期刊文献+
共找到2篇文章
< 1 >
每页显示 20 50 100
裂解气相色谱-质谱对二元共混橡胶体系进行定量分析的新方法 被引量:6
1
作者 杨正春 范国樑 +2 位作者 龚彩荣 张和顺 徐海红 《分析测试学报》 CAS CSCD 北大核心 2007年第z1期127-129,共3页
A new method has recently developed,the solution sampling method(SMM),to quantify the binary rubber blends of NR/BR by pyrolysis/gas chromatography/mass spectrometry(PY/GC/MS).The rubbers were swelled in the cyclohexa... A new method has recently developed,the solution sampling method(SMM),to quantify the binary rubber blends of NR/BR by pyrolysis/gas chromatography/mass spectrometry(PY/GC/MS).The rubbers were swelled in the cyclohexane,using the hydrogen peroxide solution to destroy the cross-linked structure of the rubbers and then the rubbers can be sloved in the cyclohexane.The rubber solution was applied to the spiral section of the injector.The solvent was evaporated depositing the rubber on the spiral section,and the rubber was prolyzed at 550℃.Then calculate the weight percentage by the characteristic peak area ratio.One test rubber,NR/BR where the weight percentage of NR is 50% was calculated.The error was 5.64%. 展开更多
关键词 NR/BR solution Sampling Method PY/GC-MS
下载PDF
A simple vacuum sample chamber for small-angle X-ray scattering at Beijing synchrotron radiation facility
2
作者 Zhenzhong Li Zhihong Li +2 位作者 Fei Xie Dongfeng Li Baoliang Lv 《Radiation Detection Technology and Methods》 CSCD 2019年第3期155-159,共5页
Objective A vacuum sample chamber for SAXS measurement of solutions was developed to improve the signal-to-noise ratio of the instrument at Beijing Synchrotron Radiation Facility(BSRF).Methods We developed a vacuum sa... Objective A vacuum sample chamber for SAXS measurement of solutions was developed to improve the signal-to-noise ratio of the instrument at Beijing Synchrotron Radiation Facility(BSRF).Methods We developed a vacuum sample chamber which could be connected to the upstream and the downstream vacuum tubes by bellows.Horizontal and vertical linear slides were mounted in the vacuum chamber to adjust the sample position by 35 mm in the horizontal and vertical directions to align the sample in the light path.The liquid sample holder of the chamber was sealed with polyimide film by squeezing instead of gluing to avoid the potential influence of sealant on the solution.Results The chamber had been used for SAXS measurements of water and bovine serum albumin solution at BSRF.The results showed that the background scattering intensity in air was much higher than that in vacuum,especially in the smallangle area near the beamstop.When the q value is 0.142 nm−1,1.01 nm−1 and 1.25 nm−1,the background scattering intensity in air is 45,6.8 and 4.6 times of that in vacuum,respectively.And the background-subtracted scattering curves of bovine serum albumin solution(10 mg/ml)in air and vacuum differ in intensity by a factor of about 2.When the q value is 2 nm−1,the signal-to-noise ratios of scattering intensity of BSA in air and vacuum are 0.79 and 8.51,respectively.Conclusion We designed a simple vacuum sample chamber to be used on the SAXS instrument at 1W2A station of BSRF.The scattering of the background and protein solution in air and vacuum was tested and compared,and the signal-to-noise ratio was clearly improved. 展开更多
关键词 Small-angle X-ray scattering Vacuum sample chamber solution sample Signal-to-noise ratio
原文传递
上一页 1 下一页 到第