An investigation on the ventral diverterless high offset S-shaped inlet is carried out at Mach numbers from 0.600 to 1.534, angles of attack from -4° to 9.4°, and yaw angles from 0° to 8°. Results ...An investigation on the ventral diverterless high offset S-shaped inlet is carried out at Mach numbers from 0.600 to 1.534, angles of attack from -4° to 9.4°, and yaw angles from 0° to 8°. Results indicate: (1) a large region of low total pressure exists at the lower part of the inlet exit caused by the counter-rotating vortices in the S-shaped duct; (2) the performances of the inlet at Mach number 1.000 reach almost the highest, so the propulsion system could work efficiently in terms of aerodynamics; (3) the total pressure recovery increases slowly at first and then remains unvaried as the Mach number rises from 0.6 to 1.0, however, it does in an opposite manner in the conventional diverter-equipped S-shaped inlet; (4) the performances of the inlet are generally insensitive to angles of attack from -4° to 9.4° and yaw angles from 0° to 8° at Mach number 0.850, and angles of attack from -2° to 6° and yaw angles from 0° to 5° at Mach number 1.534.展开更多
An electrohydrodynamic (EHD) method, which is based on glow discharge plasma, is presented for flow control in an S-shaped duct. The research subject is an expanding channel with a constant width and a rectangular c...An electrohydrodynamic (EHD) method, which is based on glow discharge plasma, is presented for flow control in an S-shaped duct. The research subject is an expanding channel with a constant width and a rectangular cross section. An equivalent divergence angle and basic function are introduced to build the three-dimensional model. Subsequently, the plasma physical models are simplified as the effects of electrical body force and work (done by the force) on the fluid near the wall. With the aid of FLUENT software, the source terms of momentum and energy are added to the Navier-Stokes equation. Finally, the original performance of three models (A, B and C) is studied, in which model A demonstrates better performance. Then EHD control based on model A is discussed. The results show that the EHD method is an effective way of reducing flow loss and improving uniformity at the duct exit. The innovation in this study is the assessment of the EHD control effect on the flow in an S-shaped duct. Both the parametric modeling of the S-shaped duct and the simplified models of plasma provide valuable information for future research on aircraft inlet ducts.展开更多
Testing-effort(TE) and imperfect debugging(ID) in the reliability modeling process may further improve the fitting and prediction results of software reliability growth models(SRGMs). For describing the S-shaped...Testing-effort(TE) and imperfect debugging(ID) in the reliability modeling process may further improve the fitting and prediction results of software reliability growth models(SRGMs). For describing the S-shaped varying trend of TE increasing rate more accurately, first, two S-shaped testing-effort functions(TEFs), i.e.,delayed S-shaped TEF(DS-TEF) and inflected S-shaped TEF(IS-TEF), are proposed. Then these two TEFs are incorporated into various types(exponential-type, delayed S-shaped and inflected S-shaped) of non-homogeneous Poisson process(NHPP)SRGMs with two forms of ID respectively for obtaining a series of new NHPP SRGMs which consider S-shaped TEFs as well as ID. Finally these new SRGMs and several comparison NHPP SRGMs are applied into four real failure data-sets respectively for investigating the fitting and prediction power of these new SRGMs.The experimental results show that:(i) the proposed IS-TEF is more suitable and flexible for describing the consumption of TE than the previous TEFs;(ii) incorporating TEFs into the inflected S-shaped NHPP SRGM may be more effective and appropriate compared with the exponential-type and the delayed S-shaped NHPP SRGMs;(iii) the inflected S-shaped NHPP SRGM considering both IS-TEF and ID yields the most accurate fitting and prediction results than the other comparison NHPP SRGMs.展开更多
Spalling of pillar ribs has been a major hazard in the mining industry for decades.In the absence of rib support guidelines,accidents have continued to occur in recent years.Developing effective support guidelines req...Spalling of pillar ribs has been a major hazard in the mining industry for decades.In the absence of rib support guidelines,accidents have continued to occur in recent years.Developing effective support guidelines requires a complete understanding of complex pillar damage mechanisms.Continuum models represent a convenient tool for analyzing this problem,but the behavior of such models is dependent of the choice of the constitutive model.In this study,a recently proposed constitutive model was used to simulate the rib fracturing process in a longwall chain pillar at West Cliff mine.After calibration,the model was able to capture the rib displacement profiles for multiple locations of the longwall face and the stress evolution 4 m into the pillar.The rib bolts in the model were found to be yielding over 60% of their length under the headgate loading condition.The model also predicted a steady damage accumulation in the rib for certain face locations,which is consistent with the description of the rib at the site.Damage was localized along the upper part of the pillar and underscored the role that the dirt band played in controlling rib deterioration at the site.The ability of the numerical model to replicate field measurements provides confidence in the capabilities of the new constitutive model.Finally,the need of using multi-point calibration is highlighted by comparing the results of the calibrated model to an alternative model calibrated to a smaller amount of data.展开更多
The simulation and analysis of S-shaped waveguide bend are presented.Bend radius larger than 30 mm assures less than 0.5 dB radiation loss for a 4-μm-wide silicon-on-insulator waveguide bend with 2-μm etch depth.Int...The simulation and analysis of S-shaped waveguide bend are presented.Bend radius larger than 30 mm assures less than 0.5 dB radiation loss for a 4-μm-wide silicon-on-insulator waveguide bend with 2-μm etch depth.Intersection angle greater than 20° provides negligible crosstalk (<-30 dB) and very low insertion loss.Any reduction in bend radius and intersection angle is at the cost of the degradation of characteristics of bent waveguide and intersecting waveguide, respectively.展开更多
This paper illustrates a simple kind of tri-band printed G-shaped monopole antenna for Multiple-Input-Multiple-Output (MIMO) systems. The proposed antenna is used to achieve three operating frequencies, 2.45 GHz, 5.2 ...This paper illustrates a simple kind of tri-band printed G-shaped monopole antenna for Multiple-Input-Multiple-Output (MIMO) systems. The proposed antenna is used to achieve three operating frequencies, 2.45 GHz, 5.2 GHz and 8.2 GHz for wireless communications. To improve the isolation between the two radiating elements, we use left-handed materials composed of only S-shaped resonators to get negative refractive index at the three operating frequencies. When one layer of S-shaped resonators is employed, the antenna correlation, the diversity gain and the bandwidth are also enhanced. The simulated results are presented and evaluated with and without left-handed materials.展开更多
Aim: the aim of this study was to investigate the shaping ability of thermomechanically treated files manufactured by twisting(Twisted files)and compare it to conventional rotary system (K3, Sybron Endo, Orange, CA) i...Aim: the aim of this study was to investigate the shaping ability of thermomechanically treated files manufactured by twisting(Twisted files)and compare it to conventional rotary system (K3, Sybron Endo, Orange, CA) in S-shaped canals, including formation of ledges, zipping, elbow, outer widening, danger zone, perforation and file deformation. Materials & Methods: Forty S-Shaped canals in resin blocks were randomly divided into 2 groups of 20 each. Pre-instrumentation images of the canals were taken via a digital camera and superimposed on images taken after preparation with TF and K3 systems to apical size of 25/06 and 30/06. Canal aberrations were measured from the superimposed image at five levels using AutoCAD system. Fisher exact test and Mann Whitney test were used for analysis of the data. Results: the incidence of zipping, elbow and apical transportation was significantly lower in the TF group (P = 0.04). Generally the incidence of aberration increased when the apical size increased to 30/0.06 regardless of the file system. Significant file deformation was evident in the TF after single use (P ? 0.001). Conclusion: Under the conditions of this study, TF manufactured by new technique performed better than K3 systems when used up to size 25/06 in simulated S-shaped canals. Clinical significance: The flexibility of thermomechanically treated files is beneficial in canals with multiple curvatures;however, attention should be paid to the instrument taper and final apical size of the preparation.展开更多
Amorphous–microcrystalline MoS_(2)thin films are fabricated using the sol-gel method to produce MoS_(2)/Si-based solar cells. The generation mechanisms of the S-shaped current density–voltage(J–V) curves of the sol...Amorphous–microcrystalline MoS_(2)thin films are fabricated using the sol-gel method to produce MoS_(2)/Si-based solar cells. The generation mechanisms of the S-shaped current density–voltage(J–V) curves of the solar cells are analyzed. To improve the performance of the solar cells and address the problem of the S-shaped J–V curve, a MoS_(2)film and a p^(+) layer are introduced into the front and back interfaces of the solar cell, respectively, which leads to the formation of a p–n junction between the p-Si and the MoS_(2)film as well as ohmic contacts between the MoS_(2)film and the ITO, improving the S-shaped J–V curve. As a result of the high doping characteristics and the high work function of the p^(+) layer, a high–low junction is formed between the p;and p layers along with ohmic contacts between the p;layer and the Ag electrode. Consequently,the S-shaped J–V curve is eliminated, and a significantly higher current density is achieved at a high voltage. The device exhibits ideal p–n junction rectification characteristics and achieves a high power-conversion efficiency(CE) of 7.55%. The findings of this study may improve the application of MoS_(2)thin films in silicon-based solar cells, which are expected to be widely used in various silicon-based electronic and optical devices.展开更多
During the production period of shale gas, proppant particles and rock debris are produced together,which will seriously erode the elbows of gathering pipelines. In response to this problem, this paper takes the elbow...During the production period of shale gas, proppant particles and rock debris are produced together,which will seriously erode the elbows of gathering pipelines. In response to this problem, this paper takes the elbow of the gathering pipeline in the Changning Shale Gas Field as an example to test the erosion rate and material removal mechanism of the test piece at different angles of the elbow through experiments and compares the four erosion models with the experimental results. Through analysis, it is found that the best prediction model for quartz sand-carbon steel erosion is the Oka model. Based on the Oka model, FLUENT software was used to simulate and analyze the law of erosion of the elbow of the gas gathering pipeline under different gas flow velocities, gas gathering pressure, particle size, length of L1,and bending directions of the elbow. And a spiral pipeline structure is proposed to reduce the erosion rate of the elbow under the same working conditions. The results show that this structure can reduce erosion by 34%.展开更多
Background: Elbow dislocations in pediatric patients are rare injuries. This is a therapeutic emergency because a delay in treatment can have disastrous consequences on the functional level of the upper limb. Objectiv...Background: Elbow dislocations in pediatric patients are rare injuries. This is a therapeutic emergency because a delay in treatment can have disastrous consequences on the functional level of the upper limb. Objective: To present the management of elbow dislocation in children in cases of limited resources. Presentation of the Cases: These were 2 older male children aged 7 and 9 years old, admitted to the emergency room for painful functional impotence of the right elbow after a fall and landing on the right hand. Clinical and radiological examinations were in favor of posterior elbow dislocations. The reductions were carried out under sedation and immobilization in Jersey. According to Robert’s criteria, the functional result was excellent in both patients. Conclusion: Emergency reduction and immobilization whatever the means ensure an excellent functional prognosis even in cases of limited resources.展开更多
BACKGROUND In recent years,the use of Magnesium alloy implants have gained renewed popularity,especially after the first commercially available ConformitéEuropéenne approved Magnesium implant became availabl...BACKGROUND In recent years,the use of Magnesium alloy implants have gained renewed popularity,especially after the first commercially available ConformitéEuropéenne approved Magnesium implant became available(MAGNEZIX®CS,Syntellix)in 2013.AIM To document our clinical and radiographical outcomes using magnesium implants in treating peri-articular elbow fractures.METHODS Our paper was based on a retrospective case series design.Intra-operatively,a standardized surgical technique was utilized for insertion of the magnesium implants.Post–operatively,clinic visits were standardized and physical exam findings,functional scores,and radiographs were obtained at each visit.All complications were recorded.RESULTS Five patients with 6 fractures were recruited(2 coronoid,3 radial head and 1 capitellum).The mean patient age and length of follow up was 54.6 years and 11 months respectively.All fractures healed,and none exhibited loss of reduction or complications requiring revision surgery.No patient developed synovitis of the elbow joint or suffered electrolytic reactions when titanium implants were used concurrently.CONCLUSION Although there is still a paucity of literature available on the subject and further studies are required,magnesium implants appear to be a feasible tool for fixation of peri-articular elbow fractures with promising results in our series.INTRODUCTION In recent years,the use of Magnesium alloy implants in orthopaedic surgeries have gained renewed popularity.Apart from being bioabsorbable,negating the need for implant removal,magnesium also has good osteoconductive properties[1-4].Biomechanically,it exhibits greater biomechanical strength than any pre-existing polymers,and reduces the stress-shielding effect associated with titanium and steel implants as it has a Young’s modulus closer to bone[4].Currently,the main utility of magnesium implants in the orthopaedic community is within the foot and ankle community where satisfactory results have been reported with its utility in forefoot osteotomies[5-7].However,its utility in the setting of orthopaedic trauma has been steadily increasing[8].Our study aims to document our clinical and radiographical outcomes using magnesium implants to treat peri-articular elbow fractures.To our knowledge,our study is the first study analyzing outcomes in radial head and coronoid fractures in the English literature.展开更多
BACKGROUND Due to frequent and high-risk sports activities,the elbow joint is susceptible to injury,especially to cartilage tissue,which can cause pain,limited movement and even loss of joint function.AIM To evaluate ...BACKGROUND Due to frequent and high-risk sports activities,the elbow joint is susceptible to injury,especially to cartilage tissue,which can cause pain,limited movement and even loss of joint function.AIM To evaluate magnetic resonance imaging(MRI)multisequence imaging for improving the diagnostic accuracy of adult elbow cartilage injury.METHODS A total of 60 patients diagnosed with elbow cartilage injury in our hospital from January 2020 to December 2021 were enrolled in this retrospective study.We analyzed the accuracy of conventional MRI sequences(T1-weighted imaging,T2-weighted imaging,proton density weighted imaging,and T2 star weighted image)and Three-Dimensional Coronary Imaging by Spiral Scanning(3D-CISS)in the diagnosis of elbow cartilage injury.Arthroscopy was used as the gold standard to evaluate the diagnostic effect of single and combination sequences in different injury degrees and the consistency with arthroscopy.RESULTS The diagnostic accuracy of 3D-CISS sequence was 89.34%±4.98%,the sensitivity was 90%,and the specificity was 88.33%,which showed the best performance among all sequences(P<0.05).The combined application of the whole sequence had the highest accuracy in all sequence combinations,the accuracy of mild injury was 91.30%,the accuracy of moderate injury was 96.15%,and the accuracy of severe injury was 93.33%(P<0.05).Compared with arthroscopy,the combination of all MRI sequences had the highest consistency of 91.67%,and the kappa value reached 0.890(P<0.001).CONCLUSION Combination of 3D-CISS and each sequence had significant advantages in improving MRI diagnostic accuracy of elbow cartilage injuries in adults.Multisequence MRI is recommended to ensure the best diagnosis and treatment.展开更多
Introduction: The elbow is a superficial joint, particularly exposed to direct impact, forced movement, and overstrain. Our work aimed to study magnetic resonance imaging (MRI) pathologies of the soft tissues of the e...Introduction: The elbow is a superficial joint, particularly exposed to direct impact, forced movement, and overstrain. Our work aimed to study magnetic resonance imaging (MRI) pathologies of the soft tissues of the elbow through illustrative cases. Methodology: This was a retrospective and prospective cross-sectional study covering a period of one year, from June 2020 to June 2021, at the Saint Camille Hospital in Ouagadougou and the Polyclinique Notre Dame de la Paix. Results: In general, this study found that the pathologies diagnosed on MRI were lateral epicondylitis, subcutaneous type V elbow lipoma and liposarcoma, anteromedial cortical fracture of the radial cup, cortical detachment fracture of the lateral epicondylitis, medial epicondylitis, villonodular articular synovitis, simple dermo-hypodermatitis, sequellar fibrosis of the ulnar nerve, Workman's syndrome (median and ulnar nerves) and osteoarthritis of the elbow. Lateral epicondylitis was the most frequent pathology, and most patients consulted for elbow pain predominantly associated with pressure on the epicondyle, with relative functional impotence and, occasionally, elbow swelling. Conclusion: MRI, as a complement to ultrasound and radiography, remains the most informative examination for exploring soft-tissue pathologies of the elbow.展开更多
A loop system was used to investigate the effect of flow velocity on corrosion behavior of AZ91 D magnesium alloy at an elbow of loop system based on array electrode technology by polarization, computational fluid dyn...A loop system was used to investigate the effect of flow velocity on corrosion behavior of AZ91 D magnesium alloy at an elbow of loop system based on array electrode technology by polarization, computational fluid dynamics(CFD) simulation and surface analysis. The experimental results showed that the corrosion rate increased with increasing flow velocity, and a critical flow velocity could exist in the corrosion of AZ91 D magnesium alloy. When flow velocity exceeded the critical flow velocity, fluid hydrodynamics was dominant in the corrosion of AZ91 D magnesium alloy. On the contrary, the electrochemical factors were dominant.展开更多
AIM:To evaluate short-to medium term outcome of total elbow arthroplasty(TEA)in complex fractures of the distal humerus.METHODS:A consecutive series of 24 complex distal humerus fractures operated with TEA in the peri...AIM:To evaluate short-to medium term outcome of total elbow arthroplasty(TEA)in complex fractures of the distal humerus.METHODS:A consecutive series of 24 complex distal humerus fractures operated with TEA in the period2006-2012 was evaluated with the Mayo Elbow Performance score(MEPS),plain radiographs,complications and overall satisfaction.The indications for surgery were 1:AO type B3 or C3 or Sheffield type 3 fracture and age above 65 or 2:fracture and severe rheumatoid arthritis.Mean follow-up time was 21 mo.RESULTS:Twenty patients were followed up.Four patients,of which 3 had died,were lost to follow up.According to the AO classification there were 17 C3,1B2 and 2 A2 fractures.Mean follow-up was 21 months(range 4-54).Mean MEPS was 94(range 65-100).Mean flexion was 114 degrees(range 80-140).According to MEPS there were 15 excellent,4 good and 1 fair result.Patient satisfaction:8 excellent,10 good,2 fair and 1poor.There were two revisions due to infection treated successfully with revision and three months of antibiotics.In two patients the locking split had loosened.One was referred to re-insertion and one chose yearly con-trols.Two patients had persistent dysaesthesia of their5th finger,but were able to discriminate between sharp and blunt.CONCLUSION:Our study suggests that TEA in complex fractures of the distal humerus in elderly patients can result in acceptable short-to medium term outcome.展开更多
Lateral epicondylitis is a relatively common clinical prob lem, easily recognized on palpation of the lateral protu berance on the elbow. Despite the "itis" suffix, it is no an inflammatory process. Therapeu...Lateral epicondylitis is a relatively common clinical prob lem, easily recognized on palpation of the lateral protu berance on the elbow. Despite the "itis" suffix, it is no an inflammatory process. Therapeutic approaches with topical non-steroidal anti-inflammatory drugs, cortico steroids and anesthetics have limited benefit, as would be expected if inflammation is not involved. Other ap proaches have included provision of healing cytokine from blood products or stem cells, based on the recog nition that this repetitive effort-derived disorder repre sents injury. Noting calcification/ossification of tendon attachments to the lateral epicondyle(enthesitis), dry needling, radiofrequency, shock wave treatments and surgical approaches have also been pursued. Physi ologic approaches, including manipulation, therapeuti ultrasound, phonophoresis, iontophoresis, acupuncture and exposure of the area to low level laser light, ha also had limited success. This contrasts with the benefi of a simple mechanical intervention, reducing the stres on the attachment area. This is based on displacemen of the stress by use of a thin(3/4-1 inch) band applied just distal to the epicondyle. Thin bands are required as thick bands(e.g., 2-3 inch wide) simply reduce mus cle strength, without significantly reducing stress. Thi approach appears to be associated with a failure rateless than 1%, assuming the afflicted individual modifies the activity that repeatedly stresses the epicondylar attachments.展开更多
The medial ulnar collateral ligament complex of the elbow, which is comprised of the anterior bundle [AB, more formally referred to as the medial ulnar collateral ligament(MUCL)], posterior(PB), and transverse ligamen...The medial ulnar collateral ligament complex of the elbow, which is comprised of the anterior bundle [AB, more formally referred to as the medial ulnar collateral ligament(MUCL)], posterior(PB), and transverse ligament, is commonly injured in overhead throwing athletes. Attenuation or rupture of the ligament results in valgus instability with variable clinical presentations. The AB or MUCL is the strongest component of the ligamentous complex and the primary restraint to valgus stress. It is also composed of two separate bands(anterior and posterior) that provide reciprocal function with the anterior band tight in extension, and the posterior band tight in flexion. In individuals who fail co-mprehensive non-operative treatment, surgical repair or reconstruction of the MUCL is commonly required to restore elbow function and stability. A comprehensive understanding of the anatomy and biomechanical properties of the MUCL is imperative to optimize reconstructive efforts, and to enhance clinical and radiographic outcomes. Our understanding of the native anatomy and biomechanics of the MUCL has evolved over time. The precise locations of the origin and insertion footprint centers guide surgeons in proper graft placement with relation to bony anatomic landmarks. In recent studies, the ulnar insertion of the MUCL is described as larger than previously thought, with the center of the footprint at varying distances relative to the ulnar ridge, joint line, or sublime tubercle. The purpose of this review is to consolidate and summarize the existing literature regarding the native anatomy, biomechanical, and clinical significance of the entire medial ulnar collateral ligament complex, including the MUCL(AB), PB, and transverse ligament.展开更多
With the increase in mining depth, mine heat harm has appeared to be more prominent. The mine heat harm could be resolvedor reduced by ice refrigeration. Thus, ice transportation through pipeline becomes a critical pr...With the increase in mining depth, mine heat harm has appeared to be more prominent. The mine heat harm could be resolvedor reduced by ice refrigeration. Thus, ice transportation through pipeline becomes a critical problem; typically flowresistance occurs in the elbow. In the present study, according to the analysis of the surface morphology of fish scale, abiomimetic functional surface structure for the interior wall of elbow is designed. Based on the theory of liquid-solid two phaseflow, a CFD numerical simulation of ice-water mixture flowing through the elbow is carried out using finite element method.Conventional experiments of pressure drop and flow resistance for both bionic and common elbows are conducted to test theeffect of the bionic elbow on flow resistance reduction. It is found that with the increase in the ice mass fraction in the ice-watermixture, the effect of bionic elbow on resistance reduction becomes more obvious.展开更多
The elbow joint is a complex joint, which, when impaired in function, leads to severe disability. In some cases however, an arthroplasty might be an appropriate treatment. In the past four decades, large steps havebee...The elbow joint is a complex joint, which, when impaired in function, leads to severe disability. In some cases however, an arthroplasty might be an appropriate treatment. In the past four decades, large steps havebeen taken to optimize this treatment in order to achieve better post-operative outcomes. To understand these progresses and to discover aspects for upcoming improvements, we present a review on the past developments, the present state of affairs and future developments which may improve patient care further.展开更多
基金National Basic Research Program of China (5130802)
文摘An investigation on the ventral diverterless high offset S-shaped inlet is carried out at Mach numbers from 0.600 to 1.534, angles of attack from -4° to 9.4°, and yaw angles from 0° to 8°. Results indicate: (1) a large region of low total pressure exists at the lower part of the inlet exit caused by the counter-rotating vortices in the S-shaped duct; (2) the performances of the inlet at Mach number 1.000 reach almost the highest, so the propulsion system could work efficiently in terms of aerodynamics; (3) the total pressure recovery increases slowly at first and then remains unvaried as the Mach number rises from 0.6 to 1.0, however, it does in an opposite manner in the conventional diverter-equipped S-shaped inlet; (4) the performances of the inlet are generally insensitive to angles of attack from -4° to 9.4° and yaw angles from 0° to 8° at Mach number 0.850, and angles of attack from -2° to 6° and yaw angles from 0° to 5° at Mach number 1.534.
文摘An electrohydrodynamic (EHD) method, which is based on glow discharge plasma, is presented for flow control in an S-shaped duct. The research subject is an expanding channel with a constant width and a rectangular cross section. An equivalent divergence angle and basic function are introduced to build the three-dimensional model. Subsequently, the plasma physical models are simplified as the effects of electrical body force and work (done by the force) on the fluid near the wall. With the aid of FLUENT software, the source terms of momentum and energy are added to the Navier-Stokes equation. Finally, the original performance of three models (A, B and C) is studied, in which model A demonstrates better performance. Then EHD control based on model A is discussed. The results show that the EHD method is an effective way of reducing flow loss and improving uniformity at the duct exit. The innovation in this study is the assessment of the EHD control effect on the flow in an S-shaped duct. Both the parametric modeling of the S-shaped duct and the simplified models of plasma provide valuable information for future research on aircraft inlet ducts.
基金supported by the Pre-research Foundation of CPLA General Equipment Department
文摘Testing-effort(TE) and imperfect debugging(ID) in the reliability modeling process may further improve the fitting and prediction results of software reliability growth models(SRGMs). For describing the S-shaped varying trend of TE increasing rate more accurately, first, two S-shaped testing-effort functions(TEFs), i.e.,delayed S-shaped TEF(DS-TEF) and inflected S-shaped TEF(IS-TEF), are proposed. Then these two TEFs are incorporated into various types(exponential-type, delayed S-shaped and inflected S-shaped) of non-homogeneous Poisson process(NHPP)SRGMs with two forms of ID respectively for obtaining a series of new NHPP SRGMs which consider S-shaped TEFs as well as ID. Finally these new SRGMs and several comparison NHPP SRGMs are applied into four real failure data-sets respectively for investigating the fitting and prediction power of these new SRGMs.The experimental results show that:(i) the proposed IS-TEF is more suitable and flexible for describing the consumption of TE than the previous TEFs;(ii) incorporating TEFs into the inflected S-shaped NHPP SRGM may be more effective and appropriate compared with the exponential-type and the delayed S-shaped NHPP SRGMs;(iii) the inflected S-shaped NHPP SRGM considering both IS-TEF and ID yields the most accurate fitting and prediction results than the other comparison NHPP SRGMs.
基金funded by the National Institute for Occupational Safety and Health(NIOSH)(Grant No.200-2016-90154)sponsored by the Alpha Foundation for the Improvement of Mine Safety and Health,Inc.(ALPHA FOUNDATION)。
文摘Spalling of pillar ribs has been a major hazard in the mining industry for decades.In the absence of rib support guidelines,accidents have continued to occur in recent years.Developing effective support guidelines requires a complete understanding of complex pillar damage mechanisms.Continuum models represent a convenient tool for analyzing this problem,but the behavior of such models is dependent of the choice of the constitutive model.In this study,a recently proposed constitutive model was used to simulate the rib fracturing process in a longwall chain pillar at West Cliff mine.After calibration,the model was able to capture the rib displacement profiles for multiple locations of the longwall face and the stress evolution 4 m into the pillar.The rib bolts in the model were found to be yielding over 60% of their length under the headgate loading condition.The model also predicted a steady damage accumulation in the rib for certain face locations,which is consistent with the description of the rib at the site.Damage was localized along the upper part of the pillar and underscored the role that the dirt band played in controlling rib deterioration at the site.The ability of the numerical model to replicate field measurements provides confidence in the capabilities of the new constitutive model.Finally,the need of using multi-point calibration is highlighted by comparing the results of the calibrated model to an alternative model calibrated to a smaller amount of data.
文摘The simulation and analysis of S-shaped waveguide bend are presented.Bend radius larger than 30 mm assures less than 0.5 dB radiation loss for a 4-μm-wide silicon-on-insulator waveguide bend with 2-μm etch depth.Intersection angle greater than 20° provides negligible crosstalk (<-30 dB) and very low insertion loss.Any reduction in bend radius and intersection angle is at the cost of the degradation of characteristics of bent waveguide and intersecting waveguide, respectively.
文摘This paper illustrates a simple kind of tri-band printed G-shaped monopole antenna for Multiple-Input-Multiple-Output (MIMO) systems. The proposed antenna is used to achieve three operating frequencies, 2.45 GHz, 5.2 GHz and 8.2 GHz for wireless communications. To improve the isolation between the two radiating elements, we use left-handed materials composed of only S-shaped resonators to get negative refractive index at the three operating frequencies. When one layer of S-shaped resonators is employed, the antenna correlation, the diversity gain and the bandwidth are also enhanced. The simulated results are presented and evaluated with and without left-handed materials.
文摘Aim: the aim of this study was to investigate the shaping ability of thermomechanically treated files manufactured by twisting(Twisted files)and compare it to conventional rotary system (K3, Sybron Endo, Orange, CA) in S-shaped canals, including formation of ledges, zipping, elbow, outer widening, danger zone, perforation and file deformation. Materials & Methods: Forty S-Shaped canals in resin blocks were randomly divided into 2 groups of 20 each. Pre-instrumentation images of the canals were taken via a digital camera and superimposed on images taken after preparation with TF and K3 systems to apical size of 25/06 and 30/06. Canal aberrations were measured from the superimposed image at five levels using AutoCAD system. Fisher exact test and Mann Whitney test were used for analysis of the data. Results: the incidence of zipping, elbow and apical transportation was significantly lower in the TF group (P = 0.04). Generally the incidence of aberration increased when the apical size increased to 30/0.06 regardless of the file system. Significant file deformation was evident in the TF after single use (P ? 0.001). Conclusion: Under the conditions of this study, TF manufactured by new technique performed better than K3 systems when used up to size 25/06 in simulated S-shaped canals. Clinical significance: The flexibility of thermomechanically treated files is beneficial in canals with multiple curvatures;however, attention should be paid to the instrument taper and final apical size of the preparation.
基金Project supported by the Science and Technology Research Project of Hebei Province Colleges and Universities (Grant No. QN2020113)Tangshan Applied Basic Research Project (Grant No. 19130227g)。
文摘Amorphous–microcrystalline MoS_(2)thin films are fabricated using the sol-gel method to produce MoS_(2)/Si-based solar cells. The generation mechanisms of the S-shaped current density–voltage(J–V) curves of the solar cells are analyzed. To improve the performance of the solar cells and address the problem of the S-shaped J–V curve, a MoS_(2)film and a p^(+) layer are introduced into the front and back interfaces of the solar cell, respectively, which leads to the formation of a p–n junction between the p-Si and the MoS_(2)film as well as ohmic contacts between the MoS_(2)film and the ITO, improving the S-shaped J–V curve. As a result of the high doping characteristics and the high work function of the p^(+) layer, a high–low junction is formed between the p;and p layers along with ohmic contacts between the p;layer and the Ag electrode. Consequently,the S-shaped J–V curve is eliminated, and a significantly higher current density is achieved at a high voltage. The device exhibits ideal p–n junction rectification characteristics and achieves a high power-conversion efficiency(CE) of 7.55%. The findings of this study may improve the application of MoS_(2)thin films in silicon-based solar cells, which are expected to be widely used in various silicon-based electronic and optical devices.
基金supported by the Petrochina's “14th Five-Year plan” Project(2021DJ2804)Sichuan Natural Science Foundation(2023NSFSC0422)。
文摘During the production period of shale gas, proppant particles and rock debris are produced together,which will seriously erode the elbows of gathering pipelines. In response to this problem, this paper takes the elbow of the gathering pipeline in the Changning Shale Gas Field as an example to test the erosion rate and material removal mechanism of the test piece at different angles of the elbow through experiments and compares the four erosion models with the experimental results. Through analysis, it is found that the best prediction model for quartz sand-carbon steel erosion is the Oka model. Based on the Oka model, FLUENT software was used to simulate and analyze the law of erosion of the elbow of the gas gathering pipeline under different gas flow velocities, gas gathering pressure, particle size, length of L1,and bending directions of the elbow. And a spiral pipeline structure is proposed to reduce the erosion rate of the elbow under the same working conditions. The results show that this structure can reduce erosion by 34%.
文摘Background: Elbow dislocations in pediatric patients are rare injuries. This is a therapeutic emergency because a delay in treatment can have disastrous consequences on the functional level of the upper limb. Objective: To present the management of elbow dislocation in children in cases of limited resources. Presentation of the Cases: These were 2 older male children aged 7 and 9 years old, admitted to the emergency room for painful functional impotence of the right elbow after a fall and landing on the right hand. Clinical and radiological examinations were in favor of posterior elbow dislocations. The reductions were carried out under sedation and immobilization in Jersey. According to Robert’s criteria, the functional result was excellent in both patients. Conclusion: Emergency reduction and immobilization whatever the means ensure an excellent functional prognosis even in cases of limited resources.
文摘BACKGROUND In recent years,the use of Magnesium alloy implants have gained renewed popularity,especially after the first commercially available ConformitéEuropéenne approved Magnesium implant became available(MAGNEZIX®CS,Syntellix)in 2013.AIM To document our clinical and radiographical outcomes using magnesium implants in treating peri-articular elbow fractures.METHODS Our paper was based on a retrospective case series design.Intra-operatively,a standardized surgical technique was utilized for insertion of the magnesium implants.Post–operatively,clinic visits were standardized and physical exam findings,functional scores,and radiographs were obtained at each visit.All complications were recorded.RESULTS Five patients with 6 fractures were recruited(2 coronoid,3 radial head and 1 capitellum).The mean patient age and length of follow up was 54.6 years and 11 months respectively.All fractures healed,and none exhibited loss of reduction or complications requiring revision surgery.No patient developed synovitis of the elbow joint or suffered electrolytic reactions when titanium implants were used concurrently.CONCLUSION Although there is still a paucity of literature available on the subject and further studies are required,magnesium implants appear to be a feasible tool for fixation of peri-articular elbow fractures with promising results in our series.INTRODUCTION In recent years,the use of Magnesium alloy implants in orthopaedic surgeries have gained renewed popularity.Apart from being bioabsorbable,negating the need for implant removal,magnesium also has good osteoconductive properties[1-4].Biomechanically,it exhibits greater biomechanical strength than any pre-existing polymers,and reduces the stress-shielding effect associated with titanium and steel implants as it has a Young’s modulus closer to bone[4].Currently,the main utility of magnesium implants in the orthopaedic community is within the foot and ankle community where satisfactory results have been reported with its utility in forefoot osteotomies[5-7].However,its utility in the setting of orthopaedic trauma has been steadily increasing[8].Our study aims to document our clinical and radiographical outcomes using magnesium implants to treat peri-articular elbow fractures.To our knowledge,our study is the first study analyzing outcomes in radial head and coronoid fractures in the English literature.
文摘BACKGROUND Due to frequent and high-risk sports activities,the elbow joint is susceptible to injury,especially to cartilage tissue,which can cause pain,limited movement and even loss of joint function.AIM To evaluate magnetic resonance imaging(MRI)multisequence imaging for improving the diagnostic accuracy of adult elbow cartilage injury.METHODS A total of 60 patients diagnosed with elbow cartilage injury in our hospital from January 2020 to December 2021 were enrolled in this retrospective study.We analyzed the accuracy of conventional MRI sequences(T1-weighted imaging,T2-weighted imaging,proton density weighted imaging,and T2 star weighted image)and Three-Dimensional Coronary Imaging by Spiral Scanning(3D-CISS)in the diagnosis of elbow cartilage injury.Arthroscopy was used as the gold standard to evaluate the diagnostic effect of single and combination sequences in different injury degrees and the consistency with arthroscopy.RESULTS The diagnostic accuracy of 3D-CISS sequence was 89.34%±4.98%,the sensitivity was 90%,and the specificity was 88.33%,which showed the best performance among all sequences(P<0.05).The combined application of the whole sequence had the highest accuracy in all sequence combinations,the accuracy of mild injury was 91.30%,the accuracy of moderate injury was 96.15%,and the accuracy of severe injury was 93.33%(P<0.05).Compared with arthroscopy,the combination of all MRI sequences had the highest consistency of 91.67%,and the kappa value reached 0.890(P<0.001).CONCLUSION Combination of 3D-CISS and each sequence had significant advantages in improving MRI diagnostic accuracy of elbow cartilage injuries in adults.Multisequence MRI is recommended to ensure the best diagnosis and treatment.
文摘Introduction: The elbow is a superficial joint, particularly exposed to direct impact, forced movement, and overstrain. Our work aimed to study magnetic resonance imaging (MRI) pathologies of the soft tissues of the elbow through illustrative cases. Methodology: This was a retrospective and prospective cross-sectional study covering a period of one year, from June 2020 to June 2021, at the Saint Camille Hospital in Ouagadougou and the Polyclinique Notre Dame de la Paix. Results: In general, this study found that the pathologies diagnosed on MRI were lateral epicondylitis, subcutaneous type V elbow lipoma and liposarcoma, anteromedial cortical fracture of the radial cup, cortical detachment fracture of the lateral epicondylitis, medial epicondylitis, villonodular articular synovitis, simple dermo-hypodermatitis, sequellar fibrosis of the ulnar nerve, Workman's syndrome (median and ulnar nerves) and osteoarthritis of the elbow. Lateral epicondylitis was the most frequent pathology, and most patients consulted for elbow pain predominantly associated with pressure on the epicondyle, with relative functional impotence and, occasionally, elbow swelling. Conclusion: MRI, as a complement to ultrasound and radiography, remains the most informative examination for exploring soft-tissue pathologies of the elbow.
基金Project(51401151)supported by the National Natural Science Foundation of ChinaProjects(2015T80792,2012M511207)supported by the Postdoctoral Science Foundation of China
文摘A loop system was used to investigate the effect of flow velocity on corrosion behavior of AZ91 D magnesium alloy at an elbow of loop system based on array electrode technology by polarization, computational fluid dynamics(CFD) simulation and surface analysis. The experimental results showed that the corrosion rate increased with increasing flow velocity, and a critical flow velocity could exist in the corrosion of AZ91 D magnesium alloy. When flow velocity exceeded the critical flow velocity, fluid hydrodynamics was dominant in the corrosion of AZ91 D magnesium alloy. On the contrary, the electrochemical factors were dominant.
文摘AIM:To evaluate short-to medium term outcome of total elbow arthroplasty(TEA)in complex fractures of the distal humerus.METHODS:A consecutive series of 24 complex distal humerus fractures operated with TEA in the period2006-2012 was evaluated with the Mayo Elbow Performance score(MEPS),plain radiographs,complications and overall satisfaction.The indications for surgery were 1:AO type B3 or C3 or Sheffield type 3 fracture and age above 65 or 2:fracture and severe rheumatoid arthritis.Mean follow-up time was 21 mo.RESULTS:Twenty patients were followed up.Four patients,of which 3 had died,were lost to follow up.According to the AO classification there were 17 C3,1B2 and 2 A2 fractures.Mean follow-up was 21 months(range 4-54).Mean MEPS was 94(range 65-100).Mean flexion was 114 degrees(range 80-140).According to MEPS there were 15 excellent,4 good and 1 fair result.Patient satisfaction:8 excellent,10 good,2 fair and 1poor.There were two revisions due to infection treated successfully with revision and three months of antibiotics.In two patients the locking split had loosened.One was referred to re-insertion and one chose yearly con-trols.Two patients had persistent dysaesthesia of their5th finger,but were able to discriminate between sharp and blunt.CONCLUSION:Our study suggests that TEA in complex fractures of the distal humerus in elderly patients can result in acceptable short-to medium term outcome.
文摘Lateral epicondylitis is a relatively common clinical prob lem, easily recognized on palpation of the lateral protu berance on the elbow. Despite the "itis" suffix, it is no an inflammatory process. Therapeutic approaches with topical non-steroidal anti-inflammatory drugs, cortico steroids and anesthetics have limited benefit, as would be expected if inflammation is not involved. Other ap proaches have included provision of healing cytokine from blood products or stem cells, based on the recog nition that this repetitive effort-derived disorder repre sents injury. Noting calcification/ossification of tendon attachments to the lateral epicondyle(enthesitis), dry needling, radiofrequency, shock wave treatments and surgical approaches have also been pursued. Physi ologic approaches, including manipulation, therapeuti ultrasound, phonophoresis, iontophoresis, acupuncture and exposure of the area to low level laser light, ha also had limited success. This contrasts with the benefi of a simple mechanical intervention, reducing the stres on the attachment area. This is based on displacemen of the stress by use of a thin(3/4-1 inch) band applied just distal to the epicondyle. Thin bands are required as thick bands(e.g., 2-3 inch wide) simply reduce mus cle strength, without significantly reducing stress. Thi approach appears to be associated with a failure rateless than 1%, assuming the afflicted individual modifies the activity that repeatedly stresses the epicondylar attachments.
文摘The medial ulnar collateral ligament complex of the elbow, which is comprised of the anterior bundle [AB, more formally referred to as the medial ulnar collateral ligament(MUCL)], posterior(PB), and transverse ligament, is commonly injured in overhead throwing athletes. Attenuation or rupture of the ligament results in valgus instability with variable clinical presentations. The AB or MUCL is the strongest component of the ligamentous complex and the primary restraint to valgus stress. It is also composed of two separate bands(anterior and posterior) that provide reciprocal function with the anterior band tight in extension, and the posterior band tight in flexion. In individuals who fail co-mprehensive non-operative treatment, surgical repair or reconstruction of the MUCL is commonly required to restore elbow function and stability. A comprehensive understanding of the anatomy and biomechanical properties of the MUCL is imperative to optimize reconstructive efforts, and to enhance clinical and radiographic outcomes. Our understanding of the native anatomy and biomechanics of the MUCL has evolved over time. The precise locations of the origin and insertion footprint centers guide surgeons in proper graft placement with relation to bony anatomic landmarks. In recent studies, the ulnar insertion of the MUCL is described as larger than previously thought, with the center of the footprint at varying distances relative to the ulnar ridge, joint line, or sublime tubercle. The purpose of this review is to consolidate and summarize the existing literature regarding the native anatomy, biomechanical, and clinical significance of the entire medial ulnar collateral ligament complex, including the MUCL(AB), PB, and transverse ligament.
基金supported bv the National Natural Science Foundation of China(Grant No.50975164)the Science and Technology Planning Project of Shandong Proyince(Grant No.J09LD05)the Foundation of Key LaboratOry of Mine Hazard Prevention and Control (Grant No.MDPC0810)
文摘With the increase in mining depth, mine heat harm has appeared to be more prominent. The mine heat harm could be resolvedor reduced by ice refrigeration. Thus, ice transportation through pipeline becomes a critical problem; typically flowresistance occurs in the elbow. In the present study, according to the analysis of the surface morphology of fish scale, abiomimetic functional surface structure for the interior wall of elbow is designed. Based on the theory of liquid-solid two phaseflow, a CFD numerical simulation of ice-water mixture flowing through the elbow is carried out using finite element method.Conventional experiments of pressure drop and flow resistance for both bionic and common elbows are conducted to test theeffect of the bionic elbow on flow resistance reduction. It is found that with the increase in the ice mass fraction in the ice-watermixture, the effect of bionic elbow on resistance reduction becomes more obvious.
文摘The elbow joint is a complex joint, which, when impaired in function, leads to severe disability. In some cases however, an arthroplasty might be an appropriate treatment. In the past four decades, large steps havebeen taken to optimize this treatment in order to achieve better post-operative outcomes. To understand these progresses and to discover aspects for upcoming improvements, we present a review on the past developments, the present state of affairs and future developments which may improve patient care further.