The effect of signal sampling depth in SIMS on profile was not reported We have found that the maximum sampling depth in SIMS is considerably bigger than the mean penetration range of primary ions and can skew the pro...The effect of signal sampling depth in SIMS on profile was not reported We have found that the maximum sampling depth in SIMS is considerably bigger than the mean penetration range of primary ions and can skew the profile of secondary ion counts for implanted samples on the more deeper direction from the surface. The effect of maximum sampling depth is true not only for implanted samples but also for the samples in the middle of which there is an other impurity-rich layer. The action principle of signal sampling depth effect and the method of decreasing the error produced by the effect are discussed in this展开更多
Past research has demonstrated that if the intensity image of an object is uniformly down-sampled and converted into a Fresnel hologram, the phase component alone will be sufficient to reconstruct the source image. Ho...Past research has demonstrated that if the intensity image of an object is uniformly down-sampled and converted into a Fresnel hologram, the phase component alone will be sufficient to reconstruct the source image. However, due to down-sampling, the edge and line patterns are degraded heavily. In this Letter, we propose an enhance- ment on the parent method by incorporating an adaptive down-sampling lattice. A hologram generated with our proposed method, which is referred to as the edge-enhanced sampled phase-only hologram, preserves favorable visual quality on both the shaded regions as well as the edge patterns of the object image.展开更多
A 20 Gsample/s photonic analog-to-digital converter is constructed using a 4-switching-wavelength repetitive sampling pulse source. The signal-to-noise and distortion ratio (SINAD) is measured to be 44.5 dB and corres...A 20 Gsample/s photonic analog-to-digital converter is constructed using a 4-switching-wavelength repetitive sampling pulse source. The signal-to-noise and distortion ratio (SINAD) is measured to be 44.5 dB and corresponds to 7 effective number of bits.展开更多
In ring laser gyros (RLGs), dynamic lock-in, which results from information loss in the lock-in region, occurs when a constant sine bias is introduced. However, sampling some signals in the lock-in region for a part...In ring laser gyros (RLGs), dynamic lock-in, which results from information loss in the lock-in region, occurs when a constant sine bias is introduced. However, sampling some signals in the lock-in region for a particular duration allows the retrieval of lost information. It is demonstrated how dynamic lock-in and the flat region in the input-output curve near the zero angle rate can be eliminated after compensation.展开更多
We first clarify timing issues of non-uniform sampling intervals regarding a 5 GS/s fast pulse sampling module with DRS4. A calibration strategy is proposed, and as a result, the waveform timing performance is improve...We first clarify timing issues of non-uniform sampling intervals regarding a 5 GS/s fast pulse sampling module with DRS4. A calibration strategy is proposed, and as a result, the waveform timing performance is improved to below 10 ps RMS. We then further evaluate waveform-timing performance of the module by comparing with a 10 GS/s oscilloscope in a setup with plastic scintillators and fast PMTs. Different waveform timing algorithms are employed for analysis, and the module shows comparable timing performance with that of the oscilloscope.展开更多
基金This work is supported by National Natural Science Fundation.
文摘The effect of signal sampling depth in SIMS on profile was not reported We have found that the maximum sampling depth in SIMS is considerably bigger than the mean penetration range of primary ions and can skew the profile of secondary ion counts for implanted samples on the more deeper direction from the surface. The effect of maximum sampling depth is true not only for implanted samples but also for the samples in the middle of which there is an other impurity-rich layer. The action principle of signal sampling depth effect and the method of decreasing the error produced by the effect are discussed in this
文摘Past research has demonstrated that if the intensity image of an object is uniformly down-sampled and converted into a Fresnel hologram, the phase component alone will be sufficient to reconstruct the source image. However, due to down-sampling, the edge and line patterns are degraded heavily. In this Letter, we propose an enhance- ment on the parent method by incorporating an adaptive down-sampling lattice. A hologram generated with our proposed method, which is referred to as the edge-enhanced sampled phase-only hologram, preserves favorable visual quality on both the shaded regions as well as the edge patterns of the object image.
文摘A 20 Gsample/s photonic analog-to-digital converter is constructed using a 4-switching-wavelength repetitive sampling pulse source. The signal-to-noise and distortion ratio (SINAD) is measured to be 44.5 dB and corresponds to 7 effective number of bits.
基金supported by the Program for New Century Excellent Talents in Universities(2010)
文摘In ring laser gyros (RLGs), dynamic lock-in, which results from information loss in the lock-in region, occurs when a constant sine bias is introduced. However, sampling some signals in the lock-in region for a particular duration allows the retrieval of lost information. It is demonstrated how dynamic lock-in and the flat region in the input-output curve near the zero angle rate can be eliminated after compensation.
基金Supported by Knowledge Innovation Program of the Chinese Academy of Sciences(KJCX2-YW-N27)National Natural Science Foundation of China(11175176)
文摘We first clarify timing issues of non-uniform sampling intervals regarding a 5 GS/s fast pulse sampling module with DRS4. A calibration strategy is proposed, and as a result, the waveform timing performance is improved to below 10 ps RMS. We then further evaluate waveform-timing performance of the module by comparing with a 10 GS/s oscilloscope in a setup with plastic scintillators and fast PMTs. Different waveform timing algorithms are employed for analysis, and the module shows comparable timing performance with that of the oscilloscope.