A new reversed-phase high performance liquid chromatography method was developed to quantitate the activity of xanthine oxidase involved in milk fat globule membrane with xanthine as the substrate and the separation o...A new reversed-phase high performance liquid chromatography method was developed to quantitate the activity of xanthine oxidase involved in milk fat globule membrane with xanthine as the substrate and the separation of product (uric acid). The increment of uric acid in the reaction system was used to calculate the total activity of XO. The optimized assay conditions, linearity of detection, recovery of uric acid and chromatogram were developed in text, indicating this method is simple, rapid and efficient. It is an alternative potential method for the determination of the activity of XO in milk.展开更多
A rapid, fast and precise method has been developed and validated for the simultaneous determination of amlodipine with H1-receptor antagonists (cetirizine, fexofenadine, and buclizine) from dosage forms. The chromato...A rapid, fast and precise method has been developed and validated for the simultaneous determination of amlodipine with H1-receptor antagonists (cetirizine, fexofenadine, and buclizine) from dosage forms. The chromatography was performed on a Purospher? Star, C18 (5 mm, 250 × 4.6 mm) column using acetonitrile: buffer (0.01 mM) (40:60, v/v, pH adjusted to 3.0), as a mobile phase. The mobile phase was pumped at a flow rate of 1.0 mL·min-1 and UV detection was performed at 240 nm. The method was validated for linearity, accuracy, precision and specificity. The method was applied to study the interaction between amlodipine and H1-receptor antagonists. These interactions were carried out in simulated gastric juice (pH 1), simulated full stomach (pH 4), blood pH (pH 7.4) and simulating GI (pH 9). The interacting drugs were heated at 37℃ with intermit-tent shaking and the samples were withdrawn every thirty minutes for three hours and drug contents were analyzed by RP-HPLC techniques. In most cases the in vitro availability of amlodipine was decreased. It was observed that the change in in vitro availability was pH dependent.展开更多
AIM:To determine moxonidine in aqueous humor and iris-ciliary body by reversed-phase high performance liquid chromatography(RP-HPLC),and to evaluate the retinal neuroprotective effect after topical administration with...AIM:To determine moxonidine in aqueous humor and iris-ciliary body by reversed-phase high performance liquid chromatography(RP-HPLC),and to evaluate the retinal neuroprotective effect after topical administration with moxonidine in a high intraocular pressure(IOP)model.METHODS:The eyes of albino rabbits were administered topically and ipsilaterally with 0.2%moxonidine.A RPHPLC method was employed for the identification and quantification of moxonidine between 2 and 480 min,which presented in the aqueous humor and iris-ciliary body.Flash electroretinography(F-ERG)amplitude and superoxide dismutase(SOD)level were measured between day 1 and day 15 after topical administration with moxonidine in a rabbit model of high IOP.Histological and ultrastructural observation underwent to analyze the changes of retinal morphology,the inner retinal layers(IRL)thickness,and retinal ganglion cell(RGC)counting.RESULTS:Moxonidine was detectable between 2 and 480 min after administration,and the peak concentration developed both in the two tissues at 30 min,0.51μg/m Lin aqueous humor and 1.03μg/g in iris-ciliary body.In comparison to control,F-ERG b-wave amplitude in moxonidine eyes were significantly differences between day 3 and day 15(P<0.01)in the high IOP model;SOD levels were significantly higher at all time-points(P<0.01)with a maximum level of 20.29 U/mgprot at day 15;and RGCs were significantly higher(P<0.05).CONCLUSION:Moxonidine is a viable neuroprotective agent with application to high IOP model.All layers of retina,including RGC layer,retinal nerve fiber layer and INL,are more preserved after moxonidine administration.SOD plays a neuroprotective role in ocular hypertension-mediated RGC death.展开更多
The research was carried out for establishing a new reverse phase-HPLC stability indicating method for the quantification of Rucaparib. The experiment was determined on Waters HPLC instrument using 996 photo-diode arr...The research was carried out for establishing a new reverse phase-HPLC stability indicating method for the quantification of Rucaparib. The experiment was determined on Waters HPLC instrument using 996 photo-diode array detector. The separation was done by using symmetry C-18 ODS (25 cm × 0.46 cm internal diameter) 5 μm analytical column containing mobile phase of Phosphate buffer (0.02 M) and methanol [65:35% v/v] adjusted pH to 4.8 by adding dilute ortho phosphoric acid. The method was run at 1 ml·min<sup>-1</sup> at 286 nm detection. The drug was eluted at 5.484 min. After developing the method, it was assured for the intended use by validation which was done according to ICH Q2B guidelines. The analytical parameters checked were linearity, accuracy, repeatability, intermediate precision, limit of detection, limit of quantitation, ruggedness and robustness. It was observed that the response of the detector was linear in the range of 6 - 14 μg/ml with correlation coefficient of 0.999. The results of all the parameters were found to be within the acceptance criteria. The stability indicating assay method was established by using the samples generated by forced degradation process. The forced degradation was carried out by subjecting the drug to acid, alkali, thermal, oxidative and photolytic degradation and the results showed that the degradation products were successfully separated from the drug. Hence, this can be applied perfectly later for the analysis of quality of the rucaparib drug.展开更多
The research was carried out to establish a new reverse phase-HPLC stability indicating method for quantifying Bimatoprost & Timolol in ophthalmic solution. The experiment of Bimatoprost & Timolol in ophthalmi...The research was carried out to establish a new reverse phase-HPLC stability indicating method for quantifying Bimatoprost & Timolol in ophthalmic solution. The experiment of Bimatoprost & Timolol in ophthalmic solution method development was determined on Waters HPLC instrument using a UV Detector. The separation was done by using L11, Zorbex SB phenyl (4.6 mm × 250 mm internal diameter) 5 μm analytical column, containing mobile phase of Phosphate buffer (0.02 M), methanol, and acetonitrile [50:30:20 % v/v]. The method was run at 1 ml·min<sup>-1</sup> at 210 nm for Bimatoprost and 295 nm for Timolol for detection. The drug was eluted at 10.81 min for Bimatoprost and 3.77 min for Timolol. After developing the method, it was assured for the intended use by validation, which was done according to ICH Q2B guidelines. The analytical parameters checked were Specificity/Selectivity, linearity, Range, accuracy, ruggedness, and robustness. It was observed that the response of the detector was linear in the range of 6 - 18 μg/ml with a correlation coefficient of 0.999. The results of all the parameters were found to be within the acceptance criteria. The stability-indicating assay method was established by using the samples generated by the forced degradation process. The forced degradation was carried out by subjecting the drug to acid, alkali, thermal, oxidative, and photolytic degradation, and the results showed that the degradation products were successfully separated from the drug. Hence, this can be applied perfectly later for the quantitative analysis of Bimatoprost 0.3% + Timolol 0.5% Ophthalmic Solution drugs for pharmaceutical use. Currently, there is no official method for Bimatoprost & Timolol combination products in USP or BP. Available research work related to single Bimatoprost or Timolol products was not suitable for testing Bimatoprost and Timolol combination drugs. Additionally, there is no stability-indicating method to test Bimatoprost & Timolol combination products which insist us to do research and develop a new reverse phase-HPLC indicating method which will be faster and more accurate.展开更多
The interaction index c which was derived from the fundamental retention equationlogk’ =a + cC_B in reversed--phase high--performancc liquid chromatography (RP-HPLC) quan-titatively describes the difference in the in...The interaction index c which was derived from the fundamental retention equationlogk’ =a + cC_B in reversed--phase high--performancc liquid chromatography (RP-HPLC) quan-titatively describes the difference in the interaction between solute--strong. solvent andsolute--weak solvent; it has shown to be a constant for a specific solute even when columnsystems with different C18 packings are used. The theoretical basis for peak identificationby using interaction index has been proposed, which was based on the a,c values on stan-dard C18 column by utilizing linear a-a plots on column pairs and the linear relationship be-tween parameters a and c for the structural related compounds. Through the establishmentof parameters a,c data based on the standard C18 column for a certain type of compounds,the retention of thesc compounds on various C18 columns can be predicted. Typical exam-ples have been given to verify the correctness of this method.展开更多
文摘A new reversed-phase high performance liquid chromatography method was developed to quantitate the activity of xanthine oxidase involved in milk fat globule membrane with xanthine as the substrate and the separation of product (uric acid). The increment of uric acid in the reaction system was used to calculate the total activity of XO. The optimized assay conditions, linearity of detection, recovery of uric acid and chromatogram were developed in text, indicating this method is simple, rapid and efficient. It is an alternative potential method for the determination of the activity of XO in milk.
文摘A rapid, fast and precise method has been developed and validated for the simultaneous determination of amlodipine with H1-receptor antagonists (cetirizine, fexofenadine, and buclizine) from dosage forms. The chromatography was performed on a Purospher? Star, C18 (5 mm, 250 × 4.6 mm) column using acetonitrile: buffer (0.01 mM) (40:60, v/v, pH adjusted to 3.0), as a mobile phase. The mobile phase was pumped at a flow rate of 1.0 mL·min-1 and UV detection was performed at 240 nm. The method was validated for linearity, accuracy, precision and specificity. The method was applied to study the interaction between amlodipine and H1-receptor antagonists. These interactions were carried out in simulated gastric juice (pH 1), simulated full stomach (pH 4), blood pH (pH 7.4) and simulating GI (pH 9). The interacting drugs were heated at 37℃ with intermit-tent shaking and the samples were withdrawn every thirty minutes for three hours and drug contents were analyzed by RP-HPLC techniques. In most cases the in vitro availability of amlodipine was decreased. It was observed that the change in in vitro availability was pH dependent.
基金Supported by the Key Science and Technology Program of Shaanxi Province,China(No.2015SF146).
文摘AIM:To determine moxonidine in aqueous humor and iris-ciliary body by reversed-phase high performance liquid chromatography(RP-HPLC),and to evaluate the retinal neuroprotective effect after topical administration with moxonidine in a high intraocular pressure(IOP)model.METHODS:The eyes of albino rabbits were administered topically and ipsilaterally with 0.2%moxonidine.A RPHPLC method was employed for the identification and quantification of moxonidine between 2 and 480 min,which presented in the aqueous humor and iris-ciliary body.Flash electroretinography(F-ERG)amplitude and superoxide dismutase(SOD)level were measured between day 1 and day 15 after topical administration with moxonidine in a rabbit model of high IOP.Histological and ultrastructural observation underwent to analyze the changes of retinal morphology,the inner retinal layers(IRL)thickness,and retinal ganglion cell(RGC)counting.RESULTS:Moxonidine was detectable between 2 and 480 min after administration,and the peak concentration developed both in the two tissues at 30 min,0.51μg/m Lin aqueous humor and 1.03μg/g in iris-ciliary body.In comparison to control,F-ERG b-wave amplitude in moxonidine eyes were significantly differences between day 3 and day 15(P<0.01)in the high IOP model;SOD levels were significantly higher at all time-points(P<0.01)with a maximum level of 20.29 U/mgprot at day 15;and RGCs were significantly higher(P<0.05).CONCLUSION:Moxonidine is a viable neuroprotective agent with application to high IOP model.All layers of retina,including RGC layer,retinal nerve fiber layer and INL,are more preserved after moxonidine administration.SOD plays a neuroprotective role in ocular hypertension-mediated RGC death.
文摘The research was carried out for establishing a new reverse phase-HPLC stability indicating method for the quantification of Rucaparib. The experiment was determined on Waters HPLC instrument using 996 photo-diode array detector. The separation was done by using symmetry C-18 ODS (25 cm × 0.46 cm internal diameter) 5 μm analytical column containing mobile phase of Phosphate buffer (0.02 M) and methanol [65:35% v/v] adjusted pH to 4.8 by adding dilute ortho phosphoric acid. The method was run at 1 ml·min<sup>-1</sup> at 286 nm detection. The drug was eluted at 5.484 min. After developing the method, it was assured for the intended use by validation which was done according to ICH Q2B guidelines. The analytical parameters checked were linearity, accuracy, repeatability, intermediate precision, limit of detection, limit of quantitation, ruggedness and robustness. It was observed that the response of the detector was linear in the range of 6 - 14 μg/ml with correlation coefficient of 0.999. The results of all the parameters were found to be within the acceptance criteria. The stability indicating assay method was established by using the samples generated by forced degradation process. The forced degradation was carried out by subjecting the drug to acid, alkali, thermal, oxidative and photolytic degradation and the results showed that the degradation products were successfully separated from the drug. Hence, this can be applied perfectly later for the analysis of quality of the rucaparib drug.
文摘The research was carried out to establish a new reverse phase-HPLC stability indicating method for quantifying Bimatoprost & Timolol in ophthalmic solution. The experiment of Bimatoprost & Timolol in ophthalmic solution method development was determined on Waters HPLC instrument using a UV Detector. The separation was done by using L11, Zorbex SB phenyl (4.6 mm × 250 mm internal diameter) 5 μm analytical column, containing mobile phase of Phosphate buffer (0.02 M), methanol, and acetonitrile [50:30:20 % v/v]. The method was run at 1 ml·min<sup>-1</sup> at 210 nm for Bimatoprost and 295 nm for Timolol for detection. The drug was eluted at 10.81 min for Bimatoprost and 3.77 min for Timolol. After developing the method, it was assured for the intended use by validation, which was done according to ICH Q2B guidelines. The analytical parameters checked were Specificity/Selectivity, linearity, Range, accuracy, ruggedness, and robustness. It was observed that the response of the detector was linear in the range of 6 - 18 μg/ml with a correlation coefficient of 0.999. The results of all the parameters were found to be within the acceptance criteria. The stability-indicating assay method was established by using the samples generated by the forced degradation process. The forced degradation was carried out by subjecting the drug to acid, alkali, thermal, oxidative, and photolytic degradation, and the results showed that the degradation products were successfully separated from the drug. Hence, this can be applied perfectly later for the quantitative analysis of Bimatoprost 0.3% + Timolol 0.5% Ophthalmic Solution drugs for pharmaceutical use. Currently, there is no official method for Bimatoprost & Timolol combination products in USP or BP. Available research work related to single Bimatoprost or Timolol products was not suitable for testing Bimatoprost and Timolol combination drugs. Additionally, there is no stability-indicating method to test Bimatoprost & Timolol combination products which insist us to do research and develop a new reverse phase-HPLC indicating method which will be faster and more accurate.
文摘The interaction index c which was derived from the fundamental retention equationlogk’ =a + cC_B in reversed--phase high--performancc liquid chromatography (RP-HPLC) quan-titatively describes the difference in the interaction between solute--strong. solvent andsolute--weak solvent; it has shown to be a constant for a specific solute even when columnsystems with different C18 packings are used. The theoretical basis for peak identificationby using interaction index has been proposed, which was based on the a,c values on stan-dard C18 column by utilizing linear a-a plots on column pairs and the linear relationship be-tween parameters a and c for the structural related compounds. Through the establishmentof parameters a,c data based on the standard C18 column for a certain type of compounds,the retention of thesc compounds on various C18 columns can be predicted. Typical exam-ples have been given to verify the correctness of this method.