期刊文献+
共找到2篇文章
< 1 >
每页显示 20 50 100
Hydrogen and Ozone SAW Based Gas Sensors with RF Magnetron Sputtered InO_x and Electron Beam Evaporated SiN_y 被引量:1
1
作者 A.C.Fechete A.Wisitsora-at +3 位作者 W.Wlodarskil K.Kalantar-zadeh S.Kandasamy A.S.Holland 《稀有金属材料与工程》 SCIE EI CAS CSCD 北大核心 2006年第A03期206-209,共4页
Layered Surface Acoustic Wave (SAW) devices with an InO_x/SiN_u/36°YX LiTaO_3 structure were investigated for sensing low concentrations of hydrogen (H_2) and ozone (O_3) at different operating temperatures.The s... Layered Surface Acoustic Wave (SAW) devices with an InO_x/SiN_u/36°YX LiTaO_3 structure were investigated for sensing low concentrations of hydrogen (H_2) and ozone (O_3) at different operating temperatures.The sensor consists of a 1μm thick silicon nitride (SiN_y) intermediate layer deposited by electron beam evaporation on a 36°Y-cut X-propagating piezoelectric lithium tantalate (LiTaO_3) substrate and a 100 nm thin indium oxide (InO_x) sensing layer deposited by R.F.magnetron sputtering.The device fabrication is described and the performance of the sensor is analyzed in terms of response magnitude as a function of operating temperature.Large frequency shifts of 360 kHz for 600μg/g of H_2 and 92 kHz for 40 ng/g O_3 were recorded.In addition,the surface morphology of the deposited films were investigated by Atomic Force Microscopy (AFM) and the chemical composition by X-Ray Photoelectron Spectroscopy (XPS) to correlate gas-sensing behavior to structural characteristics of the thin film. 展开更多
关键词 saw gas sensors E-beam evaporated SiN_y InO_x O3 H2
下载PDF
Sniffing lung cancer related biomarkers using an oxidized graphene SAW sensor 被引量:1
2
作者 张鑫方 张正伟 +5 位作者 何焰兰 刘一星 黎双 方靖越 张学骜 彭刚 《Frontiers of physics》 SCIE CSCD 2016年第2期109-113,共5页
Decane is one of the volatile organic compounds (VOCs) in human breath. Successful detection of decane in human breath has vast prospects for early lung cancer diagnosis. In this paper, a novel detecting device base... Decane is one of the volatile organic compounds (VOCs) in human breath. Successful detection of decane in human breath has vast prospects for early lung cancer diagnosis. In this paper, a novel detecting device based on a filter surface acoustic wave (SAW) gas sensor is presented. SAW sensors coated with a thin oxidized graphene film were used to detect decane in parts per million (ppm) concentrations. Control and signal detection circuits were designed using a vector network analyzer with a detection resolution of insertion loss down to 0.0001 dB. The results showed that the SAW sensor could respond quickly with great sensitivity when exposed to 0.2 ppm decane. This device shows tremendous potential in medical diagnosis and environmental assessment. 展开更多
关键词 DECANE graphene oxide lung-cancer biomarker saw gas sensor
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部