期刊文献+
共找到4,282篇文章
< 1 2 215 >
每页显示 20 50 100
Scanning Electron Microscopy(SEM) Observations of Antennal Sensilla of Chrysopa pallens Rambur(Neuroptera:Chrysopidae)
1
作者 Wang Juan Chen Hongyin +3 位作者 Wang Mengqing Liu Chenxi Zhang Haiping Zhang Lisheng 《Plant Diseases and Pests》 CAS 2017年第2期1-4,19,共5页
[Objectives]The paper was to provide background information for ongoing research on relationship between smell and behavior of the green lacewing Chrysopa pallens( Rambur)( Neuroptera: Chrysopidae). [Methods]The ... [Objectives]The paper was to provide background information for ongoing research on relationship between smell and behavior of the green lacewing Chrysopa pallens( Rambur)( Neuroptera: Chrysopidae). [Methods]The submicroscopic structure of antennal sensilla of C. pallens was examined using scanning electron microscopy. [Results]Antennae of female and male C. pallens were linear in shape and( 1. 52 ± 0. 08) and( 1. 58 ± 0. 23) cm in length,respectively. The scape and pedicel were composed of single sub-segment,while the flagellum consisted of 116 sub-segments,on which most sensilla distributed. The flagella of female and male antennae were( 1. 44 ± 0. 04) and( 1. 47 ± 0. 13) cm in length,respectively. Nine morphological sensilla types were recorded in both sexes,including four types of highly abundant and widely distributed sensilla trichodea( ST Ⅰ,ST Ⅱ,ST Ⅲ and ST Ⅳ),three types of sensilla basiconica( SB Ⅰ,SB Ⅱ,and SB Ⅲ),and one of each type of sensilla chaetica and B9 hm bristles. Although the shape,structure,numbers,and distribution of antennae of females and males were basically similar,major differences were recorded between the sexes in the length of some sensilla types. Both the ST Ⅲ and SB Ⅰ in female adults were significantly longer than that in male ones. Notably,SB Ⅱ was found only in female. [Conclusions]The paper laid a foundation for revealing the relationship between smell and behavior,playing a crucial role in promoting the important biological control effect of C. pallens in farmland ecological system. 展开更多
关键词 Chrysopa pallens ANTENNA SENSILLA ULTRASTRUCTURE scanning electron microscopy
下载PDF
Scanning Electron Microscopy (SEM) of the Bug Eye and Sand Coral
2
作者 Sayid Ali Sayid Aliyu Dadan-Garba +1 位作者 Daniel Elaigwu Enenche Barnabas Achakpa Ikyo 《Microscopy Research》 2020年第1期1-7,共7页
We present a Scanning Electron Microscopy (SEM) technique for the characterisation of biological and non-biological samples at nano-scale level. Scanning Electron Microscopy has been around for a long while especially... We present a Scanning Electron Microscopy (SEM) technique for the characterisation of biological and non-biological samples at nano-scale level. Scanning Electron Microscopy has been around for a long while especially in material science laboratories in developed countries. The SEM has enabled scientist to have a better understanding of microstructure by providing unsurpassed optical magnifications of samples. In this introductory paper, we introduce the techniques of using SEM to capture highly magnified microstructure of a fly found on an African soybean (Glycine max) seed. We are able to estimate the number of lenses in each eye and zoom into features that could describe its life characteristics. Hexagonal lenses are estimated to have sizes ranging from 14 um to 19 um. This paper also presents a finding of a sea coral “pie like structure” on a single grain of sand used for water filtration. 展开更多
关键词 Bug Eye Sand Coral scanning electron microscopy
下载PDF
Adverse Effects of Permanent Waving and Hair Relaxation—Assessment by Scanning Electron Microscopy (SEM)
3
作者 Tokuya Omi Seiji Kawana 《Journal of Cosmetics, Dermatological Sciences and Applications》 2013年第3期45-48,共4页
Permanent waving is very popular in Japan. Polypeptide chains (main chains) form the principal components of hair, and they are lined up longitudinally. Hair relaxation is also called straight permanent waving, and th... Permanent waving is very popular in Japan. Polypeptide chains (main chains) form the principal components of hair, and they are lined up longitudinally. Hair relaxation is also called straight permanent waving, and there are methods that change curly or wavy hair into straight hair. Hair damage as a result of winding, combing, and using high-temperature hairdressing irons is also often seen. By using scanning electron micrographs (SEM) we showed broken hairs and hair damage caused by permanent wave solutions. The hair damage is obvious when comparisons are made with the condition of the hair surface, condition of the cuticle, etc. Hair swelling by permanent wave solutions, manipulations such as winding, etc., inadequate rinsing with water, procedures on injured hair at the outset, etc., are considered possible reasons for any of these types of injury. 展开更多
关键词 PERMANENT Waving HAIR RELAXATION scanning electron MICROGRAPHS (sem) HAIR Damage
下载PDF
TiO<sub>2</sub>Nanoparticles Induced Genotoxicity in Cultured Cells Using Atmospheric Scanning Electron Microscopy (ASEM)
4
作者 Shigeru Sato Takashi Takaki +1 位作者 Hidetoshi Nishiyama Tokuya Omi 《Journal of Cosmetics, Dermatological Sciences and Applications》 2013年第1期121-123,共3页
Nano-sized titanium oxide nanoparticles (TiO2 NPs) are widely used as a dye in food and cosmetics. TiO2 NPs are known to induce DNA damage when incorporated into cells. However, no bioassay is currently available to e... Nano-sized titanium oxide nanoparticles (TiO2 NPs) are widely used as a dye in food and cosmetics. TiO2 NPs are known to induce DNA damage when incorporated into cells. However, no bioassay is currently available to easily determine the cell incorporation of TiO2 NPs or related DNA damage, and to date, few studies have examined the different degrees of incorporation into cells according to the size of the TiO2 NPs particles and the presence or absence of cell specificity regarding DNA damage. This present study was therefore designed to examine COS7 cells that had incorporated TiO2 NPs using atmospheric scanning electron microscopy (ASEM). The results indicated that absorption of TiO2 NPs into cells and nuclear abnormalities had occurred. ASEM is a rapid and simple technique that enables the observation of samples immediately after fixation with glutaraldehyde and staining with phosphotungstic acid, and this method was suggested to be useful in screening for DNA damage. 展开更多
关键词 COS7 Cells TiO2 ATMOSPHERIC scanning electron microscopy (Asem) NANOPARTICLE
下载PDF
Scanning Electron Microscopy of Antennae of Aphidoletes aphidimyza (Diptera: Cecidomyiidae) 被引量:6
5
作者 张洁 杨茂发 《Zoological Research》 CAS CSCD 北大核心 2008年第1期108-112,共5页
The morphology of antennae of Aphidoletes aphidimyza was observed with a scanning electron microscope. The results showed that both male and female were fourteen segmented, the male was approximately 2000 μm and the ... The morphology of antennae of Aphidoletes aphidimyza was observed with a scanning electron microscope. The results showed that both male and female were fourteen segmented, the male was approximately 2000 μm and the female was 1050μm. Six types of sensillae on the antenna were observed, viz. chaetica (Ch), trichoidea (Tr), basiconica (Ba), cavity (Ca), styloid (St) and circumfila (Ci) on the antennae of A. aphidimyza. Sensillae Ch had a long external-process, with a base surrounded by membranous sockets and a length of about 67.5 μm. Sensillae Tr were distally curved and inserted into a depression, 61.0μm long. Sensillae Ba were peg-like and 4.7μm long on the antennae. Sensillae Ca were pit-like in appearance and the diameter of the pit was 1.2μm. Sensilla St was found on the second sub-segment flagellum of the male antennae. The length of the sensilla was about 21 μm and the diameter was 1.5μm. The circurnfila, which are a unique type of sensilla found only on cecidomyiid antennae, formed loops around each of the antennal sub-segments, and were attached to the surface by a series of stalks. Sensilla St was only present on male antenna. The number of Ba and Tr was almost the same in both sexes. There were more Sensilla Ca on the male antenna than on the female, while there was more Ch on the female. 展开更多
关键词 Aphidoletes aphidimyza scanning electron microscopy ANTENNA Sensillae ULTRASTRUCTURE
下载PDF
基于SEM的土体微观结构三维分析与分维计算方法 被引量:1
6
作者 张豫川 高旭龙 +1 位作者 刘东发 黄鸿伟 《长江科学院院报》 CSCD 北大核心 2024年第2期91-97,共7页
土体微观结构研究很早就建立了三维空间的分形模型,但分形维数计算所需参数很难由常规土工试验得到,限制了分形理论在土体研究中的应用。基于陕西定边与甘肃兰州原状土样的扫描电镜(SEM)试验,提出了三维化处理与三角形网格原理联合方法... 土体微观结构研究很早就建立了三维空间的分形模型,但分形维数计算所需参数很难由常规土工试验得到,限制了分形理论在土体研究中的应用。基于陕西定边与甘肃兰州原状土样的扫描电镜(SEM)试验,提出了三维化处理与三角形网格原理联合方法,可以得到土体颗粒(孔隙)不同测量尺度对应的表面积与体积计算值,由此实现分形维数的计算,并通过分形理论在土水特征中的应用验证了方法的有效性与可靠性。另外,三维化处理还可获取视孔隙率、比面等土体微观结构参数,可以作为土体微观结构定量分析研究的新途径。 展开更多
关键词 扫描电镜(sem) 微观结构 三维分析 分形维数
下载PDF
50 years of scanning electron microscopy of bone——a comprehensive overview of the important discoveries made and insights gained into bone material properties in health,disease,and taphonomy 被引量:2
7
作者 Furqan A.Shah Krisztina Ruscsák Anders Palmquist 《Bone Research》 SCIE CAS CSCD 2019年第2期123-137,共15页
Bone is an architecturally complex system that constantly undergoes structural and functional optimisation through renewal and repair.The scanning electron microscope (SEM) is among the most frequently used instrument... Bone is an architecturally complex system that constantly undergoes structural and functional optimisation through renewal and repair.The scanning electron microscope (SEM) is among the most frequently used instruments for examining bone.It offers the key advantage of very high spatial resolution coupled with a large depth of field and wide field of view.Interactions between incident electrons and atoms on the sample surface generate backscattered electrons,secondary electrons,and various other signals including X-rays that relay compositional and topographical information.Through selective removal or preservation of specific tissue components (organic,inorganic,cellular,vascular),their individual contribution(s) to the overall functional competence can be elucidated.With few restrictions on sample geometry and a variety of applicable sample-processing routes,a given sample may be conveniently adapted for multiple analytical methods.While a conventional SEM operates at high vacuum conditions that demand clean,dry,and electrically conductive samples,non-conductive materials (e.g.,bone) can be imaged without significant modification from the natural state using an environmental scanning electron microscope.This review highlights important insights gained into bone microstructure and pathophysiology,bone response to implanted biomaterials,elemental analysis,SEM in paleoarchaeology,3D imaging using focused ion beam techniques,correlative microscopy and in situ experiments.The capacity to image seamlessly across multiple length scales within the meso-micro-nano-continuum,the SEM lends itself to many unique and diverse applications,which attest to the versatility and user-friendly nature of this instrument for studying bone.Significant technological developments are anticipated for analysing bone using the SEM. 展开更多
关键词 scanning electron microscopy COMPREHENSIVE OVERVIEW important discoveries
下载PDF
Scanning transmission electron microscopy: A review of high angle annular dark field and annular bright field imaging and applications in lithium-ion batteries 被引量:2
8
作者 Yu-Xin Tong Qing-Hua Zhang Lin Gu 《Chinese Physics B》 SCIE EI CAS CSCD 2018年第6期23-34,共12页
Scanning transmission electron microscopy(STEM) has been shown as powerful tools for material characterization,especially after the appearance of aberration-corrector which greatly enhances the resolution of STEM. H... Scanning transmission electron microscopy(STEM) has been shown as powerful tools for material characterization,especially after the appearance of aberration-corrector which greatly enhances the resolution of STEM. High angle annular dark field(HAADF) and annular bright field(ABF) imaging of the aberration-corrected STEM are widely used due to their high-resolution capabilities and easily interpretable image contrasts. However, HAADF mode of the STEM is still limited in detecting light elements due to the weak electron-scattering power. ABF mode of the STEM could detect light and heavy elements simultaneously, providing unprecedented opportunities for probing unknown structures of materials. Atomiclevel structure investigation of materials has been achieved by means of these imaging modes, which is invaluable in many fields for either improving properties of materials or developing new materials. This paper aims to provide a introduction of HAADF and ABF imaging techniques and reviews their applications in characterization of cathode materials, study of electrochemical reaction mechanisms, and exploring the effective design of lithium-ion batteries(LIBs). The future prospects of the STEM are also discussed. 展开更多
关键词 scanning transmission electron microscopy high angle annular dark field annular bright field lithium-ion batteries
下载PDF
Bacterial entombment by intratubular mineralization following orthograde mineral trioxide aggregate obturation: a scanning electron microscopy study 被引量:5
9
作者 Jun Sang Yoo Seok-Woo Chang +8 位作者 So Ram Oh Hiran Perinpanayagam Sang-Min Lim Yeon-Jee Yoo Yeo-Rok Oh Sang-Bin Woo Seung-Hyun Han Qiang Zhu Kee-Yeon Kum 《International Journal of Oral Science》 SCIE CAS CSCD 2014年第4期227-232,共6页
The time domain entombment of bacteria by intratubular mineralization following orthograde canal obturation with mineral trioxide aggregate(MTA) was studied by scanning electron microscopy(SEM). Single-rooted huma... The time domain entombment of bacteria by intratubular mineralization following orthograde canal obturation with mineral trioxide aggregate(MTA) was studied by scanning electron microscopy(SEM). Single-rooted human premolars(n560) were instrumented to an apical size #50/0.06 using ProF ile and treated as follows: Group 1(n510) was filled with phosphate buffered saline(PBS); Group 2(n510) was incubated with Enterococcus faecalis for 3 weeks, and then filled with PBS; Group 3(n520) was obturated orthograde with a paste of OrthoM TA(BioM TA, Seoul, Korea) and PBS; and Group 4(n520) was incubated with E. faecalis for 3 weeks and then obturated with OrthoM TA–PBS paste. Following their treatments, the coronal openings were sealed with PBS-soaked cotton and intermediate restorative material(IRM), and the roots were then stored in PBS for 1, 2, 4, 8 or 16 weeks. After each incubation period, the roots were split and their dentin/MTA interfaces examined in both longitudinal and horizontal directions by SEM. There appeared to be an increase in intratubular mineralization over time in the OrthoM TA-filled roots(Groups 3 and 4). Furthermore, there was a gradual entombment of bacteria within the dentinal tubules in the E. faecalis inoculated MTA-filled roots(Group 4). Therefore, the orthograde obturation of root canals with OrthoM TA mixed with PBS may create a favorable environment for bacterial entombment by intratubular mineralization. 展开更多
关键词 bacterial entombment intratubular mineralization orthograde canal obturation scanning electron microscopy tag-like structure
下载PDF
Comparison of scanning electron microscopy findings regarding biofilm colonization with microbiological results in nasolacrimal stents for external, endoscopic and transcanalicular dacryocystorhinostomy 被引量:1
10
作者 Melike Balikoglu-Yilmaz Tolga Yilmaz +4 位作者 Sule Cetinel Umit Taskin Ayse Banu Esen Muhittin Taskapili Timur Kose 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2014年第3期534-540,共7页
AIM:To compare bacterial biofilm colonization in lacrimal stents following external dacryocystorhinostomy(EX-DCR),endoscopic dacryocystorhinostomy(EN-DCR),and transcanalicular dacryocystorhinostomy(TC-DCR)with multidi... AIM:To compare bacterial biofilm colonization in lacrimal stents following external dacryocystorhinostomy(EX-DCR),endoscopic dacryocystorhinostomy(EN-DCR),and transcanalicular dacryocystorhinostomy(TC-DCR)with multidiode laser.METHODS:This prospective study included 30consecutive patients with nasolacrimal duct obstruction who underwent EXT-,EN-,or TC-DCR.Thirty removed lacrimal stent fragments and conjunctival samples were cultured.The lacrimal stent biofilms were examined by scanning electron microscopy(SEM).RESULTS:Eleven(36.7%)of the 30 lacrimal stent cultures were positive for aerobic bacteria(most commonly Staphylococcus epidermidis and Pseudomonas aeruginosa).However anaerobic bacteria and fungi were not identified in the lacrimal stent cultures.Twenty-seven(90%)patients had biofilmpositive lacrimal stents.The conjunctival culture positivity after the DCR,biofilm positivity on stents,the grade of biofilm colonization,and the presence of mucus and coccoid and rod-shaped organisms did not significantly differ between any of the groups(P】0.05).However,a significant difference was found when the SEM results were compared to the results of the lacrimal stent and conjunctival cultures(P【0.001).CONCLUSION:Type of dacryocystorhinostomy(DCR)surgery did not affect the biofilm colonization of the lacrimal stents.SEM also appears to be more precise than microbiological culture for evaluating the presence of biofilms on lacrimal stents. 展开更多
关键词 biofilms nasolacrimal duct obstruction EPIPHORA DACRYOCYSTITIS scanning electron microscopy
下载PDF
Recent progress on advanced transmission electron microscopy characterization for halide perovskite semiconductors 被引量:1
11
作者 Xiaomei Wu Xiaoxing Ke Manling Sui 《Journal of Semiconductors》 EI CAS CSCD 2022年第4期67-81,共15页
Halide perovskites are strategically important in the field of energy materials. Along with the rapid development of the materials and related devices, there is an urgent need to understand the structure–property rel... Halide perovskites are strategically important in the field of energy materials. Along with the rapid development of the materials and related devices, there is an urgent need to understand the structure–property relationship from nanoscale to atomic scale. Much effort has been made in the past few years to overcome the difficulty of imaging limited by electron dose,and to further extend the investigation towards operando conditions. This review is dedicated to recent studies of advanced transmission electron microscopy(TEM) characterizations for halide perovskites. The irradiation damage caused by the interaction of electron beams and perovskites under conventional imaging conditions are first summarized and discussed. Low-dose TEM is then discussed, including electron diffraction and emerging techniques for high-resolution TEM(HRTEM) imaging. Atomic-resolution imaging, defects identification and chemical mapping on halide perovskites are reviewed. Cryo-TEM for halide perovskites is discussed, since it can readily suppress irradiation damage and has been rapidly developed in the past few years. Finally, the applications of in-situ TEM in the degradation study of perovskites under environmental conditions such as heating,biasing, light illumination and humidity are reviewed. More applications of emerging TEM characterizations are foreseen in the coming future, unveiling the structural origin of halide perovskite’s unique properties and degradation mechanism under operando conditions, so to assist the design of a more efficient and robust energy material. 展开更多
关键词 organic–inorganic hybrid perovskite solar cell materials energy materials scanning electron microscopy transmission electron microscopy irradiation damage
下载PDF
Evolution of pore systems in low-maturity oil shales during thermal upgrading--Quantified by dynamic SEM and machine learning
12
作者 Jun Liu Xue Bai Derek Elsworth 《Petroleum Science》 SCIE EI CAS CSCD 2024年第3期1739-1750,共12页
In-situ upgrading by heating is feasible for low-maturity shale oil,where the pore space dynamically evolves.We characterize this response for a heated substrate concurrently imaged by SEM.We systematically follow the... In-situ upgrading by heating is feasible for low-maturity shale oil,where the pore space dynamically evolves.We characterize this response for a heated substrate concurrently imaged by SEM.We systematically follow the evolution of pore quantity,size(length,width and cross-sectional area),orientation,shape(aspect ratio,roundness and solidity)and their anisotropy—interpreted by machine learning.Results indicate that heating generates new pores in both organic matter and inorganic minerals.However,the newly formed pores are smaller than the original pores and thus reduce average lengths and widths of the bedding-parallel pore system.Conversely,the average pore lengths and widths are increased in the bedding-perpendicular direction.Besides,heating increases the cross-sectional area of pores in low-maturity oil shales,where this growth tendency fluctuates at<300℃ but becomes steady at>300℃.In addition,the orientation and shape of the newly-formed heating-induced pores follow the habit of the original pores and follow the initial probability distributions of pore orientation and shape.Herein,limited anisotropy is detected in pore direction and shape,indicating similar modes of evolution both bedding-parallel and bedding-normal.We propose a straightforward but robust model to describe evolution of pore system in low-maturity oil shales during heating. 展开更多
关键词 Low-maturity oil shale Pore elongation Organic matter pyrolysis In-situthermal upgrading scanning electron microscopy(sem) Machine learning
下载PDF
Scanning electron microscopy coupled with energydispersive X-ray spectrometry for quick detection of sulfuroxidizing bacteria in environmental water samples 被引量:1
13
作者 SUN Chengjun JIANG Fenghua +5 位作者 GAO Wei LI Xiaoyun YU Yanzhen YIN Xiaofei WANG Yong DING Haibing 《Chinese Journal of Oceanology and Limnology》 SCIE CAS CSCD 2017年第1期185-191,共7页
Detection of sulfur-oxidizing bacteria has largely been dependent on targeted gene sequencing technology or traditional cell cultivation, which usually takes from days to months to carry out. This clearly does not mee... Detection of sulfur-oxidizing bacteria has largely been dependent on targeted gene sequencing technology or traditional cell cultivation, which usually takes from days to months to carry out. This clearly does not meet the requirements of analysis for time-sensitive samples and/or complicated environmental samples. Since energy-dispersive X-ray spectrometry(EDS) can be used to simultaneously detect multiple elements in a sample, including sulfur, with minimal sample treatment, this technology was applied to detect sulfur-oxidizing bacteria using their high sulfur content within the cell. This article describes the application of scanning electron microscopy imaging coupled with EDS mapping for quick detection of sulfur oxidizers in contaminated environmental water samples, with minimal sample handling. Scanning electron microscopy imaging revealed the existence of dense granules within the bacterial cells, while EDS identified large amounts of sulfur within them. EDS mapping localized the sulfur to these granules. Subsequent 16S rRNA gene sequencing showed that the bacteria detected in our samples belonged to the genus Chromatium, which are sulfur oxidizers. Thus, EDS mapping made it possible to identify sulfur oxidizers in environmental samples based on localized sulfur within their cells, within a short time(within 24 h of sampling). This technique has wide ranging applications for detection of sulfur bacteria in environmental water samples. 展开更多
关键词 sulfur bacteria energy-dispersive X-ray spectrometry scanning electron microscopy bacteria detection environmental water samples 16S rRNA sequencing
下载PDF
Nanoscale cathodoluminescence spectroscopy probing the nitride quantum wells in an electron microscope
14
作者 刘哲彤 刘秉尧 +8 位作者 梁冬冬 李晓梅 李晓敏 陈莉 朱瑞 徐军 魏同波 白雪冬 高鹏 《Chinese Physics B》 SCIE EI CAS CSCD 2024年第3期144-149,共6页
To gain further understanding of the luminescence properties of multiquantum wells and the factors affecting them on a microscopic level,cathodoluminescence combined with scanning transmission electron microscopy and ... To gain further understanding of the luminescence properties of multiquantum wells and the factors affecting them on a microscopic level,cathodoluminescence combined with scanning transmission electron microscopy and spectroscopy was used to measure the luminescence of In_(0.15)Ga_(0.85)N five-period multiquantum wells.The lattice-composition-energy relationship was established with the help of energy-dispersive x-ray spectroscopy,and the bandgaps of In_(0.15)Ga_(0.85)N and GaN in multiple quantum wells were extracted by electron energy loss spectroscopy to understand the features of cathodoluminescence spectra.The luminescence differences between different periods of multiquantum wells and the effects of defects such as composition fluctuation and dislocations on the luminescence of multiple quantum wells were revealed.Our study establishing the direct relationship between the atomic structure of In_(x)Ga_(1-x)N multiquantum wells and photoelectric properties provides useful information for nitride applications. 展开更多
关键词 nitride multiquantum wells defect CATHODOLUMINESCENCE scanning transmission electron microscopy
下载PDF
IDENTIFICATION OF MARINE AEROSOL COMPONENT BY COMBINED NAA AND SCANNING ELECTRON MICROSCOPY WITH X—RAY ANALYSIS
15
作者 杨绍晋 章一鸣 《Nuclear Science and Techniques》 SCIE CAS CSCD 1992年第3期205-209,共5页
The concentrations of 30 elements in aerosol particles collected in western Pacific ocean have been determined by INAA. The crustal element concentrations decrease with increasing distance from land over the remote ar... The concentrations of 30 elements in aerosol particles collected in western Pacific ocean have been determined by INAA. The crustal element concentrations decrease with increasing distance from land over the remote area close to Asia land and fluctuate around its average value over the remote ocean area. The volatile elements exhibite average atmospheric concentrations that are higher than those expected from the flux of seasalt or the continental dust. In order to identify marine aerosol component originating from the continent or ocean, the aerosol particles are examined by scanning electron microscopy combined with energy dispersive X-ray spectroscopy. Particle phase structure shows that the crustal aerosol particles are not present internal mixtures with seasalt aerosol, and it also proves the long-range transport of crustal elements from continent to ocean. 展开更多
关键词 AEROSOL scanning electron microscopy INAA EDS
下载PDF
Scanning Electron Acoustic Microscopy of GaInAsSb by Metalorganic Chemical Vapor Deposition
16
作者 李树玮 金亿鑫 +3 位作者 周天明 张宝林 宁永强 蒋红 《Rare Metals》 SCIE EI CAS CSCD 1996年第2期101-105,共5页
Scanning electron acoustic microscopy (SEAM) is a new technique for imasing and characterization ofthermal, elastic and pyroelectric property variations on a microscale resolution. The signal generation mechanisms and... Scanning electron acoustic microscopy (SEAM) is a new technique for imasing and characterization ofthermal, elastic and pyroelectric property variations on a microscale resolution. The signal generation mechanisms and the application of scanning electron acoustic microscopy in GalnAsSb alloy grown by MOCVD wereinvestigated. Defects below the surface of GalnAsSb alloy were found by SEAM images and cathodelumi-nescence. The results show that electronacoustic imaging has its own features over secondary electron imag-ing. 展开更多
关键词 scanning electron acoustic microscopy electron-acoustic imaging GAINASSB MOCVD
下载PDF
Ultrastructural Analysis of the Ontogenetic Development of Shoot Induced from Embryonic Axes of Costa Rican Bean Varieties (<i>Phaseolus vulgaris</i>L.) under <i>in Vitro</i>Conditions by Scanning Electronic Microscopy
17
作者 Marisol Jiménez Andrés Gatica +1 位作者 Ethel Sánchez Marta Valdez 《American Journal of Plant Sciences》 2012年第4期489-494,共6页
Common bean (Phaseolus vulgaris L.) is an economic important crop and one of the major grain legumes for human consumption in Latin America, Africa and Asia. A morphological study of shoot induced from embryonic axes ... Common bean (Phaseolus vulgaris L.) is an economic important crop and one of the major grain legumes for human consumption in Latin America, Africa and Asia. A morphological study of shoot induced from embryonic axes development in four Costa Rican bean varieties (Brunca, Huetar, Guaymi and Bribri) cultivated on MS media with or without 5 mg·L–1 de N6-benzylaminopurine (BAP) by scanning electron microscopy (SEM) was developed in the present work. Micrographs showed similarities and differences in the ultrastructure of the apical dome, epidermal surface, stomata and different types of trichomes in the varieties cultivated on organogenesis media. Genotypes with advantageous morphological characteristics for genetic transformation, in particular an exposed apical dome, were identified. This work will contribute to the optimization of the in vitro regeneration of four common bean varieties. 展开更多
关键词 PHASEOLUS vulgaris L BEAN In Vitro ORGANOGENESIS SHOOT scanning electron microscopy (sem)
下载PDF
Study of a Novel Small Caliber Vascular Graft in a Canine Model with Optical and Scanning Electron Microscopy 被引量:1
18
作者 XU Yi-min QI Song-tao SHI Xiao-feng ZENG Shao-wen LI Wei-qiu HUANG Guang-long ZHUANG Bing-rong 《Chinese Journal of Biomedical Engineering(English Edition)》 2007年第1期22-32,共11页
A novel biological small-diameter vascular graft was evaluated in a canine model. 3 cm long segments with 4 mm I.D. were implanted end-to-end in the carotid position of 12 dogs for 6 months. Color Doppler sonography w... A novel biological small-diameter vascular graft was evaluated in a canine model. 3 cm long segments with 4 mm I.D. were implanted end-to-end in the carotid position of 12 dogs for 6 months. Color Doppler sonography was performed at the first week post-operation, and angiography was then administered to 9 grafts at 4th week, 12th week and 24th week respectively to monitor the graft pantency and blood flow characteristics. Vascular samples containing the grafts were collected at 1st week, 8th week, 12th week and 24th week after implantation. Morphological changes of the grafts were observed by optical and scanning electron microscopic (SEM) studies and compared with that of the original prosthesis and the normal host vessel. All grafts were patent throughout the experiment except one graft. Histopathology and SEM demonstrated both a nearly complete inner capsule of varied thickness lining the graft luminal surface and connective tissue adventitia formation at one-week post-operation. The neointima became confluent at 8 weeks and then compact but had no signs of hyperplasia up to 12 weeks; meanwhile on the neointimal surface newly grown endothelial-like cells were migrating from the stoma to the middle portion. The grafts also illustrated endothelialization in many “islands” in the mid-segment luminal surface of the grafts. In addition, the closer distance the cells towards the stoma were, the more morphological similarity the cells with the normal endothelial were. Taken together, the biological vascular graft remained patent for 24 weeks as a carotid prosthesis, characterized by the early and complete neointima formation plus endothelialization starting before 12 weeks post grafting. Therefore, the graft seems suitable for reconstruction of vascular lesions in dogs. Further studies may be carried out to extend the graft application for the clinical use. 展开更多
关键词 DOG Surgical implantation Common carotid artery Biological vascular graft RECONSTRUCTION HISTOPATHOLOGY scanning electron microscopy ENDOTHELIALIZATION
下载PDF
Scanning Electron Microscopy Studies of YBa_2Cu_3O_(7-δ) Superconductors
19
作者 沙维 《Rare Metals》 SCIE EI CAS CSCD 1995年第4期245-248,共4页
Micrcostructures of bulk and thin film YBa_2Cu_3O_(7-δ) superconductors were studied by using scanning elec-tron microscopy (SEM). It was confirmed that viscous technique processed bulk YBa_2Cu_3O_(7-δ) has a homoge... Micrcostructures of bulk and thin film YBa_2Cu_3O_(7-δ) superconductors were studied by using scanning elec-tron microscopy (SEM). It was confirmed that viscous technique processed bulk YBa_2Cu_3O_(7-δ) has a homoge-neous microstructure across the pellet diameter. Concerning the thin film, it was found that 2  ̄H ̄+ ion implanta-tion with a dose of 1× 10 ̄(12)cm ̄(-2) at 50 keV does not cause microstructural change of the film at a micrometrelevel. Combined with previous studies by using high resolution transmission electron microscopy, it appearsthat the structural modification is at an atomic scale. 展开更多
关键词 SUPERCONDUCTORS Thin film Ion implantation scanning elec-tron microscopy(sem)
下载PDF
OBSERVATION AND ANALYSIS OF BLOOD CONTACTING SURFACE OF LEFT VENTRICULAR ASSIST DEVICE WITH SCANNING ELECTRON MICROSCOPY
20
作者 王惠荪 金永安 秦家楠 《Medical Bulletin of Shanghai Jiaotong University》 CAS 1989年第Z1期72-78,共7页
Thrombus formation in the artificial heart blood pump is a complex problem. The most important factor of thrombosis in the blood pump is the quality of blood contacting surface which is related to hemocompatibility of... Thrombus formation in the artificial heart blood pump is a complex problem. The most important factor of thrombosis in the blood pump is the quality of blood contacting surface which is related to hemocompatibility of materials and micromorphololgy or roughness of the surface. So it is necessary to understand the morphology of the surface inside of blood pump in order to develop and improve a good quality blood pump. The authors observed and analysed the inner surface of blood pumps (both preimplanted and postimplanted) with scanning electron microscopy (SEM) providing a means for evaluating the blood pumps and for developing good quality of blood pumps. It was observed that there were four kinds of surface defects on the inner surface of the blood pumps: air bubble domes, open bubble craters, contaminated dust and gel particles. Microcrakes had also been found on the diaphragm of the postimplanted pump. But in the newly improved blood pump that had been imlanted for 16 days, there were few defects on the blood contacting surface, and only a little fibrinous layer observed. It could be considered that the current design and modifications are reasonable. Since some problems associated with the surface defects and thrombosis still existed, further improvement in fabrication process and quality control procedures with SEM are under way. 展开更多
关键词 LEFT VENTRICULAR assist device scanning electron microscopy POLYURETHANE BLOOD contacting SURFACE SURFACE defects THROMBOSIS
下载PDF
上一页 1 2 215 下一页 到第
使用帮助 返回顶部