The sequence analysis of peptides was performed by nano-electrospray ionization Fourier transform ion cyclotron resonance tandem mass spectrometry(Nano-ESI-FT-ICR-MSn) and several peptides were chosen as examples. W...The sequence analysis of peptides was performed by nano-electrospray ionization Fourier transform ion cyclotron resonance tandem mass spectrometry(Nano-ESI-FT-ICR-MSn) and several peptides were chosen as examples. With the aid of the collision induced dissociation(CID), FT-ICR provides not only precise mass/charge ratio, but also structure information of the selected peptides. The fragment ions were identified according to the observed molecular weights and peptide sequence was determined successfully. So Nano-ESI-FT-ICR-MSn is a useful tool for identification of the amino acid sequence of peptides with high confidence. Besides, a pathway for the dehydration of y ions without amino acids containing carboxylic acid under sustained off-resonance irradiation collision-induced dissociation(SORI-CID) condition was proposed.展开更多
A highly accurate and precise technique for measurement of the 93 Nb(n,n’)93m Nb reaction rate was established for the material surveillance tests,etc.in fast reactors.The self-absorption effect on the measurement of...A highly accurate and precise technique for measurement of the 93 Nb(n,n’)93m Nb reaction rate was established for the material surveillance tests,etc.in fast reactors.The self-absorption effect on the measurement of the characteristic X-rays emitted by 93m Nb was decreased by the dissolution and evaporation to dryness of niobium dosimeter.A highly precise count of the number of 93 Nb atoms was obtained by measuring the niobium solution concentration using inductively coupled plasma mass spectrometry.X-rays of 93m Nb were measured accurately by means of comparing the X-ray intensity of irradiated niobium solution with that of the solution in which stable 93 Nb was added.The difference between both intensities indicates the effect of 182 Ta,which is generated from an impurity tantalum,and the intensity of X-rays from 93m Nb was evaluated.Measurement error of the 93 Nb(n,n’)93m Nb reaction rate was reduced to be less than 4%,which was equivalent to the other reaction rate errors of dosimeters used for Joyo dosimetry.In addition,an advanced technique using Resonance Ionization Mass Spectrometry was proposed for the precise measurement of 93m Nb yield,and 93m Nb will be resonance-ionized selectively by discriminating the hyperfine splitting of the atomic energy levels between 93 Nb and 93m Nb at high resolution.展开更多
基金Supported by the National Natural Science Foundation of China(No.20675079)
文摘The sequence analysis of peptides was performed by nano-electrospray ionization Fourier transform ion cyclotron resonance tandem mass spectrometry(Nano-ESI-FT-ICR-MSn) and several peptides were chosen as examples. With the aid of the collision induced dissociation(CID), FT-ICR provides not only precise mass/charge ratio, but also structure information of the selected peptides. The fragment ions were identified according to the observed molecular weights and peptide sequence was determined successfully. So Nano-ESI-FT-ICR-MSn is a useful tool for identification of the amino acid sequence of peptides with high confidence. Besides, a pathway for the dehydration of y ions without amino acids containing carboxylic acid under sustained off-resonance irradiation collision-induced dissociation(SORI-CID) condition was proposed.
文摘A highly accurate and precise technique for measurement of the 93 Nb(n,n’)93m Nb reaction rate was established for the material surveillance tests,etc.in fast reactors.The self-absorption effect on the measurement of the characteristic X-rays emitted by 93m Nb was decreased by the dissolution and evaporation to dryness of niobium dosimeter.A highly precise count of the number of 93 Nb atoms was obtained by measuring the niobium solution concentration using inductively coupled plasma mass spectrometry.X-rays of 93m Nb were measured accurately by means of comparing the X-ray intensity of irradiated niobium solution with that of the solution in which stable 93 Nb was added.The difference between both intensities indicates the effect of 182 Ta,which is generated from an impurity tantalum,and the intensity of X-rays from 93m Nb was evaluated.Measurement error of the 93 Nb(n,n’)93m Nb reaction rate was reduced to be less than 4%,which was equivalent to the other reaction rate errors of dosimeters used for Joyo dosimetry.In addition,an advanced technique using Resonance Ionization Mass Spectrometry was proposed for the precise measurement of 93m Nb yield,and 93m Nb will be resonance-ionized selectively by discriminating the hyperfine splitting of the atomic energy levels between 93 Nb and 93m Nb at high resolution.