The stenosis in the artery, which reduces the flow passage to blood, is a common cardiovascular disease that is responsible even for cardiac arrest sometimes. The hemodynaics reveals that the severe blockage in an art...The stenosis in the artery, which reduces the flow passage to blood, is a common cardiovascular disease that is responsible even for cardiac arrest sometimes. The hemodynaics reveals that the severe blockage in an artery due to stenosis generates pressure tangential stress that impacts adversely on the arterial wall downstream to stenosis and weakens the arterial wall. The site of weakened wall in the artery generates post stenotic dilatation. The objective of this paper is to study flow of blood, of non-Newtonian in nature described by Herschel-Bulkley model, in a diseased artery suffering with partly overlapped two stenoses and a dilatation distal to the stenoses. A mathematical model, describing the blood flow, has been derived using Navier-Stokes equations along with the prescribed geometry of the diseased artery. The expressions of velocity profile, resistive impedance to flow and wall shear stress (skin-friction) are derived. The effect of inclination of the vessel on the resistive impedance to flow is discussed along with the effect of rheological and geometrical parameters on the resistive impedance to flow and skin friction.展开更多
The storage of long bunches for large time intervals needs flattened stationary buckets with a large bucket height. Collective effects from the space charge and resistive impedance are studied by looking at the incohe...The storage of long bunches for large time intervals needs flattened stationary buckets with a large bucket height. Collective effects from the space charge and resistive impedance are studied by looking at the incoherent particle motion for the matched and mismatched bunches. Increasing the RF amplitude with particle number provides r.m.s wise matching for modest intensities. The incoherent motion of large amplitude particles depends on the details of the RF system. The resulting debunching process is a combination of the too small full RF acceptance together with the mismatch, enhanced by the collective effects. Irregular single particle motion is not associated with the coherent dipole instability. For the stationary phase space distribution of the Hofmann-Pedersen approach and for the dual harmonic RF system, stability limits are presented, which are too low if using realistic input distributions. For single and dual harmonic RF system with d=0.31, the tracking results are shown for intensities, by a factor of 3 above the threshold values. Small resistive impedances lead to coherent oscillations around the equilibrium phase value, as energy loss by resistive impedance is compensated by the energy gain of the RF system.展开更多
The present work is concerned with the analysis of an axi-symmetric flow of blood through coaxial tubes where the outer tube has an axially symmetric mild stenosis and the inner tube has a balloon which is axi-symmetr...The present work is concerned with the analysis of an axi-symmetric flow of blood through coaxial tubes where the outer tube has an axially symmetric mild stenosis and the inner tube has a balloon which is axi-symmetric in nature. The mild stenosis approximation is used to solve the present problem. The effect of the volume fraction density of the particles, the maximum height attained by the balloon, the radius of the inner tube, which keeps the balloon in position k, and the axial displacement of the balloon have been studied. Flow parameters such as the resistive impedance, the wall shear stress distribution in the stenotic region and its magnitude at the stenosis throat have been computed for different parameters. It is observed that the resistance to flow decreases with increasing values of the axial displacement of the balloon, while the resistance to flow increases with the volume fraction density of the particles, the radius of the inner tube, which keeps the balloon in position k, and the maximum height attained by the balloon. The wall shear stress distribution in the stenotic region possesses a character similar to the resistance to flow with respect to any parameter.展开更多
Graphene (G) was dispersed uniformly in water and used as an inhibitor in waterborne epoxy coatings. The effect of dispersed G on anticorrosion performance of epoxy coatings was evaluated. The composite coatings dis...Graphene (G) was dispersed uniformly in water and used as an inhibitor in waterborne epoxy coatings. The effect of dispersed G on anticorrosion performance of epoxy coatings was evaluated. The composite coatings displayed outstanding barrier properties against H20 molecule compared to the neat epoxy coating. Open circuit potential (OCP), Tafel and electrochemical impedance spectroscopy (EIS) analysis confirmed that the corrosion rate exhibited by composite coatings with 0.5 wt% G was an order of magnitude lower than that of neat epoxy coating. Salt spray test results revealed superior corrosion resistance offered by the composite coating.展开更多
文摘The stenosis in the artery, which reduces the flow passage to blood, is a common cardiovascular disease that is responsible even for cardiac arrest sometimes. The hemodynaics reveals that the severe blockage in an artery due to stenosis generates pressure tangential stress that impacts adversely on the arterial wall downstream to stenosis and weakens the arterial wall. The site of weakened wall in the artery generates post stenotic dilatation. The objective of this paper is to study flow of blood, of non-Newtonian in nature described by Herschel-Bulkley model, in a diseased artery suffering with partly overlapped two stenoses and a dilatation distal to the stenoses. A mathematical model, describing the blood flow, has been derived using Navier-Stokes equations along with the prescribed geometry of the diseased artery. The expressions of velocity profile, resistive impedance to flow and wall shear stress (skin-friction) are derived. The effect of inclination of the vessel on the resistive impedance to flow is discussed along with the effect of rheological and geometrical parameters on the resistive impedance to flow and skin friction.
基金Supported by National Natural Science Foundation of China (10075065)
文摘The storage of long bunches for large time intervals needs flattened stationary buckets with a large bucket height. Collective effects from the space charge and resistive impedance are studied by looking at the incoherent particle motion for the matched and mismatched bunches. Increasing the RF amplitude with particle number provides r.m.s wise matching for modest intensities. The incoherent motion of large amplitude particles depends on the details of the RF system. The resulting debunching process is a combination of the too small full RF acceptance together with the mismatch, enhanced by the collective effects. Irregular single particle motion is not associated with the coherent dipole instability. For the stationary phase space distribution of the Hofmann-Pedersen approach and for the dual harmonic RF system, stability limits are presented, which are too low if using realistic input distributions. For single and dual harmonic RF system with d=0.31, the tracking results are shown for intensities, by a factor of 3 above the threshold values. Small resistive impedances lead to coherent oscillations around the equilibrium phase value, as energy loss by resistive impedance is compensated by the energy gain of the RF system.
文摘The present work is concerned with the analysis of an axi-symmetric flow of blood through coaxial tubes where the outer tube has an axially symmetric mild stenosis and the inner tube has a balloon which is axi-symmetric in nature. The mild stenosis approximation is used to solve the present problem. The effect of the volume fraction density of the particles, the maximum height attained by the balloon, the radius of the inner tube, which keeps the balloon in position k, and the axial displacement of the balloon have been studied. Flow parameters such as the resistive impedance, the wall shear stress distribution in the stenotic region and its magnitude at the stenosis throat have been computed for different parameters. It is observed that the resistance to flow decreases with increasing values of the axial displacement of the balloon, while the resistance to flow increases with the volume fraction density of the particles, the radius of the inner tube, which keeps the balloon in position k, and the maximum height attained by the balloon. The wall shear stress distribution in the stenotic region possesses a character similar to the resistance to flow with respect to any parameter.
基金supported by the National Natural Science Foundation of China (No.41506098)the China Postdoctoral Science Foundation (No.2015M580528)the Open Fund Project of Key Laboratory of Marine Materials and Related Technologies (No.LMMTKFKT-2014-008) in the Chinese Academy of Sciences
文摘Graphene (G) was dispersed uniformly in water and used as an inhibitor in waterborne epoxy coatings. The effect of dispersed G on anticorrosion performance of epoxy coatings was evaluated. The composite coatings displayed outstanding barrier properties against H20 molecule compared to the neat epoxy coating. Open circuit potential (OCP), Tafel and electrochemical impedance spectroscopy (EIS) analysis confirmed that the corrosion rate exhibited by composite coatings with 0.5 wt% G was an order of magnitude lower than that of neat epoxy coating. Salt spray test results revealed superior corrosion resistance offered by the composite coating.