期刊文献+
共找到109,510篇文章
< 1 2 250 >
每页显示 20 50 100
A study on the temperature sensitivity of NMR porosity in porous media based on the intensity of magnetization Dedicated to the special issue “Magnetic Resonance in Porous Media”
1
作者 Lu Zhang Lizhi Xiao +4 位作者 Wensheng Wu Guangzhi Liao Yan Zhang Sihui Luo Xinglong Lei 《Magnetic Resonance Letters》 2024年第1期28-39,共12页
The measurement of nuclear magnetic resonance(NMR)porosity is affected by temperature.Without considering the impact of NMR logging tools,this phenomenon is mainly caused by variations in magnetization intensity of th... The measurement of nuclear magnetic resonance(NMR)porosity is affected by temperature.Without considering the impact of NMR logging tools,this phenomenon is mainly caused by variations in magnetization intensity of the measured system due to temperature fluctuations and difference between the temperature of the porous medium and calibration sample.In this study,the effect of temperature was explained based on the thermodynamic theory,and the rules of NMR porosity responses to temperature changes were identified through core physics experiments.In addition,a method for correcting the influence of temperature on NMR porosity measurement was proposed,and the possible factors that may affect its application were also discussed. 展开更多
关键词 nmr porosity Temperature Porous media Intensity of magnetization
下载PDF
Laplace NMR谱图重建——从经典正则化到深度学习
2
作者 杨钰 陈博 +3 位作者 吴柳滨 林恩平 黄玉清 陈忠 《波谱学杂志》 CAS 2024年第2期191-208,共18页
拉普拉斯核磁共振(Laplace NMR)可以提供待测样品的扩散系数或弛豫时间等物理参数信息,是用于研究分子化学结构、动力学和相互作用的强大工具.Laplace NMR的适用性很大程度上取决于拉普拉斯逆变换相关的信号处理算法的性能.在本文中,我... 拉普拉斯核磁共振(Laplace NMR)可以提供待测样品的扩散系数或弛豫时间等物理参数信息,是用于研究分子化学结构、动力学和相互作用的强大工具.Laplace NMR的适用性很大程度上取决于拉普拉斯逆变换相关的信号处理算法的性能.在本文中,我们首先讨论了Laplace NMR谱图重建问题的不适定性,接着回顾了经典的基于正则化约束的重建算法,并介绍了目前前沿的深度学习算法在处理Laplace反演问题方面的应用,最后总结了这些算法的优缺点,并对Laplace NMR信号处理方法未来改进方向进行了展望. 展开更多
关键词 拉普拉斯核磁共振 扩散核磁共振 扩散排序谱 拉普拉斯反演变换 深度学习
下载PDF
基于NMR的非饱和土相对渗透系数快速预测新方法
3
作者 陶高梁 彭寅杰 +4 位作者 陈银 肖衡林 罗晨晨 钟楚珩 雷达 《岩土工程学报》 EI CAS CSCD 北大核心 2024年第3期470-479,共10页
非饱和土的渗透系数作为研究非饱和土中水分运移的重要参数,直接测量方法原理简明但试样尺寸较大,耗时较长;土-水特征曲线(SWCC)间接预测方法由于需要获取土-水特征曲线,同样较为耗时,工作量较大。为此,结合核磁共振(NMR)理论与渗流理... 非饱和土的渗透系数作为研究非饱和土中水分运移的重要参数,直接测量方法原理简明但试样尺寸较大,耗时较长;土-水特征曲线(SWCC)间接预测方法由于需要获取土-水特征曲线,同样较为耗时,工作量较大。为此,结合核磁共振(NMR)理论与渗流理论提出了不同孔径孔隙通道渗透系数与弛豫时间的关系,通过对不同大小孔隙通道渗透系数进行累加,提出了基于核磁共振的饱和/非饱和土渗透系数预测模型和快速预测方法。为验证模型的合理性,以湖南黏土为研究对象,进行了不同初始孔隙比试样脱湿、吸湿过程以及饱和状态下的95次核磁共振试验,获取相应的NMR曲线,采用瞬时剖面法获取不同初始孔隙比试样非饱和相对渗透系数,并与该模型预测值对比。研究发现:利用脱湿、吸湿过程不同含水率下NMR曲线以及饱和状态的NMR曲线均具有较好的预测效果,但基于饱和状态下试样的NMR曲线预测效果相对最好,测量成本和耗时也最小,因此建议采用饱和状态试样NMR曲线直接预测非饱和相对渗透系数。 展开更多
关键词 核磁共振 饱和/非饱和渗透系数 孔隙通道 弛豫时间
下载PDF
基于小型化原子磁力计的零场NMR波谱仪搭建与测试
4
作者 付方跃 郭清乾 +5 位作者 冯晓宇 徐佳玉 姚泽坤 胡涛 杨晓冬 常严 《波谱学杂志》 CAS 2024年第1期87-98,共12页
常规高场NMR波谱仪依托超导技术,其体积大、维护成本高,且存在样本磁化率不均匀导致的谱线展宽现象,零场或近零场NMR技术则可实现有效互补.本文自主搭建了一套基于小型原子磁力计的可移动零场NMR波谱仪,采用以多功能采集卡(National Ins... 常规高场NMR波谱仪依托超导技术,其体积大、维护成本高,且存在样本磁化率不均匀导致的谱线展宽现象,零场或近零场NMR技术则可实现有效互补.本文自主搭建了一套基于小型原子磁力计的可移动零场NMR波谱仪,采用以多功能采集卡(National Instruments PCIe-6353)为核心的集成控制系统,仪器主磁场强度小于1nT,可实现高分辨率的J-耦合谱采集.为实现对自旋体系的有效操控,利用样品绝热初态的单脉冲激发实现对三轴脉冲线圈的精确标定.在此基础上,使用改进的组合脉冲序列实现了在^(13)C-^(1)H异核体系下的单自旋选择性操控,验证了零场NMR波谱仪的有效性. 展开更多
关键词 零场核磁共振 J-耦合谱 原子磁力计 单自旋操控
下载PDF
High-grade pancreatic intraepithelial neoplasia diagnosed based on changes in magnetic resonance cholangiopancreatography findings:A case report 被引量:1
5
作者 Nao Furuya Atsushi Yamaguchi +13 位作者 Naohiro Kato Syuhei Sugata Takuro Hamada Takeshi Mizumoto Yuzuru Tamaru Ryusaku Kusunoki Toshio Kuwai Hirotaka Kouno Kazuya Kuraoka Yoshiyuki Shibata Sho Tazuma Takeshi Sudo Hiroshi Kohno Shiro Oka 《World Journal of Clinical Cases》 SCIE 2024年第8期1487-1496,共10页
BACKGROUND High-grade pancreatic intraepithelial neoplasia(PanIN)exhibits no mass and is not detected by any examination modalities.However,it can be diagnosed by pancreatic juice cytology from indirect findings.Most ... BACKGROUND High-grade pancreatic intraepithelial neoplasia(PanIN)exhibits no mass and is not detected by any examination modalities.However,it can be diagnosed by pancreatic juice cytology from indirect findings.Most previous cases were diagnosed based on findings of a focal stricture of the main pancreatic duct(MPD)and caudal MPD dilatation and subsequent pancreatic juice cytology using endoscopic retrograde cholangiopancreatography(ERCP).We experienced a case of high-grade PanIN with an unclear MPD over a 20-mm range,but without caudal MPD dilatation on magnetic resonance cholangiopancreatography(MRCP).CASE SUMMARY A 60-year-old female patient underwent computed tomography for a follow-up of uterine cancer post-excision,which revealed pancreatic cysts.MRCP revealed an unclear MPD of the pancreatic body at a 20-mm length without caudal MPD dilatation.Thus,course observation was performed.After 24 mo,MRCP revealed an increased caudal MPD caliber and a larger pancreatic cyst.We performed ERCP and detected atypical cells suspected of adenocarcinoma by serial pancreatic juice aspiration cytology examination.We performed a distal pancreatectomy and obtained a histopathological diagnosis of high-grade PanIN.Pancreatic parenchyma invasion was not observed,and curative resection was achieved.CONCLUSION High-grade Pan-IN may cause MPD narrowing in a long range without caudal MPD dilatation. 展开更多
关键词 Pancreatic cancer Pancreatic intraepithelial neoplasm High-grade pancreatic intraepithelial neoplasm Magnetic resonance cholangiopancreatography Carcinoma in situ Case report
下载PDF
舒肝宁注射液的^(1)H-NMR指纹图谱分析
6
作者 何峰 朱彤彤 +4 位作者 韩春月 张昀 杨翠萍 韩立峰 付志飞 《中南药学》 CAS 2024年第3期753-759,共7页
目的对舒肝宁注射液的^(1)H-NMR指纹图谱进行分析,为其质量控制标准技术升级提供参考依据。方法使用Noesygppr1d脉冲序列[recycle delay(RD)-90°-t 1-90°-t_(m)-90°-ACQ]采集1H-NMR谱图,质子共振频率为600.13 MHz,实验... 目的对舒肝宁注射液的^(1)H-NMR指纹图谱进行分析,为其质量控制标准技术升级提供参考依据。方法使用Noesygppr1d脉冲序列[recycle delay(RD)-90°-t 1-90°-t_(m)-90°-ACQ]采集1H-NMR谱图,质子共振频率为600.13 MHz,实验温度为298 K,通过方法学考察验证分析方法可靠性,采用相关系数法和夹角余弦法评价不同批次舒肝宁注射液样品的相似度。结果对舒肝宁注射液的^(1)H-NMR指纹图谱进行分析,共鉴定出88种化学成分,且不同批次的舒肝宁注射液具有较高的相似度。结论建立了一种基于^(1)H-NMR的舒肝宁注射液质量控制方法,可为舒肝宁注射液技术升级提供参考依据。 展开更多
关键词 舒肝宁注射液 1H-nmr 指纹图谱 相似度
下载PDF
Parametric resonance of axially functionally graded pipes conveying pulsating fluid
7
作者 Jie JING Xiaoye MAO +1 位作者 Hu DING Liqun CHEN 《Applied Mathematics and Mechanics(English Edition)》 SCIE EI CSCD 2024年第2期239-260,共22页
Based on the generalized Hamilton's principle,the nonlinear governing equation of an axially functionally graded(AFG)pipe is established.The non-trivial equilibrium configuration is superposed by the modal functio... Based on the generalized Hamilton's principle,the nonlinear governing equation of an axially functionally graded(AFG)pipe is established.The non-trivial equilibrium configuration is superposed by the modal functions of a simply supported beam.Via the direct multi-scale method,the response and stability boundary to the pulsating fluid velocity are solved analytically and verified by the differential quadrature element method(DQEM).The influence of Young's modulus gradient on the parametric resonance is investigated in the subcritical and supercritical regions.In general,the pipe in the supercritical region is more sensitive to the pulsating excitation.The nonlinearity changes from hard to soft,and the non-trivial equilibrium configuration introduces more frequency components to the vibration.Besides,the increasing Young's modulus gradient improves the critical pulsating flow velocity of the parametric resonance,and further enhances the stability of the system.In addition,when the temperature increases along the axial direction,reducing the gradient parameter can enhance the response asymmetry.This work further complements the theoretical analysis of pipes conveying pulsating fluid. 展开更多
关键词 pipe conveying fluid axially functionally graded supercritical resonance multi-scale method parametric resonance
下载PDF
Enhanced resonance frequency in Co2FeAl thin film with different thicknesses grown on flexible graphene substrate
8
作者 周偲 袁少康 +8 位作者 朱登玉 白宇明 王韬 刘福福 潘禄禄 冯存芳 张博涵 何大平 汪胜祥 《Chinese Physics B》 SCIE EI CAS CSCD 2024年第3期618-622,共5页
The flexible materials exhibit more favorable properties than most rigid substrates in flexibility,weight saving,mechanical reliability,and excellent environmental toughness.Particularly,flexible graphene film with un... The flexible materials exhibit more favorable properties than most rigid substrates in flexibility,weight saving,mechanical reliability,and excellent environmental toughness.Particularly,flexible graphene film with unique mechanical properties was extensively explored in high frequency devices.Herein,we report the characteristics of structure and magnetic properties at high frequency of Co2FeAl thin film with different thicknesses grown on flexible graphene substrate at room temperature.The exciting finding for the columnar structure of Co2FeAl thin film lays the foundation for excellent high frequency property of Co2FeAl/flexible graphene structure.In-plane magnetic anisotropy field varying with increasing thickness of Co2FeAl thin film can be obtained by measurement of ferromagnetic resonance,which can be ascribed to the enhancement of crystallinity and the increase of grain size.Meanwhile,the resonance frequency which can be achieved by the measurement of vector network analyzer with the microstrip method increases with increasing thickness of Co2FeAl thin film.Moreover,in our case with graphene film,the resonance magnetic field is quite stable though folded for twenty cycles,which demonstrates that good flexibility of graphene film and the stability of high frequency magnetic property of Co2FeAl thin film grown on flexible graphene substrate.These results are promising for the design of microwave devices and wireless communication equipment. 展开更多
关键词 enhanced resonance frequency magnetic resonance field flexible graphene substrate
下载PDF
Staging liver fibrosis with various diffusion-weighted magnetic resonance imaging models
9
作者 Yan-Li Jiang Juan Li +6 位作者 Peng-Fei Zhang Feng-Xian Fan Jie Zou Pin Yang Peng-Fei Wang Shao-Yu Wang Jing Zhang 《World Journal of Gastroenterology》 SCIE CAS 2024年第9期1164-1176,共13页
BACKGROUND Diffusion-weighted imaging(DWI)has been developed to stage liver fibrosis.However,its diagnostic performance is inconsistent among studies.Therefore,it is worth studying the diagnostic value of various diff... BACKGROUND Diffusion-weighted imaging(DWI)has been developed to stage liver fibrosis.However,its diagnostic performance is inconsistent among studies.Therefore,it is worth studying the diagnostic value of various diffusion models for liver fibrosis in one cohort.AIM To evaluate the clinical potential of six diffusion-weighted models in liver fibrosis staging and compare their diagnostic performances.METHODS This prospective study enrolled 59 patients suspected of liver disease and scheduled for liver biopsy and 17 healthy participants.All participants underwent multi-b value DWI.The main DWI-derived parameters included Mono-apparent diffusion coefficient(ADC)from mono-exponential DWI,intravoxel incoherent motion model-derived true diffusion coefficient(IVIM-D),diffusion kurtosis imaging-derived apparent diffusivity(DKI-MD),stretched exponential model-derived distributed diffusion coefficient(SEM-DDC),fractional order calculus(FROC)model-derived diffusion coefficient(FROC-D)and FROC model-derived microstructural quantity(FROC-μ),and continuous-time random-walk(CTRW)model-derived anomalous diffusion coefficient(CTRW-D)and CTRW model-derived temporal diffusion heterogeneity index(CTRW-α).The correlations between DWI-derived parameters and fibrosis stages and the parameters’diagnostic efficacy in detecting significant fibrosis(SF)were assessed and compared.RESULTS CTRW-D(r=-0.356),CTRW-α(r=-0.297),DKI-MD(r=-0.297),FROC-D(r=-0.350),FROC-μ(r=-0.321),IVIM-D(r=-0.251),Mono-ADC(r=-0.362),and SEM-DDC(r=-0.263)were significantly correlated with fibrosis stages.The areas under the ROC curves(AUCs)of the combined index of the six models for distinguishing SF(0.697-0.747)were higher than each of the parameters alone(0.524-0.719).The DWI models’ability to detect SF was similar.The combined index of CTRW model parameters had the highest AUC(0.747).CONCLUSION The DWI models were similarly valuable in distinguishing SF in patients with liver disease.The combined index of CTRW parameters had the highest AUC. 展开更多
关键词 Liver fibrosis Magnetic resonance imaging Diffusion-weighted magnetic resonance Liver biopsy Significant fibrosis
下载PDF
The breaking of spin symmetry in the single-particle resonances in deformed nuclei
10
作者 Zhen-Yu Zheng Shou-Wan Chen Quan Liu 《Nuclear Science and Techniques》 SCIE EI CAS CSCD 2024年第3期237-245,共9页
The exploration of spin symmetry (SS) in nuclear physics has been instrumental in identifying atomic nucleus structures.In this study,we solve the Dirac equation from the relativistic mean field (RMF) in complex momen... The exploration of spin symmetry (SS) in nuclear physics has been instrumental in identifying atomic nucleus structures.In this study,we solve the Dirac equation from the relativistic mean field (RMF) in complex momentum representation.We investigated SS and its breaking in single-particle resonant states within deformed nuclei,with a focus on the illustrative nucleus168Er.This was the initial discovery of a resonant spin doublet in a deformed nucleus,with the expectation of the SS approaching the continuum threshold.With increasing single-particle energy,the splitting of the resonant spin doublets widened significantly.This escalating splitting implies diminishing adherence to the SS,indicating a departure from the expected behavior as the energy levels increase.We also analyzed the width of the resonant states,showing that lower orbital angular momentum resonances possess shorter decay times and that SS is preserved within broad resonant doublets,as opposed to narrow resonant doublets.Comparing the radial density of the upper components for the bound-state and resonant-state doublets,it becomes evident that while SS is well-preserved in the bound states,it deteriorates in the resonant states.The impact of nuclear deformation (β_(2)) on SS was examined,demonstrating that an increase in β_(2) resulted in higher energy and width splitting in the resonant spin doublets,which is attributed to increased component mixing.Furthermore,the sensitivity of spin doublets to various potential parameters such as surface diffuseness (a),radius (R),and depth (Σ0) is discussed,emphasizing the role of these parameters in SS.This study provides valuable insights into the behavior of spin doublets in deformed nuclei and their interplay with the nuclear structure,thereby advancing our understanding of SS in the resonance state. 展开更多
关键词 Spin symmetry Resonant states Deformed nuclei Complex-momentum representation
下载PDF
An underdamped and delayed tri-stable model-based stochastic resonance
11
作者 靳艳飞 王昊天 张婷婷 《Chinese Physics B》 SCIE EI CAS CSCD 2024年第1期280-286,共7页
Stochastic resonance(SR) is investigated in an underdamped tri-stable potential system driven by Gaussian colored noise and a periodic excitation, where both displacement and velocity time-delayed states feedback are ... Stochastic resonance(SR) is investigated in an underdamped tri-stable potential system driven by Gaussian colored noise and a periodic excitation, where both displacement and velocity time-delayed states feedback are considered. It is challenging to study SR in a second-order delayed multi-stable system analytically. In this paper, the improved energy envelope stochastic average method is developed to derive the analytical expressions of stationary probability density(SPD)and spectral amplification. The effects of noise intensity, damping coefficient, and time delay on SR are analyzed. The results show that the shapes of joint SPD can be adjusted to the desired structure by choosing the time delay and feedback gains. For fixed time delay, the SR peak is increased for negative displacement or velocity feedback gain. Meanwhile, the SR peak is decreased while the optimal noise intensity increases with increasing correlation time of noise. The Monte Carlo simulations(MCS) confirm the effectiveness of the theoretical results. 展开更多
关键词 stochastic resonance underdamped tri-stable system spectral amplification time-delayed feedback
下载PDF
Influence of exchange bias on spin torque ferromagnetic resonance for quantification of spin–orbit torque efficiency
12
作者 赵乾 张腾飞 +6 位作者 何斌 李子木 张森富 于国强 王建波 刘青芳 魏晋武 《Chinese Physics B》 SCIE EI CAS CSCD 2024年第5期688-694,共7页
Antiferromagnet(AFM)/ferromagnet(FM)heterostructure is a popular system for studying the spin–orbit torque(SOT)of AFMs.However,the interfacial exchange bias field induces that the magnetization in FM layer is noncoll... Antiferromagnet(AFM)/ferromagnet(FM)heterostructure is a popular system for studying the spin–orbit torque(SOT)of AFMs.However,the interfacial exchange bias field induces that the magnetization in FM layer is noncollinear to the external magnetic field,namely the magnetic moment drag effect,which further influences the characteristic of SOT efficiency.In this work,we study the SOT efficiencies of IrMn/NiFe bilayers with strong interfacial exchange bias by using spin-torque ferromagnetic resonance(ST-FMR)method.A full analysis on the AFM/FM systems with exchange bias is performed,and the angular dependence of magnetization on external magnetic field is determined through the minimum rule of free energy.The ST-FMR results can be well fitted by this model.We obtained the relative accurate SOT efficiencyξ_(DL)=0.058 for the IrMn film.This work provides a useful method to analyze the angular dependence of ST-FMR results and facilitates the accurate measurement of SOT efficiency for the AFM/FM heterostructures with strong exchange bias. 展开更多
关键词 ANTIFERROMAGNETS spin-orbit torque exchange bias spin torque ferromagnetic resonance
下载PDF
Generation of lossy mode resonances(LMR)using perovskite nanofilms
13
作者 Dayron Armas Ignacio R.Matias +4 位作者 M.Carmen Lopez-Gonzalez Carlos Ruiz Zamarreño Pablo Zubiate Ignacio del Villar Beatriz Romero 《Opto-Electronic Advances》 SCIE EI CAS CSCD 2024年第2期33-40,共8页
The results presented here show for the first time the experimental demonstration of the fabrication of lossy mode resonance(LMR) devices based on perovskite coatings deposited on planar waveguides. Perovskite thin fi... The results presented here show for the first time the experimental demonstration of the fabrication of lossy mode resonance(LMR) devices based on perovskite coatings deposited on planar waveguides. Perovskite thin films have been obtained by means of the spin coating technique and their presence was confirmed by ellipsometry, scanning electron microscopy, and X-ray diffraction testing. The LMRs can be generated in a wide wavelength range and the experimental results agree with the theoretical simulations. Overall, this study highlights the potential of perovskite thin films for the development of novel LMR-based devices that can be used for environmental monitoring, industrial sensing, and gas detection, among other applications. 展开更多
关键词 PEROVSKITE thin films slab waveguide lossy mode resonance
下载PDF
Preoperative prediction of perineural invasion of rectal cancer based on a magnetic resonance imaging radiomics model:A dual-center study
14
作者 Yan Liu Bai-Jin-Tao Sun +3 位作者 Chuan Zhang Bing Li Xiao-Xuan Yu Yong Du 《World Journal of Gastroenterology》 SCIE CAS 2024年第16期2233-2248,共16页
BACKGROUND Perineural invasion(PNI)has been used as an important pathological indicator and independent prognostic factor for patients with rectal cancer(RC).Preoperative prediction of PNI status is helpful for indivi... BACKGROUND Perineural invasion(PNI)has been used as an important pathological indicator and independent prognostic factor for patients with rectal cancer(RC).Preoperative prediction of PNI status is helpful for individualized treatment of RC.Recently,several radiomics studies have been used to predict the PNI status in RC,demonstrating a good predictive effect,but the results lacked generalizability.The preoperative prediction of PNI status is still challenging and needs further study.AIM To establish and validate an optimal radiomics model for predicting PNI status preoperatively in RC patients.METHODS This retrospective study enrolled 244 postoperative patients with pathologically confirmed RC from two independent centers.The patients underwent preoperative high-resolution magnetic resonance imaging(MRI)between May 2019 and August 2022.Quantitative radiomics features were extracted and selected from oblique axial T2-weighted imaging(T2WI)and contrast-enhanced T1WI(T1CE)sequences.The radiomics signatures were constructed using logistic regression analysis and the predictive potential of various sequences was compared(T2WI,T1CE and T2WI+T1CE fusion sequences).A clinical-radiomics(CR)model was established by combining the radiomics features and clinical risk factors.The internal and external validation groups were used to validate the proposed models.The area under the receiver operating characteristic curve(AUC),DeLong test,net reclassification improvement(NRI),integrated discrimination improvement(IDI),calibration curve,and decision curve analysis(DCA)were used to evaluate the model performance.RESULTS Among the radiomics models,the T2WI+T1CE fusion sequences model showed the best predictive performance,in the training and internal validation groups,the AUCs of the fusion sequence model were 0.839[95%confidence interval(CI):0.757-0.921]and 0.787(95%CI:0.650-0.923),which were higher than those of the T2WI and T1CE sequence models.The CR model constructed by combining clinical risk factors had the best predictive performance.In the training and internal and external validation groups,the AUCs of the CR model were 0.889(95%CI:0.824-0.954),0.889(95%CI:0.803-0.976)and 0.894(95%CI:0.814-0.974).Delong test,NRI,and IDI showed that the CR model had significant differences from other models(P<0.05).Calibration curves demonstrated good agreement,and DCA revealed significant benefits of the CR model.CONCLUSION The CR model based on preoperative MRI radiomics features and clinical risk factors can preoperatively predict the PNI status of RC noninvasively,which facilitates individualized treatment of RC patients. 展开更多
关键词 Rectal cancer Perineural invasion Magnetic resonance imaging Radiomics NOMOGRAM
下载PDF
Logical stochastic resonance in a cross-bifurcation non-smooth system
15
作者 张宇青 雷佑铭 《Chinese Physics B》 SCIE EI CAS CSCD 2024年第3期659-667,共9页
This paper investigates logical stochastic resonance(LSR)in a cross-bifurcation non-smooth system driven by Gaussian colored noise.In this system,a bifurcation parameter triggers a transition between monostability,bis... This paper investigates logical stochastic resonance(LSR)in a cross-bifurcation non-smooth system driven by Gaussian colored noise.In this system,a bifurcation parameter triggers a transition between monostability,bistability and tristability.By using Novikov's theorem and the unified colored noise approximation method,the approximate Fokker-Planck equation is obtained.Then we derive the generalized potential function and the transition rates to analyze the LSR phenomenon using numerical simulations.We simulate the logic operation of the system in the bistable and tristable regions respectively.We assess the impact of Gaussian colored noise on the LSR and discover that the reliability of the logic response depends on the noise strength and the bifurcation parameter.Furthermore,it is found that the bistable region has a more extensive parameter range to produce reliable logic operation compared with the tristable region,since the tristable region is more sensitive to noise than the bistable one. 展开更多
关键词 logical stochastic resonance BIFURCATION mean first passage time
下载PDF
Ion heat transport in electron cyclotron resonance heated L-mode plasma on the T-10 tokamak
16
作者 V.A.KRUPIN M.R.NURGALIEV +9 位作者 A.R.NEMETS I.A.ZEMTSOV S.D.SUNTSOV T.B.MYALTON D.S.SERGEEV N.A.SOLOVEV D.V.SARYCHEV D.V.RYJAKOV S.N.TUGARINOV N.N.NAUMENKO 《Plasma Science and Technology》 SCIE EI CAS CSCD 2024年第4期52-60,共9页
Anomalous ion heat transport is analyzed in the T-10 tokamak plasma heated with electron cyclotron resonance heating(ECRH) in second-harmonic extra-ordinary mode. Predictive modeling with empirical scaling for Ohmical... Anomalous ion heat transport is analyzed in the T-10 tokamak plasma heated with electron cyclotron resonance heating(ECRH) in second-harmonic extra-ordinary mode. Predictive modeling with empirical scaling for Ohmical heat conductivity shows that in ECRH plasmas the calculated ion temperature could be overestimated, so an increase of anomalous ion heat transport is required. To study this effect two scans are presented: over the EC resonance position and over the ECRH power. The EC resonance position varies from the high-field side to the low-field side by variation of the toroidal magnetic field. The scan over the heating power is presented with on-axis and mixed ECRH regimes. Discharges with high anomalous ion heat transport are obtained in all considered regimes. In these discharges the power balance ion heat conductivity exceeds the neoclassical level by up to 10 times. The high ion heat transport regimes are distinguished by three parameters: the ratio Te/Ti, the normalized electron density gradient R/■, and the ion–ion collisionality νii~*. The combination of high Te/Ti, high νii~*, and R/■=6-10 results in values of normalized anomalous ion heat fluxes up to 10 times higher than in the low transport scenario. 展开更多
关键词 TOKAMAK L-mode electron cyclotron resonance heating ion heat transport
下载PDF
Structure and ion transport properties of organic ionic compounds revealed by NMR
17
作者 Haijin Zhu 《Magnetic Resonance Letters》 2024年第2期2-12,共11页
Organic ionic plastic crystals(OIPCs)are emerging as an important material family for solid-state electrolytes and many other applications.They have significant advantages over conventional electrolyte materials,such ... Organic ionic plastic crystals(OIPCs)are emerging as an important material family for solid-state electrolytes and many other applications.They have significant advantages over conventional electrolyte materials,such as high ionic conductivity,non-flammability,and plasticity.Various nuclear magnetic resonance(NMR)spectroscopy techniques including solid-state NMR,pulsed-field gradient(PFG)NMR,and magnetic resonance imaging(MRI)etc.,provide us a versatile toolkit to understand the fundamental level structures,molecular dynamics,and ionic interactions in these materials.This article reviews the commonly used NMR methods including solid-and solution-state NMR,PFG-NMR,dynamic nuclear polarization(DNP)and the application of these methods in revealing the microscopic level structures and ion-transport mechanisms in OIPC materials. 展开更多
关键词 nmr ELECTROLYTE Organic ionic plastic crystals DEFECTS Diffusion Microstructure
下载PDF
Simplified liver imaging reporting and data system for the diagnosis of hepatocellular carcinoma on gadoxetic acid-enhanced magnetic resonance imaging
18
作者 Rong Lyu Wei-Juan Hu +3 位作者 Di Wang Jiao Wang Yu-Bing Ye Ke-Feng Jia 《World Journal of Gastrointestinal Oncology》 SCIE 2024年第6期2439-2448,共10页
BACKGROUND The liver imaging reporting and data system(LI-RADS)diagnostic table has 15 cells and is too complex.The diagnostic performance of LI-RADS for hepatocellular carcinoma(HCC)is not satisfactory on gadoxetic a... BACKGROUND The liver imaging reporting and data system(LI-RADS)diagnostic table has 15 cells and is too complex.The diagnostic performance of LI-RADS for hepatocellular carcinoma(HCC)is not satisfactory on gadoxetic acid-enhanced magnetic resonance imaging(EOB-MRI).AIM To evaluate the ability of the simplified LI-RADS(sLI-RADS)to diagnose HCC on EOB-MRI.METHODS A total of 331 patients with 356 hepatic observations were retrospectively analysed.The diagnostic performance of sLI-RADS A-D using a single threshold was evaluated and compared with LI-RADS v2018 to determine the optimal sLIRADS.The algorithms of sLI-RADS A-D are as follows:The single threshold for sLI-RADS A and B was 10 mm,that is,classified observations≥10mm using an algorithm of 10-19 mm observations(sLI-RADS A)and≥20 mm observations(sLI-RADS B)in the diagnosis table of LI-RADS v2018,respectively,while the classification algorithm remained unchanged for observations<10 mm;the single threshold for sLI-RADS C and D was 20 mm,that is,for<20 mm observations,the algorithms for<10 mm observations(sLI-RADS C)and 10-19 mm observations(sLI-RADS D)were used,respectively,while the algorithm remained unchanged for observations≥20 mm.With hepatobiliary phase(HBP)hypointensity as a major feature(MF),the final sLI-RADS(F-sLI-RADS)was formed according to the optimal sLI-RADS,and its diagnostic performance was evaluated.The times needed to classify the observations according to F-sLIRADS and LI-RADS v2018 were compared.RESULTS The optimal sLI-RADS was sLI-RADS D(with a single threshold of 20 mm),because its sensitivity was greater than that of LI-RADS v2018(89.8%vs 87.0%,P=0.031),and its specificity was not lower(89.4%vs 90.1%,P>0.999).With HBP hypointensity as an MF,the sensitivity of F-sLI-RADS was greater than that of LI-RADS v2018(93.0%vs 87.0%,P<0.001)and sLI-RADS D(93.0%vs 89.8%,P=0.016),without a lower specificity(86.5%vs 90.1%,P=0.062;86.5%vs 89.4%,P=0.125).Compared with that of LI-RADS v2018,the time to classify lesions according to FsLI-RADS was shorter(51±21 s vs 73±24 s,P<0.001).CONCLUSION The use of sLI-RADS with HBP hypointensity as an MF may improve the sensitivity of HCC diagnosis and reduce lesion classification time. 展开更多
关键词 Hepatocellular carcinoma Magnetic resonance imaging LIVER DIAGNOSIS Contrast agent
下载PDF
Current status of magnetic resonance imaging radiomics in hepatocellular carcinoma:A quantitative review with Radiomics Quality Score
19
作者 Valentina Brancato Marco Cerrone +2 位作者 Nunzia Garbino Marco Salvatore Carlo Cavaliere 《World Journal of Gastroenterology》 SCIE CAS 2024年第4期381-417,共37页
BACKGROUND Radiomics is a promising tool that may increase the value of magnetic resonance imaging(MRI)for different tasks related to the management of patients with hepatocellular carcinoma(HCC).However,its implement... BACKGROUND Radiomics is a promising tool that may increase the value of magnetic resonance imaging(MRI)for different tasks related to the management of patients with hepatocellular carcinoma(HCC).However,its implementation in clinical practice is still far,with many issues related to the methodological quality of radiomic studies.AIM To systematically review the current status of MRI radiomic studies concerning HCC using the Radiomics Quality Score(RQS).METHODS A systematic literature search of PubMed,Google Scholar,and Web of Science databases was performed to identify original articles focusing on the use of MRI radiomics for HCC management published between 2017 and 2023.The methodological quality of radiomic studies was assessed using the RQS tool.Spearman’s correlation(ρ)analysis was performed to explore if RQS was correlated with journal metrics and characteristics of the studies.The level of statistical significance was set at P<0.05.RESULTS One hundred and twenty-seven articles were included,of which 43 focused on HCC prognosis,39 on prediction of pathological findings,16 on prediction of the expression of molecular markers outcomes,18 had a diagnostic purpose,and 11 had multiple purposes.The mean RQS was 8±6.22,and the corresponding percentage was 24.15%±15.25%(ranging from 0.0% to 58.33%).RQS was positively correlated with journal impact factor(IF;ρ=0.36,P=2.98×10^(-5)),5-years IF(ρ=0.33,P=1.56×10^(-4)),number of patients included in the study(ρ=0.51,P<9.37×10^(-10))and number of radiomics features extracted in the study(ρ=0.59,P<4.59×10^(-13)),and time of publication(ρ=-0.23,P<0.0072).CONCLUSION Although MRI radiomics in HCC represents a promising tool to develop adequate personalized treatment as a noninvasive approach in HCC patients,our study revealed that studies in this field still lack the quality required to allow its introduction into clinical practice. 展开更多
关键词 Hepatocellular carcinoma Systematic review Magnetic resonance imaging Radiomics Radiomics quality score
下载PDF
Magnetic resonance imaging-based lymph node radiomics for predicting the metastasis of evaluable lymph nodes in rectal cancer
20
作者 Yong-Xia Ye Liu Yang +6 位作者 Zheng Kang Mei-Qin Wang Xiao-Dong Xie Ke-Xin Lou Jun Bao Mei Du Zhe-Xuan Li 《World Journal of Gastrointestinal Oncology》 SCIE 2024年第5期1849-1860,共12页
BACKGROUND Lymph node(LN)staging in rectal cancer(RC)affects treatment decisions and patient prognosis.For radiologists,the traditional preoperative assessment of LN metastasis(LNM)using magnetic resonance imaging(MRI... BACKGROUND Lymph node(LN)staging in rectal cancer(RC)affects treatment decisions and patient prognosis.For radiologists,the traditional preoperative assessment of LN metastasis(LNM)using magnetic resonance imaging(MRI)poses a challenge.AIM To explore the value of a nomogram model that combines Conventional MRI and radiomics features from the LNs of RC in assessing the preoperative metastasis of evaluable LNs.METHODS In this retrospective study,270 LNs(158 nonmetastatic,112 metastatic)were randomly split into training(n=189)and validation sets(n=81).LNs were classified based on pathology-MRI matching.Conventional MRI features[size,shape,margin,T2-weighted imaging(T2WI)appearance,and CE-T1-weighted imaging(T1WI)enhancement]were evaluated.Three radiomics models used 3D features from T1WI and T2WI images.Additionally,a nomogram model combining conventional MRI and radiomics features was developed.The model used univariate analysis and multivariable logistic regression.Evaluation employed the receiver operating characteristic curve,with DeLong test for comparing diagnostic performance.Nomogram performance was assessed using calibration and decision curve analysis.RESULTS The nomogram model outperformed conventional MRI and single radiomics models in evaluating LNM.In the training set,the nomogram model achieved an area under the curve(AUC)of 0.92,which was significantly higher than the AUCs of 0.82(P<0.001)and 0.89(P<0.001)of the conventional MRI and radiomics models,respectively.In the validation set,the nomogram model achieved an AUC of 0.91,significantly surpassing 0.80(P<0.001)and 0.86(P<0.001),respectively.CONCLUSION The nomogram model showed the best performance in predicting metastasis of evaluable LNs. 展开更多
关键词 Radiomics Lymph node metastasis Rectal cancer Magnetic resonance imaging
下载PDF
上一页 1 2 250 下一页 到第
使用帮助 返回顶部