期刊文献+
共找到3篇文章
< 1 >
每页显示 20 50 100
Hydrogen sulfide responsive nanoplatforms: Novel gas responsive drug delivery carriers for biomedical applications
1
作者 Jiafeng Zou Zeting Yuan +9 位作者 Xiaojie Chen You Chen Min Yao Yang Chen Xiang Li Yi Chen Wenxing Ding Chuanhe Xia Yuzheng Zhao Feng Gao 《Asian Journal of Pharmaceutical Sciences》 SCIE CAS 2024年第1期1-17,共17页
Hydrogen sulfide(H_(2)S)is a toxic,essential gas used in various biological and physical processes and has been the subject of many targeted studies on its role as a new gas transmitter.These studies have mainly focus... Hydrogen sulfide(H_(2)S)is a toxic,essential gas used in various biological and physical processes and has been the subject of many targeted studies on its role as a new gas transmitter.These studies have mainly focused on the production and pharmacological side effects caused by H_(2)S.Therefore,effective strategies to remove H_(2)S has become a key research topic.Furthermore,the development of novel nanoplatforms has provided new tools for the targeted removal of H_(2)S.This paper was performed to review the association between H_(2)S anddisease,relatedH_(2)S inhibitory drugs,aswell as H_(2)S responsive nanoplatforms(HRNs).This review first analyzed the role of H_(2)S in multiple tissues and conditions.Second,common drugs used to eliminate H_(2)S,as well as their potential for combination with anticancer agents,were summarized.Not only the existing studies on HRNs,but also the inhibition H_(2)S combined with different therapeutic methods were both sorted out in this review.Furthermore,this review provided in-depth analysis of the potential of HRNs about treatment or detection in detail.Finally,potential challenges of HRNs were proposed.This study demonstrates the excellent potential of HRNs for biomedical applications. 展开更多
关键词 hydrogen sulfide Disease mechanisms Removal of hydrogen sulfide Responsive nanoplatforms CHALLENGES Biomedical applications
下载PDF
Application and Regeneration of a Non-Aqueous System of Cu/HCl and DMF for the Oxidation of Hydrogen Sulfide in Natural Gas 被引量:1
2
作者 Wang Yingjie Liu Siyuan +3 位作者 Wang Xuening Liu Zhihao Chen Hongyuan Qiu Kui 《China Petroleum Processing & Petrochemical Technology》 SCIE CAS CSCD 2023年第3期71-82,共12页
A copper-based non-aqueous-phase desulfurization agent is prepared by adding CuCl_(2) to the solvent N,Ndimethylformamide(DMF).Static desulfurization experiments show that the agent has high efficiency.However,the des... A copper-based non-aqueous-phase desulfurization agent is prepared by adding CuCl_(2) to the solvent N,Ndimethylformamide(DMF).Static desulfurization experiments show that the agent has high efficiency.However,the desulfurization reaction leads to the formation of a copper sulfide precipitate.It is found that the addition of chloride ions in the form of hydrochloric acid or potassium chloride prevents the formation of copper sulfide,and elemental sulfur is precipitated instead.The efficient absorption of H2S by the Cu/HCl–DMF agent relies on the rapid coordination of Cu^(2+)with DMF,Cl^(−),and H2S molecules to form a[Cu(DMF)_(n−p)(HS−)_(p)(Cl−)_(m)]_((2−p−m))+complex.The desulfurization agent has a sulfur capacity of up to 9.81 g/L when used in static bubble desulfurization at atmospheric pressure.The system has low viscosity and good chemical and thermal stability.It can be rapidly regenerated through continuous oxidation.After five repetitions of the regeneration procedure,the sulfur capacity reaches more than 91%of the initial capacity,indicating the potential of the system for commercial applications. 展开更多
关键词 hydrogen sulfide removal wet oxidation DMF CuCl_(2)
下载PDF
Simulation study of hydrogen sulfide removal in underground gas storage converted from the multilayered sour gas field
3
作者 Yi Yang Longxin Li +4 位作者 Xia Wang Nan Qin Ruihan Zhang Yulong Zhao Ye Tian 《International Journal of Coal Science & Technology》 EI CAS CSCD 2023年第5期107-118,共12页
A simulation study was carried out to investigate the temporal evolution of H_(2)S in the Huangcaoxia underground gas storage (UGS), which is converted from a depleted sulfur-containing gas field. Based on the rock an... A simulation study was carried out to investigate the temporal evolution of H_(2)S in the Huangcaoxia underground gas storage (UGS), which is converted from a depleted sulfur-containing gas field. Based on the rock and fluid properties of the Huangcaoxia gas field, a multilayered model was built. The upper layer Jia-2 contains a high concentration of H_(2)S (27.2 g/m^(3)), and the lower layer Jia-1 contains a low concentration of H_(2)S (14.0 mg/m^(3)). There is also a low-permeability interlayer between Jia-1 and Jia-2. The multi-component fluid characterizations for Jia-1 and Jia-2 were implemented separately using the Peng-Robinson equation of state in order to perform the compositional simulation. The H_(2)S concentration gradually increased in a single cycle and peaked at the end of the production season. The peak H_(2)S concentration in each cycle showed a decreasing trend when the recovery factor (RF) of the gas field was lower than 70%. When the RF was above 70%, the peak H_(2)S concentration increased first and then decreased. A higher reservoir RF, a higher maximum working pressure, and a higher working gas ratio will lead to a higher H_(2)S removal efficiency. Similar to developing multi-layered petroleum fields, the operation of multilayered gas storage can also be divided into multi-layer commingled operation and independent operation for different layers. When the two layers are combined to build the storage, the sweet gas produced from Jia-1 can spontaneously mix with the sour gas produced from Jia-2 within the wellbore, which can significantly reduce the overall H_(2)S concentration in the wellstream. When the working gas volume is set constant, the allocation ratio between the two layers has little effect on the H_(2)S removal. After nine cycles, the produced gas’s H_(2)S concentration can be lowered to 20 mg/m^(3). Our study recommends combining the Jia-2 and Jia-1 layers to build the Huangcaoxia underground gas storage. This plan can quickly reduce the H_(2)S concentration of the produced gas to 20 mg/m^(3), thus meeting the gas export standards as well as the HSE (Health, Safety, and Environment) requirements in the field. This study helps the engineers understand the H_(2)S removal for sulfur-containing UGS as well as provides technical guidelines for converting other multilayered sour gas fields into underground storage sites. 展开更多
关键词 Underground gas storage Multilayered gas field-Sour gas reservoir hydrogen sulfide removal.Compositional simulation
下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部