Theoretical and experimental analysis of a new refrigerant mixture BY-3 was conducted based on a single-stage vapor compression refrigeration system. The water-water heat pump system used BY-3 to produce hot water whe...Theoretical and experimental analysis of a new refrigerant mixture BY-3 was conducted based on a single-stage vapor compression refrigeration system. The water-water heat pump system used BY-3 to produce hot water when the low temperature was 20 ℃. The following results were obtained: the highest temperature at the condenser outlet reached about 85 ℃; when the difference between the water temperatures at the condenser outlet and the evaporator inlet was less than 40 ℃, the coefficient of performance (COP) was larger than 4; when the difference reached 55 ℃, the COP still kept 3; the discharge temperature of BY-3 was lower than 100 ℃, and the refrigerant vapor pressure kept lower than 1.8 MPa. When the water temperature at the condenser outlet reached over 85 ℃, nearly a 5 ℃ superheating temperature was maintained.展开更多
In this work,eight commonly used and recently developed cubic EOSs have beenextensively tested for the calculation of thermodynamic properties,including vapor pressure,vaporand liquid densities and heat of vaporizatio...In this work,eight commonly used and recently developed cubic EOSs have beenextensively tested for the calculation of thermodynamic properties,including vapor pressure,vaporand liquid densities and heat of vaporization for 26 pure CFCs and their alternatives.The modifiedDu-Guo EOS is recommended for the vapor-liquid equilibria calculations of mixtures for its goodaccuracy.A method for the development of the optimized mixture compositions of CFC alternativeshas been proposed by using minimization of deviations between the vapor pressures of CFC and thealternative mixtures of interest.As examples,two binary mixtures R22-R142b and R22-R152a,and aternary R22-R142b-R152a have been tested.The results show that the vapor pressure of R12 can bewell duplicated by a mixture refrigerant with the optimized composition.On the other hand,thedeviations between the heat of vaporization are somewhat apparent within 10 percent.Moreover,allthe mixtures discussed here are of the characteristics of being near azeotropic。展开更多
The present study aims to make a thermodynamic analysis of an ethylene cascade re-liquefaction system that consists of the following two subsystems: a liquefaction cycle using ethylene as the working fluid and a refri...The present study aims to make a thermodynamic analysis of an ethylene cascade re-liquefaction system that consists of the following two subsystems: a liquefaction cycle using ethylene as the working fluid and a refrigeration cycle operating with a hydrocarbon refrigerant. The hydrocarbon refrigerants considered are propane(R290), butane(R600), isobutane(R600a), and propylene(R1270). A computer program written in FORTRAN is developed to compute parameters for characteristic points of the cycles and the system's performance, which is determined and analyzed using numerical solutions for the refrigerant condensation temperature, temperature in tank, and temperature difference in the cascade condenser. Results show that R600 a gives the best performance, followed by(in order) R600, R290, and R1270. Furthermore, it is found that an increase in tank temperature improves system performance but that an increase in refrigerant condensation temperature causes deterioration. In addition, it is found that running the system at a low temperature difference in the cascade condenser is advantageous.展开更多
With the increasing environmental concern on global warming, hydrofluoro-olefin (HFOs), possessing low GWP, has attracted great attention of many researchers recently. In this study, non-azeotropic mixtures composed o...With the increasing environmental concern on global warming, hydrofluoro-olefin (HFOs), possessing low GWP, has attracted great attention of many researchers recently. In this study, non-azeotropic mixtures composed of HFOs (HFO-1234yf, HFO-1234ze(z), HFO-1234ze(e) and HFO-1234zf) are developed to substitute for HFC-134a and CFC-114 in air-conditioning and high-temperature heat pump systems, respectively. The cycle performances were evaluated by an improved theoretical cy-cle evaluation methodology. The results showed that all the mixtures proposed herein were favorable refrigerants with excel-lent thermodynamic cycle performances. M1A presented lower discharge temperature and pressure ratio and higher COPc than that of HFC-134a. The volumetric cooling capacity was similar to HFC-134a. It can be served as a good environmentally friendly alternative to replace HFC-134a. M3H delivered similar discharge temperature as CFC-114 did. And the COPh was 3% higher. It exhibits excellent cycle performance in high-temperature heat pump and is a promising refrigerant to substitute for CFC-114. And the gliding temperature differences enable them to exhibit better coefficient of performance by matching the sink/source temperature in practice. Because the toxicity, flammability and other properties are not investigated in detail, ex-tensive toxicity and flammability testing needs to be conducted before they are used in a particular application.展开更多
In this paper, a new ternary non-azeotropic mixture of HFC-161/125/143a (0.15/0.45/0.40 in mass fraction), as a promising mixed refrigerant to R404A, is presented. The ozone depletion potential (ODP) of the new re...In this paper, a new ternary non-azeotropic mixture of HFC-161/125/143a (0.15/0.45/0.40 in mass fraction), as a promising mixed refrigerant to R404A, is presented. The ozone depletion potential (ODP) of the new refrigerant is zero and its basic thermodynamic properties are similar to those of R404A, but its global warming potential (GWP) is much smaller than those of R507A and R404A. Meanwhile, theoretical calculations show that, under the working condition 1 (the average evaporation temperature: -23℃, the average condensing temperature: 43℃, the superheat temperature: 28℃, the subcooling temperature: 5 ℃), the volumetric refrigerating effect and specific refrigerating effect of the new mixture are 2.33% and 15.48% higher, re- spectively, than those of R404A. The coefficient of performance (COP) of the new mixture is 5.19% higher than that of R404A and the pressure ratio of the new mixture is 0.82% lower than that of R404A. Equally, under the working condition II (the average evaporation temperature: -40℃, the average condensing temperature: 35℃, the superheating temperature: 30 ~C, the subcooling temperature: 5℃), the volumetric refrigerating effect and specific refrigerating effect of the new mixture are 2.24% and 20.58% higher, respectively, than those of R404A. The COP of the new mixture is 4.60% higher than that of R404A and the pressure ratio of the new mixture is similar to that of R404A. The performances of the new mixture and R404A are compared in a vapor compressor refrigeration apparatus originally designed for R404A under several working conditions (condensing temperatures: 35-45℃, evaporation temperatures: -40--20℃). Experimental results show that the new mixture can obtain a higher COP, by 6.3% to 12.1%, and a lower pressure ratio, by 1.8% to 6.6%, compared to R404A; although the discharge temperature of the new mixture is slightly higher than that of R404A. The advantages of the new mixture will be further verified in the actual system.展开更多
New corresponding temperature and corresponding enthalpy of refrigerant mix- tures were defined. The relationship between saturated liquid corresponding en- thalpy and corresponding temperature of refrigerant mixtures...New corresponding temperature and corresponding enthalpy of refrigerant mix- tures were defined. The relationship between saturated liquid corresponding en- thalpy and corresponding temperature of refrigerant mixtures accorded with that of pure components. The characteristic parameters of saturated liquid enthalpy dif- ference of refrigerant mixtures were calculated by three methods according to the different application conditions. The generalized equation of saturated liquid en- thalpy of refrigerant mixtures was presented. The calculated values were compared with the values in literature for five ternary and binary refrigerant mixtures, namely R404A, R407A, R407B, R32/R134a, and R410A. The overall average absolute devia- tion was less than 1.0%.展开更多
The computation with the theory of modified Brayton Cycle indicates that higher cooling power and coefficient of performance for a pulse tube refrigerator can be achieved with He-H2 mixture as working gas than those w...The computation with the theory of modified Brayton Cycle indicates that higher cooling power and coefficient of performance for a pulse tube refrigerator can be achieved with He-H2 mixture as working gas than those with pure He in the temperature region of 30 K. In addition, it is found that Er3Ni, a regenerative material, is able to absorb H2 and produces Er3NiHx. The computation presents that the regenerative performance of Er3NiHx is better than that of Er3Ni due to its higher volume specific heat. Experimental results show that the pulse tube refrigeration performance in 30 K temperature region is enhanced greatly with He-H2 mixture and Er3NiHx packing.展开更多
Several media report highlight on that the pharmaceutical companies require ultra-low temperatures -80<span style="white-space:nowrap;">°</span>C to transport and store its COVID-19 vaccines...Several media report highlight on that the pharmaceutical companies require ultra-low temperatures -80<span style="white-space:nowrap;">°</span>C to transport and store its COVID-19 vaccines. This research presents the thermodynamic analysis on cascade refrigeration system (CRS) with several refrigerant pairs which are R32/R170, R123/R170, R134a/R170, R404A/R170, R407c/R170, R410/R170, and the hydrocarbon (HC) refrigerant pair Propane/Ethane, namely R290/R170. Besides, the results of R22/R170 pair, which is not recommended to be used due to phase out of R22 as per Montréal Protocol, are included as base case to compare the novel hydrocarbon pairs in CRS and the old trend of refrigerant pairs. Thermodynamic properties of all these pairs were investigated and compared under different intermediate temperature used in CRS heat exchanger, which thermally connected both the Low and High temperature cycles (LTC) and (HTC). By applying the first law of thermodynamics, the coefficients of performance (COPs) and the specific power consumptions (SPC) in kW/TR are presented and compared. In addition, by applying the second law of thermodynamics the exergetic efficiencies were estimated. The results reveal the promising opportunity of using the HC pair (R290/R170). The minimum SPC in kW/TR is recorded for the pair R123/R170. One the other hand, the highest exegetic efficiency values are observed to be 40%, 38%, and 35% for the pairs R123/R170, R290/R170, and R134/R170, respectively. This research concludes that the HC pair (R290/R170) is highly recommended for CRS applications either to transport the COVID-19 or store it in cold storage rooms in hospitals and clinics. All precautionary measures should be carefully applied in design and operation of HC pair (R290/R170) due to its flammability hazard.展开更多
In China, directly dropping high temperature refrigerant into conventional compressor is considered as a dominant technical route for development of moderately high temperature heat pump. Based on this route, selectio...In China, directly dropping high temperature refrigerant into conventional compressor is considered as a dominant technical route for development of moderately high temperature heat pump. Based on this route, selection criteria for high temperature refrigerant were presented with consideration of several influencing factors. Moreover, a set of research methods were built including theoretical calculations and experimental tests. Four high temperature refrigerants from HTR01 to HTR04 were compared and analyzed. In results, firstly, HTR03 and HTR04 belonging to non-ozone depleting refrigerants could bring outstanding environmental benefits; secondly, the condenser outlet water efficiently generated by heat pump using high temperature refrigerants could cover 60°C–90°C;; finally, the feasibility of the technical route and the research methods were proved.展开更多
The surface tensions of 21 pure refrigerants have been predicted by a new improved equation based on the principle of corresponding states with double referenced fluids.The average absolute deviation between the calcu...The surface tensions of 21 pure refrigerants have been predicted by a new improved equation based on the principle of corresponding states with double referenced fluids.The average absolute deviation between the calculated surface tensions from the equation and the experimental result is-0.015 mN/m.The surface tensions of 9 binary mixtures were calculated in consideration of certain mixing rules.And the average absolute deviation between the calculated surface tensions from the equation and the experimental result is-0.251 mN/m.The new improved prediction equation can be used for calculating the surface tension of environmental friendly refrigerants.展开更多
为了适应节能与环境保护的需求,研究了一种适用于自复叠制冷系统的新型绿色混合制冷工质(R290/R744)的汽液相平衡特性。根据相平衡条件采用PT状态方程结合Van der Waals混合规则推导出该混合制冷工质的相平衡计算式,通过软件编程计算了...为了适应节能与环境保护的需求,研究了一种适用于自复叠制冷系统的新型绿色混合制冷工质(R290/R744)的汽液相平衡特性。根据相平衡条件采用PT状态方程结合Van der Waals混合规则推导出该混合制冷工质的相平衡计算式,通过软件编程计算了两种有工程实用意义的相平衡问题,一种是已知混合物压力和液相摩尔分数,计算泡点温度和气相摩尔分数;另一种是已知混合物压力和气相摩尔分数,计算露点温度和液相摩尔分数,并根据计算数据绘制了汽液平衡曲线。数据显示最大相对误差为4.840%,最小相对误差为0.005%。计算结果表明,采用给出的R290/R744混合制冷剂相平衡计算式具有较高的计算精度,从而为采用该混合制冷剂的自复叠制冷循环研究奠定基础。展开更多
基金Supported by Major State Basic Research Development Program of China ("973" Program, No. 2009CB219907)the Program for Changjiang Scholars and Innovative Research Team in University (No. IRT0936)
文摘Theoretical and experimental analysis of a new refrigerant mixture BY-3 was conducted based on a single-stage vapor compression refrigeration system. The water-water heat pump system used BY-3 to produce hot water when the low temperature was 20 ℃. The following results were obtained: the highest temperature at the condenser outlet reached about 85 ℃; when the difference between the water temperatures at the condenser outlet and the evaporator inlet was less than 40 ℃, the coefficient of performance (COP) was larger than 4; when the difference reached 55 ℃, the COP still kept 3; the discharge temperature of BY-3 was lower than 100 ℃, and the refrigerant vapor pressure kept lower than 1.8 MPa. When the water temperature at the condenser outlet reached over 85 ℃, nearly a 5 ℃ superheating temperature was maintained.
文摘In this work,eight commonly used and recently developed cubic EOSs have beenextensively tested for the calculation of thermodynamic properties,including vapor pressure,vaporand liquid densities and heat of vaporization for 26 pure CFCs and their alternatives.The modifiedDu-Guo EOS is recommended for the vapor-liquid equilibria calculations of mixtures for its goodaccuracy.A method for the development of the optimized mixture compositions of CFC alternativeshas been proposed by using minimization of deviations between the vapor pressures of CFC and thealternative mixtures of interest.As examples,two binary mixtures R22-R142b and R22-R152a,and aternary R22-R142b-R152a have been tested.The results show that the vapor pressure of R12 can bewell duplicated by a mixture refrigerant with the optimized composition.On the other hand,thedeviations between the heat of vaporization are somewhat apparent within 10 percent.Moreover,allthe mixtures discussed here are of the characteristics of being near azeotropic。
文摘The present study aims to make a thermodynamic analysis of an ethylene cascade re-liquefaction system that consists of the following two subsystems: a liquefaction cycle using ethylene as the working fluid and a refrigeration cycle operating with a hydrocarbon refrigerant. The hydrocarbon refrigerants considered are propane(R290), butane(R600), isobutane(R600a), and propylene(R1270). A computer program written in FORTRAN is developed to compute parameters for characteristic points of the cycles and the system's performance, which is determined and analyzed using numerical solutions for the refrigerant condensation temperature, temperature in tank, and temperature difference in the cascade condenser. Results show that R600 a gives the best performance, followed by(in order) R600, R290, and R1270. Furthermore, it is found that an increase in tank temperature improves system performance but that an increase in refrigerant condensation temperature causes deterioration. In addition, it is found that running the system at a low temperature difference in the cascade condenser is advantageous.
基金supported by the National Natural Science Foundation of China (Grant No. 50976079)Science and Technology Support Key Project of Tianjin (Grant No. 10ZCKFGX01700)
文摘With the increasing environmental concern on global warming, hydrofluoro-olefin (HFOs), possessing low GWP, has attracted great attention of many researchers recently. In this study, non-azeotropic mixtures composed of HFOs (HFO-1234yf, HFO-1234ze(z), HFO-1234ze(e) and HFO-1234zf) are developed to substitute for HFC-134a and CFC-114 in air-conditioning and high-temperature heat pump systems, respectively. The cycle performances were evaluated by an improved theoretical cy-cle evaluation methodology. The results showed that all the mixtures proposed herein were favorable refrigerants with excel-lent thermodynamic cycle performances. M1A presented lower discharge temperature and pressure ratio and higher COPc than that of HFC-134a. The volumetric cooling capacity was similar to HFC-134a. It can be served as a good environmentally friendly alternative to replace HFC-134a. M3H delivered similar discharge temperature as CFC-114 did. And the COPh was 3% higher. It exhibits excellent cycle performance in high-temperature heat pump and is a promising refrigerant to substitute for CFC-114. And the gliding temperature differences enable them to exhibit better coefficient of performance by matching the sink/source temperature in practice. Because the toxicity, flammability and other properties are not investigated in detail, ex-tensive toxicity and flammability testing needs to be conducted before they are used in a particular application.
基金supported by the Nation Natural Science Foundation of China (No. 50806063)the Program for Key Innovative Research Team of Zhejiang Province (No. 2009R50036), China
文摘In this paper, a new ternary non-azeotropic mixture of HFC-161/125/143a (0.15/0.45/0.40 in mass fraction), as a promising mixed refrigerant to R404A, is presented. The ozone depletion potential (ODP) of the new refrigerant is zero and its basic thermodynamic properties are similar to those of R404A, but its global warming potential (GWP) is much smaller than those of R507A and R404A. Meanwhile, theoretical calculations show that, under the working condition 1 (the average evaporation temperature: -23℃, the average condensing temperature: 43℃, the superheat temperature: 28℃, the subcooling temperature: 5 ℃), the volumetric refrigerating effect and specific refrigerating effect of the new mixture are 2.33% and 15.48% higher, re- spectively, than those of R404A. The coefficient of performance (COP) of the new mixture is 5.19% higher than that of R404A and the pressure ratio of the new mixture is 0.82% lower than that of R404A. Equally, under the working condition II (the average evaporation temperature: -40℃, the average condensing temperature: 35℃, the superheating temperature: 30 ~C, the subcooling temperature: 5℃), the volumetric refrigerating effect and specific refrigerating effect of the new mixture are 2.24% and 20.58% higher, respectively, than those of R404A. The COP of the new mixture is 4.60% higher than that of R404A and the pressure ratio of the new mixture is similar to that of R404A. The performances of the new mixture and R404A are compared in a vapor compressor refrigeration apparatus originally designed for R404A under several working conditions (condensing temperatures: 35-45℃, evaporation temperatures: -40--20℃). Experimental results show that the new mixture can obtain a higher COP, by 6.3% to 12.1%, and a lower pressure ratio, by 1.8% to 6.6%, compared to R404A; although the discharge temperature of the new mixture is slightly higher than that of R404A. The advantages of the new mixture will be further verified in the actual system.
基金Supported by the National Natural Science Foundation of China (Grant No. 50336020)
文摘New corresponding temperature and corresponding enthalpy of refrigerant mix- tures were defined. The relationship between saturated liquid corresponding en- thalpy and corresponding temperature of refrigerant mixtures accorded with that of pure components. The characteristic parameters of saturated liquid enthalpy dif- ference of refrigerant mixtures were calculated by three methods according to the different application conditions. The generalized equation of saturated liquid en- thalpy of refrigerant mixtures was presented. The calculated values were compared with the values in literature for five ternary and binary refrigerant mixtures, namely R404A, R407A, R407B, R32/R134a, and R410A. The overall average absolute devia- tion was less than 1.0%.
文摘The computation with the theory of modified Brayton Cycle indicates that higher cooling power and coefficient of performance for a pulse tube refrigerator can be achieved with He-H2 mixture as working gas than those with pure He in the temperature region of 30 K. In addition, it is found that Er3Ni, a regenerative material, is able to absorb H2 and produces Er3NiHx. The computation presents that the regenerative performance of Er3NiHx is better than that of Er3Ni due to its higher volume specific heat. Experimental results show that the pulse tube refrigeration performance in 30 K temperature region is enhanced greatly with He-H2 mixture and Er3NiHx packing.
文摘Several media report highlight on that the pharmaceutical companies require ultra-low temperatures -80<span style="white-space:nowrap;">°</span>C to transport and store its COVID-19 vaccines. This research presents the thermodynamic analysis on cascade refrigeration system (CRS) with several refrigerant pairs which are R32/R170, R123/R170, R134a/R170, R404A/R170, R407c/R170, R410/R170, and the hydrocarbon (HC) refrigerant pair Propane/Ethane, namely R290/R170. Besides, the results of R22/R170 pair, which is not recommended to be used due to phase out of R22 as per Montréal Protocol, are included as base case to compare the novel hydrocarbon pairs in CRS and the old trend of refrigerant pairs. Thermodynamic properties of all these pairs were investigated and compared under different intermediate temperature used in CRS heat exchanger, which thermally connected both the Low and High temperature cycles (LTC) and (HTC). By applying the first law of thermodynamics, the coefficients of performance (COPs) and the specific power consumptions (SPC) in kW/TR are presented and compared. In addition, by applying the second law of thermodynamics the exergetic efficiencies were estimated. The results reveal the promising opportunity of using the HC pair (R290/R170). The minimum SPC in kW/TR is recorded for the pair R123/R170. One the other hand, the highest exegetic efficiency values are observed to be 40%, 38%, and 35% for the pairs R123/R170, R290/R170, and R134/R170, respectively. This research concludes that the HC pair (R290/R170) is highly recommended for CRS applications either to transport the COVID-19 or store it in cold storage rooms in hospitals and clinics. All precautionary measures should be carefully applied in design and operation of HC pair (R290/R170) due to its flammability hazard.
基金Supported by Program for New Century Excellent Talents in University (Grand No. NCET-04-0078)
文摘In China, directly dropping high temperature refrigerant into conventional compressor is considered as a dominant technical route for development of moderately high temperature heat pump. Based on this route, selection criteria for high temperature refrigerant were presented with consideration of several influencing factors. Moreover, a set of research methods were built including theoretical calculations and experimental tests. Four high temperature refrigerants from HTR01 to HTR04 were compared and analyzed. In results, firstly, HTR03 and HTR04 belonging to non-ozone depleting refrigerants could bring outstanding environmental benefits; secondly, the condenser outlet water efficiently generated by heat pump using high temperature refrigerants could cover 60°C–90°C;; finally, the feasibility of the technical route and the research methods were proved.
基金Supported by the Specialized Research Fund for the National Natural Science Foundation of China(No.51276142) and the Fundamental Research Funds for the Central Universities, China(No.08143036).
文摘The surface tensions of 21 pure refrigerants have been predicted by a new improved equation based on the principle of corresponding states with double referenced fluids.The average absolute deviation between the calculated surface tensions from the equation and the experimental result is-0.015 mN/m.The surface tensions of 9 binary mixtures were calculated in consideration of certain mixing rules.And the average absolute deviation between the calculated surface tensions from the equation and the experimental result is-0.251 mN/m.The new improved prediction equation can be used for calculating the surface tension of environmental friendly refrigerants.
文摘为了适应节能与环境保护的需求,研究了一种适用于自复叠制冷系统的新型绿色混合制冷工质(R290/R744)的汽液相平衡特性。根据相平衡条件采用PT状态方程结合Van der Waals混合规则推导出该混合制冷工质的相平衡计算式,通过软件编程计算了两种有工程实用意义的相平衡问题,一种是已知混合物压力和液相摩尔分数,计算泡点温度和气相摩尔分数;另一种是已知混合物压力和气相摩尔分数,计算露点温度和液相摩尔分数,并根据计算数据绘制了汽液平衡曲线。数据显示最大相对误差为4.840%,最小相对误差为0.005%。计算结果表明,采用给出的R290/R744混合制冷剂相平衡计算式具有较高的计算精度,从而为采用该混合制冷剂的自复叠制冷循环研究奠定基础。