期刊文献+
共找到4篇文章
< 1 >
每页显示 20 50 100
Ring artifacts correction based on the projection-field in neutron CT
1
作者 王声翔 陈洁 +6 位作者 谭志坚 邓司浩 吴耀达 卢怀乐 李守定 陈卫昌 何伦华 《Chinese Physics B》 SCIE EI CAS CSCD 2021年第5期267-271,共5页
Ring artifacts will happen mostly when the detector has inconsistent response among the detector channels,and the characteristic produced rings centered in the iso-center in the reconstructed slices inevitably affect ... Ring artifacts will happen mostly when the detector has inconsistent response among the detector channels,and the characteristic produced rings centered in the iso-center in the reconstructed slices inevitably affect the recognition and analysis of the corresponding sample structures in neutron computed tomography(CT).In this work,a ring correction method based on the projection-field(RCP)is proposed,it is a pre-processing method and provides the corrected projection data directly,which is also conducive to efficient data storage and other algorithmic researches.Simulation and physical experiments are performed for verifying the effect of the method,and one of the correction methods based on the image-field is used for comparison.The results demonstrate that the RCP can correct the ring artifacts well without reducing the image resolution or over-correction. 展开更多
关键词 ring artifacts correction neutron CT projection field
下载PDF
Ring artifacts removal in X-ray-induced acoustic computed tomography
2
作者 Prabodh Kumar Pandey Hari Om Aggrawal +3 位作者 Siqi Wang Kaitlyn Kim An Liu Liangzhong Xiang 《Journal of Innovative Optical Health Sciences》 SCIE EI CAS 2022年第3期54-69,共16页
X-ray-induced acoustic computed tomography(XACT)is a hybrid imaging modality for detecting X-ray absorption distribution via ultrasound emission.It facilitates imaging from a single projection X-ray illumination,thus ... X-ray-induced acoustic computed tomography(XACT)is a hybrid imaging modality for detecting X-ray absorption distribution via ultrasound emission.It facilitates imaging from a single projection X-ray illumination,thus reducing the radiation exposure and improving imaging speed.Nonuniform detector response caused by the interference between multichannel data acquisition for ring array transducers and amplifier systems yields ring artifacts in the reconstructed XACT images,which compromises the image quality.We propose model-based algorithms for ring artifacts corrected XACT imaging and demonstrate their effcacy on numerical and experimental measurements.The corrected reconstructions indicate significantly reduced ring artifacts as compared to their conventional counterparts. 展开更多
关键词 X-ray-induced acoustic computed tomography(XACT) ring artifacts artifacts correction
下载PDF
Multiscale anisotropic diffusion for ringing artifact suppression in geophysical deconvolution data
3
作者 Boxin Zuo Xiangyun Hu Meixia Geng 《Earthquake Science》 CSCD 2016年第4期215-220,共6页
Ringing artifact degradations always appear in the deconvolution of geophysical data. To address this problem, we propose a postprocessing approach to suppress ringing artifacts that uses a novel anisotropic diffusion... Ringing artifact degradations always appear in the deconvolution of geophysical data. To address this problem, we propose a postprocessing approach to suppress ringing artifacts that uses a novel anisotropic diffusion based on a stationary wavelet transform (SWT) algorithm. In this paper, we discuss the ringing artifact suppression problem and analyze the characteristics of the deconvolu- tion ringing artifact. The deconvolution data containing ringing artifacts are decomposed into different SWT sub- bands for analysis, and a new multiscale adaptive aniso- tropic filter is developed to suppress these degradations. Finally, we demonstrate the performance of the proposed method and describe the experiments in detail. 展开更多
关键词 DECONVOLUTION ringing artifacts Anisotropicdiffusion Stationary wavelet transform algorithm Multiscale
下载PDF
A deep learning-based ring artifact correctionmethod for X-ray CT 被引量:2
4
作者 Lulu Yuan Qiong Xu +4 位作者 Baodong Liu Zhe Wang Shuangquan Liu Cunfeng Wei Long Wei 《Radiation Detection Technology and Methods》 CSCD 2021年第4期493-503,共11页
Purpose In X-ray CT systems,ring artifacts caused by the nonuniform response of detector elements degrades the reconstruction quality and affects the subsequent processing and quantitative analysis of the image.Method... Purpose In X-ray CT systems,ring artifacts caused by the nonuniform response of detector elements degrades the reconstruction quality and affects the subsequent processing and quantitative analysis of the image.Method In this paper,a novel method is proposed to remove the ring artifacts in CT image by applying deep learning algorithm based on convolutional neural network(CNN)and recurrent neural network(RNN).First,the reconstructed CT images is transformed into polar coordinate system to make rings appear as stripes.Then,a CNN is constructed to detect the stripes,and a RNN is utilized to process the line artifact correction.After that,by retransforming the corrected image from polar coordinate system to Cartesian coordinate system,a ring artifact removal image can be achieved.Results The presented method can successfully reduce the CT ring artifact on simulated and real data.Specifically,in the experiment with real water phantom,the center and peripheral standard deviations reduced 46%and 24%,respectively.Conclusions The proposed method is potential to be widely deployed in industrial and medical CT systems,due to the excellent results on correction and the real-time performance without adjusting parameters manually. 展开更多
关键词 FPD-CT ring artifacts Deep learning CNN RNN
原文传递
上一页 1 下一页 到第