期刊文献+
共找到5,550篇文章
< 1 2 250 >
每页显示 20 50 100
Evaluation of frictional pressure drop correlations for air-water and air-oil two-phase flow in pipeline-riser system
1
作者 Nai-Liang Li Bin Chen 《Petroleum Science》 SCIE EI CAS CSCD 2024年第2期1305-1319,共15页
Accurate prediction of the frictional pressure drop is important for the design and operation of subsea oil and gas transporting system considering the length of the pipeline. The applicability of the correlations to ... Accurate prediction of the frictional pressure drop is important for the design and operation of subsea oil and gas transporting system considering the length of the pipeline. The applicability of the correlations to pipeline-riser flow needs evaluation since the flow condition in pipeline-riser is quite different from the original data where they were derived from. In the present study, a comprehensive evaluation of 24prevailing correlation in predicting frictional pressure drop is carried out based on experimentally measured data of air-water and air-oil two-phase flows in pipeline-riser. Experiments are performed in a system having different configuration of pipeline-riser with the inclination of the downcomer varied from-2°to-5°to investigated the effect of the elbow on the frictional pressure drop in the riser. The inlet gas velocity ranges from 0.03 to 6.2 m/s, and liquid velocity varies from 0.02 to 1.3 m/s. A total of885 experimental data points including 782 on air-water flows and 103 on air-oil flows are obtained and used to access the prediction ability of the correlations. Comparison of the predicted results with the measured data indicate that a majority of the investigated correlations under-predict the pressure drop on severe slugging. The result of this study highlights the requirement of new method considering the effect of pipe layout on the frictional pressure drop. 展开更多
关键词 Frictional pressure drop Pipeline-riser Gas-liquid two-phase flow Severe slugging CORRELATION
下载PDF
Pump-stopping pressure drop model considering transient leak-off of fracture network
2
作者 WANG Fei XU Jiaxin +1 位作者 ZHOU Tong ZHANG Shicheng 《Petroleum Exploration and Development》 SCIE 2023年第2期473-483,共11页
By introducing the coupling flow expressions of main fracture-matrix, secondary fracture-matrix and main fracture-secondary fracture into the traditional main fracture material balance equation, the “main fracture-se... By introducing the coupling flow expressions of main fracture-matrix, secondary fracture-matrix and main fracture-secondary fracture into the traditional main fracture material balance equation, the “main fracture-secondary fracture-matrix” leak-off coupling flow model is established. The pressure-dependent fracture width equation and the wellbore injection volume equation are coupled to solve the pressure-rate continuity problem. The simulation and calculation of the bottomhole pressure drop and fracture network closure after the pump stopping in slickwater volumetric fracturing treatment are realized. The research results show that the log-log curve of pump-stopping bottomhole pressure drop derivative presents five characteristic slope segments, reflecting four dominant stages, i.e. inter-fracture crossflow, fracture network leak-off, fracture network closure and residual leak-off, after pump shutdown. At the initial time of pump shutdown for volumetric fracturing treatment of horizontal well, the crossflow between main and secondary fractures is obvious, and then the leak-off becomes dominant. The leak-off of main and secondary fractures shows a non-uniform decreasing trend. Specifically, the leak-off of main fractures is slow, while that of secondary fractures is fast;the fracture network as a whole presents the leak-off law of fast first, then slow, until close to zero. The influence of fracture network conductivity on the shape of pressure decline curve is relatively weaker than that of fracture network size. The fracture network conductivity is positively correlated with leak-off volume and fracture closure. The secondary fracture size is positively correlated with leakoff volume and closure of the secondary fracture, but negatively correlated with closure of the main fracture. Field data validation proves that the proposed model and simulation results can effectively reflect the closure characteristics of the fracture network, and the interpretation results are reliable and can reflect the non-uniform stimulation performance of each fracturing stage of an actual horizontal well. 展开更多
关键词 volume fracturing stop-pumping pressure drop fracture network characteristic curve transient leak-off frac-ture closure stimulation performance
下载PDF
Multi-criteria comparative analysis of the pressure drop on coal gangue fly-ash slurry at different parts along an L-shaped pipeline
3
作者 Defeng Wang Dengwu Jiao +2 位作者 Zhanbo Cheng Qingwen Shi Helmut Mischo 《International Journal of Coal Science & Technology》 EI CAS CSCD 2023年第2期129-145,共17页
Disposing of coal gangue and fly-ash on the surface is a risky method with tremendous potential catastrophic consequences for the environment.Backfill mining is a promising practice for turning those hazardous wastes ... Disposing of coal gangue and fly-ash on the surface is a risky method with tremendous potential catastrophic consequences for the environment.Backfill mining is a promising practice for turning those hazardous wastes into functional backfill materi-als.Unfortunately,how to efficiently deliver the slurry to the desired places remains under-researched.To address this issue,the computational fluid dynamics software Fluent was used in the current study in addition to a laboratory rheological test to simulate the impact of various parameters on the evolution of pressure at a particular section of the pipeline.Furthermore,the response surface method was employed to investigate how the various components and their corresponding influencing weights interact to affect the pressure drop.This study demonstrates that the pressure drop of the slurry is highly influenced by slurry concentration,speed,and pipe diameter.While conveying speed is the main component in the bend section,pipe diameter takes over in the horizontal and vertical pipe sections. 展开更多
关键词 Coal gangue slurry pressure drop Numerical simulation Response surface analysis
下载PDF
In Tube Condensation:Changing the Pressure Drop into a Temperature Difference for a Wire-on-Tube Heat Exchanger
4
作者 Louay Abd Al-Azez Mahdi Mohammed A.Fayad Miqdam T.Chaichan 《Fluid Dynamics & Materials Processing》 EI 2023年第9期2201-2214,共14页
A theoretical study based on the Penalty factor(PF)method by Cavallini et al.is conducted to show that the pressure drop occurring in a wire-on-tube heat exchanger can be converted into a temperature difference for tw... A theoretical study based on the Penalty factor(PF)method by Cavallini et al.is conducted to show that the pressure drop occurring in a wire-on-tube heat exchanger can be converted into a temperature difference for two types of refrigerants R-134a and R-600a typically used for charging refrigerators and freezers.The following conditions are considered:stratified or stratified-wavyflow condensation occurring inside the smooth tube of a wire-on-tube condenser with diameter 3.25,4.83,and 6.299 mm,condensation temperatures 35℃,45℃,and 54.4℃ and cover refrigerant massflow rate spanning the interval from 1 to 7 kg/hr.The results show that the PF variation is not linear with vapor quality and attains a maximum when the vapor quality is 0.2 and 0.18 for the R-134a and R-600a refrigerants,respectively.The PF increases with the refrigerant massflow rate if the inner diameter and saturation temperature constant,and it decreases on increasing the inner diameter to 6.299 mm for constant refrigerant massflow rate and saturation temperature.The PF for R-600a is higher than that for R-134a due to the lower saturation pressure in thefirst case.Furthermore,a stratifiedflow produces higher PF in comparison to the annularflow due to the effect of the surface tension. 展开更多
关键词 CONDENSATION penalty factor pressure drop temperature difference TWO-PHASE wire condenser
下载PDF
Influence of Wellbore Trajectory on Pressure Drop and Fluid Discharge
5
作者 Ruidong Wu Guowei Wang +2 位作者 Zhixing Yang Ruiquan Liao Yang Cheng 《Fluid Dynamics & Materials Processing》 EI 2023年第8期2053-2066,共14页
An experimental analysis has been conducted to study the process of fluid accumulation for different borehole trajectories.More specifically,five heel angles have been experimentally realized to simulate the borehole ... An experimental analysis has been conducted to study the process of fluid accumulation for different borehole trajectories.More specifically,five heel angles have been experimentally realized to simulate the borehole trajectory of the sloping section of the formation.The fluid-carrying capacity,pressure drop and fluid discharge volatility have been investigated for these conditions and,accordingly,the relationship between heel angle and wellbore pressure drop fluid-carrying capacity has been determined.The results show that while the reasonable roll angle can increase the pressure loss in the wellbore,it is beneficial to drainage.In terms of pressure loss and liquid-carrying capacity,when the heeling angle is 50°,the latter is increased while the former becomes very high,which indicates that when drilling and completing wells on site,a 50°roll angle should be avoided.It is found that the main reason for the increase of the total pressure drop in the wellbore is the increase of the local pressure loss in the inclined section.From the perspective of drainage stability,when there is heeling in the inclined section of the horizontal well,the fluctuation of the wellbore drainage tends to be enhanced.Through the comparison of the Beggs-Brill(B-B)and Mukherjee-Brill liquid holdup methods,it is found that B-B method better predicts liquid holdup.A new method for calculating the pressure drop in the inclined section in the presence of lateral inclination is obtained by taking into account the pressure drop in the curved section.Through comparison with experimental data,it is found that the error is within 20%,and the prediction accuracy is high. 展开更多
关键词 Horizontal well slant section heel angle pressure drop drainage quantity
下载PDF
Prediction of Pressure Drop of Slurry Flow in Pipeline by Hybrid Support Vector Regression and Genetic Algorithm Model 被引量:25
6
作者 S.K. Lahiri K.C. Ghanta 《Chinese Journal of Chemical Engineering》 SCIE EI CAS CSCD 2008年第6期841-848,共8页
This paper describes a robust support vector regression (SVR) methodology, which can offer superior performance for important process engineering problems. The method incorporates hybrid support vector regression an... This paper describes a robust support vector regression (SVR) methodology, which can offer superior performance for important process engineering problems. The method incorporates hybrid support vector regression and genetic algorithm technique (SVR-GA) for efficient tuning of SVR meta-parameters. The algorithm has been applied for prediction of pressure drop of solid liquid slurry flow. A comparison with selected correlations in the lit- erature showed that the developed SVR correlation noticeably improved the prediction of pressure drop over a wide range of operating conditions, physical properties, and pipe diameters. 展开更多
关键词 support vector regression genetic algorithm slurry pressure drop
下载PDF
A Calculation of Steady Pressure Drop and an Analysis of HT-7U CICC 被引量:6
7
作者 武玉 《Plasma Science and Technology》 SCIE EI CAS CSCD 2002年第4期1395-1398,共4页
Under the condition of steady state, the pressure drop of coolant is mainly caused by friction along the cable. In the CICC (cable-in-conduit-conductor), helium flow within the conductor consists of two parallel inter... Under the condition of steady state, the pressure drop of coolant is mainly caused by friction along the cable. In the CICC (cable-in-conduit-conductor), helium flow within the conductor consists of two parallel interconnected tubes. The velocity distribution has some differece between the central channel and conductor space. The region of Reynolds number is from 103 to 106. This paper describes the calculation of pressure drop of HT-7U CICC at various mass flows. It is assumed that the coolant flows in two parallel, rough tubes during the calculation. 展开更多
关键词 HT-7U tokamak cable-in-conduit-conductor steady pressure drop calculation and analysis
下载PDF
Experimental investigation on boiling heat transfer and pressure drop of R245fa in a horizontal micro-fin tube 被引量:3
8
作者 WANG Zhi-qi HE Ni +1 位作者 XIA Xiao-xia LIU Li-wen 《Journal of Central South University》 SCIE EI CAS CSCD 2019年第11期3200-3212,共13页
An experimental investigation on the boiling heat transfer and frictional pressure drop of R245fa in a 7 mm horizontal micro-fin tube was performed.The results show that in terms of flow boiling heat transfer characte... An experimental investigation on the boiling heat transfer and frictional pressure drop of R245fa in a 7 mm horizontal micro-fin tube was performed.The results show that in terms of flow boiling heat transfer characteristics,boiling heat transfer coefficient(HTC)increases with mass velocity of R245fa,while it decreases with the increment of saturation temperature and heat flux.With the increase of vapor quality,HTC has a maximum and the corresponding vapor quality is about 0.4,which varies with the operating conditions.When vapor quality is larger than the transition point,HTC can be promoted more remarkably at higher mass velocity or lower saturation temperature.Among the four selected correlations,KANDLIKAR correlation matches with 91.6%of experimental data within the deviation range of±25%,and the absolute mean deviation is 11.2%.Also,in terms of frictional pressure drop characteristics of flow boiling,the results of this study show that frictional pressure drop increases with mass velocity and heat flux of R245fa,while it decreases with the increment of saturation temperature.MULLER-STEINHAGEN-HECK correlation shows the best prediction accuracy for frictional pressure drop among the four widely used correlations.It covers 84.1%of experimental data within the deviation range of±20%,and the absolute mean deviation is 10.1%. 展开更多
关键词 boiling heat transfer frictional pressure drop prediction correlations micro-fin tube R245fa fluid
下载PDF
Numerical study of pressure drop for a new fibrous media model
9
作者 周斌 Paolo Tronville +1 位作者 Richard Rivers 张小松 《Journal of Southeast University(English Edition)》 EI CAS 2010年第2期311-315,共5页
An open-source computational fluid dynamics(CFD)code named OpenFOAM is used to validate the flow field characteristics(flow patterns and pressure drop)around a single cylinder.Results show that OpenFOAM is suitabl... An open-source computational fluid dynamics(CFD)code named OpenFOAM is used to validate the flow field characteristics(flow patterns and pressure drop)around a single cylinder.Results show that OpenFOAM is suitable for simulating the low Reynolds number flow and Shaw's analytical expression is one of the solutions to Stokes' paradox.Experiments are performed on fibrous media and OpenFOAM simulation is carried out using the Tronville-Rivers two-dimensional random fiber model in terms of the characteristics of pressure drop.It is shown that the Kuwabara model predicts the pressure drop of fibrous filter media more accurately than the Happel model,and the experimental pressure drop is between simulated pressure drops with both non-slip and full-slip boundaries on fiber surfaces. 展开更多
关键词 fibrous media diameter distribution pressure drop computational fluid dynamics simulation
下载PDF
Measurement and Correlation of Pressure Drop for Gas-Liquid Two-phase Flow in Rectangular Microchannels 被引量:16
10
作者 MA Youguang JI Xiyan WANG Dongji FU Taotao ZHU Chunying 《Chinese Journal of Chemical Engineering》 SCIE EI CAS CSCD 2010年第6期940-947,共8页
The pressure drop of gas-liquid two-phase flow in microchannel is of fundamental importance in heat and mass transfer processes. In this work,the pressure drop of gas-liquid two-phase flow in horizontal rectangular cr... The pressure drop of gas-liquid two-phase flow in microchannel is of fundamental importance in heat and mass transfer processes. In this work,the pressure drop of gas-liquid two-phase flow in horizontal rectangular cross-section microchannels was measured by a pressure differential transducer system. Water,ethanol and n-propanol were used as liquid phase to study the effects of capillary number on pressure drop;air was used as the gas phase. Four microchannels with various dimensions of 100 μm× 200 μm,100 μm× 400 μm,100 μm× 800 μm and 100 μm× 2000 μm(depth × width) were used for determining the influence of configuration on the pressure drop. Experimental results showed that in micro-scale,the capillary number also affected the pressure drop remarkably,and in spite of only one-fold difference in aspect ratio,the variation of pressure drop reached up to near three times under the same experimental conditions. Taking the effects of aspect ratio and surface tension into account,a modi-fied correlation for Chisholm parameter C in the Chisholm model was proposed for predicting the frictional multi-plier,and the predicted values by the proposed correlation showed a satisfactory agreement with experimental data. 展开更多
关键词 pressure drop rectangular cross-section microchannel surface tension configuration influence Chis-holm parameter C
下载PDF
Effect of Radial Resistance Gap on the Pressure Drop of a Compact Annular-Radial-Orifice Flow Magnetorheological Valve 被引量:4
11
作者 Guoliang Hu Jiawei Zhang +1 位作者 Mingke Liao Ruqi Ding 《Journal of Beijing Institute of Technology》 EI CAS 2018年第4期535-546,共12页
A compact annular-radial-orifice flow magnetorheological(MR)valve was developed to investigate the effects of radial resistance gap on pressure drop.The fluid flow paths of this proposed MR valve consist of a single a... A compact annular-radial-orifice flow magnetorheological(MR)valve was developed to investigate the effects of radial resistance gap on pressure drop.The fluid flow paths of this proposed MR valve consist of a single annular flow channel,a single radial flow channel and an orifice flow channel through structure design.The finite element modelling and simulation analysis of the MR valve was carried out using ANSYS/Emag software to investigate the changes of the magnetic flux density and yield stress along the fluid flow paths under the four different radial resistance gaps.Moreover,the experimental tests were also conducted to evaluate the pressure drop,showing that the proposed MR valve has significantly improved its pressure drop at 0.5 mm width of the radial resistance gap when the annular resistance gap is fixed at 1 mm. 展开更多
关键词 magnetorheological(MR)valve annular-radial-orifice flow pressure drop radial resistance gap finite element analysis
下载PDF
Flow pattern and pressure drop of gas-liquid two-phase swirl flow in a horizontal pipe 被引量:5
12
作者 RAO Yong-chao DING Bo-yang +2 位作者 WANG Shu-li WANG Zi-wen ZHOU Shi-dong 《Journal of Central South University》 SCIE EI CAS CSCD 2019年第9期2528-2542,共15页
The gas-liquid two-phase swirl flow can increase the gas-liquid two-phase contact area and enhance the heat and mass transfer efficiency between gas and liquid.The swirl flow has important practical application value ... The gas-liquid two-phase swirl flow can increase the gas-liquid two-phase contact area and enhance the heat and mass transfer efficiency between gas and liquid.The swirl flow has important practical application value for promoting gas hydrate formation and ensuring the flow safe of natural gas hydrate slurry.The experimental section was made of plexiglass pipe and the experimental medium was air and water.The flow pattern of the gas-liquid two-phase swirl flow in the horizontal pipe was divided,according to a high-definition camera and the overall characteristics of the gas-liquid interface.The flow pattern map of the gas-liquid two-phase swirl flow in a horizontal pipe was studied.The influence of the flow velocity and vane parameters on pressure drop was investigated.Two types of gas-liquid two-phase swirl flow pressure drop models was established.The homogeneous-phase and split-phase pressure drop models have good prediction on swirl bubble flow,swirl dispersed flow,swirl annular flow and swirl stratified flow,and the predictive error band is not more than 20%. 展开更多
关键词 swirl flow two-phase flow flow pattern swirl number pressure drop
下载PDF
Research on Pressure Drop Performance of the Packing-Flotation Column 被引量:9
13
作者 LIU Jiong-tian ZHANG Min +1 位作者 LI Yan-feng LU Yang 《Journal of China University of Mining and Technology》 EI 2006年第4期389-392,共4页
A packing-flotation column was proposed to optimize the flotation environment A research system was es- tablished using a 100 mm diameter cyclonic micro-bubble flotation column to study fluid properties. Dry-plate and... A packing-flotation column was proposed to optimize the flotation environment A research system was es- tablished using a 100 mm diameter cyclonic micro-bubble flotation column to study fluid properties. Dry-plate and wet- plate pressure drops were studied and the corresponding pressure drop equations developed. The results show that the dry-plate pressure drop of the packing cyclonic micro-bubble flotation column is 10–15 times less than that of the chemical tower, which is principally shown in its relatively small resistance coefficient, ξ ≈0.0207. The wet-plate pressure drop is 2–3 times higher than that of the chemical tower, which is largely caused by the separation materials and characteristics of the equipment. With flotation, the greater the pressure drop, the better the flotation environment. 展开更多
关键词 sieve plate PACKING flotation column pressure drop
下载PDF
Delineation of epicardial stenosis in patients with microvascular disease using pressure drop coefficient:A pilot outcome study 被引量:2
14
作者 Ullhas Udaya Hebbar Mohamed A Effat +2 位作者 Srikara V Peelukhana Imran Arif Rupak K Banerjee 《World Journal of Cardiology》 CAS 2017年第12期813-821,共9页
AIM To investigate the patient-outcomes of newly developed pressure drop coefficient(CDP) in diagnosing epicardial stenosis(ES) in the presence of concomitant microvascular disease(MVD).METHODS Patients from our clini... AIM To investigate the patient-outcomes of newly developed pressure drop coefficient(CDP) in diagnosing epicardial stenosis(ES) in the presence of concomitant microvascular disease(MVD).METHODS Patients from our clinical trial were divided into two subgroups with:(1) cut-off of coronary flow reserve(CFR) < 2.0;and(2) diabetes.First,correlations were performed for both subgroups between CDP and hyperemic microvascular resistance(HMR),a diagnostic parameter for assessing the severity of MVD.Linear regression analysis was used for these correlations.Further,in each of the subgroups,comparisons were made between fractional flow reserve(FFR) < 0.75 and CDP > 27.9 groups for assessing major adverse cardiac events(MACE:Primary outcome).Comparisons were also made between the survival curves for FFR < 0.75 and CDP > 27.9 groups.Two tailed chi-squared and Fischer's exact tests were performed for comparison of the primary outcomes,and the log-rank test was used to compare the Kaplan-Meier survival curves.P < 0.05 for all tests was considered statistically significant.RESULTS Significant linear correlations were observed between CDP and HMR for both CFR < 2.0(r = 0.58,P < 0.001) and diabetic(r = 0.61,P < 0.001) patients.In the CFR < 2.0 subgroup,the %MACE(primary outcomes) for CDP > 27.9 group(7.7%,2/26) was lower than FFR < 0.75 group(3/14,21.4%);P = 0.21.Similarly,in the diabetic subgroup,the %MACE for CDP > 27.9 group(12.5%,2/16) was lower than FFR < 0.75 group(18.2%,2/11);P = 0.69.Survival analysis for CFR < 2.0 subgroup indicated better event-free survival for CDP > 27.9 group(n = 26) when compared with FFR < 0.75 group(n = 14);P = 0.10.Similarly,for the diabetic subgroup,CDP > 27.9 group(n = 16) showed higher survival times compared to FFR group(n = 11);P = 0.58.CONCLUSION CDP correlated significantly with HMR and resulted in better %MACE as well as survival rates in comparison to FFR.These positive trends demonstrate that CDP could be a potential diagnostic endpoint for delineating MVD with or without ES. 展开更多
关键词 Fractional flow reserve pressure drop coefficient MICROVASCULAR disease Intermediate coronary STENOSIS INTERVENTIONAL CARDIOLOGY
下载PDF
Analysis of MHD Pressure Drop in Liquid LiPb Flow in Chinese ITER DFLL-TBM with Insulating Coating 被引量:2
15
作者 陈红丽 周涛 王红艳 《Plasma Science and Technology》 SCIE EI CAS CSCD 2008年第4期494-498,共5页
Magnetohydrodynamic (MHD) pressure drop in the Chinese Dual Functional Liquid Lithium-lead Test Blanket Module (DFLL-TBM) proposed for ITER is discussed in this paper. Electrical insulation between the coolant cha... Magnetohydrodynamic (MHD) pressure drop in the Chinese Dual Functional Liquid Lithium-lead Test Blanket Module (DFLL-TBM) proposed for ITER is discussed in this paper. Electrical insulation between the coolant channel surfaces and the liquid metal is required to reduce the MHD pressure drop to a manageable level. Insulation can be provided by a thin insulating coating, such as Al2O3, which can also serve as a tritium barrier layer, at the channel surfaces in contact with LiPb. The coating's effectiveness for reducing the MHD pressure drop is analysed through three-dimensional numerical simulation. A MHD-based commercial computational fluid dynamic (CFD) software FLUENT is used to simulate the LiPb flow. The effect on the MHD pressure drop due to cracks or faults in the coating layer is also considered. The insulating performance requirement for the coating material in DFLL-TBM design is proposed according to the analysis. 展开更多
关键词 magnetohydrodynamic (MHD) pressure drop insulating coating liquid metal lithium-lead
下载PDF
A pressure drop model of post-fracturing shut-in considering the effect of fracturing-fluid imbibition and oil replacement 被引量:2
16
作者 WANG Fei RUAN Yingqi +1 位作者 CHEN Qiaoyun ZHANG Shicheng 《Petroleum Exploration and Development》 CSCD 2021年第6期1440-1449,共10页
Since the production regime of shut-in after fracturing is generally adopted for wells in shale oil reservoir,a shut-in pressure drop model coupling wellbore-fracture network-reservoir oil-water two-phase flow has bee... Since the production regime of shut-in after fracturing is generally adopted for wells in shale oil reservoir,a shut-in pressure drop model coupling wellbore-fracture network-reservoir oil-water two-phase flow has been proposed.The model takes into account the effects of wellbore afterflow,fracture network channeling,and matrix imbibition and oil exchange after stop of pumping.The simulated log-log curve of pressure-drop derivative by the model presents W-shape,reflecting the oil-water displacement law between wellbore,fracture network and matrix,and is divided into eight main control flow stages according to the soaking time.In the initial stage of pressure drop,the afterflow dominates;in the early stage,the pressure drop is controlled by the cross-flow and leakoff of the fracture system,and the fractures close gradually;in the middle stage of pressure drop,matrix imbibition and oil exchange take dominance,and the fracturing fluid loss basically balances with oil replaced from matrix;the late stage of pressure drop is the reservoir boundary control stage,and the leakoff rate of fracturing-fluid and oil exchange rate decrease synchronously till zero.Finally,the fracture network parameters such as half-length of main fracture,main fracture conductivity and secondary fracture density were inversed by fitting the pressure drop data of five wells in Jimsar shale oil reservoir,and the water imbibition volume of matrix and the oil replacement volume in fracture were calculated by this model.The study results provide a theoretical basis for comprehensively evaluating the fracturing effect of shale oil hori-zontal wells and understanding the oil-water exchange law of shale reservoir after fracturing. 展开更多
关键词 shale oil hydraulic fracturing shut-in pressure drop imbibition oil replacement fracture network
下载PDF
Experimental Study on Heat Transfer and Pressure Drop of Micro-Sized Tube Heat Exchanger 被引量:2
17
作者 王秋香 戴传山 《Transactions of Tianjin University》 EI CAS 2014年第1期21-26,共6页
A micro-sized tube heat exchanger(MTHE) was fabricated, and its performance in heat transfer and pressure drop was experimentally studied. The single-phase forced convection heat transfer correlation on the sides of t... A micro-sized tube heat exchanger(MTHE) was fabricated, and its performance in heat transfer and pressure drop was experimentally studied. The single-phase forced convection heat transfer correlation on the sides of the MTHE tubes was proposed and compared with previous experimental data in the Reynolds number range of 500—1 800. The average deviation of the correlation in calculating the Nusselt number was about 6.59%. The entrance effect in the thermal entrance region was discussed. In the same range of Reynolds number, the pressure drop and friction coefficient were found to be considerably higher than those predicted by the conventional correlations. The product of friction factor and Reynolds number was also a constant, but much higher than the conventional. 展开更多
关键词 micro-sized tube heat exchanger heat transfer pressure drop entrance effect
下载PDF
Effect of nozzle geometry on pressure drop in submerged gas injection 被引量:1
18
作者 XIAO Jun-bing YAN Hong-jie LIU Liu 《Journal of Central South University》 SCIE EI CAS CSCD 2019年第8期2068-2076,共9页
Submerged gas injection into liquid leads to complex multiphase flow, in which nozzle geometries are crucial important for the operational expenditure in terms of pressure drop. The influence of the nozzle geometry on... Submerged gas injection into liquid leads to complex multiphase flow, in which nozzle geometries are crucial important for the operational expenditure in terms of pressure drop. The influence of the nozzle geometry on pressure drop between nozzle inlet and outlet has been experimentally studied for different gas flow rates and bath depths. Nozzles with circular, gear-like and four-leaf cross-sectional shape have been studied. The results indicate that, besides the hydraulic diameter of the outlet, the orifice area and the perimeter of the nozzle tip also play significant roles. For the same superficial gas velocity, the average pressure drop from the four-leaf-shaped geometry is the least. The influence of bath depth was found negligible. A correlation for the modified Euler number considering the pressure drop is proposed depending on nozzle geometric parameter and on the modified Froude number with the hydraulic diameter of the nozzle do as characteristic length. 展开更多
关键词 submerged gas injection nozzle geometry hydraulic diameter pressure drop modified Euler number
下载PDF
METHODS FOR CALCULATING SHELL-SIDE CONDENSATION HEAT TRANSFER AND PRESSURE DROP OF RODBAFFLE CONDENSER
19
作者 思勤 刘昌俊 黄鸿鼎 《Chinese Journal of Chemical Engineering》 SCIE EI CAS CSCD 1996年第1期93-97,共5页
1 INTRODUCTIONGentry,Yong and Small [1-3]have described their Rodbaffle heat exchangers,whichare geometrically shell-and-tube exchangers consisting of a series of shell-side bafflesas an array of supporting rods.The s... 1 INTRODUCTIONGentry,Yong and Small [1-3]have described their Rodbaffle heat exchangers,whichare geometrically shell-and-tube exchangers consisting of a series of shell-side bafflesas an array of supporting rods.The supporting-rod matrix creates an unobstructedflow path and makes the flow field in the shell-side of the heat exchangerpredominantly longitudinal bringing along flow-induced tube vibration in a cross flowheat-exchanger.With neither bundle cross flow form drag nor repeated flow reversal ef-fects being present,the shell-side pressure losses in Rodbaffle heat exchangers are low.Rodbaffle heat exchangers also offer an enhanced thermal performance. 展开更多
关键词 CONDENSATION heat transfer pressure drop Rodbaffle CONDENSER
下载PDF
Experimental Investigation of Pressure Drop Hysteresis in a Cocurrent Gas-Liquid Upflow Packed Bed 被引量:1
20
作者 徐红彬 毛在砂 《过程工程学报》 CAS CSCD 北大核心 2001年第3期239-242,共4页
Extensive experimental work on hysteresis in a c℃urrent gas-liquid upflow packed bed was carried out with three kinds of packings and the air-water system. However, only when packed with small glass beads ((1.4 mm) w... Extensive experimental work on hysteresis in a c℃urrent gas-liquid upflow packed bed was carried out with three kinds of packings and the air-water system. However, only when packed with small glass beads ((1.4 mm) was the bed pressure drop hysteresis observed. Two more liquids with different liquid properties were employed to further examine the influence of parameters on pressure drop hysteresis. The similarity of pressure drop hysteresis in packed beds was concluded in combination of experimental evidence reported in literature. 展开更多
关键词 气液固填充塔 同向上流固定 压力降滞 试验
下载PDF
上一页 1 2 250 下一页 到第
使用帮助 返回顶部