The methods of estimating the minimum allowed value of IFOV (instantaneous field of view) of the detector in a rosette scan system are investigated. The common method for the estimation of IFOV is described. A new met...The methods of estimating the minimum allowed value of IFOV (instantaneous field of view) of the detector in a rosette scan system are investigated. The common method for the estimation of IFOV is described. A new method which uses the maximum distance between two neighboring petals as the estimated value of IFOV is developed and a comparison between the common method and the new method is given. It is concluded that the minimum allowed value of IFOV of rosette scanning is over estimated by the common method while this value can be calculated accurately with the new method.展开更多
To restore the sub image in a rosette scanning system and provide target recognition system with a low distorted image, the sub image is processed with morphological filters. Morphological filter can process rosette...To restore the sub image in a rosette scanning system and provide target recognition system with a low distorted image, the sub image is processed with morphological filters. Morphological filter can process rosette scanning sub images more effectively. It can restore the original area and shape of an object effectively, and keep the energy information of the object. To process sub images got by a rosette scanning system, morphological filter is more effective than traditional low pass filter.展开更多
文摘The methods of estimating the minimum allowed value of IFOV (instantaneous field of view) of the detector in a rosette scan system are investigated. The common method for the estimation of IFOV is described. A new method which uses the maximum distance between two neighboring petals as the estimated value of IFOV is developed and a comparison between the common method and the new method is given. It is concluded that the minimum allowed value of IFOV of rosette scanning is over estimated by the common method while this value can be calculated accurately with the new method.
文摘To restore the sub image in a rosette scanning system and provide target recognition system with a low distorted image, the sub image is processed with morphological filters. Morphological filter can process rosette scanning sub images more effectively. It can restore the original area and shape of an object effectively, and keep the energy information of the object. To process sub images got by a rosette scanning system, morphological filter is more effective than traditional low pass filter.