of the effective proiective reconstruction of the adjacent high voltage, and so on until to the highest voltage according to the gray weighted algorithm. Thereby the complete structural information is reconstructed. Simulation results show that the proposed algorithm can completely reflect the information of a complicated structural com- ponent, and the pixel values are more stable than those of the conventional.
文摘Objective To evaluate the significance of multidetector CT 3D reconstruction technique inshowing anatomy of ethmoid sinus, at the same time, anatomic variations of ethmoid sinus and its clinical significance were also discussed. Methods 250 cases of ethmoid sinuses were scanned transversally by multidetector scaner, coronal and sagittal views were reconstructed. Results Coronal and sagittal views were good enough to make diagnosis. 5 kinds of common ethmoid sinus variations were seen, including pneumatization of ethmoid bulla (56. 5% ) , Onodi air cell(26% ) , Haller cell(6. 5% ) ,low ethmoid foveolas(4. 3% )and over intromigratiny lamella papyracea (6. 5% ). Conclusion The coronal and other special views of ethmoid sinus are showed clearly by 3D reconstruction which can provide detailed image informations for functional endoscopic sinus surgery.