The prototype fast breeder reactor "MONJU" has an EVSS (ex-vessel fuel storage system) which consists mainly of an EVST (ex-vessel fuel storage tank) and an EVST sodium cooling system. EVST sodium cooling system...The prototype fast breeder reactor "MONJU" has an EVSS (ex-vessel fuel storage system) which consists mainly of an EVST (ex-vessel fuel storage tank) and an EVST sodium cooling system. EVST sodium cooling system consists of three independent loops. During the normal operation, the primary sodium in the EVST is circulated by natural convection and the secondary circulation in the EVST sodium cooling system is powered by electromagnetic pumps. When an SBO (station blackout) occurs, all the pumps and blowers are tripped. Therefore, it was necessary to evaluate the cooling ability by the natural circulation of sodium in the EVST sodium cooling system and air through the air cooler during the SBO. In this study, an analysis and evaluation of the plant dynamics for the spent fuel and the EVSS structural integrity during an SBO were performed. When the number of cooling loops was not changed and natural circulation occurred in only two loops, the sodium temperature in the EVST increased to approximately 450 ~C. However, the structural integrity of the EVSS was maintained. The analytical results, therefore, help clarify the number of necessary cooling loops for efficient decay heat removal and sodium temperature behavior in an SBO.展开更多
针对非能动核电站的全厂断电(SBO Station Blackout)事故开展了比例分析研究,建立了重要热工水力现象的数学模型和相似准则。结合SBO事故特征,提出了一种功率比可变的试验模拟方法,并利用Relap5程序进行了分析验证。结果表明:在非能动...针对非能动核电站的全厂断电(SBO Station Blackout)事故开展了比例分析研究,建立了重要热工水力现象的数学模型和相似准则。结合SBO事故特征,提出了一种功率比可变的试验模拟方法,并利用Relap5程序进行了分析验证。结果表明:在非能动电站的SBO事故中,自然循环回路动量控制方程的非定常项为阻力项和驱动力项的高阶小量,可采用稳态动量方程进行比例分析;对于几何结构已固定的整体性试验台架,通过调节试验回路的形状阻力值,能够以多种功率比例关系进行SBO事故的试验设计和模拟,拓展了已有整体性试验台架的适用范围。展开更多
利用修改后的适用于固态熔盐堆的RELAP5/MOD4.0系统分析程序,对固态熔盐堆全厂断电ATWS(Anticipated Transient Without Scram)事故进行了分析。主回路系统进行了合理简化建模,模拟系统在全厂断电ATWS事故时非能动余热排出系统有效与否...利用修改后的适用于固态熔盐堆的RELAP5/MOD4.0系统分析程序,对固态熔盐堆全厂断电ATWS(Anticipated Transient Without Scram)事故进行了分析。主回路系统进行了合理简化建模,模拟系统在全厂断电ATWS事故时非能动余热排出系统有效与否两种情况下的瞬态响应过程。分析结果表明:非能动余热排出系统在全厂断电ATWS事故初期作用不明显,但长期作用较明显,投入使用后最终将使堆芯温度和主冷却剂温度达到稳定;对于固态熔盐堆来说,即使非能动余热排出系统失效,燃料元件温度上升也很缓慢,给人员干预采取必要措施提供了超过20天的宽限时间。分析结果表明了固态熔盐堆在应对极端事件时具有高的安全性。展开更多
文摘The prototype fast breeder reactor "MONJU" has an EVSS (ex-vessel fuel storage system) which consists mainly of an EVST (ex-vessel fuel storage tank) and an EVST sodium cooling system. EVST sodium cooling system consists of three independent loops. During the normal operation, the primary sodium in the EVST is circulated by natural convection and the secondary circulation in the EVST sodium cooling system is powered by electromagnetic pumps. When an SBO (station blackout) occurs, all the pumps and blowers are tripped. Therefore, it was necessary to evaluate the cooling ability by the natural circulation of sodium in the EVST sodium cooling system and air through the air cooler during the SBO. In this study, an analysis and evaluation of the plant dynamics for the spent fuel and the EVSS structural integrity during an SBO were performed. When the number of cooling loops was not changed and natural circulation occurred in only two loops, the sodium temperature in the EVST increased to approximately 450 ~C. However, the structural integrity of the EVSS was maintained. The analytical results, therefore, help clarify the number of necessary cooling loops for efficient decay heat removal and sodium temperature behavior in an SBO.
文摘针对非能动核电站的全厂断电(SBO Station Blackout)事故开展了比例分析研究,建立了重要热工水力现象的数学模型和相似准则。结合SBO事故特征,提出了一种功率比可变的试验模拟方法,并利用Relap5程序进行了分析验证。结果表明:在非能动电站的SBO事故中,自然循环回路动量控制方程的非定常项为阻力项和驱动力项的高阶小量,可采用稳态动量方程进行比例分析;对于几何结构已固定的整体性试验台架,通过调节试验回路的形状阻力值,能够以多种功率比例关系进行SBO事故的试验设计和模拟,拓展了已有整体性试验台架的适用范围。
文摘利用修改后的适用于固态熔盐堆的RELAP5/MOD4.0系统分析程序,对固态熔盐堆全厂断电ATWS(Anticipated Transient Without Scram)事故进行了分析。主回路系统进行了合理简化建模,模拟系统在全厂断电ATWS事故时非能动余热排出系统有效与否两种情况下的瞬态响应过程。分析结果表明:非能动余热排出系统在全厂断电ATWS事故初期作用不明显,但长期作用较明显,投入使用后最终将使堆芯温度和主冷却剂温度达到稳定;对于固态熔盐堆来说,即使非能动余热排出系统失效,燃料元件温度上升也很缓慢,给人员干预采取必要措施提供了超过20天的宽限时间。分析结果表明了固态熔盐堆在应对极端事件时具有高的安全性。