Nowadays, PD (partial discharge) measurements are a crucial part of the preventive maintenance of electrical equipment within high voltage engineering. Especially for electrical machines, both the supplier and the u...Nowadays, PD (partial discharge) measurements are a crucial part of the preventive maintenance of electrical equipment within high voltage engineering. Especially for electrical machines, both the supplier and the user are interested in the results of PD measurements. However, PDs hardly represent the cause of the failure, more likely they are claimed as the outcome of a failure. This paper deals with the insulation of a 6 kV electrical machine, whereas PD measurements were carried out at a single stator from wound coils. During manufacturing, these coils were equipped with different materials for the OCP (outer corona protection). Using different PD measurement systems and different bandwidths, investigations of the PD behavior of the coils were carried out. Additionally, the surface resistivity of the corona protection was determined. As a result, conclusions for the correlations between the resistance of the OCP as well as the PD behavior are stated. Furthermore, the influence of using different measurement systems, different measuring circuits, and different bandwidths is shown.展开更多
A numerical-analytical method is applied for the two-dimensional magnetic field computation in rotational electric machines in this paper. The analytical expressions for air gap magnetic field are derived. The pole pa...A numerical-analytical method is applied for the two-dimensional magnetic field computation in rotational electric machines in this paper. The analytical expressions for air gap magnetic field are derived. The pole pairs in the expressions are taken into account so that the solution region can be reduced within one periodic range. The numerical and analytical magnetic field equations are linked with equal vector magnetic potential boundary conditions. The magnetic field of a brushless permanent magnet machine is computed by the proposed method. The result is compared to that obtained by finite element method so as to validate the correction of the method.展开更多
文摘Nowadays, PD (partial discharge) measurements are a crucial part of the preventive maintenance of electrical equipment within high voltage engineering. Especially for electrical machines, both the supplier and the user are interested in the results of PD measurements. However, PDs hardly represent the cause of the failure, more likely they are claimed as the outcome of a failure. This paper deals with the insulation of a 6 kV electrical machine, whereas PD measurements were carried out at a single stator from wound coils. During manufacturing, these coils were equipped with different materials for the OCP (outer corona protection). Using different PD measurement systems and different bandwidths, investigations of the PD behavior of the coils were carried out. Additionally, the surface resistivity of the corona protection was determined. As a result, conclusions for the correlations between the resistance of the OCP as well as the PD behavior are stated. Furthermore, the influence of using different measurement systems, different measuring circuits, and different bandwidths is shown.
文摘A numerical-analytical method is applied for the two-dimensional magnetic field computation in rotational electric machines in this paper. The analytical expressions for air gap magnetic field are derived. The pole pairs in the expressions are taken into account so that the solution region can be reduced within one periodic range. The numerical and analytical magnetic field equations are linked with equal vector magnetic potential boundary conditions. The magnetic field of a brushless permanent magnet machine is computed by the proposed method. The result is compared to that obtained by finite element method so as to validate the correction of the method.