期刊文献+
共找到2篇文章
< 1 >
每页显示 20 50 100
Accuracy and repeatability of direct ciliary sulcus diameter measurements by full-scale 50-megahertz ultrasound biomicroscopy 被引量:7
1
作者 LI De-jiao WANG Ning-li +3 位作者 CHEN Shu LI Shu-ning MU Da-peng WANG Tao 《Chinese Medical Journal》 SCIE CAS CSCD 2009年第8期955-959,共5页
Background Phakic intraocular lens (pIOL) implantation has been a popular means for the treatment of high ametropia Measurements of ciliary sulcus diameter is important for pIOL size determining. But till now, no pe... Background Phakic intraocular lens (pIOL) implantation has been a popular means for the treatment of high ametropia Measurements of ciliary sulcus diameter is important for pIOL size determining. But till now, no perfect system can directly measure it. The present study was to evaluate the accuracy, repeatability and reproducibility of direct sulcus diameter measurements obtained by a full-scale 50-megahertz (MHz) ultrasound biomicroscopy (UBM). Methods A fresh cadaver human eye with a scale marker inserted through the posterior chamber plane from 3 o'clock to 9 o'clock meridian and 30 randomly selected eyes from 30 normal subjects were scanned by full-scale 50-MHz UBM in horizontal meridional scan plane. The distance between the scales and the whole length of the marker inside the cadaver eye were measured by the same observer using the "built-in" measurement tools and the indicating error of instrument was calculated. Reproducibility of the measurement was evaluated in 30 eyes by 2 operators using Blander and Altman plot test. Repeatability was evaluated from 10 successive eyes randomly selected from the 30 eyes by one operator. Results On a scale of 1 mm, the greatest indicating error was 40μm; the mean largest indicating error of 1 mm scale from the 10 images was (26_±14) μm; on a scale of 11 mm, the greatest indicating error was 70 μm; the error rate was 0.64%. The mean length of the needle inside the eye of the 10 images was 11.05 mm, with the mean indicating error of 47 μm, the average error rate was 0.43%. For ciliary sulcus diameter measurements in vivo, the coefficient of variation was 0.38%; the coefficients of repeatability for intra-observer and inter-observer measurements were 1.99% and 2.55%, respectively. The limits of agreement for intra-observer and inter-observer measurement were -0.41 mm to 0.48 mm and -0.59 mm to 0.58 mm, respectively. Conclusion The full-scale 50-MHz UBM can be a high accuracy and good repeatability means for direct measuring the ciliary sulcus diameter and useful for size determining of posterior chamber pIOL. 展开更多
关键词 ciliary sulcus diameter ultrasound biomicroscopy ACCURACY repeatability and reproducibility
原文传递
R&R Analysis for Measurement System Using Moving Range
2
作者 MA Yi-zhong 1,2, ZHAO Feng-yu2, XU Ji-chao21.College of Astronautics Engineering, Northwestern Polytechnic University, Xi′an, 710072, China2.Research Department of Quality Engineering, Zhengzhou Institute of Aeronautics, Zhengzhou, 450005, China 《Systems Science and Systems Engineering》 CSCD 2002年第3期290-295,共6页
In order to control and continuous improve a production process, a good measurement system is essential. The assessment of a measurement system is known as a gauge repeatability and reproducibility(R&R) analysis. ... In order to control and continuous improve a production process, a good measurement system is essential. The assessment of a measurement system is known as a gauge repeatability and reproducibility(R&R) analysis. In this paper, the traditional method, analysis of variance (ANOVA), is reviewed and some drawbacks are pointed out. Then a new approach is introduced to estimate R&R. In the last part, an example is presented to show the efficiency of this approach and to demonstrate its application for front-line operation. 展开更多
关键词 repeatability and reproducibility ANOVA moving range measurement system
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部