In order to provide more grid space for the renewable energy power,the traditional coal-fired power unit should be operated flexibility,especially achieved the deep peak shaving capacity.In this paper,a new scheme usi...In order to provide more grid space for the renewable energy power,the traditional coal-fired power unit should be operated flexibility,especially achieved the deep peak shaving capacity.In this paper,a new scheme using the reheat steam extraction is proposed to further reduce the load far below 50%rated power.Two flexible operation modes of increasing power output mode and reducing fuel mode are proposed in heat discharging process.A 600 MW coal-fired power unit with 50%rated power is chosen as the research model.The results show that the power output is decreased from 300.03 MW to 210.07 MW when the extracted reheat steam flow rate is 270.70 t·h^(-1),which increases the deep peak shaving capacity by 15%rated power.The deep peak shaving time and the thermal efficiency are 7.63 h·d^(-1)and 36.91%respectively for the increasing power output mode,and they are 7.24 h·d^(-1)and 36.58%respectively for the reducing fuel mode.The increasing power output mode has the advantages of higher deep peak shaving time and the thermal efficiency,which is recommended as the preferred scheme for the flexible operation of the coal-fired power unit.展开更多
For the improvement of reheat steam quality and performance of double reheat coal-fired utility boiler under wide load operation, a variety of temperature regulation ways were utilized to adjust the energy distributio...For the improvement of reheat steam quality and performance of double reheat coal-fired utility boiler under wide load operation, a variety of temperature regulation ways were utilized to adjust the energy distribution between different heating surfaces. In this paper, thermodynamic calculation based on the fundamental heat transfer theory was conducted for the analysis of temperature regulation strategy effects to steam temperature. In consideration of the specific overlapping heating surface arrangement, the compartment model was adopted to solve this problem. Response surface methodology(RSM) was used to analysis the effect of each temperature regulating variables on the steam temperature and boiler efficiency;then the polynomial model was fitted to predict the primary and secondary steam temperature simultaneously. Results showed that the flue gas recirculation rate has a relatively significant influence on the steam temperature, the maximum temperature deviation between fitting value and calculation value is 3.85℃ in 75% THA;the quadratic model can well predict the steam temperature under different operation conditions in wide load change. The variation of flue gas baffle has a significant influence on the boiler efficiency, compared to the flue gas recirculation and angle of burner oscillation. The influence of various factors on the reheat steam temperature is flue gas baffle > flue gas recirculation > angle of burner oscillation.展开更多
The thermodynamic(energy and exergy)analysis of a condensate heating system,its segments,and components from a marine steam propulsion plant with steam reheating is performed in this paper.It is found that energy anal...The thermodynamic(energy and exergy)analysis of a condensate heating system,its segments,and components from a marine steam propulsion plant with steam reheating is performed in this paper.It is found that energy analysis of any condensate heating system should be avoided because it is highly influenced by the measuring equipment accuracy and precision.All the components from the observed marine condensate heating system have energy destructions lower than 3 kW,while the energy efficiencies of this system are higher than 99%.The exergy efficiency of closed condensate heaters continuously increases from the lowest to the highest steam pressures(from 70.10%to 92.29%).The ambient temperature variation between 5℃and 45℃notably influences the exergy efficiency change of both low pressure heaters and the low pressure segment equal to 31.61%,12.37%,and 18.35%,respectively.展开更多
基金supported by the National Natural Science Foundation of China(Grant No.52076006)the Inner Mongolia Science and Technology Major Project(Grant No.2021ZD0036)。
文摘In order to provide more grid space for the renewable energy power,the traditional coal-fired power unit should be operated flexibility,especially achieved the deep peak shaving capacity.In this paper,a new scheme using the reheat steam extraction is proposed to further reduce the load far below 50%rated power.Two flexible operation modes of increasing power output mode and reducing fuel mode are proposed in heat discharging process.A 600 MW coal-fired power unit with 50%rated power is chosen as the research model.The results show that the power output is decreased from 300.03 MW to 210.07 MW when the extracted reheat steam flow rate is 270.70 t·h^(-1),which increases the deep peak shaving capacity by 15%rated power.The deep peak shaving time and the thermal efficiency are 7.63 h·d^(-1)and 36.91%respectively for the increasing power output mode,and they are 7.24 h·d^(-1)and 36.58%respectively for the reducing fuel mode.The increasing power output mode has the advantages of higher deep peak shaving time and the thermal efficiency,which is recommended as the preferred scheme for the flexible operation of the coal-fired power unit.
基金Financial support for this work by the National Key Research and Development Program of China(Grant No.2017YFB0602102)。
文摘For the improvement of reheat steam quality and performance of double reheat coal-fired utility boiler under wide load operation, a variety of temperature regulation ways were utilized to adjust the energy distribution between different heating surfaces. In this paper, thermodynamic calculation based on the fundamental heat transfer theory was conducted for the analysis of temperature regulation strategy effects to steam temperature. In consideration of the specific overlapping heating surface arrangement, the compartment model was adopted to solve this problem. Response surface methodology(RSM) was used to analysis the effect of each temperature regulating variables on the steam temperature and boiler efficiency;then the polynomial model was fitted to predict the primary and secondary steam temperature simultaneously. Results showed that the flue gas recirculation rate has a relatively significant influence on the steam temperature, the maximum temperature deviation between fitting value and calculation value is 3.85℃ in 75% THA;the quadratic model can well predict the steam temperature under different operation conditions in wide load change. The variation of flue gas baffle has a significant influence on the boiler efficiency, compared to the flue gas recirculation and angle of burner oscillation. The influence of various factors on the reheat steam temperature is flue gas baffle > flue gas recirculation > angle of burner oscillation.
基金This research is supported by the Croatian Science Foundation under the project IP-2018-01-3739,CEEPUS network CIII-HR-0108,European Regional Development Fund under the grant KK.01.1.1.01.0009(DATACROSS)project CEKOM under the grant KK.01.2.2.03.0004,CEI project“COVIDAi”(305.6019-20)University of Rijeka Scientific Grants uniri-tehnic-18-275-1447,uniritehnic-18-18-1146 and uniri-tehnic-18-14.
文摘The thermodynamic(energy and exergy)analysis of a condensate heating system,its segments,and components from a marine steam propulsion plant with steam reheating is performed in this paper.It is found that energy analysis of any condensate heating system should be avoided because it is highly influenced by the measuring equipment accuracy and precision.All the components from the observed marine condensate heating system have energy destructions lower than 3 kW,while the energy efficiencies of this system are higher than 99%.The exergy efficiency of closed condensate heaters continuously increases from the lowest to the highest steam pressures(from 70.10%to 92.29%).The ambient temperature variation between 5℃and 45℃notably influences the exergy efficiency change of both low pressure heaters and the low pressure segment equal to 31.61%,12.37%,and 18.35%,respectively.