期刊文献+
共找到2篇文章
< 1 >
每页显示 20 50 100
Quantitative Assessment of Right Ventricular Systolic Function by the Analysis of Right Ventricular Contrast Time-intensity Curve 被引量:2
1
作者 王林 邓又斌 +1 位作者 李天亮 杨好意 《Journal of Huazhong University of Science and Technology(Medical Sciences)》 SCIE CAS 2004年第6期607-609,共3页
Summary: To study reliability and reliable indices of quantitative assessment of right ventricular systolic function by time-intensity curve (TIC) with right ventricular contrast, 5 % sonicated human albumin was injec... Summary: To study reliability and reliable indices of quantitative assessment of right ventricular systolic function by time-intensity curve (TIC) with right ventricular contrast, 5 % sonicated human albumin was injected intravenously at a does of 0.08 ml/kg into 10 dogs at baseline status and cardiac insufficiency. Apical four-chamber view was observed for washin and washout of contrast agent from right ventricle. The parameters of TIC were obtained by curve fitting. The differences of parameters were analyzed in different states of cardiac functions. Among the parameters derived from TIC, the time constant (k) was decreased significantly with decline of cardiac function (P<0.001). But half-time of decent of peak intensity (HT) and mean-transit-time (MTT) of washout were increased significantly (P<0.001). The k was strongly related to cardiac output of right ventricle (CO) and ejection fraction (EF) of left ventricle and fractional shortening (FS) of left ventricle. Right ventricular systolic function could be assessed reliably by the parameters derived from TIC with right ventricular contrast echocardiography. The k, HT and MTT are reliable indices for quantitative assessment of right ventricular systolic function. 展开更多
关键词 time-intensity curve curve fitting right ventricular contrast right ventricular systolic function
下载PDF
Evaluation of Right Ventricular Volume and Systolic Function by Real-time Three-dimensional Echocardiography 被引量:4
2
作者 王静 王新房 +4 位作者 谢明星 杨娅 吕清 杨颖 王良玉 《Journal of Huazhong University of Science and Technology(Medical Sciences)》 SCIE CAS 2005年第1期94-96,99,共4页
The optimal plane for measurement of the right ventricular (RV) volumes by real-time three-dimensional echocardiography (RT3DE) was determined and the feasibility and accuracy of RT3DE in studying RV systolic function... The optimal plane for measurement of the right ventricular (RV) volumes by real-time three-dimensional echocardiography (RT3DE) was determined and the feasibility and accuracy of RT3DE in studying RV systolic function was assessed. RV “Full volume” images were acquired by RT3DE in 22 healthy subjects. RV end-diastolic volumes (RVEDV) and end-systolic volumes (RVESV) were outlined using apical biplane, 4-plane, 8-plane, 16-plane offline separately. RVSV and RVEF were calculated. Meanwhile tricuspid annual systolic excursion (TASE) was measured by M-mode echo. LVSV was outlined by 2-D echo according to the biplane Simpson's rule. The results showed: (1) There was a good correlation between RVSV measured from series planes and LVSV from 2-D echo (r=0.73; r=0.69; r=0.63; r=0.66, P<0.25—0.0025); (2) There were significant differences between RVEDV in biplane and those in 4-, 8-, 16-plane (P<0.001). There was also difference between RV volume in 4-plane and that in 8-plane (P<0.05), but there was no significant difference between RV volume in 8-plane and that in 16-plane (P>0.05); (3) Inter-observers and intro-observers variability analysis showed that there were close agreements and relations for RV volumes (r=0.986, P<0.001; r=0.93, P<0.001); (4) There was a significantly positive correlation of TASE to RVSV and RVEF from RT3DE (r=0.83; r=0.90). So RV volume measures with RT3DE are rapid, accurate and reproducible. In view of RV's complex shape, apical 8-plane method is better in clinical use. It may allow early detection of RV systolic function. 展开更多
关键词 real-time three-dimensional echocardiography right ventricular volume apical 8-plane right ventricular systolic function
下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部