A soft x-ray Pulse Height Analysis (PHA) diagnostic with the recently introduced Silicon Drift Detector (SDD) and a new MCA system has been installed in HT-7 for the measurements of electron temperature. With the SDD ...A soft x-ray Pulse Height Analysis (PHA) diagnostic with the recently introduced Silicon Drift Detector (SDD) and a new MCA system has been installed in HT-7 for the measurements of electron temperature. With the SDD detector, the x-ray emission can be detected in the energy range from 1 keV up to 20 keV. The extremely low anode capacity of SDD allows very high counting rates of x-ray above 200 kHz and short shaping times below 0.25 μs to be measurede. In routine operation a counting rate of 120 kHz has been normally obtained with an energy resolution of better than 180 eV at 5.9 keV. The assembly is equipped with six SDD detectors measuring the soft x-ray emission integrated along six chords of the upper half plasma cross section. The preliminary results from the new soft x-ray PHA diagnostic are also presented in this paper.展开更多
Two soft X-ray pulse height analysis (PHA) systems, based on silicon drift detec- tor (SDD), were established on the experimental advanced superconducting tokamak (EAST) to measure spectrum of soft X-ray emissio...Two soft X-ray pulse height analysis (PHA) systems, based on silicon drift detec- tor (SDD), were established on the experimental advanced superconducting tokamak (EAST) to measure spectrum of soft X-ray emission. In this paper, the soft X-ray PHA systems on EAST are introduced and some experimental results of electron temperature in EAST obtained from the soft X-ray PHA diagnostic are presented.展开更多
基金The project supported by the National Natural Science Foundation of China (Nos. 10305012, 10375070)
文摘A soft x-ray Pulse Height Analysis (PHA) diagnostic with the recently introduced Silicon Drift Detector (SDD) and a new MCA system has been installed in HT-7 for the measurements of electron temperature. With the SDD detector, the x-ray emission can be detected in the energy range from 1 keV up to 20 keV. The extremely low anode capacity of SDD allows very high counting rates of x-ray above 200 kHz and short shaping times below 0.25 μs to be measurede. In routine operation a counting rate of 120 kHz has been normally obtained with an energy resolution of better than 180 eV at 5.9 keV. The assembly is equipped with six SDD detectors measuring the soft x-ray emission integrated along six chords of the upper half plasma cross section. The preliminary results from the new soft x-ray PHA diagnostic are also presented in this paper.
基金supported by National Natural Science Foundation of China (Nos.10775041,10675124)Youth Science FundsChinese Academy of Sciences,and the JSPS-CAS Core-University Program in the field of Plasma and Nuclear Fusion
文摘Two soft X-ray pulse height analysis (PHA) systems, based on silicon drift detec- tor (SDD), were established on the experimental advanced superconducting tokamak (EAST) to measure spectrum of soft X-ray emission. In this paper, the soft X-ray PHA systems on EAST are introduced and some experimental results of electron temperature in EAST obtained from the soft X-ray PHA diagnostic are presented.