期刊文献+
共找到29篇文章
< 1 2 >
每页显示 20 50 100
Enhanced resonance frequency in Co2FeAl thin film with different thicknesses grown on flexible graphene substrate
1
作者 周偲 袁少康 +8 位作者 朱登玉 白宇明 王韬 刘福福 潘禄禄 冯存芳 张博涵 何大平 汪胜祥 《Chinese Physics B》 SCIE EI CAS CSCD 2024年第3期618-622,共5页
The flexible materials exhibit more favorable properties than most rigid substrates in flexibility,weight saving,mechanical reliability,and excellent environmental toughness.Particularly,flexible graphene film with un... The flexible materials exhibit more favorable properties than most rigid substrates in flexibility,weight saving,mechanical reliability,and excellent environmental toughness.Particularly,flexible graphene film with unique mechanical properties was extensively explored in high frequency devices.Herein,we report the characteristics of structure and magnetic properties at high frequency of Co2FeAl thin film with different thicknesses grown on flexible graphene substrate at room temperature.The exciting finding for the columnar structure of Co2FeAl thin film lays the foundation for excellent high frequency property of Co2FeAl/flexible graphene structure.In-plane magnetic anisotropy field varying with increasing thickness of Co2FeAl thin film can be obtained by measurement of ferromagnetic resonance,which can be ascribed to the enhancement of crystallinity and the increase of grain size.Meanwhile,the resonance frequency which can be achieved by the measurement of vector network analyzer with the microstrip method increases with increasing thickness of Co2FeAl thin film.Moreover,in our case with graphene film,the resonance magnetic field is quite stable though folded for twenty cycles,which demonstrates that good flexibility of graphene film and the stability of high frequency magnetic property of Co2FeAl thin film grown on flexible graphene substrate.These results are promising for the design of microwave devices and wireless communication equipment. 展开更多
关键词 enhanced resonance frequency magnetic resonance field flexible graphene substrate
下载PDF
Pre-operative enhanced magnetic resonance imaging combined with clinical features predict early recurrence of hepatocellular carcinoma after radical resection
2
作者 Jian-Ping Chen Ri-Hui Yang +3 位作者 Tian-Hui Zhang Li-An Liao Yu-Ting Guan Hai-Yang Dai 《World Journal of Gastrointestinal Oncology》 SCIE 2024年第4期1192-1203,共12页
BACKGROUND Indentifying predictive factors for postoperative recurrence of hepatocellular carcinoma(HCC)has great significance for patient prognosis.AIM To explore the value of gadolinium ethoxybenzyl diethylenetriami... BACKGROUND Indentifying predictive factors for postoperative recurrence of hepatocellular carcinoma(HCC)has great significance for patient prognosis.AIM To explore the value of gadolinium ethoxybenzyl diethylenetriamine pentaacetic acid(Gd-EOB-DTPA)enhanced magnetic resonance imaging(MRI)combined with clinical features in predicting early recurrence of HCC after resection.METHODS A total of 161 patients with pathologically confirmed HCC were enrolled.The patients were divided into early recurrence and non-early recurrence group based on the follow-up results.The clinical,laboratory,pathological results and Gd-EOB-DTPA enhanced MRI imaging features were analyzed.RESULTS Of 161 patients,73 had early recurrence and 88 were had non-early recurrence.Univariate analysis showed that patient age,gender,serum alpha-fetoprotein level,the Barcelona Clinic Liver Cancer stage,China liver cancer(CNLC)stage,microvascular invasion(MVI),pathological satellite focus,tumor size,tumor number,tumor boundary,tumor capsule,intratumoral necrosis,portal vein tumor thrombus,large vessel invasion,nonperipheral washout,peritumoral enhancement,hepatobiliary phase(HBP)/tumor signal intensity(SI)/peritumoral SI,HBP peritumoral low signal and peritumoral delay enhancement were significantly associated with early recurrence of HCC after operation.Multivariate logistic regression analysis showed that patient age,MVI,CNLC stage,tumor boundary and large vessel invasion were independent predictive factors.External data validation indicated that the area under the curve of the combined predictors was 0.861,suggesting that multivariate logistic regression was a reasonable predictive model for early recurrence of HCC.CONCLUSION Gd-EOB-DTPA enhanced MRI combined with clinical features would help predicting the early recurrence of HCC after operation. 展开更多
关键词 Hepatocellular carcinoma enhanced magnetic resonance imaging Microvascular invasion Hepatobiliary phase RECURRENCE
下载PDF
Resonant cavity-enhanced quantum dot field-effect transistor as a single-photon detector
3
作者 董宇 王广龙 +6 位作者 王红培 倪海桥 陈建辉 高凤岐 乔中涛 杨晓红 牛智川 《Chinese Physics B》 SCIE EI CAS CSCD 2014年第10期162-167,共6页
A resonant cavity-enhanced (RCE) quantum dot (QD) field-effect transistor (RCEQDFET) is designed for single- photon detection in this paper. Adding distributed Bragg reflection (DBR) mirrors to the single-phot... A resonant cavity-enhanced (RCE) quantum dot (QD) field-effect transistor (RCEQDFET) is designed for single- photon detection in this paper. Adding distributed Bragg reflection (DBR) mirrors to the single-photon detector (SPD), we improve the light absorption efficiency of the SPD. The effects of the reflectivity of the mirrors, the thickness and light absorption coefficient of the absorbing layer on the detector's light absorption efficiency are investigated, and the resonant cavity is determined by using the air/semiconductor interface as the mirror on the top. Through analyzing the relationship between the refractive index of AlxGal_xAs and A1 component, we choose A1As/Alo.15Gao.85As as the material of the mirror on the bottom. The pairs of A1As/Alo.15Gao.85As film are further determined to be 21 by calculating the reflectivity of the mirror. The detector is fabricated from semiconductor heterostructures grown by molecular beam epitaxy. The reflection spectrum, photoluminescence (PL) spectrum, photocurrent response, and channel current of the detector are tested and the results show that the RCEQDFET-SPD designed in this paper has better performances in photonic response and wavelength selection. 展开更多
关键词 single-photon detector quantum dot field-effect transistor resonant cavity enhanced
下载PDF
Resonant perfect absorption of molybdenum disulfide beyond the bandgap
4
作者 于昊 谢颖 +3 位作者 魏佳辉 张培晴 崔志英 于浩海 《Chinese Physics B》 SCIE EI CAS CSCD 2023年第4期670-676,共7页
Light absorption and radiation are fundamental processes in optical science and engineering.Materials with perfect absorption properties play an important role in numerous optical applications.Following the meteoric r... Light absorption and radiation are fundamental processes in optical science and engineering.Materials with perfect absorption properties play an important role in numerous optical applications.Following the meteoric rise of MoS_(2)material,global opportunities and challenges coexist due to its extremely weak light-matter interaction capability beyond its energy band.In this work,we designed a kind of sandwich resonance structure and investigated MoS_(2)as a perfect absorber in the infrared spectrum that should be transparent according to the optical band theory.The infrared absorption properties of W or Au/MoS_(2)/Au models at 800 nm-2400 nm were systematic simulated.By optimizing the structural parameters,the resonant wavelength of perfect absorption can be modulated from 830 nm to 1700 nm with angle insensitivity and polar independence.Moreover,we discovered that the bandwidth of absorption exceeding 50%of the W-top model reaches500 nm,while that of the Au-top model is less than 100 nm,indicating that the top metal material has a great influence on the resonance absorption spectrum.Our work provides a practical route for enhancing and manipulating the light-matter interactions of low-dimensional materials beyond their own band gaps,which will be critical in the future design and implementation of optoelectronic devices and systems. 展开更多
关键词 multilayer MoS_(2) Fabry-Perot structure infrared absorption resonance enhancement
下载PDF
Application of contrast-enhanced intraoperative ultrasonography in the decision-making about hepatocellular carcinoma operation 被引量:22
5
作者 Wu, Hong Lu, Qiang +2 位作者 Luo, Yan He, Xian-Lu Zeng, Yong 《World Journal of Gastroenterology》 SCIE CAS CSCD 2010年第4期508-512,共5页
AIM:To evaluate the detection and differentiation ability of contrast-enhanced intraoperative ultrasonography(CE-IOUS) in hepatocellular carcinoma(HCC) operations.METHODS:Clinical data of 50 HCC patients were retrospe... AIM:To evaluate the detection and differentiation ability of contrast-enhanced intraoperative ultrasonography(CE-IOUS) in hepatocellular carcinoma(HCC) operations.METHODS:Clinical data of 50 HCC patients were retrospective analyzed.The sensitivity,specificity,false negative and false positive rates of contrast enhanced magnetic resonance imaging(CE-MRI),IOUS and CEIOUS were calculated and compared.Surgical strategy changes due to CE-IOUS were analyzed.RESULTS:Lesions detected by CE-MRI,IOUS and CEIOUS were 60,97 and 85 respectively.The sensitivity,specificity,false negative rate,false positive rate of CEMRI were 98.2%,98.6%,98.6%,60.0%,respectively;for IOUS were 50.0%,90.9%,1.8%,1.4%,respectively;and for CE-IOUS were 1.4%,40.0%,50.0%,9.1%,respectively.The operation strategy of 9(9/50,18.0%) cases was changed according to the results of CE-IOUS.CONCLUSION:Compared with CE-MRI,CE-IOUS performs better in detection and differentiation of small metastasis and regenerative nodules.It plays an important role in the decision-making of HCC operation. 展开更多
关键词 Hepatocellular carcinoma Liver resection Contrast enhanced magnetic resonance imaging Intraoperative ultrasonography Contrast-enhanced intraoperative ultrasonography
下载PDF
Three-Tesla magnetic resonance elastography for hepatic fibrosis:Comparison with diffusion-weighted imaging and gadoxetic acid-enhanced magnetic resonance imaging 被引量:9
6
作者 Hee Sun Park Young Jun Kim +3 位作者 Mi Hye Yu Won Hyeok Choe Sung Il Jung Hae Jeong Jeon 《World Journal of Gastroenterology》 SCIE CAS 2014年第46期17558-17567,共10页
AIM: To evaluate the feasibility of 3-Tesla magnetic resonance elastography (MRE) for hepatic fibrosis and to compare that with diffusion-weighted imaging (DWI) and gadoxetic acid-enhanced magnetic resonance (MR) imag... AIM: To evaluate the feasibility of 3-Tesla magnetic resonance elastography (MRE) for hepatic fibrosis and to compare that with diffusion-weighted imaging (DWI) and gadoxetic acid-enhanced magnetic resonance (MR) imaging. 展开更多
关键词 Magnetic resonance elastography Hepatic fibrosis Diffusion weighted imaging Gadoxetic acid enhanced magnetic resonance imaging Serum markers
下载PDF
Selective excitation of molecular mode in a mixture by femtosecond resonance-enhanced coherent anti-Stokes Raman scattering spectroscopy 被引量:2
7
作者 He Ping Li Si-Ning +4 位作者 Fan Rong-Wei Li Xiao-Hui Xia Yuan-Qin Yu Xin Chen De-Ying 《Chinese Physics B》 SCIE EI CAS CSCD 2012年第2期526-530,共5页
Femtosecond time-resolved coherent anti-Stokes Raman scattering (CARS) spectroscopy is used to investigate gaseous molecular dynamics. Due to the spectrally broad laser pulses, usually poorly resolved spectra result... Femtosecond time-resolved coherent anti-Stokes Raman scattering (CARS) spectroscopy is used to investigate gaseous molecular dynamics. Due to the spectrally broad laser pulses, usually poorly resolved spectra result from this broad spectroscopy. However, it can be demonstrated that by the electronic resonance enhancement optimization control a selective excitation of specific vibrational mode is possible. Using an electronically resonance-enhanced effect, iodine molecule specific CARS spectroscopy can be obtained from a mixture of iodine-air at room temperature and a pressure of 1 atm (corresponding to a saturation iodine vapour as low as about 35 Pa). The dynamics on either the electronically excited state or the ground state of iodine molecules obtained is consistent with previous studies (vacuum, heated and pure iodine) in the femtoseeond time resolved CARS spectroscopy, showing that an effective method of suppressing the non-resonant CARS background and other interferences is demonstrated. 展开更多
关键词 ultrafast spectroscopy coherent anti-Stokes Raman scattering vibrational analysis resonance enhancement
下载PDF
Mammography combined with breast dynamic contrast-enhanced-magnetic resonance imaging for the diagnosis of early breast cancer 被引量:4
8
作者 Yakun He Guohui Xu +4 位作者 Jin Ren Bin Feng Xiaolei Dong Hao Lu Changjiu He 《Oncology and Translational Medicine》 2016年第4期165-168,共4页
Objective The aim of this study was to investigate the application of mammography combined with breast dynamic contrast-enhanced magnetic resonance imaging(DCE-MRI) for the diagnosis of early breast cancer. Methods Ma... Objective The aim of this study was to investigate the application of mammography combined with breast dynamic contrast-enhanced magnetic resonance imaging(DCE-MRI) for the diagnosis of early breast cancer. Methods Mammography and DCE-MRI were performed for 120 patients with breast cancer(malignant, 102; benign; 18). Results The sensitivity of mammography for early diagnosis of breast cancer was 66.67%, specificity was 77.78%, and accuracy was 68.33%. The sensitivity of MRI for early diagnosis of breast cancer was 94.12%, specificity was 88.89%, and accuracy was 93.33%. However, the sensitivity of mammography combined with DCE-MRI volume imaging with enhanced water signal(VIEWS) scanning for early diagnosis of breast cancer was 97.06%, specificity was 94.44%, and accuracy was 96.67%. Conclusion Mammography combined with DCE-MRI increased the sensitivity, specificity, and accuracy of diagnosing early breast cancer. 展开更多
关键词 breast carcinoma mammography nuclear magnetic resonance dynamic enhancement time signal curve
下载PDF
Charge Resonance Enhanced Multiple Ionization of H2O Molecules in Intense Laser Fields
9
作者 刘鸿 黎敏 +5 位作者 解西国 吴聪 邓勇开 吴成印 龚旗煌 刘运全 《Chinese Physics Letters》 SCIE CAS CSCD 2015年第6期43-47,共5页
We perform a kinetically complete measurement on the fragmentation of Coulomb explosion of 1-120 molecules in intense few-cycle linearly and circularly polarized laser fields. Both the fragmentations of 1t203+ and H... We perform a kinetically complete measurement on the fragmentation of Coulomb explosion of 1-120 molecules in intense few-cycle linearly and circularly polarized laser fields. Both the fragmentations of 1t203+ and H204+ reveal the concerted pathway of dissociation. The length of the OH bond prior to the Coulomb explosion of both molecular ions is sensitive to the laser pulse duration and laser intensity. However, the bending angle of H-O-H is less sensitive to the pulse duration and laser intensity. We introduce the mechanism of charge resonance enhanced double ionization to elucidate the triple (or quadruple) dissociative ionization dynamics of H20, in which two electrons are non-adiabatically localized at the protons of the precursor ion H2O^+ (or H2O^2+) and are released simultaneously due to the over barrier ionization in the combined laser field and molecular ionic potential. Such charge resonance enhanced multiple ionization is not suppressed in few-cycle laser fields and elliptically polarized laser fields. 展开更多
关键词 In LENGTH Charge Resonance enhanced Multiple Ionization of H2O Molecules in Intense Laser Fields
下载PDF
Fully Automatic Scar Segmentation for Late Gadolinium Enhancement MRI Images in Left Ventricle with Myocardial Infarction
10
作者 Zheng-hong WU Li-ping SUN +8 位作者 Yun-long LIU Dian-dian DONG Lv TONG Dong-dong DENG Yi HE Hui WANG Yi-bo SUN Jian-zeng DONG Ling XIA 《Current Medical Science》 SCIE CAS 2021年第2期398-404,共7页
Numerous methods have been published to segment the infarct tissue in theleft ventricle, most of them either need manual work, post-processing, or suffer from poorreproducibility. We proposed an automatic segmentation... Numerous methods have been published to segment the infarct tissue in theleft ventricle, most of them either need manual work, post-processing, or suffer from poorreproducibility. We proposed an automatic segmentation method for segmenting the infarct tissue irleft ventricle with myocardial infarction. Cardiac images of a total of 60 diseased hearts (55 humanhearts and 5 porcine hearts) were used in this study. The epicardial and endocardial boundariesof the ventricles in every 2D slice of the cardiac magnetic resonance with late gadoliniumenhancement images were manually segmented. The subsequent pipeline of infarct tissuesegmentation is fully automatic. The segmentation results with the automatic algorithm proposed inthis paper were compared to the consensus ground truth. The median of Dice overlap between ourautomatic method and the consensus ground truth is 0.79. We also compared the automatic methodwith the consensus ground truth using different image sources from diferent centers with diferentscan parameters and different scan machines. The results showed that the Dice overlap with thepublic dataset was 0.83, and the overall Dice overlap was 0.79. The results show that our method isrobust with respect to different MRI image sources, which were scanned by different centers withdifferent image collection parameters. The segmentation accuracy we obtained is comparable toor better than that of the conventional semi-automatic methods. Our segmentation method may beuseful for processing large amount of dataset in clinic. 展开更多
关键词 myocardial infarction cardiac magnetic resonance with late gadolinium enhancement automatic scar segmentation
下载PDF
Interplay between out-of-plane magnetic plasmon and lattice resonance for modified resonance lineshape and near-field enhancement in double nanoparticles array
11
作者 丁佩 王俊俏 +3 位作者 何金娜 范春珍 蔡根旺 梁二军 《Chinese Physics B》 SCIE EI CAS CSCD 2013年第12期472-477,共6页
Two-dimensional double nanoparticle (DNP) arrays are demonstrated theoretically, supporting the interaction between out-of-plane magnetic plasmons and in-plane lattice resonances, which can be achieved by tuning the... Two-dimensional double nanoparticle (DNP) arrays are demonstrated theoretically, supporting the interaction between out-of-plane magnetic plasmons and in-plane lattice resonances, which can be achieved by tuning the nanoparticle height or the array period due to the height-dependent magnetic resonance and the periodicity-dependent lattice resonance. The interplay between the two plasmon modes can lead to a remarkable change in resonance lineshape and an improvement on magnetic field enhancement. Simultaneous electric field and magnetic field enhancement can be obtained in the gap region between neighboring particles at two resonance frequencies as the interplay occurs, which presents “open” cavities as electromagnetic field hot spots for potential applications on detection and sensing. The results not only offer an attractive way to tune the optical responses of plasmonic nanostructure, but also provide further insight into the plasmon interactions in periodic nanostructure or metamaterials comprising multiple elements. 展开更多
关键词 magnetic plasmon lattice resonance field enhancement nanoparticles array
下载PDF
Role of pulmonary perfusion magnetic resonance imaging for the diagnosis of pulmonary hypertension:A review
12
作者 Miriam Lacharie Adriana Villa +3 位作者 Xenios Milidonis Hadeer Hasaneen Amedeo Chiribiri Giulia Benedetti 《World Journal of Radiology》 2023年第9期256-273,共18页
Among five types of pulmonary hypertension,chronic thromboembolic pulmonary hypertension(CTEPH)is the only curable form,but prompt and accurate diagnosis can be challenging.Computed tomography and nuclear medicine-bas... Among five types of pulmonary hypertension,chronic thromboembolic pulmonary hypertension(CTEPH)is the only curable form,but prompt and accurate diagnosis can be challenging.Computed tomography and nuclear medicine-based techniques are standard imaging modalities to non-invasively diagnose CTEPH,however these are limited by radiation exposure,subjective qualitative bias,and lack of cardiac functional assessment.This review aims to assess the methodology,diagnostic accuracy of pulmonary perfusion imaging in the current literature and discuss its advantages,limitations and future research scope. 展开更多
关键词 Pulmonary perfusion MRI Pulmonary hypertension Dynamic contrast enhanced magnetic resonance imaging Chronic thromboembolic pulmonary hypertension Computed tomography pulmonary angiography Chronic thromboembolic disease
下载PDF
Array for 980nm Vertical Cavity Surface Emitting Diodes and Detectors
13
作者 梁琨 陈弘达 +3 位作者 杜云 唐君 杨晓红 吴荣汉 《Journal of Semiconductors》 EI CAS CSCD 北大核心 2002年第11期1135-1139,共5页
Both the vertical cavity surface emitting diodes and detectors are fabricated by using the epitaxial wafer with resonant cavity structure.Their characteristics are analyzed.The light emitters have high spectral purity... Both the vertical cavity surface emitting diodes and detectors are fabricated by using the epitaxial wafer with resonant cavity structure.Their characteristics are analyzed.The light emitters have high spectral purity of 4 8nm and high electroluminescence intensity of 0 7mW while injection current is 50mA.A 1×16 array of surface emitting light device is tested on line by probes and then used for module.The light detectors have wavelength selectivity and space selectivity.The required difference in input mirror reflectivity between emitters and detectors can easily be achieved though varying the numbers of top DBR period by etching. 展开更多
关键词 optical interconnects resonant cavity enhanced phtotonic devices monolithic integration
下载PDF
Diagnostic Value of Quantitative Parameters of DCE-MRI in Endometrial Carcinoma and Its Correlation with Clinicopathological Factors 被引量:1
14
作者 Xinyi Fang 《Advances in Modern Oncology Research》 2020年第2期15-20,共6页
In the study,108 patients with endometrial cancer were selected as the observation group,and 105 patients with benign endometrial lesions were selected as the control group.After DCE-MRI examination,it was found that ... In the study,108 patients with endometrial cancer were selected as the observation group,and 105 patients with benign endometrial lesions were selected as the control group.After DCE-MRI examination,it was found that the volume transfer constant(K^(trans)),rate constant(K_(e))and extracellular space volume ratio(V_(e))in the observation group were higher than those in the control group(P<0.05).The area under curve(AUC)of combined K^(trans),K_(e) and V_(e) values in the diagnosis of endometrial cancer was 0.841.The values of K^(trans),K_(e )and V_(e) were positively correlated with the clinical stage and the degree of muscular invasion,but negatively correlated with the degree of differentiation(P<0.05).The results of the study suggested that DCE-MRI quantitative parameters have a certain value in the differential diagnosis of endometrial cancer,which helped to further distinguish the degree of muscular invasion,clinical stage,and differentiation of endometrial cancer patients. 展开更多
关键词 dynamic contrast enhanced magnetic resonance imaging volume transfer constant rate constant extravascular extracellular space volume ratio endometrial cancer clinicopathological factors
下载PDF
UV Photodissociation Dynamics of Nitric Acid: The Hydroxyl Elimination Channel
15
作者 Feng-yan Wang Zhi-chao Chen +5 位作者 Yong-wei Zhang Quan Shuai Bo Jiang Dong-xu Dai Xiu-yan Wang Xue-ming Yang 《Chinese Journal of Chemical Physics》 SCIE CAS CSCD 2009年第2期191-196,共6页
Sliced velocity mapping ion imaging technique was employed to investigate the dynamics of the hydroxyl elimination channel in the photodissociaiton of nitric acid in the ultraviolet region. The OH product was detected... Sliced velocity mapping ion imaging technique was employed to investigate the dynamics of the hydroxyl elimination channel in the photodissociaiton of nitric acid in the ultraviolet region. The OH product was detected by (2+1) resonance enhanced multiphoton ionization via the D^2∑^- electronic state. The total kinetic energy spectra of the OH+NO2 channel from the photolysis of HONO2 show that both :NO2(X2A1) and NO2(A2B2) channels are present, suggesting that both 1^1A″ and 2^1A″ excited electronic states of HONO2 are involved in the excitation. The parallel angular distributions suggest that the dissociation of the nitric acid is a fast process in comparison with the rotational period of the HNO3 molecule. The anisotropy parameter β for the hydroxyl elimination channel is found to be dependent on the OH product rotational state as well as the photolysis energy. 展开更多
关键词 Slice imaging technique Photodissociation dynamics Nitric acid OH radical Resonance enhanced multiphoton ionization
下载PDF
Femtosecond Stimulated Raman Line Shapes:Dependence on Resonance Conditions of Pump and Probe Pulses
16
作者 ChengChen Liang-dongZhu ChongFang 《Chinese Journal of Chemical Physics》 SCIE CAS CSCD 2018年第4期492-502,614,615,共13页
Resonance enhancement has been increasingly employed in the emergent felntosecond stimu- lated Raman spectroscopy (FSRS) to selectively monitor molecular structure and dynamics with improved spectral and temporal re... Resonance enhancement has been increasingly employed in the emergent felntosecond stimu- lated Raman spectroscopy (FSRS) to selectively monitor molecular structure and dynamics with improved spectral and temporal resolutions and signal-to-noise ratios. Such joint eflforts by the technique- and application-oriented scientists and engineers have laid the foundation for exploiting the tunable FSRS methodology to investigate a great variety of photosensitive systems and elucidate the underlying functional mechanisms on molecular time scales. Dur- ing spectral analysis, peak line shapes remain a major concern with an intricate dependence on resonance conditions. Here, we present a comprehensive study of line shapes by tuning the Rarnan pump wavelength from red to blue side of the ground-state absorption band of the fluorescent dye rhodarnine 6G in solution. Distinct line shape patterns in Stokes and anti-Stokes FSRS as well as from the low to high-frequency modes highlight the competition between multiple third-order and higher-order nonlinear pathways, governed by difl^rent res- onance conditions achieved by Raman pump and probe pulses. In particular, the resonance condition of probe wavelength is revealed to play an important role in generating circular line shape changes through oppositely phased dispersion via hot luminescence (HL) pathways. Meanwhile, on-resonance conditions of the Rarnan pump could promote excited-state vibrational modes which are broadened and red-shifted from the coincident ground-state vibrational modes, posing challenges for spectral analysis. Certain strategies in tuning the Raman pump and probe to characteristic regions across an electronic transition band are discussed to improve the FSRS usability and versatility as a powerful structural dynamics toolset to advance chemical, physical, materials, and biological sciences. 展开更多
关键词 Ferntosecond stimulated Rarnan spectroscopy Resonance enhancement Ra- man pump and probe pulses Wavelength tunability Dispersive line shapes Stokes and anti-Stokes FSRS
下载PDF
Enhancing sensitivity of SERRS nanoprobes by modifying heptamethine cyanine-based reporter molecules
17
作者 Yunfei Zhang Danqi Li +3 位作者 Xingyu Zhou Xihui Gao Shengyuan Zhao Cong Li 《Journal of Innovative Optical Health Sciences》 SCIE EI CAS 2016年第4期85-93,共9页
Surface enhanced resonance Raman scattering(SERRS)is a physical phenomenon that occurs when the energy of incident light is dose to that of electronic excitation of reporter molecules(RMs)attached on substrates.SERRS ... Surface enhanced resonance Raman scattering(SERRS)is a physical phenomenon that occurs when the energy of incident light is dose to that of electronic excitation of reporter molecules(RMs)attached on substrates.SERRS has showed great promise in healthcare applications such as tumor diagnosis,image guided tumor surgery and real-time evaluation of therapeutic response due to its ultra-sensitivity,manipulating convenience and easy acessibility.As the most widely used organic near-infrared(NIR)fuorophore,heptamethine cyanines possess the electronic ex-citation energy that is close to the plasmon absorption energy of the gold nano scafolds,which results in the extraordinary enhancement of the SERRS signal.However,the effect of hepta-methine cyanine structure and the gold nanoparticle morphology to the SERRS intensity are barely investigated.This work developed a series of SERRS nanoprobes in which two hepta-methine cyanine derivatives(IR783 and IR780)were used as the RM and three gold nanoparticles(nanorod,nanosphere and nanostar)were used as the substrates.Interestingly,even though IR780 and IR783 possess very similar chemical structure,SERRS signal produced by IR780 was determined as 14 times higher than that of IR783 when the RM concentration was6.5 × 10^(-6) M.In contrast,less than 4.0 fold SERRS signal intensity increase was measured by changing the substrate morphologies.Above experimental results indicate that finely tuning the chemical structure of the heptamethine cyanine could be a feasible way to develop robust SERRS probes to visualize tumor or guide tumor resection with high sensitivity and target to background ratio. 展开更多
关键词 Surface enhanced resonance Raman scattering gold nanoparticles reporter molecules heptamethine cyanine.
下载PDF
Role of Diffusion-weighted and Contrast-enhanced Magnetic Resonance Imaging in Differentiating Activity of Ankylosing Spondylitis 被引量:9
18
作者 Ying-Hua Zhao Yan-Yan Cao +5 位作者 Qun Zhang Ying-Jie Mei Ji-Jie Xiao Shao-Yong Hu Wei Li Shao-Lin Li 《Chinese Medical Journal》 SCIE CAS CSCD 2017年第11期1303-1308,共6页
Background: Previous studies showed that combining apparent diffusion coefficient (ADC) value with the Spondyloarthritis Research Consortium of Canada (SPARCC) index value might provide a reliable evaluation of t... Background: Previous studies showed that combining apparent diffusion coefficient (ADC) value with the Spondyloarthritis Research Consortium of Canada (SPARCC) index value might provide a reliable evaluation of the activity of ankylosing spondylitis (AS), and that contrast-enhanced (CE) magnetic resonance imaging (MRI) is unnecessary. However, the results were based on confirming only a small random sample. This study aimed to assess the role of CE-MRI in differentiating the disease activity of AS by comparingADC value with a large sample. Methods: A total of l 15 patients with AS were enrolled in accordance with Bath AS Disease Activity Index and laboratory indices, and 115 patients were divided into two groups, including active group (n = 69) and inactive group (n 46). SPARCC, ASI, and ADC values were obtained from the short tau inversion recovery (STIR), diffusion-weighted imaging (DWI), and CE-MRI, respectively. One-way analysis of variance and receiver operating characteristic analysis were performed for all parameters. Results: The optimal cutoff values (with sensitivity, specificity, respective area under the curve, positive likelihood ratio, and negative likelihood ratio) for the differentiation between active and inactive groups are as follows: SPARCC = 6 (72.06%, 82.61%, 0.836, 4.14, 0.34); ASI (%) 153 (80.6%, 84.78%, 0.819, 5.3, 0.23); ADC value - 1.15 × 10 3 mm2/s (72.73% 81.82%, 0.786, 4, 0.33). No statistical differences were found among the predictive values of SPARCC, △SI, and ADC. Multivariate analysis showed no significant difference between the combination of SPARCC and ADC values with and without ASI. Conclusions: Using large sample, we concluded that the combination of STIR and DWI would play significant roles in assessing the disease activity, and CE-MRI sequence is not routinely used in imaging of AS to avoid renal fibrosis and aggravation of kidney disease. 展开更多
关键词 ACTIVITY Ankylosing Spondylitis Diffusion-weighted Imaging enhanced Magnetic Resonance Imaging
原文传递
Classification of breast lesions based on a dual S-shaped logistic model in dynamic contrast enhanced magnetic resonance imaging 被引量:8
19
作者 DANG Yi GUO Li +2 位作者 LV DongJiao WANG XiaoYing ZHANG Jue 《Science China(Life Sciences)》 SCIE CAS 2011年第10期889-896,共8页
This study proposes a novel dual S-shaped logistic model for automatically quantifying the characteristic kinetic curves of breast lesions and for distinguishing malignant from benign breast tumors on dynamic contrast... This study proposes a novel dual S-shaped logistic model for automatically quantifying the characteristic kinetic curves of breast lesions and for distinguishing malignant from benign breast tumors on dynamic contrast enhanced (DCE) magnetic resonance (MR) images.D(,) is the diagnostic parameter derived from the logistic model.Significant differences were found in D(,) between the malignant benign groups.Fisher's Linear Discriminant analysis correctly classified more than 90% of the benign and malignant kinetic breast data using the derived diagnostic parameter (D(,)).Receiver operating characteristic curve analysis of the derived diagnostic parameter (D(,)) indicated high sensitivity and specificity to differentiate malignancy from benignancy.The dual S-shaped logistic model was effectively used to fit the kinetic curves of breast lesions in DCE-MR.Separation between benign and malignant breast lesions was achieved with sufficient accuracy by using the derived diagnostic parameter D(,) as the lesion's feature.The proposed method therefore has the potential for computer-aided diagnosis in breast tumors. 展开更多
关键词 logistic model breast cancer dynamic contrast enhanced magnetic resonance imaging
原文传递
Experimental study on resonance frequency enhancement of strong optical injection-locked semiconductor lasers
20
作者 郭芃 陈章渊 《Chinese Optics Letters》 SCIE EI CAS CSCD 2013年第12期47-49,共3页
Enhancing resonance frequency of strong optical studied. Resonance frequency is increased from technique. We experimentally demonstrate that injection-locked semiconductor lasers is experimentally 4.1 to 53.9 GHz by t... Enhancing resonance frequency of strong optical studied. Resonance frequency is increased from technique. We experimentally demonstrate that injection-locked semiconductor lasers is experimentally 4.1 to 53.9 GHz by the optical injection locking (OIL) resonance frequency is strictly equal to the frequency spacing between the cavity modes of the master and slave lasers under strong OIL condition. This result provides valuable information to improve OIL theory. 展开更多
关键词 VCSEL Experimental study on resonance frequency enhancement of strong optical injection-locked semiconductor lasers
原文传递
上一页 1 2 下一页 到第
使用帮助 返回顶部