期刊文献+
共找到25,034篇文章
< 1 2 250 >
每页显示 20 50 100
Simultaneous Determination of Amlodipine with H<sub>1</sub>-Receptor Antagonists by Reversed Phase High Performance Liquid Chromatography and Application to Interaction Studies
1
作者 Muhammad Saeed Arayne Najma Sultana +1 位作者 Saima Sher Bahadur Muhammad Nawaz 《American Journal of Analytical Chemistry》 2012年第9期632-637,共6页
A rapid, fast and precise method has been developed and validated for the simultaneous determination of amlodipine with H1-receptor antagonists (cetirizine, fexofenadine, and buclizine) from dosage forms. The chromato... A rapid, fast and precise method has been developed and validated for the simultaneous determination of amlodipine with H1-receptor antagonists (cetirizine, fexofenadine, and buclizine) from dosage forms. The chromatography was performed on a Purospher? Star, C18 (5 mm, 250 × 4.6 mm) column using acetonitrile: buffer (0.01 mM) (40:60, v/v, pH adjusted to 3.0), as a mobile phase. The mobile phase was pumped at a flow rate of 1.0 mL·min-1 and UV detection was performed at 240 nm. The method was validated for linearity, accuracy, precision and specificity. The method was applied to study the interaction between amlodipine and H1-receptor antagonists. These interactions were carried out in simulated gastric juice (pH 1), simulated full stomach (pH 4), blood pH (pH 7.4) and simulating GI (pH 9). The interacting drugs were heated at 37℃ with intermit-tent shaking and the samples were withdrawn every thirty minutes for three hours and drug contents were analyzed by RP-HPLC techniques. In most cases the in vitro availability of amlodipine was decreased. It was observed that the change in in vitro availability was pH dependent. 展开更多
关键词 AMLODIPINE CETIRIZINE FEXOFENADINE Buclizine INTERACTIONS reversed phase high performance liquid chromatography
下载PDF
Determination of Benzo[a]pyrene in Edible Oil by High Performance Liquid Chromatography-Fluorescence Detector (HPLC-FL)
2
作者 Guixia YANG Jie LIU +3 位作者 Xiujuan WANG Fenglan ZHANG Kun XIN Chunli KONG 《Agricultural Biotechnology》 2024年第2期8-9,19,共3页
In this study, an optimized high performance liquid chromatography-fluorescence detector (HPLC-FL) method for the determination of benzo[a]pyrene in edible oil was established. HPLC was performed with Thermo Fisher Sc... In this study, an optimized high performance liquid chromatography-fluorescence detector (HPLC-FL) method for the determination of benzo[a]pyrene in edible oil was established. HPLC was performed with Thermo Fisher Scientific C18 column (250 mm×4.6 mm, 5 μm) as the chromatographic column and acetonitrile and water as the mobile phase, and the excitation wavelength and emission wavelength of fluorescence detector were 286 and 430 nm, respectively. The response was high, and the linear range was 0.5-10.0 ng/ml. The lowest limit of detection was 0.11 ng/ml, and the average recovery was 92.5%. This method is suitable for quantitative analysis of benzo[a]pyrene content in edible oil. 展开更多
关键词 BENZO[A]PYRENE high performance liquid chromatography Fluorescence detector
下载PDF
Determination of gouty arthritis' biomarkers in human urine using reversed-phase high-performance liquid chromatography 被引量:4
3
作者 Lei-Wen Xiang Jing Li +1 位作者 Jin-Ming Lin Hai-Fang Li 《Journal of Pharmaceutical Analysis》 SCIE CAS 2014年第2期153-158,共6页
Creatinine, uric acid, hypoxanthine and xanthine are important diagnostic biomarkers in human urine for gouty arthritis or renal disease diacrisis. A simple method for simultaneous determination of these biomarkers in... Creatinine, uric acid, hypoxanthine and xanthine are important diagnostic biomarkers in human urine for gouty arthritis or renal disease diacrisis. A simple method for simultaneous determination of these biomarkers in urine based on reversed-phase high-performance liquid chromatography(RPHPLC) with ultraviolet(UV) detector was proposed. After pretreatment by dilution, centrifugation and filtration, the biomarkers in urine samples were separated by ODS-BP column by elution with methanol/50 mM NaH2PO4 buffer solution at pH 5.26(5:95). Good linearity between peak areas and concentrations of standards was obtained for the biomarkers with correlation coefficients in the range of 0.9957–0.9993.The proposed analytical method has satisfactory repeatability(the recovery of data in a range of creatinine, uric acid, hypoxanthine and xanthine was 93.49–97.90%, 95.38–96.45%, 112.46–115.78% and90.82–97.13% with standard deviation of o5%, respectively) and the limits of detection(LODs, S/NZ3)for creatinine, uric acid, hypoxanthine, and xanthine were 0.010, 0.025, 0.050 and 0.025 mg/L,respectively. The established method was proved to be simple, accurate, sensitive and reliable for the quantitation of gouty arthritis' biomarkers in human urine samples. The ratio of creatinine to uric acid was found to be a possible factor for assessment of gouty arthritis. 展开更多
关键词 反相高效液相色谱法 生物标志物 同时测定 关节炎 痛风 人尿 RP-HPLC 次黄嘌呤
下载PDF
A Sensitive Reversed-Phase High-Performance Liquid Chromatography Method for the Quantitative Determination of Milk Xanthine Oxidase Activity 被引量:1
4
作者 Zhongqin Li Ruizhang Guan Hongwei Liu 《Open Journal of Medicinal Chemistry》 2013年第1期26-30,共5页
A new reversed-phase high performance liquid chromatography method was developed to quantitate the activity of xanthine oxidase involved in milk fat globule membrane with xanthine as the substrate and the separation o... A new reversed-phase high performance liquid chromatography method was developed to quantitate the activity of xanthine oxidase involved in milk fat globule membrane with xanthine as the substrate and the separation of product (uric acid). The increment of uric acid in the reaction system was used to calculate the total activity of XO. The optimized assay conditions, linearity of detection, recovery of uric acid and chromatogram were developed in text, indicating this method is simple, rapid and efficient. It is an alternative potential method for the determination of the activity of XO in milk. 展开更多
关键词 XANTHINE OXIDASE (XO) ENZYME Activity Assay reversed-phase high performance liquid chromatography (RP-HPLC)
下载PDF
Enantiomeric separation of phenylsuccinic acid by cyclodextrin-modified reversed phase high-performance liquid chromatography 被引量:1
5
作者 满瑞林 王钟辉 唐课文 《Journal of Central South University》 SCIE EI CAS 2009年第2期201-205,共5页
The chiral separation of phenylsuccinic acid(PSA)was studied by reversed phase high-performance liquid chromatography(RP-HPLC)with cyclodextrins(CDs)as chiral mobile phase additives.The effects of types of CDs,concent... The chiral separation of phenylsuccinic acid(PSA)was studied by reversed phase high-performance liquid chromatography(RP-HPLC)with cyclodextrins(CDs)as chiral mobile phase additives.The effects of types of CDs,concentration of hydroxypropyl-β-cyclodextrin(HP-β-CD),percentage of organic modifier,pH value and column temperature on enantioselective separation were investigated.The quantification property of the developed RP-HPLC method was examined.The chiral recognition mechanism of PSA was also discussed.The results show that a baseline separation of PSA enantiomers is achieved on a Lichrospher C18 column(4.6 mm(inner diameter)×250 mm,5μm)with HP-β-CD as chiral mobile phase additive.The capacity factors of R-PSA and S-PSA are 3.94 and 4.80,respectively.The separation factor and resolution are respectively 1.22 and 8.03.The mobile phase is a mixture of acetonitrile and deionized water(20-80,volume ratio)containing 10 mmol/L HP-β-CD and 0.05% trifluoroacetic acid(pH 2.5,adjusted with triethylamine)with a flow rate of 1.0 mL/min.The ultraviolet(UV)detector is set at 254 nm.The likely roles are inclusion interaction,induction and hydrogen bonding between HP-β-CD and PSA enantiomers. 展开更多
关键词 反相高效液相色谱法 有机改性剂 环糊精 手性拆分 手性流动相添加剂 CD光盘 HPLC法 手性分离
下载PDF
Modified reversed-phase high performance liquid chromatography for the determination of leukotriene B_4 and 5-hydroxyeicosatetraenoic acid in peripheral neutrophils of rabbits
6
作者 张敏 尤忠义 +1 位作者 雷政宏 王风君 《Journal of Medical Colleges of PLA(China)》 CAS 1993年第2期192-196,共5页
Modification was made on the reversed-phase high performance liquidchromatography(RP-HPLC)with Yue et al’s method as a base.The modified RP-HPLCwas used to detect leukotriene B<sub>4</sub>(LTB<sub&g... Modification was made on the reversed-phase high performance liquidchromatography(RP-HPLC)with Yue et al’s method as a base.The modified RP-HPLCwas used to detect leukotriene B<sub>4</sub>(LTB<sub>4</sub>)and 5-hydroxyeicosatetraenoic acid(5-HETE).Itwas found that the modified method has the merits of simpler procedures,shortertesting time and more satisfactory efficacy. 展开更多
关键词 LEUKOTRIENE B4 5-hydroxyeicosatetraenoic acid chromatography high performance liquid NEUTROPHILS animal RABBITS
下载PDF
Quantitative analysis by reversed-phase high-performance liquid chromatography and retinal neuroprotection after topical administration of moxonidine
7
作者 Qian Zhang Mei-Fang Chu +5 位作者 Yan-Hong Li Chun-Hua Li Run-Jia Lei Si-Cen Wang Bao-Jun Xiao Jian-Gang Yang 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2020年第3期390-398,共9页
AIM:To determine moxonidine in aqueous humor and iris-ciliary body by reversed-phase high performance liquid chromatography(RP-HPLC),and to evaluate the retinal neuroprotective effect after topical administration with... AIM:To determine moxonidine in aqueous humor and iris-ciliary body by reversed-phase high performance liquid chromatography(RP-HPLC),and to evaluate the retinal neuroprotective effect after topical administration with moxonidine in a high intraocular pressure(IOP)model.METHODS:The eyes of albino rabbits were administered topically and ipsilaterally with 0.2%moxonidine.A RPHPLC method was employed for the identification and quantification of moxonidine between 2 and 480 min,which presented in the aqueous humor and iris-ciliary body.Flash electroretinography(F-ERG)amplitude and superoxide dismutase(SOD)level were measured between day 1 and day 15 after topical administration with moxonidine in a rabbit model of high IOP.Histological and ultrastructural observation underwent to analyze the changes of retinal morphology,the inner retinal layers(IRL)thickness,and retinal ganglion cell(RGC)counting.RESULTS:Moxonidine was detectable between 2 and 480 min after administration,and the peak concentration developed both in the two tissues at 30 min,0.51μg/m Lin aqueous humor and 1.03μg/g in iris-ciliary body.In comparison to control,F-ERG b-wave amplitude in moxonidine eyes were significantly differences between day 3 and day 15(P<0.01)in the high IOP model;SOD levels were significantly higher at all time-points(P<0.01)with a maximum level of 20.29 U/mgprot at day 15;and RGCs were significantly higher(P<0.05).CONCLUSION:Moxonidine is a viable neuroprotective agent with application to high IOP model.All layers of retina,including RGC layer,retinal nerve fiber layer and INL,are more preserved after moxonidine administration.SOD plays a neuroprotective role in ocular hypertension-mediated RGC death. 展开更多
关键词 reversed-phase high-performance liquid chromatography MOXONIDINE RETINAL GANGLION cell NEUROPROTECTION superoxide DISMUTASE
下载PDF
A High-Performance Liquid Chromatography Method for the Simultaneous Determination of Five Index Components in Danhong Injection
8
作者 Yun An Tian Tian +2 位作者 Qinglin Wang Xingchu Gong Chenchen Zhang 《American Journal of Analytical Chemistry》 2023年第11期481-492,共12页
The purpose of this study was to establish a high-performance liquid chromatography (HPLC) method for the simultaneous determination of sodium danshensu, protocatechuic aldehyde, rosmarinic acid, salvianolic acid B, a... The purpose of this study was to establish a high-performance liquid chromatography (HPLC) method for the simultaneous determination of sodium danshensu, protocatechuic aldehyde, rosmarinic acid, salvianolic acid B, and 4-coumaric acid in Danhong injection. The chromatographic method employed was as follows: the column was a Welch Ultimate XB-C18 column (250 mm × 4.6 mm, 10 μm), the mobile phase was a gradient elution of 0.4% formic acid aqueous solution (A) and acetonitrile (B), the detection wavelengths were 280 nm for sodium danshensu, protocatechuic aldehyde, and salvianolic acid B and 326 nm for 4-coumaric acid and rosmarinic acid, the sample volume was 10 μL, the flow rate was 1.0 mL/min, and the column temperature was 35°C. This method can realize the separation and determination of sodium danshensu, protocatechuic aldehyde, rosmarinic acid, salvianolic acid B, and 4-coumaric acid within 50 minutes. The linear relationships of the five peak areas and their concentrations are good (R<sup>2</sup>> 0.9997). The precision RSD values are all less than 1.0%. The reproducibility RSD values are all less than 1.3%. The stability RSD values are all less than 2.2%. The recovery values ranged from 92.4% to 99.4%. This method is simple, accurate, and reproducible. It can be used for the determination of sodium danshensu, protocatechuic aldehyde, rosmarinic acid, salvianolic acid B, and 4-coumaric acid in Danhong injection. 展开更多
关键词 Danhong Injection high performance liquid chromatography Phenolic Acid FLAVONOIDS
下载PDF
Creation of reversed phase high-performance liquid chromatographic technique to assay platelet-activating factor 被引量:2
9
作者 杨云梅 曹红翠 +1 位作者 徐哲荣 陈晓明 《Journal of Zhejiang University Science》 CSCD 2004年第6期738-742,共5页
Objective: To establish a new assay for platelet-activating factor (PAF), to compare it with bio-assay; and to discuss its significance in some elderly people diseases such as cerebral infarction and coronary heart di... Objective: To establish a new assay for platelet-activating factor (PAF), to compare it with bio-assay; and to discuss its significance in some elderly people diseases such as cerebral infarction and coronary heart disease. Methods: To measure PAF levels in 100 controls, 23 elderly patients with cerebral infarction and 65 cases with coronary heart disease by reversed phase high-performance liquid chromatographic technique (rHPLC). Results:rHPLC is more convenient, sensitive,specific, and less confusing, compared with bio-assay. The level of plasma PAF in patients with cerebral infarction was higher than that in the controls (P<0.01), and in patients with coronary heart disease. Conclusion: Detection of PAF with rHPLC is more reliable and more accurate. The new assay has important significance in PAF research. 展开更多
关键词 血小板活化因子 反相液相色谱分析 冠心病 脑梗塞 诊断
下载PDF
Isolation and Purification of Unstable Iridoid Glucosides from Traditional Chinese Medicine by Preparative High Performance Liquid Chromatography Coupled with Solid-phase Extraction 被引量:1
10
作者 LI Cun-man XIAO Yuan-sheng +3 位作者 XUE Xing-ya FENG Jia-tao ZHANG Xiu-li LIANG Xin-miao 《Chemical Research in Chinese Universities》 SCIE CAS CSCD 2011年第3期392-396,共5页
An efficient preparative method was successfully developed for isolation and purification of unstable components from medicinal plant extracts, using a combined method of preparative high performance liquid chro-matog... An efficient preparative method was successfully developed for isolation and purification of unstable components from medicinal plant extracts, using a combined method of preparative high performance liquid chro-matography(HPLC) and solid-phase extraction(SPE). The aim of this study was to obtain an effective method with high preparative efficiency and importantly to avoid the transformation of unstable compounds. The preparative HPLC system was based on an LC/MS controlled four-channel autopurification system. The SPE method was performed with a C18 packing material to trap the target compounds and to remove the acidic additive derived from the mobile phase. Using this method, the unstable iridoid glucosides(IGs) as model compounds were successfully isolated and purified from the extract of Hedyotis diffusa Willd. Six IGs(including one new minor IG) and one nucleotide compound were simultaneously obtained, each with a purity of >91% as determined by HPLC. The structures of the isolated compounds were identified by UPLC/Q-TOF MS, UV, 1D and/or 2D NMR. It was demonstrated that the combination of preparative HPLC with SPE is a versatile tool for preparative purification of unstable compounds from complex natural products. 展开更多
关键词 高效液相色谱法 制备方法 环烯醚萜苷 固相萃取 提取纯化 不稳定 分离 制备型高效液相色谱
下载PDF
Stress Degradation Studies on Lisinopril Dihydrate Using Modified Reverse Phase High Performance Liquid Chromatography
11
作者 Elsadig H. K. Adam 《American Journal of Analytical Chemistry》 2014年第5期316-322,共7页
A simple, precise, accurate and sensitive reverse phase high performance liquid chromatographic method for simultaneous estimation of lisinopril dihydrate and its degradation products occuring under different ICH pres... A simple, precise, accurate and sensitive reverse phase high performance liquid chromatographic method for simultaneous estimation of lisinopril dihydrate and its degradation products occuring under different ICH prescribed stress conditions has been modified. Drug was resolved on a C18 column, utilizing modified mobile phase of tetra butyl ammonium hydroxide solution and acetonitrile. Ultra violet detection was carried out at 210 nm. The method was modified with respect to linearity, precision, accuracy, selectivity, specificity and ruggedness. The results obtained revealed that lisinopril dihydrate was an active product slightly changed under stress conditions. 展开更多
关键词 LISINOPRIL DIHYDRATE Stability UV LIGHT Sun LIGHT high Temperature Pharmaceutical EXCIPIENTS high performance liquid chromatography
下载PDF
Porous Monoliths: Stationary Phases of Choice for High Performance Liquid Chromatography in Various Formats
12
作者 SVEC Frantisek 《色谱》 CAS CSCD 北大核心 2005年第6期585-594,共10页
Modern porous monoliths have been conceived as a new class of stationary phases for high performance liquid chromatography(HPLC) in classical columns in the early 1990s and later extended to the capillary format.These... Modern porous monoliths have been conceived as a new class of stationary phases for high performance liquid chromatography(HPLC) in classical columns in the early 1990s and later extended to the capillary format.These monolithic materials are prepared using simple processes carried out in an external mold(inorganic monoliths) or within the confines of the column(organic monoliths and all capillary columns).These methods afford macroporous materials with large through-pores that enable applications in a rapid flow-through mode.Since all the mobile phase must flow through the monolith,the convection considerably accelerates mass transport within the monolithic separation medium and improves the separations.As a result,the monolithic columns perform well even at very high flow rates.The applications of monolithic capillary columns are demonstrated on numerous separations in the HPLC mode. 展开更多
关键词 塑料制品 多孔渗水性 固相 硅土 聚合物 合成方法
下载PDF
Determination of seven active components in Salvia miltiorrhiza herb by matrix solid phase dispersion combined with ion liquid extraction followed by high performance liquid chromatography
13
作者 Bo Hong Yanping Wang +1 位作者 Yinglong Han Wenjing Li 《Asian Journal of Traditional Medicines》 CAS 2021年第2期83-97,共15页
A low cost,rapid and sensitive preparation method of silica gel supported ionic liquid(SGSIL)combined with matrix solid phase dispersion(MSPD)followed by high performance liquid chromatography(HPLC)with ultraviolet de... A low cost,rapid and sensitive preparation method of silica gel supported ionic liquid(SGSIL)combined with matrix solid phase dispersion(MSPD)followed by high performance liquid chromatography(HPLC)with ultraviolet detection(UV)is proposed,and it was applied to determine the seven active compounds in Salvia Miltiorrhiza herb.SGSIL and ionic liquid[BMIM]BF4 were used as the adsorbent and the green elution reagent in the MSPD procedure.Several extraction conditions including type of filler and elution solvent,the volume of elution solvent,material liquid ratio were optimized.Under the optimum conditions,the SGSIL-MSPD-HPLC method showed a low limit of detection(LOD,S/N=3)of 0.0122-0.8788μg/mL for standard solution,limit of quantification(LOQ,S/N=10)of 0.0406-2.9292μg/mL for standard solution,wide linear range from 1.56 to 2000μg/mL for all compounds for standard solution,correlation coefficients(r)of more than 0.9990,acceptable reproducibility(relative standard deviations,RSDs<3.54%),and precision of RSDs<3.36%for intra-day,RSDs<3.50%for inter-day.The satisfactory recoveries ranged from 96.4 to 102.5,with RSDs less than 3.45%.The developed SGSIL-MSPD method is easier and more suitable for the determination of the seven active compounds in Salvia Miltiorrhiza herb than the traditional ultrasonic extraction.It was an effective and efficient method for the extraction and quantification of the seven active compounds in traditional Chinese herbal samples. 展开更多
关键词 high performance liquid chromatography(HPLC) silica gel supported ionic liquid(SGSIL) matrix solid phase dispersion(MSPD) Salvia miltiorrhiza(SM) DETERMINATION
下载PDF
Determination of Quinolone Antibiotics in Water Using Solid Phase Extraction-High Performance Liquid Chromatography-Fluorescence Method
14
作者 WANG Qiao-jun YI Ru-han MO Ce-hui 《Animal Husbandry and Feed Science》 CAS 2011年第2期45-48,共4页
[Objective] To develop a solid phase extraction-high performance liquid chromatography-fluorescence method for determination of quinolone antibiotics in water. [Method] The standard curves of four quinolones (norfloxa... [Objective] To develop a solid phase extraction-high performance liquid chromatography-fluorescence method for determination of quinolone antibiotics in water. [Method] The standard curves of four quinolones (norfloxacin, ciprofloxacin, lomefloxacin and enrofloxacin) were prepared. The detection limit in water and recovery were determined. The water samples collected from different areas, river and tap water were treated using solid-phase extraction method and analyzed by high performance liquid chromatography. Then the concentration of quinolones antibiotics was determined by fluorescence method. [Result] The detection limit of quinolone antibiotics in water was 0.083-0.248 μg/L, and their recovery was 63.7%-134.1%. The four quinolone antibiotics at different levels were detected in various water samples, and the total concentration of quinolone antibiotics was 0.045-3.969 μg/L. The total concentration of quinolone antibiotics was higher in the water samples collected from rivers in Shenzhen area than in the sewage samples. The four quinolone antibiotics could be detected in all tap water samples. [Conclusion] The solid phase extraction-high performance liquid chromatography-fluorescence method is feasible and effective to detect quinolones in water. In addition, this method needs low cost and can meet requirements of daily monitoring and analysis. 展开更多
关键词 喹诺酮类抗生素 高效液相色谱法 浓度测定 固相萃取 荧光法 中水 喹诺酮类药物 样本采集
下载PDF
Trace Determination of Tamoxifen in Biological Fluids Using Hollow Fiber Liquid-Phase Microextraction Followed by High-Performance Liquid Chromatography-Ultraviolet Detection
15
作者 Amir Kashtiaray Hadi Farahani +2 位作者 Sharareh Farhadi Bertrand Rochat Hamid Reza Sobhi 《American Journal of Analytical Chemistry》 2011年第4期429-436,共8页
The applicability of hollow fiber liquid-phase microextraction (HF-LPME) combined with high-performance liquid chromatography-ultraviolet detection (HPLC-UV) was evaluated for the extraction and determination of tamox... The applicability of hollow fiber liquid-phase microextraction (HF-LPME) combined with high-performance liquid chromatography-ultraviolet detection (HPLC-UV) was evaluated for the extraction and determination of tamoxifen (TAM) in biological fluids including human urine and plasma. The drug was extracted from a 15 mL aqueous sample (source phase;SP) into an organic phase impregnated in the pores of the hollow fiber (membrane phase;MP) followed by the back-extraction into a second aqueous solution (receiving phase;RP) located in the lumen of the hollow fiber. The effects of several factors such as the nature of organic solvent, compositions of SP and RP solutions, extraction time, ionic strength and stirring rate on the extraction efficiency were examined and optimized. An enrichment factor of 360 along with substantial sample clean up was obtained under the optimized conditions. The calibration curve showed linearity in the range of 1 - 500 ng?mL–1 and the limit of detection was found to be 0.5 ng?mL–1 in aqueous medium. A reasonable relative recovery (≥89%) and satisfactory intra-assay (3.7% - 4.2%, n = 3) and inter-assay (7.5% - 7.8%, n = 3) precision illustrated good performance of the analytical procedure in spiked human urine and plasma samples. 展开更多
关键词 high-performance liquid chromatography-Ultraviolet Detection HOLLOW Fiber liquid-phase MICROEXTRACTION Human URINE And Plasma Samples TAMOXIFEN
下载PDF
Determination of the Flavonoids from Ginkgo Biloba Extract by High Performance Liquid Chromatography 被引量:3
16
作者 Li ZHANG Zhi Min XIANG 《Chinese Chemical Letters》 SCIE CAS CSCD 2002年第10期968-970,共3页
HPLC method for analysis of the flavonoids from ginkgo biloba extract (GBE) was studied. By suitable selection of columns, symmetrical chromatographic peaks were obtained without using acidic modifier in the mobile ph... HPLC method for analysis of the flavonoids from ginkgo biloba extract (GBE) was studied. By suitable selection of columns, symmetrical chromatographic peaks were obtained without using acidic modifier in the mobile phase, which can eliminate the time for cleaning the chromatographic system and simplify the analystic method for GBE. Experimental conditions: column: Hypersil BDS C18,5mm×4×250 mm; column temperature: 35C; mobile phase: 46% methanol-54% water; flow rate: 0.7 mL/min; detection wavelength: 360nm. 展开更多
关键词 ginkgo biloba extract flavone glycoside high performance liquid chromatography
下载PDF
Fingerprint analysis of placenta polypeptide injection by high performance liquid chromatography 被引量:2
17
作者 Li Huanga, Xiao-Man Wub, Yu Jib, Yu Wanga,baChina Pharmaceutical University, Nanjing 210009, China bJiangsu Institute for Food and Drug Control, Nanjing 210008, China 《Journal of Pharmaceutical Analysis》 SCIE CAS 2012年第1期71-75,共5页
Objective: To develop the representative fingerprint for the quality control of placenta polypeptide injection. Methods: The chromatographic separation was performed using a Phenomenex Gemini C18 column (250 mm 4.6 mm... Objective: To develop the representative fingerprint for the quality control of placenta polypeptide injection. Methods: The chromatographic separation was performed using a Phenomenex Gemini C18 column (250 mm 4.6 mm, 5 mm) maintained at 30 1C. 0.1% aqueous trifiuoroacetic acid (Solvent A) and acetonitrile contained 0.1% TFA (Solvent B) were used as mobile phase with a gradient elution. Detection wavelength was 280 nm with the sample injection volume of 50 mL; the fiow rate was 1.0 mL/min. The fingerprints of different samples were investigated by similarity analysis. Results: Nine peaks were identified as the characteristic common peaks. The similarities of the fingerprints of the 10 batches of samples were above 0.992. Conclusion: This method showed high precision and good repeatability, and provided the basis for the improvement of the quality control of placenta polypeptide injection. 展开更多
关键词 Placenta polypeptide injection FINGERPRINT Similarity analysis high performance liquid chromatography
下载PDF
Determination of 17<i>α</i>-Methyltestosterone in Freshwater Samples of Tilapia Farming by High Performance Liquid Chromatography 被引量:3
18
作者 Isabel R. Barbosa Sara Lopes +3 位作者 Rhaul Oliveira Inês Domingues Amadeu M. V. M. Soares António J. A. Nogueira 《American Journal of Analytical Chemistry》 2013年第4期207-211,共5页
17α-methyltestosterone is used to induce the sex reversal of Tilapia sp. to obtain cultures mono-sex to an economically viable. This practice may lead to environmental contamination and problems in human health. Ther... 17α-methyltestosterone is used to induce the sex reversal of Tilapia sp. to obtain cultures mono-sex to an economically viable. This practice may lead to environmental contamination and problems in human health. Therefore methods need to be developed to detect residues of 17α-methyltestosterone in aqueous matrices. A simple high-performance liquid chromatographic method using ultraviolet detection (245 nm) and testosterone as internal standard has been developed for the monitoring 17α-methyltestosterone in freshwater samples of tilapia aquaculture. The method described involves limited sample preparation as it includes a filtration followed by a single solid-phase extraction step using C18 cartridge. Validation data indicated that the HPLC-UV method for 17α-methyltestosterone determination in the concentration range of 50 - 2000 μg/L provided good linearity, sensitivity, accuracy and precision. Method performance was efficiently applied to monitoring the freshwater samples of fish ponds and the surrounding aquatic channels. 展开更多
关键词 17α-Methyltestosterone high performance liquid chromatography Environment TILAPIA FARMING
下载PDF
Detection of 36 antibiotics in coastal waters using high performance liquid chromatography-tandem mass spectrometry 被引量:13
19
作者 那广水 顾佳 +4 位作者 葛林科 张蓬 王震 刘春阳 张琳 《Chinese Journal of Oceanology and Limnology》 SCIE CAS CSCD 2011年第5期1093-1102,共10页
Among pharmaceuticals and personal care products released into the aquatic environment, antibiotics are of particular concern, because of their ubiquity and health effects. Although scientists have recently paid more ... Among pharmaceuticals and personal care products released into the aquatic environment, antibiotics are of particular concern, because of their ubiquity and health effects. Although scientists have recently paid more attention to the threat of antibiotics to coastal ecosystems, researchers have often focused on relatively few antibiotics, because of the absence of suitable analytical methods. We have therefore developed a method for the rapid detection of 36 antibiotic residues in coastal waters, including tetracyclines (TCs), sulfanilamides (SAs), and quinolones (QLs). The method consists of solid-phase extraction (SPE) and liquid chromatography-tandem mass spectrometry (LC-MS/MS) analysis, using electrospray ionization (ESI) in positive mode. The SPE was performed with Oasis HLB and Oasis MCX cartridges. Chromatographic separation on a C18 column was achieved using a binary eluent containing methanol and water with 0.1% formic acid. Typical recoveries of the analytes ranged from 67.4% to 109.3% at a fortification level of 100 ng/L. The precision of the method, calculated as relative standard deviation (RSD), was below 14.6% for all the compounds. The limits of detection (LODs) varied from 0.45 pg to 7.97 pg. The method was applied to determine the target analytes in coastal waters of the Yellow Sea in Liaoning, China. Among the tested antibiotics, 31 were found in coastal waters, with their concentrations between the LOD and 212.5 ng/L. These data indicate that this method is valid for analysis of antibiotics in coastal waters. The study first reports such a large number of antibiotics along the Yellow Sea coast of Liaoning, and should facilitate future comprehensive evaluation of antibiotics in coastal ecosystems. 展开更多
关键词 抗生素残留 高效液相色谱 沿海水域 质谱检测 串联质谱 LC-MS/MS 沿海生态系统 个人护理产品
下载PDF
Novel method for the determination of five carbamate pesticides in water samples by dispersive liquid-liquid microextraction combined with high performance liquid chromatography 被引量:10
20
作者 Zhi Mei Liu Xiao Huan Zang Wei Hua Liu Chun Wang Zhi Wang 《Chinese Chemical Letters》 SCIE CAS CSCD 2009年第2期213-216,共4页
A novel method for the determination of five carbamate pesticides(metolcarb,carbofuran,carbaryl,isoprocard and diethofencard)in water samples was developed by dispersive liquid-liquid microextraction(DLLME)coupled wit... A novel method for the determination of five carbamate pesticides(metolcarb,carbofuran,carbaryl,isoprocard and diethofencard)in water samples was developed by dispersive liquid-liquid microextraction(DLLME)coupled with high performance liquid chromatography-diode array detector(HPLC-DAD).Some experimental parameters that influence the extraction efficiency were studied and optimized to obtain the best extraction results.Under the optimum conditions for the method,the calibration curve was linear in the concentration range from 5 to 1000 ng mL^(-1)for all the five carbamate pesticides, with the correlation coefficients(r^2)varying from 0.9984 to 0.9994.Good enrichment factors were achieved ranging from 80 to 177- fold,depending on the compound.The limits of detection(LODs)(S/N=3)were ranged from 0.1 to 0.5 ng mL^(-1).The method has been successfully applied to the analysis of the pesticide residues in environmental water samples. 展开更多
关键词 氨基甲酸酯类农药 高效液相色谱法 环境水样 测定方法 分散液 萃取 二极管阵列检测器 提取效率
下载PDF
上一页 1 2 250 下一页 到第
使用帮助 返回顶部