期刊文献+
共找到2篇文章
< 1 >
每页显示 20 50 100
Comparison of uniform resampling and nonuniform sampling direct-reconstruction methods in k-space for FD-OCT
1
作者 Yanrong Yang Yun Dai +1 位作者 Yuehua Zhou Yaliang Yang 《Journal of Innovative Optical Health Sciences》 SCIE EI CSCD 2023年第5期93-106,共14页
The nonuniform distribution of interference spectrum in wavenumber k-space is a key issue to limit the imaging quality of Fourier-domain optical coherence tomography(FD-OCT).At present,the reconstruction quality at di... The nonuniform distribution of interference spectrum in wavenumber k-space is a key issue to limit the imaging quality of Fourier-domain optical coherence tomography(FD-OCT).At present,the reconstruction quality at different depths among a variety of processing methods in k-space is still uncertain.Using simulated and experimental interference spectra at different depths,the effects of common six processing methods including uniform resampling(linear interpolation(LI),cubic spline interpolation(CSI),time-domain interpolation(TDI),and K-B window convolution)and nonuniform sampling direct-reconstruction(Lomb periodogram(LP)and nonuniform discrete Fourier transform(NDFT))on the reconstruction quality of FD-OCT were quantitatively analyzed and compared in this work.The results obtained by using simulated and experimental data were coincident.From the experimental results,the averaged peak intensity,axial resolution,and signal-to-noise ratio(SNR)of NDFT at depth from 0.5 to 3.0mm were improved by about 1.9 dB,1.4 times,and 11.8 dB,respectively,compared to the averaged indices of all the uniform resampling methods at all depths.Similarly,the improvements of the above three indices of LP were 2.0 dB,1.4 times,and 11.7 dB,respectively.The analysis method and the results obtained in this work are helpful to select an appropriate processing method in k-space,so as to improve the imaging quality of FD-OCT. 展开更多
关键词 Optical coherence tomography signal processing uniform resampling nonuniform sampling direct-reconstruction reconstruction quality.
下载PDF
Quality Evaluation of Image Recording Strategies for Limited Angle Tomography
2
作者 Fabian Stopp Christian Winne +1 位作者 Emanuel Jank Erwin Keeve 《Tsinghua Science and Technology》 SCIE EI CAS 2010年第1期25-29,共5页
In this paper we propose a new method for evaluating image recording strategies for limited angle tomography. In limited angle tomography exact three-dimensional (3-D) reconstruction is not achievable. With this met... In this paper we propose a new method for evaluating image recording strategies for limited angle tomography. In limited angle tomography exact three-dimensional (3-D) reconstruction is not achievable. With this method a metric for the reachable reconstruction quality by defined X-ray source trajectories is calculated. The result of our method is independent of reconstruction algorithms. Our approach is based on the gradients of the scanned volume and their grade of determinability. Compared to simulated reconstruction accuracy with simultaneous algebraic reconstruction techniques, the method of evaluation shows the same dependencies on X-ray source trajectories. By using the proposed method different source trajectories for a limited angle range are comparable with respect to the reachable reconstruction quality. 展开更多
关键词 3-D reconstruction quality intraoperative imaging limited angle tomography X-ray source trajectories
原文传递
上一页 1 下一页 到第