Inertial reference system is one of the airborne equipment.According to the requirements of SAE ARP4754A Guidelines for Development of Civil Aircraft and Systems,MC9 equipment qualification test is needed to verify th...Inertial reference system is one of the airborne equipment.According to the requirements of SAE ARP4754A Guidelines for Development of Civil Aircraft and Systems,MC9 equipment qualification test is needed to verify that the inertial reference system can perform reservation function under specified service conditions.That is,the inertial reference system shall pass certain environmental tests specified in DO⁃160G.Some tests are faced with the problem that the test equipment should have the function requirements of isolation protection and load simulation.Therefore,a kind of test equipment which can provide isolation protection and simulate load function in the test is designed.展开更多
An extended Kalman filter with adaptive gain was used to build a miniature attitude and heading reference system based on a stochastie model. The adaptive filter has six states with a time variable transition matrix. ...An extended Kalman filter with adaptive gain was used to build a miniature attitude and heading reference system based on a stochastie model. The adaptive filter has six states with a time variable transition matrix. When the system is in the non-acceleration mode, the accelerometer measurements of the gravity and the compass measurements of the heading have observability and yield good eslimates of the states. When the system is in the high dynamic mode and the bias has converged to an aceurate estimate, the attitude caleulation will be maintained for a long interval of time. The adaptive filter tunes its gain automatically based on the system dynamics sensed by the accelerometers to yield optimal performance,展开更多
This work presents a reference system overview to improve the efficiency of biological improvement of saline-alkali soil developed during the last thirty years, ranging from connotation, general methods and species, s...This work presents a reference system overview to improve the efficiency of biological improvement of saline-alkali soil developed during the last thirty years, ranging from connotation, general methods and species, soil desalination, soil structure, soil organic content, microbial flora, enzyme activity, yield and economic benefits. The reference system presented is divided into three main groups: suitable varieties, suitable cultivation measures, and a comprehensive evaluation system.There has been a lot of research on biological improvement of saline alkali soil, but these studies are very fragmented and lack a comprehensive standard system. Also, there is a lack of practical significance, particularly with regard to optimal species, densities and times of sowing for particular regions. On the other hand, the corresponding cultivation measure is very important. Therefore, a reference system plays an important role to the effect of biological improvement of saline alkali soil.展开更多
The <span style="font-family:Verdana;font-size:12px;">purpose of the research in this article is the examination of the agreement of the hypothesis of the absolute reference system with the results of ...The <span style="font-family:Verdana;font-size:12px;">purpose of the research in this article is the examination of the agreement of the hypothesis of the absolute reference system with the results of experiments that have been implemented in the past in order to confirm the special theory of relativity. To achieve this goal, we have chosen for discuss</span><span style="font-family:Verdana;">ing</span><span style="font-family:Verdana;"> a theoretical topic of electromagnetism, that of electromagnetic mass</span><span style="font-family:Verdana;"> calculation, and some experiments, some of which concern the transverse Doppler effect in a rotated system, two experiments that concern the kinetic energy measurement of accelerated electrons, one of which is the well known Bertozzis experiment, one experiment that concern</span><span style="font-family:Verdana;">s</span><span style="font-family:Verdana;"> the propagation of Coulomb fields and one more experiment that</span><span style="font-size:14pt;font-family:;" "=""> </span><span style="font-family:Verdana;">concern</span><span style="font-family:Verdana;">s</span><span style="font-family:Verdana;"> the effect of annihilation. The basic principles of the hypothesis of the absolute reference system, and the electromagnetic theory derived from these principles, are used to explain the experimental results. In these examples, the hypothesis of the absolute reference system is confirmed, since the experimental results agree with the predictions of this hypothesis. Also, in the discussion of calculation of electromagnetic mass is addressed the difficulty of solving this problem, when someone tr</span><span style="font-family:Verdana;">ies</span><span style="font-family:Verdana;"> to solve this according to the energy-mass relation of the theory of relativity.</span>展开更多
MEMS (micro electro mechanical systems) inertial navigation system ~, Mll'~3) nas Been WllUly used in robots for its low-cost. The MINS and magnetometers are commonly the component parts of the attitude and headin...MEMS (micro electro mechanical systems) inertial navigation system ~, Mll'~3) nas Been WllUly used in robots for its low-cost. The MINS and magnetometers are commonly the component parts of the attitude and heading reference systems (AHRS), which provide pitch and roll angles relative to the earth gravity vector, and heading angle relative to the north. However, the performance of sen- sors with low cost AHRS is not so good. The gyros are not sensitive enough to observe the earth an- gular velocity, so the traditional technique like alignment algorithm is invalid. The measurements of gyros become useless to determine the initial attitude matrix from navigation frame to body frame. The alignment algorithm is computed by the accelerometers and magnetometers. The process is es- tablished as an optimization problem of finding the maximum eigenvector. Meanwhile the sensitive analysis with respect to the biases of accelerometers is proposed. Then the recursive least squares al- gorithm (RLSA) is introduced. The comparison between the proposed method and RLSA is provid- ed. The results demonstrate its accuracy favorably and verify the feasibility of the proposed algo- rithm.展开更多
With the rapid development of techniques for astronomical observations, the precision of measurements has been significantly increasing. Theories describing astronomical relativistic reference systems, which are the f...With the rapid development of techniques for astronomical observations, the precision of measurements has been significantly increasing. Theories describing astronomical relativistic reference systems, which are the foundation for processing and interpreting these data now and in the future, may require extensions to satisfy the needs of these trends. Besides building a framework compatible with alternative theories of gravity and the pursuit of higher order post-Newtonian approximation, it will also be necessary to make the first order post-Newtonian multipole moments of celestial bodies be explicitly expressed in the astronomical relativistic reference systems. This will bring some convenience into modeling the observations and experiments and make it easier to distinguish different contributions in measurements. As a first step, the global solar system reference system is expressed as a multipolar expansion and the post-Newtonian mass and spin moments are shown explicitly in the metric which describes the coordinates of the system. The full expression of the global metric is given.展开更多
In the fields of earth observation,deep space detection,laser communication,and directional energyweapon,the target needs to be observed and pointed at accurately.Acquisition,tracking,and pointing(ATP)systems are usua...In the fields of earth observation,deep space detection,laser communication,and directional energyweapon,the target needs to be observed and pointed at accurately.Acquisition,tracking,and pointing(ATP)systems are usually designed to stabilize the line of sight(LOS)within sub-micro radian levels.In the case of an ATP system mounted on a mobile platform,angular disturbances experienced by the mobile platform will seriously affect the LOS.To overcome the problemthat the sampling frequency of detectors is usually limited and achieving several hundreds of hertz is difficult,thewide-bandwidth inertial reference system(WBIRS)and fast steeringmirror are usually integrated into ATP systems to mitigate these angular disturbances.To reduce the structural stress,a flexible support providing two rotational degrees of freedomis usually adopted for the system.However,the occurrence of resonant points within the bandwidthwill be inevitable.Measurements have to be taken to compensate these low-frequency resonant points to realize a wide bandwidth and high precision.In this paper,the lowfrequency resonant points of a systemwere simulated using finite element analysis and tested by a systemidentification method.The results show that the first-order resonance happened at 34.5 Hz with a gain of 28 dB.An improved double-T notch filter was designed and applied in a real-time system to suppress the resonance at 34.5 Hz.The experimental results show that the resonance was significantly suppressed.In particular,the resonance peak was reduced by 79.37%.In addition,the closed-loop system settling time was reduced by 36.2%.展开更多
Several active damping methods corresponding to various reference systems are discussed.The theoretical analyses show that a quasi-fixed reference system can be used to improve the high-frequency performance of a mult...Several active damping methods corresponding to various reference systems are discussed.The theoretical analyses show that a quasi-fixed reference system can be used to improve the high-frequency performance of a multi-stage active damping system because its high-frequency performance is equivalent to that of a low-pass electronic filter with a very low cut-off frequency.展开更多
The detection performance is evaluated for our proposed analog multiuser receiver in Ultra-WideBand (UWB) transmitted-reference system. In the presence of dense multipath and multi-access signals,the performance analy...The detection performance is evaluated for our proposed analog multiuser receiver in Ultra-WideBand (UWB) transmitted-reference system. In the presence of dense multipath and multi-access signals,the performance analysis is difficult due to the complicated waveform of received impulse. We develop an approach to analyze the steady-state Signal-to-Interference-plus-Noise (SINR) of the detector output. The multipath-spread impulse is fitted to an exponentially decaying profile in the analysis. A closed-form expression of steady-state SINR is further deduced for the proposed Least Minimum Square (LMS) detector. The analysis is validated by simulations in Line-Of-Sight (LOS) and Non-Line-Of-Sight (NLOS) channel respectively. Based on the theoretical results,the multipath delay spread is employed to determine the optimal width of the integration window of the detector.展开更多
In low-cost Attitude Heading Reference Systems (AHRS), the measurements made by Micro Electro-Mechanical Systems (MEMS) type sensors are affected by uncertainties, noises and unknown disturbances. In this paper, consi...In low-cost Attitude Heading Reference Systems (AHRS), the measurements made by Micro Electro-Mechanical Systems (MEMS) type sensors are affected by uncertainties, noises and unknown disturbances. In this paper, considering the robustness of sliding mode observers against structured and unstructured uncertainties, and also exogenous inputs, the process of design and implementation of a sliding mode observer (SMO) is proposed based on a linearized model of the AHRS. To decrease the chattering phenomenon is the main difficulty of the SMO. Through smoothing the discontinuity term, the tracking performance of the observer is attenuated. Boundary layer technique, for example, using a saturation term, is the common smoother to remove the chattering drawbacks. However, through poor tracking performance, the high range chattering could not be removed by this method. Therefore, a knowledge-based Mamdani-type fuzzy SMO (FSMO) is proposed to decrease the chattering effects intelligently, which in turn could obtain the high accuracy tracking performance of the SMO. Following proving the stability of the proposed SMOs based on direct Lyapunov’s method, the performance of the proposed observers is compared with that of the extended Kalman filter through simulation and real experiments of an AHRS.展开更多
The problem of prescribed performance tracking control for unknown time-delay nonlinear systems subject to output constraints is dealt with in this paper. In contrast with related works, only the most fundamental requ...The problem of prescribed performance tracking control for unknown time-delay nonlinear systems subject to output constraints is dealt with in this paper. In contrast with related works, only the most fundamental requirements, i.e., boundedness and the local Lipschitz condition, are assumed for the allowable time delays. Moreover, we focus on the case where the reference is unknown beforehand, which renders the standard prescribed performance control designs under output constraints infeasible. To conquer these challenges, a novel robust prescribed performance control approach is put forward in this paper.Herein, a reverse tuning function is skillfully constructed and automatically generates a performance envelop for the tracking error. In addition, a unified performance analysis framework based on proof by contradiction and the barrier function is established to reveal the inherent robustness of the control system against the time delays. It turns out that the system output tracks the reference with a preassigned settling time and good accuracy,without constraint violations. A comparative simulation on a two-stage chemical reactor is carried out to illustrate the above theoretical findings.展开更多
A Beidou 3(BD3)system-based power reference station can provide high-precision time synchronization for power distribution systems by sending synchronization data packets to devices in a multi-hop routing fashion.Howe...A Beidou 3(BD3)system-based power reference station can provide high-precision time synchronization for power distribution systems by sending synchronization data packets to devices in a multi-hop routing fashion.However,optimizing route selection to reduce both time synchronization error and delay is a challenging problem.In this paper,we establish a software-defined network-enabled power reference station time synchronization framework based on BD3.Then,we formulate the joint problem to minimize cumulative synchronization error and delay through multi-hop route selection optimization.A back propagation(BP)neural network-improved intelligent time synchronization route selection algorithm named BP-RS is proposed to learn the optimal route selection,which uses a BP neural network to dynamically adjust the exploration factor to achieve rapid convergence.Simulation results show the superior performance of BP-RS in synchronization delay,synchronization error,and adaptability with changing routing topologies.展开更多
Natural gas (NG) is one of the most important sources of energy for industrial and domestic consumption in the present era because it is cheap and free from sulfur impurities. Therefore, accurate and precise measureme...Natural gas (NG) is one of the most important sources of energy for industrial and domestic consumption in the present era because it is cheap and free from sulfur impurities. Therefore, accurate and precise measurement of its composition is of fundamental importance for trade reasons. To improve the quality of NG gas measurements, certified reference materials (CRMs) should be used for calibration of measuring equipment in order to ensure the traceability of the measurement results to the SI units. For the traceability purpose, a multicomponent natural gas mixture was prepared gravimetrically as a reference material according to ISO 6142 from pure helium, hydrogen, n-pentane, i-pentane, n-butane, i-butane, propane, ethane, hexane, methane and nitrogen. The preparation was done in two dilution steps in 5 L aluminum cylinders. The calculated mole fractions and associated uncertainties of natural gas components were verified by a dual GC-FID/TCD system in accordance with ISO 6143 calibrated by a series of primary gas mixtures (CRMs) produced by an NMI. The results obtained by gravimetry and by GC measurements have been checked for compatibility as required by ISO 6142 and were found in very good agreement. Details of the preparation and calculation of the mole fractions and uncertainties of all gas components are explained in this article.展开更多
VIGS(Virus-induced gene silencing),a method for posttranscriptional gene silencing,is an effective technique for investigating the activities of genes in plants.Since there is no report for available VIGS system in St...VIGS(Virus-induced gene silencing),a method for posttranscriptional gene silencing,is an effective technique for investigating the activities of genes in plants.Since there is no report for available VIGS system in Styrax japonicus,the application of a VIGS approach that results in a gene knockdown to study gene function is limited.In this study,we compared the characteristics that could affect the viability of VIGS in S.japonicus,including the acetosyringone(AS)concentration,the Agrobacterium’s optical density and the inoculation method.The stable reference genes of S.japonicus were selected to validate the gene’s knockdown by quantitative PCR.As a result,we successfully constructed 2 VIGS systems based on TRV virus:vacuum with AS concentration of 200μmol·L^(-1)and OD600of 0.5,and friction-osmosis with AS concentration of 200μmol·L^(-1)and OD600of 1.0,which silencing efficiency was 83.33%and 74.19%,respectively.The successfully applied VIGS method provides a rapid and effective reverse gene functional analysis approach in S.japonicus to identify unknown gene functions.展开更多
BACKGROUND Validation of the reference gene(RG)stability during experimental analyses is essential for correct quantitative real-time polymerase chain reaction(RT-qPCR)data normalisation.Commonly,in an unreliable way,...BACKGROUND Validation of the reference gene(RG)stability during experimental analyses is essential for correct quantitative real-time polymerase chain reaction(RT-qPCR)data normalisation.Commonly,in an unreliable way,several studies use genes involved in essential cellular functions[glyceraldehyde-3-phosphate dehydro-genase(GAPDH),18S rRNA,andβ-actin]without paying attention to whether they are suitable for such experimental conditions or the reason for choosing such genes.Furthermore,such studies use only one gene when Minimum Information for Publication of Quantitative Real-Time PCR Experiments guidelines recom-mend two or more genes.It impacts the credibility of these studies and causes dis-tortions in the gene expression findings.For tissue engineering,the accuracy of gene expression drives the best experimental or therapeutical approaches.We cultivated DPSCs under two conditions:Undifferentiated and osteogenic dif-ferentiation,both for 35 d.We evaluated the gene expression of 10 candidates for RGs[ribosomal protein,large,P0(RPLP0),TATA-binding protein(TBP),GAPDH,actin beta(ACTB),tubulin(TUB),aminolevulinic acid synthase 1(ALAS1),tyro-sine 3-monooxygenase/tryptophan 5-monooxygenase activation protein,zeta(YWHAZ),eukaryotic translational elongation factor 1 alpha(EF1a),succinate dehydrogenase complex,subunit A,flavoprotein(SDHA),and beta-2-micro-globulin(B2M)]every 7 d(1,7,14,21,28,and 35 d)by RT-qPCR.The data were analysed by the four main algorithms,ΔCt method,geNorm,NormFinder,and BestKeeper and ranked by the RefFinder method.We subdivided the samples into eight subgroups.RESULTS All of the data sets from clonogenic and osteogenic samples were analysed using the RefFinder algorithm.The final ranking showed RPLP0/TBP as the two most stable RGs and TUB/B2M as the two least stable RGs.Either theΔCt method or NormFinder analysis showed TBP/RPLP0 as the two most stable genes.However,geNorm analysis showed RPLP0/EF1αin the first place.These algorithms’two least stable RGs were B2M/GAPDH.For BestKeeper,ALAS1 was ranked as the most stable RG,and SDHA as the least stable RG.The pair RPLP0/TBP was detected in most subgroups as the most stable RGs,following the RefFinfer ranking.CONCLUSION For the first time,we show that RPLP0/TBP are the most stable RGs,whereas TUB/B2M are unstable RGs for long-term osteogenic differentiation of human DPSCs in traditional monolayers.展开更多
Channel equalization plays a pivotal role within the reconstruction phase of passive radar reference signals.In the context of reconstructing digital terrestrial multimedia broadcasting(DTMB)signals for low-slow-small...Channel equalization plays a pivotal role within the reconstruction phase of passive radar reference signals.In the context of reconstructing digital terrestrial multimedia broadcasting(DTMB)signals for low-slow-small(LSS)target detection,a novel frequency domain block joint equalization algorithm is presented in this article.From the DTMB signal frame structure and channel multipath transmission characteristics,this article adopts a unconventional approach where the delay and frame structure of each DTMB signal frame are reconfigured to create a circular convolution block,facilitating concurrent fast Fourier transform(FFT)calculations.Following equalization,an inverse fast Fourier transform(IFFT)-based joint output and subsequent data reordering are executed to finalize the equalization process for the DTMB signal.Simulation and measured data confirm that this algorithm outperforms conventional techniques by reducing signal errors rate and enhancing real-time processing.In passive radar LSS detection,it effectively suppresses multipath and noise through frequency domain equalization,reducing false alarms and improving the capabilities of weak target detection.展开更多
Purpose – Straightness measurement of rail weld joint is of essential importance to railway maintenance. Dueto the lack of efficient measurement equipment, there has been limited in-depth research on rail weld joint ...Purpose – Straightness measurement of rail weld joint is of essential importance to railway maintenance. Dueto the lack of efficient measurement equipment, there has been limited in-depth research on rail weld joint with a5-m wavelength range, leaving a significant knowledge gap in this field.Design/methodology/approach – In this study, the authors used the well-established inertial referencemethod (IR-method), and the state-of-the-art multi-point chord reference method (MCR-method). Two methodshave been applied in different types of rail straightness measurement trollies, respectively. These instrumentswere tested in a high-speed rail section within a certain region of China. The test results were ultimatelyvalidated through using traditional straightedge and feeler gauge methods as reference data to evaluate the railweld joint straightness within the 5-m wavelength range.Findings – The research reveals that IR-method and MCR-method produce reasonably similar measurementresults for wavelengths below 1 m. However, MCR-method outperforms IR-method in terms of accuracy forwavelengths exceeding 3 m. Furthermore, it was observed that IR-method, while operating at a slower speed,carries the risk of derailing and is incapable of detecting rail weld joints and low joints within the track.Originality/value – The research compare two methods’ measurement effects in a longer wavelength rangeand demonstrate the superiority of MCR-method.展开更多
[Objectives]To study the reference value of thyroid function in healthy women of childbearing age during different pregnancies(early,middle and late pregnancy)in Jingzhou City.[Methods]362 healthy women of childbearin...[Objectives]To study the reference value of thyroid function in healthy women of childbearing age during different pregnancies(early,middle and late pregnancy)in Jingzhou City.[Methods]362 healthy women of childbearing age during different pregnancies(early,middle and late pregnancy)were selected as the study group,and 360 non-pregnant women were selected as the control group.Serum thyroid hormone levels in the two groups were detected,and the reference value was expressed as the median(M)and 95%confidence interval(CI).On this basis,the chart of changing trend of thyroid hormone in the early,middle and late pregnancy were plotted.[Results]Compared with the control group,FT3,TT4,TT3,FT4and TSH in the early,middle and late pregnancy were significantly different in the study group(P<0.05).In the study group,there were significant differences in the early,middle and late pregnancy(P<0.05).[Conclusions]This trend chart has certain reference value in the screening,diagnosis and treatment of thyroid diseases in healthy women of childbearing age during different pregnancies(early,middle and late pregnancy)in Jingzhou City of Hubei Province.展开更多
It is still a huge challenge for traditional Pareto-dominatedmany-objective optimization algorithms to solve manyobjective optimization problems because these algorithms hardly maintain the balance between convergence...It is still a huge challenge for traditional Pareto-dominatedmany-objective optimization algorithms to solve manyobjective optimization problems because these algorithms hardly maintain the balance between convergence and diversity and can only find a group of solutions focused on a small area on the Pareto front,resulting in poor performance of those algorithms.For this reason,we propose a reference vector-assisted algorithmwith an adaptive niche dominance relation,for short MaOEA-AR.The new dominance relation forms a niche based on the angle between candidate solutions.By comparing these solutions,the solutionwith the best convergence is found to be the non-dominated solution to improve the selection pressure.In reproduction,a mutation strategy of k-bit crossover and hybrid mutation is used to generate high-quality offspring.On 23 test problems with up to 15-objective,we compared the proposed algorithm with five state-of-the-art algorithms.The experimental results verified that the proposed algorithm is competitive.展开更多
The objectives of this work were to evaluate the surgical activities carried out in the general surgery department of the Reference Health Center of Commune I of Bamako, to describe the sociodemographic characteristic...The objectives of this work were to evaluate the surgical activities carried out in the general surgery department of the Reference Health Center of Commune I of Bamako, to describe the sociodemographic characteristics of the operated patients, to determine the main pathologies encountered and to evaluate qualitatively the result of the treatment. In order to improve performance, and the quality of care, and to identify common pathologies in the surgical department, we undertook a retrospective study on surgical activities from January 2009 to December 2010. At the end of this study, out of 474 men and 187 women (equal sex ratio 2.53);we were able to determine the frequency of surgical pathologies. Farmers, housewives and pupils/students were the most represented with 25.9% respectively;20% and 13.3%. The most frequently observed pathologies were wall hernia (44.8%), prostate adenoma (12%) and acute appendicitis (10.5%). The average length of hospitalization was 3.43 days. Infectious complications affected 25 patients (3.8% of cases) and a death rate of 0.45% (i.e. 3 patients). The average cost of care was 53,500 FCFA. Indeed, the reality of surgical practice in health centers was not the same because of the level of skills of practicing surgeons.展开更多
文摘Inertial reference system is one of the airborne equipment.According to the requirements of SAE ARP4754A Guidelines for Development of Civil Aircraft and Systems,MC9 equipment qualification test is needed to verify that the inertial reference system can perform reservation function under specified service conditions.That is,the inertial reference system shall pass certain environmental tests specified in DO⁃160G.Some tests are faced with the problem that the test equipment should have the function requirements of isolation protection and load simulation.Therefore,a kind of test equipment which can provide isolation protection and simulate load function in the test is designed.
文摘An extended Kalman filter with adaptive gain was used to build a miniature attitude and heading reference system based on a stochastie model. The adaptive filter has six states with a time variable transition matrix. When the system is in the non-acceleration mode, the accelerometer measurements of the gravity and the compass measurements of the heading have observability and yield good eslimates of the states. When the system is in the high dynamic mode and the bias has converged to an aceurate estimate, the attitude caleulation will be maintained for a long interval of time. The adaptive filter tunes its gain automatically based on the system dynamics sensed by the accelerometers to yield optimal performance,
基金project is supported by the National Key R&D Program of China (No. 2016YFC0501307)the Key R&D Program of Ningxia Hui Autonomous Region (No. 2018BBF23008)
文摘This work presents a reference system overview to improve the efficiency of biological improvement of saline-alkali soil developed during the last thirty years, ranging from connotation, general methods and species, soil desalination, soil structure, soil organic content, microbial flora, enzyme activity, yield and economic benefits. The reference system presented is divided into three main groups: suitable varieties, suitable cultivation measures, and a comprehensive evaluation system.There has been a lot of research on biological improvement of saline alkali soil, but these studies are very fragmented and lack a comprehensive standard system. Also, there is a lack of practical significance, particularly with regard to optimal species, densities and times of sowing for particular regions. On the other hand, the corresponding cultivation measure is very important. Therefore, a reference system plays an important role to the effect of biological improvement of saline alkali soil.
文摘The <span style="font-family:Verdana;font-size:12px;">purpose of the research in this article is the examination of the agreement of the hypothesis of the absolute reference system with the results of experiments that have been implemented in the past in order to confirm the special theory of relativity. To achieve this goal, we have chosen for discuss</span><span style="font-family:Verdana;">ing</span><span style="font-family:Verdana;"> a theoretical topic of electromagnetism, that of electromagnetic mass</span><span style="font-family:Verdana;"> calculation, and some experiments, some of which concern the transverse Doppler effect in a rotated system, two experiments that concern the kinetic energy measurement of accelerated electrons, one of which is the well known Bertozzis experiment, one experiment that concern</span><span style="font-family:Verdana;">s</span><span style="font-family:Verdana;"> the propagation of Coulomb fields and one more experiment that</span><span style="font-size:14pt;font-family:;" "=""> </span><span style="font-family:Verdana;">concern</span><span style="font-family:Verdana;">s</span><span style="font-family:Verdana;"> the effect of annihilation. The basic principles of the hypothesis of the absolute reference system, and the electromagnetic theory derived from these principles, are used to explain the experimental results. In these examples, the hypothesis of the absolute reference system is confirmed, since the experimental results agree with the predictions of this hypothesis. Also, in the discussion of calculation of electromagnetic mass is addressed the difficulty of solving this problem, when someone tr</span><span style="font-family:Verdana;">ies</span><span style="font-family:Verdana;"> to solve this according to the energy-mass relation of the theory of relativity.</span>
基金Supported by the National Natural Science Foundation of China(No.60905056)
文摘MEMS (micro electro mechanical systems) inertial navigation system ~, Mll'~3) nas Been WllUly used in robots for its low-cost. The MINS and magnetometers are commonly the component parts of the attitude and heading reference systems (AHRS), which provide pitch and roll angles relative to the earth gravity vector, and heading angle relative to the north. However, the performance of sen- sors with low cost AHRS is not so good. The gyros are not sensitive enough to observe the earth an- gular velocity, so the traditional technique like alignment algorithm is invalid. The measurements of gyros become useless to determine the initial attitude matrix from navigation frame to body frame. The alignment algorithm is computed by the accelerometers and magnetometers. The process is es- tablished as an optimization problem of finding the maximum eigenvector. Meanwhile the sensitive analysis with respect to the biases of accelerometers is proposed. Then the recursive least squares al- gorithm (RLSA) is introduced. The comparison between the proposed method and RLSA is provid- ed. The results demonstrate its accuracy favorably and verify the feasibility of the proposed algo- rithm.
基金Supported by the National Natural Science Foundation of China
文摘With the rapid development of techniques for astronomical observations, the precision of measurements has been significantly increasing. Theories describing astronomical relativistic reference systems, which are the foundation for processing and interpreting these data now and in the future, may require extensions to satisfy the needs of these trends. Besides building a framework compatible with alternative theories of gravity and the pursuit of higher order post-Newtonian approximation, it will also be necessary to make the first order post-Newtonian multipole moments of celestial bodies be explicitly expressed in the astronomical relativistic reference systems. This will bring some convenience into modeling the observations and experiments and make it easier to distinguish different contributions in measurements. As a first step, the global solar system reference system is expressed as a multipolar expansion and the post-Newtonian mass and spin moments are shown explicitly in the metric which describes the coordinates of the system. The full expression of the global metric is given.
基金supported by the Research on Key Problems of Wide-band Inertial Reference Based on Magnetohydrodynamics (Grant number 61733012)National Natural Science Foundation of China Youth Project (Grant number 61703303)+2 种基金Tianjin Natural Science Foundation Youth Project (Grant number No. 17JCQNJCo4100)State Key Laboratory of Precision Testing Technology and Instruments Open Project (Grant number No. PILAB1705)2017 Tianjin Education Commission Research Project (Grant number 2017KJ086)
文摘In the fields of earth observation,deep space detection,laser communication,and directional energyweapon,the target needs to be observed and pointed at accurately.Acquisition,tracking,and pointing(ATP)systems are usually designed to stabilize the line of sight(LOS)within sub-micro radian levels.In the case of an ATP system mounted on a mobile platform,angular disturbances experienced by the mobile platform will seriously affect the LOS.To overcome the problemthat the sampling frequency of detectors is usually limited and achieving several hundreds of hertz is difficult,thewide-bandwidth inertial reference system(WBIRS)and fast steeringmirror are usually integrated into ATP systems to mitigate these angular disturbances.To reduce the structural stress,a flexible support providing two rotational degrees of freedomis usually adopted for the system.However,the occurrence of resonant points within the bandwidthwill be inevitable.Measurements have to be taken to compensate these low-frequency resonant points to realize a wide bandwidth and high precision.In this paper,the lowfrequency resonant points of a systemwere simulated using finite element analysis and tested by a systemidentification method.The results show that the first-order resonance happened at 34.5 Hz with a gain of 28 dB.An improved double-T notch filter was designed and applied in a real-time system to suppress the resonance at 34.5 Hz.The experimental results show that the resonance was significantly suppressed.In particular,the resonance peak was reduced by 79.37%.In addition,the closed-loop system settling time was reduced by 36.2%.
基金Supported by the National Natural Science Foundation of China under Grant Nos.19425008 and 49674246.
文摘Several active damping methods corresponding to various reference systems are discussed.The theoretical analyses show that a quasi-fixed reference system can be used to improve the high-frequency performance of a multi-stage active damping system because its high-frequency performance is equivalent to that of a low-pass electronic filter with a very low cut-off frequency.
基金Supported by the Guangxi Natural Science Foundation (No.0731025, No.0731026)the Established Project by Guangxi Education Department (No.200808LX117)
文摘The detection performance is evaluated for our proposed analog multiuser receiver in Ultra-WideBand (UWB) transmitted-reference system. In the presence of dense multipath and multi-access signals,the performance analysis is difficult due to the complicated waveform of received impulse. We develop an approach to analyze the steady-state Signal-to-Interference-plus-Noise (SINR) of the detector output. The multipath-spread impulse is fitted to an exponentially decaying profile in the analysis. A closed-form expression of steady-state SINR is further deduced for the proposed Least Minimum Square (LMS) detector. The analysis is validated by simulations in Line-Of-Sight (LOS) and Non-Line-Of-Sight (NLOS) channel respectively. Based on the theoretical results,the multipath delay spread is employed to determine the optimal width of the integration window of the detector.
文摘In low-cost Attitude Heading Reference Systems (AHRS), the measurements made by Micro Electro-Mechanical Systems (MEMS) type sensors are affected by uncertainties, noises and unknown disturbances. In this paper, considering the robustness of sliding mode observers against structured and unstructured uncertainties, and also exogenous inputs, the process of design and implementation of a sliding mode observer (SMO) is proposed based on a linearized model of the AHRS. To decrease the chattering phenomenon is the main difficulty of the SMO. Through smoothing the discontinuity term, the tracking performance of the observer is attenuated. Boundary layer technique, for example, using a saturation term, is the common smoother to remove the chattering drawbacks. However, through poor tracking performance, the high range chattering could not be removed by this method. Therefore, a knowledge-based Mamdani-type fuzzy SMO (FSMO) is proposed to decrease the chattering effects intelligently, which in turn could obtain the high accuracy tracking performance of the SMO. Following proving the stability of the proposed SMOs based on direct Lyapunov’s method, the performance of the proposed observers is compared with that of the extended Kalman filter through simulation and real experiments of an AHRS.
基金supported in part by the National Natural Science Foundation of China (62103093)the National Key Research and Development Program of China (2022YFB3305905)+6 种基金the Xingliao Talent Program of Liaoning Province of China (XLYC2203130)the Fundamental Research Funds for the Central Universities of China (N2108003)the Natural Science Foundation of Liaoning Province (2023-MS-087)the BNU Talent Seed Fund,UIC Start-Up Fund (R72021115)the Guangdong Key Laboratory of AI and MM Data Processing (2020KSYS007)the Guangdong Provincial Key Laboratory IRADS for Data Science (2022B1212010006)the Guangdong Higher Education Upgrading Plan 2021–2025 of “Rushing to the Top,Making Up Shortcomings and Strengthening Special Features” with UIC Research,China (R0400001-22,R0400025-21)。
文摘The problem of prescribed performance tracking control for unknown time-delay nonlinear systems subject to output constraints is dealt with in this paper. In contrast with related works, only the most fundamental requirements, i.e., boundedness and the local Lipschitz condition, are assumed for the allowable time delays. Moreover, we focus on the case where the reference is unknown beforehand, which renders the standard prescribed performance control designs under output constraints infeasible. To conquer these challenges, a novel robust prescribed performance control approach is put forward in this paper.Herein, a reverse tuning function is skillfully constructed and automatically generates a performance envelop for the tracking error. In addition, a unified performance analysis framework based on proof by contradiction and the barrier function is established to reveal the inherent robustness of the control system against the time delays. It turns out that the system output tracks the reference with a preassigned settling time and good accuracy,without constraint violations. A comparative simulation on a two-stage chemical reactor is carried out to illustrate the above theoretical findings.
基金supported by the Science and Technology Project of the China Southern Power Grid Company Limited under grant number GDKJXM20202032。
文摘A Beidou 3(BD3)system-based power reference station can provide high-precision time synchronization for power distribution systems by sending synchronization data packets to devices in a multi-hop routing fashion.However,optimizing route selection to reduce both time synchronization error and delay is a challenging problem.In this paper,we establish a software-defined network-enabled power reference station time synchronization framework based on BD3.Then,we formulate the joint problem to minimize cumulative synchronization error and delay through multi-hop route selection optimization.A back propagation(BP)neural network-improved intelligent time synchronization route selection algorithm named BP-RS is proposed to learn the optimal route selection,which uses a BP neural network to dynamically adjust the exploration factor to achieve rapid convergence.Simulation results show the superior performance of BP-RS in synchronization delay,synchronization error,and adaptability with changing routing topologies.
文摘Natural gas (NG) is one of the most important sources of energy for industrial and domestic consumption in the present era because it is cheap and free from sulfur impurities. Therefore, accurate and precise measurement of its composition is of fundamental importance for trade reasons. To improve the quality of NG gas measurements, certified reference materials (CRMs) should be used for calibration of measuring equipment in order to ensure the traceability of the measurement results to the SI units. For the traceability purpose, a multicomponent natural gas mixture was prepared gravimetrically as a reference material according to ISO 6142 from pure helium, hydrogen, n-pentane, i-pentane, n-butane, i-butane, propane, ethane, hexane, methane and nitrogen. The preparation was done in two dilution steps in 5 L aluminum cylinders. The calculated mole fractions and associated uncertainties of natural gas components were verified by a dual GC-FID/TCD system in accordance with ISO 6143 calibrated by a series of primary gas mixtures (CRMs) produced by an NMI. The results obtained by gravimetry and by GC measurements have been checked for compatibility as required by ISO 6142 and were found in very good agreement. Details of the preparation and calculation of the mole fractions and uncertainties of all gas components are explained in this article.
基金supported by the Subject of Key R&D Plan of Shandong Province(Major Scientific and Technological Innovation Project)“Mining and Accurate Identification of Forest Tree Germplasm Resources”(Grant Nos.2021LZGC02303)Science&Technology Specific Projects in Agricultural High-tech Industrial Demonstration Area of the Yellow River Delta(Grant No.022SZX16)。
文摘VIGS(Virus-induced gene silencing),a method for posttranscriptional gene silencing,is an effective technique for investigating the activities of genes in plants.Since there is no report for available VIGS system in Styrax japonicus,the application of a VIGS approach that results in a gene knockdown to study gene function is limited.In this study,we compared the characteristics that could affect the viability of VIGS in S.japonicus,including the acetosyringone(AS)concentration,the Agrobacterium’s optical density and the inoculation method.The stable reference genes of S.japonicus were selected to validate the gene’s knockdown by quantitative PCR.As a result,we successfully constructed 2 VIGS systems based on TRV virus:vacuum with AS concentration of 200μmol·L^(-1)and OD600of 0.5,and friction-osmosis with AS concentration of 200μmol·L^(-1)and OD600of 1.0,which silencing efficiency was 83.33%and 74.19%,respectively.The successfully applied VIGS method provides a rapid and effective reverse gene functional analysis approach in S.japonicus to identify unknown gene functions.
基金Supported by São Paulo Research Foundation(FAPESP),No.2010/08918-9 and 2020/11564-6the KBSP Young Investigator Fellowship,No.2011/00204-0+2 种基金the DBF Fellowship,No.2019/27492-7the LMG Fellowship,No.2014/01395-1the CFB Fellowship,No.2014/14278-3.
文摘BACKGROUND Validation of the reference gene(RG)stability during experimental analyses is essential for correct quantitative real-time polymerase chain reaction(RT-qPCR)data normalisation.Commonly,in an unreliable way,several studies use genes involved in essential cellular functions[glyceraldehyde-3-phosphate dehydro-genase(GAPDH),18S rRNA,andβ-actin]without paying attention to whether they are suitable for such experimental conditions or the reason for choosing such genes.Furthermore,such studies use only one gene when Minimum Information for Publication of Quantitative Real-Time PCR Experiments guidelines recom-mend two or more genes.It impacts the credibility of these studies and causes dis-tortions in the gene expression findings.For tissue engineering,the accuracy of gene expression drives the best experimental or therapeutical approaches.We cultivated DPSCs under two conditions:Undifferentiated and osteogenic dif-ferentiation,both for 35 d.We evaluated the gene expression of 10 candidates for RGs[ribosomal protein,large,P0(RPLP0),TATA-binding protein(TBP),GAPDH,actin beta(ACTB),tubulin(TUB),aminolevulinic acid synthase 1(ALAS1),tyro-sine 3-monooxygenase/tryptophan 5-monooxygenase activation protein,zeta(YWHAZ),eukaryotic translational elongation factor 1 alpha(EF1a),succinate dehydrogenase complex,subunit A,flavoprotein(SDHA),and beta-2-micro-globulin(B2M)]every 7 d(1,7,14,21,28,and 35 d)by RT-qPCR.The data were analysed by the four main algorithms,ΔCt method,geNorm,NormFinder,and BestKeeper and ranked by the RefFinder method.We subdivided the samples into eight subgroups.RESULTS All of the data sets from clonogenic and osteogenic samples were analysed using the RefFinder algorithm.The final ranking showed RPLP0/TBP as the two most stable RGs and TUB/B2M as the two least stable RGs.Either theΔCt method or NormFinder analysis showed TBP/RPLP0 as the two most stable genes.However,geNorm analysis showed RPLP0/EF1αin the first place.These algorithms’two least stable RGs were B2M/GAPDH.For BestKeeper,ALAS1 was ranked as the most stable RG,and SDHA as the least stable RG.The pair RPLP0/TBP was detected in most subgroups as the most stable RGs,following the RefFinfer ranking.CONCLUSION For the first time,we show that RPLP0/TBP are the most stable RGs,whereas TUB/B2M are unstable RGs for long-term osteogenic differentiation of human DPSCs in traditional monolayers.
文摘Channel equalization plays a pivotal role within the reconstruction phase of passive radar reference signals.In the context of reconstructing digital terrestrial multimedia broadcasting(DTMB)signals for low-slow-small(LSS)target detection,a novel frequency domain block joint equalization algorithm is presented in this article.From the DTMB signal frame structure and channel multipath transmission characteristics,this article adopts a unconventional approach where the delay and frame structure of each DTMB signal frame are reconfigured to create a circular convolution block,facilitating concurrent fast Fourier transform(FFT)calculations.Following equalization,an inverse fast Fourier transform(IFFT)-based joint output and subsequent data reordering are executed to finalize the equalization process for the DTMB signal.Simulation and measured data confirm that this algorithm outperforms conventional techniques by reducing signal errors rate and enhancing real-time processing.In passive radar LSS detection,it effectively suppresses multipath and noise through frequency domain equalization,reducing false alarms and improving the capabilities of weak target detection.
文摘Purpose – Straightness measurement of rail weld joint is of essential importance to railway maintenance. Dueto the lack of efficient measurement equipment, there has been limited in-depth research on rail weld joint with a5-m wavelength range, leaving a significant knowledge gap in this field.Design/methodology/approach – In this study, the authors used the well-established inertial referencemethod (IR-method), and the state-of-the-art multi-point chord reference method (MCR-method). Two methodshave been applied in different types of rail straightness measurement trollies, respectively. These instrumentswere tested in a high-speed rail section within a certain region of China. The test results were ultimatelyvalidated through using traditional straightedge and feeler gauge methods as reference data to evaluate the railweld joint straightness within the 5-m wavelength range.Findings – The research reveals that IR-method and MCR-method produce reasonably similar measurementresults for wavelengths below 1 m. However, MCR-method outperforms IR-method in terms of accuracy forwavelengths exceeding 3 m. Furthermore, it was observed that IR-method, while operating at a slower speed,carries the risk of derailing and is incapable of detecting rail weld joints and low joints within the track.Originality/value – The research compare two methods’ measurement effects in a longer wavelength rangeand demonstrate the superiority of MCR-method.
文摘[Objectives]To study the reference value of thyroid function in healthy women of childbearing age during different pregnancies(early,middle and late pregnancy)in Jingzhou City.[Methods]362 healthy women of childbearing age during different pregnancies(early,middle and late pregnancy)were selected as the study group,and 360 non-pregnant women were selected as the control group.Serum thyroid hormone levels in the two groups were detected,and the reference value was expressed as the median(M)and 95%confidence interval(CI).On this basis,the chart of changing trend of thyroid hormone in the early,middle and late pregnancy were plotted.[Results]Compared with the control group,FT3,TT4,TT3,FT4and TSH in the early,middle and late pregnancy were significantly different in the study group(P<0.05).In the study group,there were significant differences in the early,middle and late pregnancy(P<0.05).[Conclusions]This trend chart has certain reference value in the screening,diagnosis and treatment of thyroid diseases in healthy women of childbearing age during different pregnancies(early,middle and late pregnancy)in Jingzhou City of Hubei Province.
基金supported by the National Natural Science Foundation of China(Grant No.61976101)the University Natural Science Research Project of Anhui Province(Grant No.2023AH040056)+4 种基金the Natural Science Research Project of Anhui Province(Graduate Research Project,Grant No.YJS20210463)the Funding Plan for Scientic Research Activities of Academic and Technical Leaders and Reserve Candidates in Anhui Province(Grant No.2021H264)the Top Talent Project of Disciplines(Majors)in Colleges and Universities in Anhui Province(Grant No.gxbjZD2022021)the University Synergy Innovation Program of Anhui Province,China(GXXT-2022-033)supported by the Innovation Fund for Postgraduates of Huaibei Normal University(Grant Nos.cx2022041,yx2021023,CX2023043).
文摘It is still a huge challenge for traditional Pareto-dominatedmany-objective optimization algorithms to solve manyobjective optimization problems because these algorithms hardly maintain the balance between convergence and diversity and can only find a group of solutions focused on a small area on the Pareto front,resulting in poor performance of those algorithms.For this reason,we propose a reference vector-assisted algorithmwith an adaptive niche dominance relation,for short MaOEA-AR.The new dominance relation forms a niche based on the angle between candidate solutions.By comparing these solutions,the solutionwith the best convergence is found to be the non-dominated solution to improve the selection pressure.In reproduction,a mutation strategy of k-bit crossover and hybrid mutation is used to generate high-quality offspring.On 23 test problems with up to 15-objective,we compared the proposed algorithm with five state-of-the-art algorithms.The experimental results verified that the proposed algorithm is competitive.
文摘The objectives of this work were to evaluate the surgical activities carried out in the general surgery department of the Reference Health Center of Commune I of Bamako, to describe the sociodemographic characteristics of the operated patients, to determine the main pathologies encountered and to evaluate qualitatively the result of the treatment. In order to improve performance, and the quality of care, and to identify common pathologies in the surgical department, we undertook a retrospective study on surgical activities from January 2009 to December 2010. At the end of this study, out of 474 men and 187 women (equal sex ratio 2.53);we were able to determine the frequency of surgical pathologies. Farmers, housewives and pupils/students were the most represented with 25.9% respectively;20% and 13.3%. The most frequently observed pathologies were wall hernia (44.8%), prostate adenoma (12%) and acute appendicitis (10.5%). The average length of hospitalization was 3.43 days. Infectious complications affected 25 patients (3.8% of cases) and a death rate of 0.45% (i.e. 3 patients). The average cost of care was 53,500 FCFA. Indeed, the reality of surgical practice in health centers was not the same because of the level of skills of practicing surgeons.