In the face of human society's great requirements for health industry,and the much stricter safety and quality standards in the biomedical industry,the demand for advanced membrane separation technologies continue...In the face of human society's great requirements for health industry,and the much stricter safety and quality standards in the biomedical industry,the demand for advanced membrane separation technologies continues to rapidly grow in the world.Nanofiltration(NF)and reverse osmosis(RO)as the highefficient,low energy consumption,and environmental friendly membrane separation techniques,show great promise in the application of biomedical separation field.The chemical compositions,microstructures and surface properties of NF/RO membranes determine the separation accuracy,efficiency and operation cost in their applications.Accordingly,recent studies have focused on tuning the structures and tailoring the performance of NF/RO membranes via the design and synthesis of various advanced membrane materials,and exploring universal and convenient membrane preparation strategies,with the objective of promoting the better and faster development of NF/RO membrane separation technology in the biomedical separation field.This paper reviews the recent studies on the NF/RO membranes constructed with various materials,including the polymeric materials,different dimensional inorganic/organic nanomaterials,porous polymeric materials and metal coordination polymers,etc.Moreover,the influence of membrane chemical compositions,interior microstructures,and surface characteristics on the separation performance of NF/RO membranes,are comprehensively discussed.Subsequently,the applications of NF/RO membranes in biomedical separation field are systematically reported.Finally,the perspective for future challenges of NF/RO membrane separation techniques in this field is discussed.展开更多
The reverse osmosis (RO) separation of aqueous organic solutions, such as alcohols, amines, aldehydes, acids, ketones, and esters etc., by PAA (polyacrylic acid)/PSF (polysulfone) composite membrane has been studied. ...The reverse osmosis (RO) separation of aqueous organic solutions, such as alcohols, amines, aldehydes, acids, ketones, and esters etc., by PAA (polyacrylic acid)/PSF (polysulfone) composite membrane has been studied. It was found that the separation results for aliphatic alcohols, amines and aldehydes are satisfactory, the solute rejection (R-a) and the volume fluxes of solutions (J(V)) for 1000 ppm ethanol, ethylamine and ethyl aldehyde are 66.2%, 61.0%, 84.0% and 0.90 x 10(-6), 0.35 x 10(-6), 0.40 X 10(-6) m(3)/m(2) . s, respectively, at 5.0 MPa and 30 degrees C. R-a increased with increasing molecular weights of alcohols, amines and aldehydes, and the R-a for n-amyl alcohol, n-butylamine and n-butyl aldehyde reached 94.3%, 88.6% and 96.0%, respectively. Satisfactory separation results (R-a > 70%) for ketones, esters, phenols and polyols have been obtained with the PAA/PSF composite membrane. The effect of operating pressure on the properties of reverse osmosis has also been investigated. Analysis of experimental data with Spiegler-Kedem's transport model has been carried out and the membrane constants such as reflection coefficient sigma, solute and hydraulic permeabilities omega and L-p for several organic solutes have been obtained.展开更多
Tanneries reusing wastewater by combination of conventional and advanced Reverse Osmosis (RO) treatment technologies were assessed for technical and economic viabilities. Conventional treatment methods such as neutral...Tanneries reusing wastewater by combination of conventional and advanced Reverse Osmosis (RO) treatment technologies were assessed for technical and economic viabilities. Conventional treatment methods such as neutralization, clari-flocculation and biological processes are followed to clean the effluents before feeding to RO membrane modules. The characteristics of untreated composite effluents such as pH, biochemical oxygen demand (BOD), chemical oxygen demand (COD), total suspended solids (TSS), total dissolved solids (TDS), and total chromium were in the range of 4.00-4.60, 680-3600 mg/L, 1698-7546 mg/L, 980-1480 mg/L, 4200-14500 mg/L, and 26.4-190 mg/L, respectively. Inorganic ions like Ca2+, Na+, Cl– and SO42– were found more in the wastewaters. Conventional treatments significantly removed the organic pollutants however failed to remove dissolved inorganic salts. Membrane technology removed the salts as well as remaining organic pollutants and the product water is reused in the process. The studied tanneries (5 numbers) have achieved 93-98%, 92-99% and 91-96% removal of TDS, sodium and chloride, respectively. Seventy to eighty five percentage of wastewater was recovered and recycled in the industrial processes. The rejects are subject to either solar evaporation system or Multiple Effect Evaporation (MEE) technology. The resulting salts are collected in polythene bags and disposed into scientifically managed secured land fill (SLF) site. The cost of wastewater treatment for operation and maintenances of RO including the pre-treatments (conventional methods) is INR 100-110 m-3.展开更多
The biofouling of RO (Reverse Osmosis) system is one of the most common problems in highly contaminated demineralization and wastewater reuse system. The biological fouling occurs due to the bacteria growth and prol...The biofouling of RO (Reverse Osmosis) system is one of the most common problems in highly contaminated demineralization and wastewater reuse system. The biological fouling occurs due to the bacteria growth and proliferation under nutritive environment, resulting in a dramatic increase of dP (differential pressure) in the RO system, which requires frequent system shutdown for cleaning. This paper discusses the effectiveness of low-dP RO element and periodic flushing on the biofouling scheme of industrial steel mill wastewater reuse system. The low-dP RO element is able to provide low RO system dP, which is expressed to be lower biofouling starting point during the industrial system operation. However, the periodic flushing utilizes fresh water to remove the biofilm deposit along with feed channel. The long term operation performance demonstrated strong caustic is effective in removing the biofilm and recovering RO system performance. It is experimentally validated that, in the case of a high biofouling environment, low-dP RO element and periodic flushing is able to extend the cleaning cycles by 36.6% and 11.4%, respectively. Meanwhile, a joint application of both methods is proven to improve the biofouling control and extend the cleaning cycle by 62.5%, as compared to standard RO technology.展开更多
The experimental results of producing deionized water for the themoelectric factory from two types of the industrial wastewater of an alumina plant by using membrane technology are reported in this paper. For the trea...The experimental results of producing deionized water for the themoelectric factory from two types of the industrial wastewater of an alumina plant by using membrane technology are reported in this paper. For the treatment of the industrial wastewater with high salinity and pH value, the combination of electrodialysis (ED) and reverse osmosis (RO) is utilized, while for the treatment of the low salinity wastewater with low pH value, RO is directly used. The research results show that the above mentioned methods are effective. The technological process of the wastewater treatment with the capacity of 120 tons is designed on the basis of the experimental results.展开更多
The increasing applications of seawater desalination technology have led to the wide usage of polyamide reverse osmosis membranes,resulting in a large number of wasted reverse osmosis membranes.In this work,the base n...The increasing applications of seawater desalination technology have led to the wide usage of polyamide reverse osmosis membranes,resulting in a large number of wasted reverse osmosis membranes.In this work,the base nonwoven layer of the wasted reverse osmosis membrane was successfully modified into the hydrophobic membrane via surface deposition strategy including TiO_(2) and 1H,1H,2H,2H-perfluorooctyltrichlorosilane(PFOTS),respectively.Various techniques were applied to characterize the obtained membranes,which were then used to separate the oil–water system.The optimally modified membrane displayed good hydrophobicity with a contact angle of 135.2°±0.3°,and its oil–water separation performance was as high as 97.8%.After 20 recycle tests,the oil–water separation performance remained more than 96%,which was attributed to the film adhesion of the anchored TiO_(2) and PFOTS layer on the surface.This work might provide a new avenue for recycling the wasted reverse osmosis membrane used in oily wastewater purification.展开更多
Palm oil industry is the most important agro-industry in Malaysia, but its by-product-palm oil mill effluent (POME), posed a great threat to water environment. In the past decades, several treatment and disposal met...Palm oil industry is the most important agro-industry in Malaysia, but its by-product-palm oil mill effluent (POME), posed a great threat to water environment. In the past decades, several treatment and disposal methods have been proposed and investigated to solve this problem. A two-stage pilot-scale plant was designed and constructed for POME treatment. Anaerobic digestion and aerobic biodegradation constituted the first biological stage, while ultrafiltration (UF) and reverse osmosis (RO) membrane units were combined as the second membrane separation stage. In the anaerobic expanded granular sludge bed (EGSB) reactor, about 43% organic matter in POME was converted into biogas, and COD reduction efficiency reached 93% and 22% in EGSB and the following aerobic reactor, respectively. With the treatment in the first biological stage, suspended solids and oil also decreased to a low degree. All these alleviated the membrane fouling and prolonged the membrane life. In the membrane process unit, almost all the suspended solids were captured by UF membranes, while RO membrane excluded most of the dissolved solids or inorganic salts from RO permeate. After the whole treatment processes, organic matter in POME expressed by BOD and COD was removed almost thoroughly. Suspended solids and color were not detectable in RO permeate any more, and mineral elements only existed in trace amount (except for K and Na). The high-quality effluent was crystal clear and could be used as the boiler feed water.展开更多
基金financially supported by the Provincial Key Research and Development Program of Zhejiang Province(2021C01173)the National Natural Science Foundation of China(21975221 and 21776252)。
文摘In the face of human society's great requirements for health industry,and the much stricter safety and quality standards in the biomedical industry,the demand for advanced membrane separation technologies continues to rapidly grow in the world.Nanofiltration(NF)and reverse osmosis(RO)as the highefficient,low energy consumption,and environmental friendly membrane separation techniques,show great promise in the application of biomedical separation field.The chemical compositions,microstructures and surface properties of NF/RO membranes determine the separation accuracy,efficiency and operation cost in their applications.Accordingly,recent studies have focused on tuning the structures and tailoring the performance of NF/RO membranes via the design and synthesis of various advanced membrane materials,and exploring universal and convenient membrane preparation strategies,with the objective of promoting the better and faster development of NF/RO membrane separation technology in the biomedical separation field.This paper reviews the recent studies on the NF/RO membranes constructed with various materials,including the polymeric materials,different dimensional inorganic/organic nanomaterials,porous polymeric materials and metal coordination polymers,etc.Moreover,the influence of membrane chemical compositions,interior microstructures,and surface characteristics on the separation performance of NF/RO membranes,are comprehensively discussed.Subsequently,the applications of NF/RO membranes in biomedical separation field are systematically reported.Finally,the perspective for future challenges of NF/RO membrane separation techniques in this field is discussed.
文摘The reverse osmosis (RO) separation of aqueous organic solutions, such as alcohols, amines, aldehydes, acids, ketones, and esters etc., by PAA (polyacrylic acid)/PSF (polysulfone) composite membrane has been studied. It was found that the separation results for aliphatic alcohols, amines and aldehydes are satisfactory, the solute rejection (R-a) and the volume fluxes of solutions (J(V)) for 1000 ppm ethanol, ethylamine and ethyl aldehyde are 66.2%, 61.0%, 84.0% and 0.90 x 10(-6), 0.35 x 10(-6), 0.40 X 10(-6) m(3)/m(2) . s, respectively, at 5.0 MPa and 30 degrees C. R-a increased with increasing molecular weights of alcohols, amines and aldehydes, and the R-a for n-amyl alcohol, n-butylamine and n-butyl aldehyde reached 94.3%, 88.6% and 96.0%, respectively. Satisfactory separation results (R-a > 70%) for ketones, esters, phenols and polyols have been obtained with the PAA/PSF composite membrane. The effect of operating pressure on the properties of reverse osmosis has also been investigated. Analysis of experimental data with Spiegler-Kedem's transport model has been carried out and the membrane constants such as reflection coefficient sigma, solute and hydraulic permeabilities omega and L-p for several organic solutes have been obtained.
文摘Tanneries reusing wastewater by combination of conventional and advanced Reverse Osmosis (RO) treatment technologies were assessed for technical and economic viabilities. Conventional treatment methods such as neutralization, clari-flocculation and biological processes are followed to clean the effluents before feeding to RO membrane modules. The characteristics of untreated composite effluents such as pH, biochemical oxygen demand (BOD), chemical oxygen demand (COD), total suspended solids (TSS), total dissolved solids (TDS), and total chromium were in the range of 4.00-4.60, 680-3600 mg/L, 1698-7546 mg/L, 980-1480 mg/L, 4200-14500 mg/L, and 26.4-190 mg/L, respectively. Inorganic ions like Ca2+, Na+, Cl– and SO42– were found more in the wastewaters. Conventional treatments significantly removed the organic pollutants however failed to remove dissolved inorganic salts. Membrane technology removed the salts as well as remaining organic pollutants and the product water is reused in the process. The studied tanneries (5 numbers) have achieved 93-98%, 92-99% and 91-96% removal of TDS, sodium and chloride, respectively. Seventy to eighty five percentage of wastewater was recovered and recycled in the industrial processes. The rejects are subject to either solar evaporation system or Multiple Effect Evaporation (MEE) technology. The resulting salts are collected in polythene bags and disposed into scientifically managed secured land fill (SLF) site. The cost of wastewater treatment for operation and maintenances of RO including the pre-treatments (conventional methods) is INR 100-110 m-3.
文摘The biofouling of RO (Reverse Osmosis) system is one of the most common problems in highly contaminated demineralization and wastewater reuse system. The biological fouling occurs due to the bacteria growth and proliferation under nutritive environment, resulting in a dramatic increase of dP (differential pressure) in the RO system, which requires frequent system shutdown for cleaning. This paper discusses the effectiveness of low-dP RO element and periodic flushing on the biofouling scheme of industrial steel mill wastewater reuse system. The low-dP RO element is able to provide low RO system dP, which is expressed to be lower biofouling starting point during the industrial system operation. However, the periodic flushing utilizes fresh water to remove the biofilm deposit along with feed channel. The long term operation performance demonstrated strong caustic is effective in removing the biofilm and recovering RO system performance. It is experimentally validated that, in the case of a high biofouling environment, low-dP RO element and periodic flushing is able to extend the cleaning cycles by 36.6% and 11.4%, respectively. Meanwhile, a joint application of both methods is proven to improve the biofouling control and extend the cleaning cycle by 62.5%, as compared to standard RO technology.
文摘The experimental results of producing deionized water for the themoelectric factory from two types of the industrial wastewater of an alumina plant by using membrane technology are reported in this paper. For the treatment of the industrial wastewater with high salinity and pH value, the combination of electrodialysis (ED) and reverse osmosis (RO) is utilized, while for the treatment of the low salinity wastewater with low pH value, RO is directly used. The research results show that the above mentioned methods are effective. The technological process of the wastewater treatment with the capacity of 120 tons is designed on the basis of the experimental results.
基金We gratefully acknowledge the financial support from the National Natural Science Foundation of China(Grant No.21576205)the Tianjin Natural Science Foundation(Grant No.18JCTPJC48600)the Training Project of Innovation Team of Colleges and Universities in Tianjin(GrantNo.TD13-5020).
文摘The increasing applications of seawater desalination technology have led to the wide usage of polyamide reverse osmosis membranes,resulting in a large number of wasted reverse osmosis membranes.In this work,the base nonwoven layer of the wasted reverse osmosis membrane was successfully modified into the hydrophobic membrane via surface deposition strategy including TiO_(2) and 1H,1H,2H,2H-perfluorooctyltrichlorosilane(PFOTS),respectively.Various techniques were applied to characterize the obtained membranes,which were then used to separate the oil–water system.The optimally modified membrane displayed good hydrophobicity with a contact angle of 135.2°±0.3°,and its oil–water separation performance was as high as 97.8%.After 20 recycle tests,the oil–water separation performance remained more than 96%,which was attributed to the film adhesion of the anchored TiO_(2) and PFOTS layer on the surface.This work might provide a new avenue for recycling the wasted reverse osmosis membrane used in oily wastewater purification.
文摘Palm oil industry is the most important agro-industry in Malaysia, but its by-product-palm oil mill effluent (POME), posed a great threat to water environment. In the past decades, several treatment and disposal methods have been proposed and investigated to solve this problem. A two-stage pilot-scale plant was designed and constructed for POME treatment. Anaerobic digestion and aerobic biodegradation constituted the first biological stage, while ultrafiltration (UF) and reverse osmosis (RO) membrane units were combined as the second membrane separation stage. In the anaerobic expanded granular sludge bed (EGSB) reactor, about 43% organic matter in POME was converted into biogas, and COD reduction efficiency reached 93% and 22% in EGSB and the following aerobic reactor, respectively. With the treatment in the first biological stage, suspended solids and oil also decreased to a low degree. All these alleviated the membrane fouling and prolonged the membrane life. In the membrane process unit, almost all the suspended solids were captured by UF membranes, while RO membrane excluded most of the dissolved solids or inorganic salts from RO permeate. After the whole treatment processes, organic matter in POME expressed by BOD and COD was removed almost thoroughly. Suspended solids and color were not detectable in RO permeate any more, and mineral elements only existed in trace amount (except for K and Na). The high-quality effluent was crystal clear and could be used as the boiler feed water.