Non-Contact Stress Measurement during Tensile Testing Using an Emat for SH<sub>0</sub>-Plate Wave and Lamb Wave 被引量:4
1
作者 Riichi Murayama 《Journal of Sensor Technology》 2011年第3期65-70,共6页
The stress on a test specimen during tensile testing is generally measured by a strain gauge. This method has some problems in that it would influence the measurement conditions of the tensile test and can evaluate on... The stress on a test specimen during tensile testing is generally measured by a strain gauge. This method has some problems in that it would influence the measurement conditions of the tensile test and can evaluate only the position at which the strain gauge is attached. The acoustoelastic method is proposed as a method replacing the strain gauge method. However, an ultrasonic sensor with a piezoelectric oscillator requires a coupling medium to inject an ultrasonic wave into a solid material. This condition, due to the error factor of the stress measurement, makes it difficult for the ultrasonic sensor to move on the specimen. We then tried to develop a non-contact stress measurement system during tensile testing using an electromagnetic acoustic transducer (EMAT) with an SH0-plate wave and S0-Lamb wave. The EMAT can measure the propagation time in which the ultrasonic wave travels between a receiver and a transmitter without a coupling medium during the tensile testing and can move easily. The interval between the transmitter and the receiver is 10mm and can be moved along the parallel direction or the vertical direction of the tensile load. The transit time was measured by a cross-correlation method and converted into the stress on the test specimen using the acoustoelastic method. We confirmed that the stress measurement using an SH0-plate wave was superior to that with an S0-Lamb wave. 展开更多
关键词 Nondestructive Inspection Ultrasonic Sensor Stress ACOUSTOELASTICITY sh0-plate wave S0-Lamb wave Tensile Test Electromagnetic Acoustic Transducer
下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部