Beam uniformity is a crucial building block of CO2 experiments aimed at fusing and stretching optical fibers in a lossless manner. When the irradiation beam is expanded through a galvanometer mirror, ways to achieve b...Beam uniformity is a crucial building block of CO2 experiments aimed at fusing and stretching optical fibers in a lossless manner. When the irradiation beam is expanded through a galvanometer mirror, ways to achieve beam uniformity are investigated.展开更多
To obtain a good interference fringe contrast and high fidelity,an automated beam iterative alignment is achieved in scanning beam interference lithography(SBIL).To solve the problem of alignment failure caused by a l...To obtain a good interference fringe contrast and high fidelity,an automated beam iterative alignment is achieved in scanning beam interference lithography(SBIL).To solve the problem of alignment failure caused by a large beam angle(or position)overshoot exceeding the detector range while also speeding up the convergence,a weighted iterative algorithm using a weight parameter that is changed linearly piecewise is proposed.The changes in the beam angle and position deviation during the alignment process based on different iterative algorithms are compared by experiment and simulation.The results show that the proposed iterative algorithm can be used to suppress the beam angle(or position)overshoot,avoiding alignment failure caused by over-ranging.In addition,the convergence speed can be effectively increased.The algorithm proposed can optimize the beam alignment process in SBIL.展开更多
The collection efficiency of monitor parallel plate ionization chambers is the main uncertainty in the beam control of pencil beam scanning systems.Existing calculation methods for collection efficiency in photon or p...The collection efficiency of monitor parallel plate ionization chambers is the main uncertainty in the beam control of pencil beam scanning systems.Existing calculation methods for collection efficiency in photon or passive scattering proton systems have not considered the characteristics of non-uniform charge density in pencil beam scanning systems.In this study,Boag’s theory was applied to a proton pencil beam scanning system.The transverse distribution of charge density in the ionization chamber was considered to be a Gaussian function and an analytical solution was derived to calculate collection efficiency in the beam spot area.This calculation method is called the integral method and it was used to investigate the effects of beam parameters on collection efficiency.It was determined that collection efficiency is positively correlated with applied voltage,beam size,and beam energy,but negatively correlated with beam current intensity.Additionally,it was confirmed that collection efficiency is improved when the air filling the monitor parallel plate ionization chamber is replaced with nitrogen.展开更多
The spatial resolution of a commercial two-dimensional(2D)ionization chamber(IC)array is limited by the size of the individual detector and the center-to-center distance between sensors.For dose distributions with are...The spatial resolution of a commercial two-dimensional(2D)ionization chamber(IC)array is limited by the size of the individual detector and the center-to-center distance between sensors.For dose distributions with areas of steep dose gradients,inter-detector dose values are derived by the interpolation of nearby detector readings in the conventional mathematical interpolation of 2D IC array measurements.This may introduce significant errors,particularly in proton spot scanning radiotherapy.In this study,by combining logfile-based reconstructed dose values and detector measurements with the Laplacian pyramid image blending method,a novel method is proposed to obtain a reformatted dose distribution that provides an improved estimation of the delivered dose distribution with high spatial resolution.Meanwhile,the similarity between the measured original data and the downsampled logfilebased reconstructed dose is regarded as the confidence of the reformatted dose distribution.Furthermore,we quantify the performance benefits of this new approach by directly comparing the reformatted dose distributions with 2D IC array detector mathematically interpolated measurements and original low-resolution measurements.The result shows that this new method is better than the mathematical interpolation and achieves gamma pass rates similar to those of the original low-resolution measurements.The reformatted dose distributions generally yield a confidence exceeding 95%.展开更多
In the terahertz(THz) band, the inherent shake of the human body may strongly impair the image quality of a beam scanning single frequency holography system for personnel screening. To realize accurate shake compens...In the terahertz(THz) band, the inherent shake of the human body may strongly impair the image quality of a beam scanning single frequency holography system for personnel screening. To realize accurate shake compensation in imaging processing, it is quite necessary to develop a high-precision measure system. However, in many cases, different parts of a human body may shake to different extents, resulting in greatly increasing the difficulty in conducting a reasonable measurement of body shake errors for image reconstruction. In this paper, a body shake error compensation algorithm based on the raw data is proposed. To analyze the effect of the body shake on the raw data, a model of echoed signal is rebuilt with considering both the beam scanning mode and the body shake. According to the rebuilt signal model, we derive the body shake error estimated method to compensate for the phase error. Simulation on the reconstruction of point targets with shake errors and proof-of-principle experiments on the human body in the 0.2-THz band are both performed to confirm the effectiveness of the body shake compensation algorithm proposed.展开更多
Purpose: To quantitatively evaluate four different Proton SFUD PBS initial planning strategies for lung mobile tumor. Methods and Materials: A virtual lung patient’s four-dimensional computed tomography (4DCT) was ge...Purpose: To quantitatively evaluate four different Proton SFUD PBS initial planning strategies for lung mobile tumor. Methods and Materials: A virtual lung patient’s four-dimensional computed tomography (4DCT) was generated in this study. To avoid the uncertainties from target delineation and imaging artifacts, a sphere with diameter of 3 cm representing a rigid mobile target (GTV) was inserted into the right side of the lung. The target motion is set in superior-inferior (SI) direction from ?5 mm to 5 mm. Four SFUD planning strategies were used based on: 1) Maximum-In-tensity-Projection Image (MIP-CT);2) CT_average with ITV overridden to muscle density (CTavg_muscle);3) CT_average with ITV overridden to tumor density (CTavg_tumor);4) CT_average without any override density (CTavg_only). Dose distributions were recalculated on each individual phase and accumulated together to assess the “actual” treatment. To estimate the impact of proton range uncertainties, +/?3.5% CT calibration curve was applied to the 4DCT phase images. Results: Comparing initial plan to the dose accumulation: MIP-CT based GTV D98 degraded 2.42 Gy (60.10 Gy vs 57.68 Gy). Heart D1 increased 6.19 Gy (1.88 Gy vs 8.07 Gy);CTavg_tumor based GTV D98 degraded 0.34 Gy (60.07 Gy vs 59.73 Gy). Heart D1 increased 2.24 Gy (3.74 Gy vs 5.98 Gy);CTavg_muscle based initial GTV D98 degraded 0.31 Gy (60.4 Gy vs 60.19 Gy). Heart D1 increased 3.44 Gy (4.38 Gy vs 7.82 Gy);CTavg_only based Initial GTV D98 degraded 6.63 Gy (60.11 Gy vs 53.48 Gy). Heart D1 increased 0.30 Gy (2.69 Gy vs 2.96 Gy);in the presence of ±3.5% range uncertainties, CTavg_tumor based plan’s accumulated GTV D98 degraded to 57.99 Gy (+3.5%) 59.38 Gy (?3.5%), and CTavg_muscle based plan’s accumulated GTV D98 degraded to 59.37 Gy (+3.5%) 59.37 Gy (?3.5%). Conclusion: This study shows that CTavg_Tumor and CTavg_Muscle based planning strategies provide the most robust GTV coverage. However, clinicians need to be aware that the actual dose to OARs at distal end of target may increase. The study also indicates that the current SFUD PBS planning strategy might not be sufficient to compensate the CT calibration uncertainty.展开更多
In this paper, we first propose a metamaterial structure by etching the same two interdigital fingers on the upper ground of quarter mode substrate integrated waveguide(QMSIW). The simulated results show that the pr...In this paper, we first propose a metamaterial structure by etching the same two interdigital fingers on the upper ground of quarter mode substrate integrated waveguide(QMSIW). The simulated results show that the proposed QMSIWbased metamaterial has a continuous phase constant changing from negative to positive values within its passband. A periodic leaky-wave antenna(LWA), which consists of 11 QMSIW-based metamaterial unit cells, is designed, fabricated,and measured. The measured results show that the fabricated antenna achieves a continuous beam scanning property from backward-43° to forward +32° over an operating frequencyrange of 8.9 GHz–11.8 GHz with return loss better than 10 d B.The measured antenna gain keeps consistent with the variation of less than 2 d B over the operating frequency range with a maximum gain of 12 d B. Besides, the measured and simulated results are in good agreement with each other, indicating the significance and effectiveness of this method.展开更多
We perform molecular beam epitaxy growth and scanning tunneling microscopy study of copper diselenide (CuSe2 ) films on SrTiO3 (001). Using a Se-rich condition, the single-phase pyrite CuSe2 grows in the Stranski-...We perform molecular beam epitaxy growth and scanning tunneling microscopy study of copper diselenide (CuSe2 ) films on SrTiO3 (001). Using a Se-rich condition, the single-phase pyrite CuSe2 grows in the Stranski-Krastanov (layer-plus-island) mode with a preferential orientation of (111). Our careful inspection of both the as-grown and post-annealed CuSe2 films at various temperatures invariably shows a Cu-terminated surface, which, depending on the annealing temperature, reconstructs into two distinct structures 2 ×√3 and √x ×√3-R30°. The Cu termi- nation is supported by the depressed density of states near the Fermi level, measured by in-situ low temperature scanning tunneling spectroscopy. Our study helps understand the preparation and surface chemistry of transition metal pyrite dichalcogenides thin films.展开更多
The approach for enlargement of SAR patch mapping area by antenna beam scan is investigated, which serves for moderate fine-resolution mapping of medium-sized terrain patches. The scanning angular velocity and the sca...The approach for enlargement of SAR patch mapping area by antenna beam scan is investigated, which serves for moderate fine-resolution mapping of medium-sized terrain patches. The scanning angular velocity and the scanning angular scope are determined respectively. The angular velocity of the scanning antenna is controlled to scan over just one azimuth 3 dB beam width in the time interval during which the radar platform moves over one synthetic aperture length determined from the desired cross-range resolution, radar wavelength, nominal slant range, and squint angle. The scanning angular scope is mainly determined by the azimuth width of the terrain patch, nominal slant range, squint angle, platform velocity, and azimuth beam width. Finally, the related experimental results of an airborne SAR are presented. The linear range-Doppler algorithm is employed in image formation after motion compensation is conducted to remove the effect of transnational motion of the radar platform relative to the map center.展开更多
A compact 10 MeV S-band irradiation electron linear accelerator(linac)was developed to simulate electronic radiation in outer space and perform electron irradiation effect tests on spacecraft materials and devices.Acc...A compact 10 MeV S-band irradiation electron linear accelerator(linac)was developed to simulate electronic radiation in outer space and perform electron irradiation effect tests on spacecraft materials and devices.According to the requirements of space environment simulation,the electron beam energy can be adjusted in the range from 3.5 to 10 MeV,and the average current can be adjusted in the range from 0.1 to 1 mA.The linac should be capable of providing beam irradiation over a large area of 1 m^(2) with a uniformity greater than 90% and a scanning rate of 100 Hz.A novel method was applied to achieve such a high beam scanning rate by combining a kicker and a scanning magnet.Based on this requirement,a design for the10 MeV linac is proposed with an RF power pulse repetition rate of 500 Hz;it includes a thermal cathode electron gun,a bunching-accelerating section,and a scanning transport line.The detailed physical design and dynamic simulation results of the proposed 10 MeV electron linac are presented in this paper.展开更多
The application of superconducting(SC)technology enables magnets to excite strong fields with small footprints,which has great potential for miniaturizing proton therapy gantries.However,the slow ramping rate of SC ma...The application of superconducting(SC)technology enables magnets to excite strong fields with small footprints,which has great potential for miniaturizing proton therapy gantries.However,the slow ramping rate of SC magnets results in a low treatment efficiency compared with normal-conducting(NC)gantries.To address this problem,this study proposes a compact proton therapy gantry design with a large momentum acceptance utilizing alternating-gradient canted-cosine-theta(AG-CCT)SC magnets.In our design,a high-transmission degrader is mounted in the middle of the gantry,and the upstream beamline employs NC magnets with small apertures.Downstream of the degrader,large-bore AG-CCT magnets with strong alternating focusing gradients are set symmetrically as a local achromat,which realizes a momentum acceptance of 20%(or 40%in the energy domain).Therefore,only three magnetic working points are required to cover a treatment energy of 70-230 Me V.Owing to the large momentum acceptance,the proton beam after the degrader can be directly delivered to the isocenter without truncating its energy spectrum,which can significantly increase the treatment efficiency but causes severe dispersion effects during pencil beam scanning.Therefore,a compensation method was introduced by tuning the normal and skewed quadrupoles during the scanning process.As a result,the new gantry not only presents a remarkable reduction in the size and weight of the facility but also shows good potential for fast treatment.展开更多
Phased array radar has been applied broadly because of its sound performance.But signal of phased array radar is of a wide variety of types.Therefore,recognition of phased array radar is the most puzzling aspect of th...Phased array radar has been applied broadly because of its sound performance.But signal of phased array radar is of a wide variety of types.Therefore,recognition of phased array radar is the most puzzling aspect of the whole emitter identification domain.To solve the problem,the article proposes the method that identifies phased array radar by pulse amplitude information,and studies the phased array radar,models transmit signal of them,and receiving signal by radar countermeasure reconnaissance receiver.From constructing template of pulse train's amplitude vector of mechanical scanning radar,computing distance of samples and standard template,finding threshold of the template matching arithmetic,the article puts forward the template matching algorithm of radar beam scan type recognition to identify phased array radar automatically.展开更多
In this paper,a 2D angle amplifier based on peristrophic multiplexed volume Bragg gratings is designed and prepared,in which a calculation method is firstly proposed to optimize the number of channels to a minimum.The...In this paper,a 2D angle amplifier based on peristrophic multiplexed volume Bragg gratings is designed and prepared,in which a calculation method is firstly proposed to optimize the number of channels to a minimum.The induction of peristrophic multiplexing reduces the performance difference in one bulk of the grating,whereas there is no need to deliberately optimize the fabrication process.It is revealed that a discrete 2D angle deflection range of±30°is obtained and the relative diffraction efficiency of all the grating channels reaches more than 55%with a root-meansquare deviation of less than 3.4%in the same grating.The deviation of the Bragg incidence and exit angles from the expected values is less than 0.07°.It is believed that the proposed 2D angle amplifier has the potential to realize high-performance and large-angle beam steering in high-power laser beam scanning systems.展开更多
This paper presents an approach for mitigating the cross-eye jamming using a dual-polarization array. By transmitting a sum beam and a difference beam in two orthogonal polarimetric channels, a synthesized transmitted...This paper presents an approach for mitigating the cross-eye jamming using a dual-polarization array. By transmitting a sum beam and a difference beam in two orthogonal polarimetric channels, a synthesized transmitted beam with spatially varying polarization is produced, such that the polarization of the transmitted radar wave varies in azimuth or elevation. Thus, the phases of the signals received on the two antennas of a cross-eye jammer become unequal, and an additional phase difference is introduced to disrupt the 180? phase shifting in the retrodirective loop of the jammer. By means of beam scanning in a small angular range,the optimal beam steering configuration can be found to maximize the phase error for the mitigation of cross-eye jamming. As a result, the jamming performance of the cross-eye jammer degrades largely. Theoretical analysis and simulation results indicate that the proposed method is valid and feasible.展开更多
Coding metasurfaces make it possible to manipulate electromagnetic(EM)waves digitally by means of several discrete particles.Hence,there have been rapid advances in this field recently.Here we propose a novel design o...Coding metasurfaces make it possible to manipulate electromagnetic(EM)waves digitally by means of several discrete particles.Hence,there have been rapid advances in this field recently.Here we propose a novel design of a broadband transmission-type coding metasurface,which is valid to both x-and y-polarized EM incidences from 8.1-12.5 GHz while satisfies the requirements of 1-bit coding without changing the polarization.Two types of multi-layer coding particles with different geometrical parameters are adopted to represent the digital states"0"and"1",which are easily promoted to terahertz and optics through modifying the size scale.To verify the ability to manipulate the EM waves,we first adopt the coding metasurface to achieve broadband beam forming by converting spherical waves to plane waves and realize high-directivity pencil beam in far field with low side lobes.We further arrange the particles according to the coding sequence 010101…to steer two symmetrical beams in different directions controlled by frequencies with the maximum range of the scanning angle of 30°-50.5°.The good agreements between the simulated and measured results validate the proposed broadband coding metasurface,indicating its huge potential in communication and radar imaging systems.展开更多
For industrial computed tomography systems, generation II scan mode has a large field of view but time consuming and generation III has a small field of view but fast. In order to realize the rapid ICT test of large ...For industrial computed tomography systems, generation II scan mode has a large field of view but time consuming and generation III has a small field of view but fast. In order to realize the rapid ICT test of large objects, a scan mode based on generation III called large field of view scan was discussed and its reconstruction algorithm based on FBP was deduced. The validity of the algorithm was verified by the results of computer simulation and experiments. Analysis showed that the effective scan field of view could be improved by more than 90% compared with that of generation III.展开更多
The three-dimensional(3D)pore structures and permeability of shale are critical for forecasting gas production capacity and guiding pressure differential control in practical reservoir extraction.However,few investiga...The three-dimensional(3D)pore structures and permeability of shale are critical for forecasting gas production capacity and guiding pressure differential control in practical reservoir extraction.However,few investigations have analyzed the effects of microscopic organic matter(OM)morphology and 3D pore nanostructures on the stress sensitivity,which are precisely the most unique and controlling factors of reservoir quality in shales.In this study,ultra-high nanoscale-resolution imaging experiments,i.e.focused ion beam-scanning electron microscopy(FIB-SEMs),were conducted on two organic-rich shale samples from Longmaxi and Wufeng Formations in northern Guizhou Depression,China.Pore morphology,porosity of 3D pore nanostructures,pore size distribution,and connectivity of the six selected regions of interest(including clump-shaped OMs,interstitial OMs,framboidal pyrite,and microfractures)were qualitatively and quantitatively characterized.Pulse decay permeability(PDP)measurement was used to investigate the variation patterns of stress-dependent permeability and stress sensitivity of shales under different confining pressures and pore pressures,and the results were then used to calculate the Biot coefficients for the two shale formations.The results showed that the samples have high OM porosity and 85%of the OM pores have the radius of less than 40 nm.The OM morphology and pore structure characteristics of the Longmaxi and Wufeng Formations were distinctly different.In particular,the OM in the Wufeng Formation samples developed some OM pores with radius larger than500 nm,which significantly improved the connectivity.The macroscopic permeability strongly depends on the permeability of OM pores.The stress sensitivity of permeability of Wufeng Formation was significantly lower than that of Longmaxi Formation,due to the differences in OM morphology and pore structures.The Biot coefficients of 0.729 and 0.697 were obtained for the Longmaxi and Wufeng Formations,respectively.展开更多
It is very important to measure local deformations for an in-depth understanding of mechanical properties and fracture mechanism of structural and functional materials. In this paper, different types of model grid fab...It is very important to measure local deformations for an in-depth understanding of mechanical properties and fracture mechanism of structural and functional materials. In this paper, different types of model grid fabrication methods and many types of electron Moire methods using an electron beam drawing system, a scanning electron microscope or a focus ion beam are reported, together with their applications in the measurement of deformations occurring in various engineerings and materials science research.展开更多
This study shows that submicron/nanoparticles found in bacterial cells (S. aureus) incubated with polyurethane (a material commonly used for prostheses in odontostomatology) are a consequence of biodestruction. The pr...This study shows that submicron/nanoparticles found in bacterial cells (S. aureus) incubated with polyurethane (a material commonly used for prostheses in odontostomatology) are a consequence of biodestruction. The presence of polyurethane nanoparticles into bacterial vesicles suggests that the internalization process occurs through endocytosis. TEM and FIB/SEM are a suitable set of correlated instruments and techniques for this multi facet investigation: polyurethane particles influence the properties of S. aureus from the morpho-functional standpoint that may have undesirable effects on the human body. S. aureus and C. albicans are symbiotic microorganisms;it was observed that C. albicans has a similar interaction with polyurethane and an increment of the biodestruction capacity is expected by its mutual work with S. aureus.展开更多
Background In the field of particle therapy,the method of pencil beam scanning is of great potential for clinical application,now and in the future.Purpose The authors made strong effort to develop a spot scanning sys...Background In the field of particle therapy,the method of pencil beam scanning is of great potential for clinical application,now and in the future.Purpose The authors made strong effort to develop a spot scanning system for Shanghai Proton Therapy Facility.Design parameters and basic layout of the system are introduced.Methods Functionalities and specifications of crucial devices are described in detail.Most of the devices in the system were designed in house by the authors themselves,including scanning nozzle,scanning magnets and their power supplies,beam monitors,irradiation control modules and safety interlock modules.During the technical commissioning stage in the fix beam room,the spot scanning system was tested and verified.Results Under conditions of the maximum dose rate and minimum dose rate,a)repeatability of the single spot dose is less than±0.1%;b)nonlinearity of the single spot dose is less than±0.1%;c)FWHM for spot size in air at isocenter varies from 8mm to 12mm for full energy,consistent with the design values;d)lateral dose distribution achieves a flatness of less than 2%for multiple proton energies.Conclusion According to the results of technical commissioning,the spot scanning system is capable of producing a pre-scribed 3D dose distribution for target tumor successfully.展开更多
文摘Beam uniformity is a crucial building block of CO2 experiments aimed at fusing and stretching optical fibers in a lossless manner. When the irradiation beam is expanded through a galvanometer mirror, ways to achieve beam uniformity are investigated.
基金The research was supported by the National Natural Science Foundation of China(NSFC)(Grant No.61227901)Jilin Province Science&Technology Development Program Project in China(Grant No.20190103157JH).
文摘To obtain a good interference fringe contrast and high fidelity,an automated beam iterative alignment is achieved in scanning beam interference lithography(SBIL).To solve the problem of alignment failure caused by a large beam angle(or position)overshoot exceeding the detector range while also speeding up the convergence,a weighted iterative algorithm using a weight parameter that is changed linearly piecewise is proposed.The changes in the beam angle and position deviation during the alignment process based on different iterative algorithms are compared by experiment and simulation.The results show that the proposed iterative algorithm can be used to suppress the beam angle(or position)overshoot,avoiding alignment failure caused by over-ranging.In addition,the convergence speed can be effectively increased.The algorithm proposed can optimize the beam alignment process in SBIL.
文摘The collection efficiency of monitor parallel plate ionization chambers is the main uncertainty in the beam control of pencil beam scanning systems.Existing calculation methods for collection efficiency in photon or passive scattering proton systems have not considered the characteristics of non-uniform charge density in pencil beam scanning systems.In this study,Boag’s theory was applied to a proton pencil beam scanning system.The transverse distribution of charge density in the ionization chamber was considered to be a Gaussian function and an analytical solution was derived to calculate collection efficiency in the beam spot area.This calculation method is called the integral method and it was used to investigate the effects of beam parameters on collection efficiency.It was determined that collection efficiency is positively correlated with applied voltage,beam size,and beam energy,but negatively correlated with beam current intensity.Additionally,it was confirmed that collection efficiency is improved when the air filling the monitor parallel plate ionization chamber is replaced with nitrogen.
文摘The spatial resolution of a commercial two-dimensional(2D)ionization chamber(IC)array is limited by the size of the individual detector and the center-to-center distance between sensors.For dose distributions with areas of steep dose gradients,inter-detector dose values are derived by the interpolation of nearby detector readings in the conventional mathematical interpolation of 2D IC array measurements.This may introduce significant errors,particularly in proton spot scanning radiotherapy.In this study,by combining logfile-based reconstructed dose values and detector measurements with the Laplacian pyramid image blending method,a novel method is proposed to obtain a reformatted dose distribution that provides an improved estimation of the delivered dose distribution with high spatial resolution.Meanwhile,the similarity between the measured original data and the downsampled logfilebased reconstructed dose is regarded as the confidence of the reformatted dose distribution.Furthermore,we quantify the performance benefits of this new approach by directly comparing the reformatted dose distributions with 2D IC array detector mathematically interpolated measurements and original low-resolution measurements.The result shows that this new method is better than the mathematical interpolation and achieves gamma pass rates similar to those of the original low-resolution measurements.The reformatted dose distributions generally yield a confidence exceeding 95%.
基金supported by the Knowledge Innovation Program of the Chinese Academy of Sciences(Grant No.YYYJ-1123)
文摘In the terahertz(THz) band, the inherent shake of the human body may strongly impair the image quality of a beam scanning single frequency holography system for personnel screening. To realize accurate shake compensation in imaging processing, it is quite necessary to develop a high-precision measure system. However, in many cases, different parts of a human body may shake to different extents, resulting in greatly increasing the difficulty in conducting a reasonable measurement of body shake errors for image reconstruction. In this paper, a body shake error compensation algorithm based on the raw data is proposed. To analyze the effect of the body shake on the raw data, a model of echoed signal is rebuilt with considering both the beam scanning mode and the body shake. According to the rebuilt signal model, we derive the body shake error estimated method to compensate for the phase error. Simulation on the reconstruction of point targets with shake errors and proof-of-principle experiments on the human body in the 0.2-THz band are both performed to confirm the effectiveness of the body shake compensation algorithm proposed.
文摘Purpose: To quantitatively evaluate four different Proton SFUD PBS initial planning strategies for lung mobile tumor. Methods and Materials: A virtual lung patient’s four-dimensional computed tomography (4DCT) was generated in this study. To avoid the uncertainties from target delineation and imaging artifacts, a sphere with diameter of 3 cm representing a rigid mobile target (GTV) was inserted into the right side of the lung. The target motion is set in superior-inferior (SI) direction from ?5 mm to 5 mm. Four SFUD planning strategies were used based on: 1) Maximum-In-tensity-Projection Image (MIP-CT);2) CT_average with ITV overridden to muscle density (CTavg_muscle);3) CT_average with ITV overridden to tumor density (CTavg_tumor);4) CT_average without any override density (CTavg_only). Dose distributions were recalculated on each individual phase and accumulated together to assess the “actual” treatment. To estimate the impact of proton range uncertainties, +/?3.5% CT calibration curve was applied to the 4DCT phase images. Results: Comparing initial plan to the dose accumulation: MIP-CT based GTV D98 degraded 2.42 Gy (60.10 Gy vs 57.68 Gy). Heart D1 increased 6.19 Gy (1.88 Gy vs 8.07 Gy);CTavg_tumor based GTV D98 degraded 0.34 Gy (60.07 Gy vs 59.73 Gy). Heart D1 increased 2.24 Gy (3.74 Gy vs 5.98 Gy);CTavg_muscle based initial GTV D98 degraded 0.31 Gy (60.4 Gy vs 60.19 Gy). Heart D1 increased 3.44 Gy (4.38 Gy vs 7.82 Gy);CTavg_only based Initial GTV D98 degraded 6.63 Gy (60.11 Gy vs 53.48 Gy). Heart D1 increased 0.30 Gy (2.69 Gy vs 2.96 Gy);in the presence of ±3.5% range uncertainties, CTavg_tumor based plan’s accumulated GTV D98 degraded to 57.99 Gy (+3.5%) 59.38 Gy (?3.5%), and CTavg_muscle based plan’s accumulated GTV D98 degraded to 59.37 Gy (+3.5%) 59.37 Gy (?3.5%). Conclusion: This study shows that CTavg_Tumor and CTavg_Muscle based planning strategies provide the most robust GTV coverage. However, clinicians need to be aware that the actual dose to OARs at distal end of target may increase. The study also indicates that the current SFUD PBS planning strategy might not be sufficient to compensate the CT calibration uncertainty.
基金Project supported by the National Natural Science Foundation of China(Grant No.61372034)
文摘In this paper, we first propose a metamaterial structure by etching the same two interdigital fingers on the upper ground of quarter mode substrate integrated waveguide(QMSIW). The simulated results show that the proposed QMSIWbased metamaterial has a continuous phase constant changing from negative to positive values within its passband. A periodic leaky-wave antenna(LWA), which consists of 11 QMSIW-based metamaterial unit cells, is designed, fabricated,and measured. The measured results show that the fabricated antenna achieves a continuous beam scanning property from backward-43° to forward +32° over an operating frequencyrange of 8.9 GHz–11.8 GHz with return loss better than 10 d B.The measured antenna gain keeps consistent with the variation of less than 2 d B over the operating frequency range with a maximum gain of 12 d B. Besides, the measured and simulated results are in good agreement with each other, indicating the significance and effectiveness of this method.
基金Supported by the National Natural Science Foundation of China under Grant Nos 11374336 and 61176078
文摘We perform molecular beam epitaxy growth and scanning tunneling microscopy study of copper diselenide (CuSe2 ) films on SrTiO3 (001). Using a Se-rich condition, the single-phase pyrite CuSe2 grows in the Stranski-Krastanov (layer-plus-island) mode with a preferential orientation of (111). Our careful inspection of both the as-grown and post-annealed CuSe2 films at various temperatures invariably shows a Cu-terminated surface, which, depending on the annealing temperature, reconstructs into two distinct structures 2 ×√3 and √x ×√3-R30°. The Cu termi- nation is supported by the depressed density of states near the Fermi level, measured by in-situ low temperature scanning tunneling spectroscopy. Our study helps understand the preparation and surface chemistry of transition metal pyrite dichalcogenides thin films.
文摘The approach for enlargement of SAR patch mapping area by antenna beam scan is investigated, which serves for moderate fine-resolution mapping of medium-sized terrain patches. The scanning angular velocity and the scanning angular scope are determined respectively. The angular velocity of the scanning antenna is controlled to scan over just one azimuth 3 dB beam width in the time interval during which the radar platform moves over one synthetic aperture length determined from the desired cross-range resolution, radar wavelength, nominal slant range, and squint angle. The scanning angular scope is mainly determined by the azimuth width of the terrain patch, nominal slant range, squint angle, platform velocity, and azimuth beam width. Finally, the related experimental results of an airborne SAR are presented. The linear range-Doppler algorithm is employed in image formation after motion compensation is conducted to remove the effect of transnational motion of the radar platform relative to the map center.
文摘A compact 10 MeV S-band irradiation electron linear accelerator(linac)was developed to simulate electronic radiation in outer space and perform electron irradiation effect tests on spacecraft materials and devices.According to the requirements of space environment simulation,the electron beam energy can be adjusted in the range from 3.5 to 10 MeV,and the average current can be adjusted in the range from 0.1 to 1 mA.The linac should be capable of providing beam irradiation over a large area of 1 m^(2) with a uniformity greater than 90% and a scanning rate of 100 Hz.A novel method was applied to achieve such a high beam scanning rate by combining a kicker and a scanning magnet.Based on this requirement,a design for the10 MeV linac is proposed with an RF power pulse repetition rate of 500 Hz;it includes a thermal cathode electron gun,a bunching-accelerating section,and a scanning transport line.The detailed physical design and dynamic simulation results of the proposed 10 MeV electron linac are presented in this paper.
基金supported by the National Natural Science Foundation of China(No.11975107,12205111)。
文摘The application of superconducting(SC)technology enables magnets to excite strong fields with small footprints,which has great potential for miniaturizing proton therapy gantries.However,the slow ramping rate of SC magnets results in a low treatment efficiency compared with normal-conducting(NC)gantries.To address this problem,this study proposes a compact proton therapy gantry design with a large momentum acceptance utilizing alternating-gradient canted-cosine-theta(AG-CCT)SC magnets.In our design,a high-transmission degrader is mounted in the middle of the gantry,and the upstream beamline employs NC magnets with small apertures.Downstream of the degrader,large-bore AG-CCT magnets with strong alternating focusing gradients are set symmetrically as a local achromat,which realizes a momentum acceptance of 20%(or 40%in the energy domain).Therefore,only three magnetic working points are required to cover a treatment energy of 70-230 Me V.Owing to the large momentum acceptance,the proton beam after the degrader can be directly delivered to the isocenter without truncating its energy spectrum,which can significantly increase the treatment efficiency but causes severe dispersion effects during pencil beam scanning.Therefore,a compensation method was introduced by tuning the normal and skewed quadrupoles during the scanning process.As a result,the new gantry not only presents a remarkable reduction in the size and weight of the facility but also shows good potential for fast treatment.
基金Supported by the National Science and Technology Supported Program of China(No.2011BAH24B06)
文摘Phased array radar has been applied broadly because of its sound performance.But signal of phased array radar is of a wide variety of types.Therefore,recognition of phased array radar is the most puzzling aspect of the whole emitter identification domain.To solve the problem,the article proposes the method that identifies phased array radar by pulse amplitude information,and studies the phased array radar,models transmit signal of them,and receiving signal by radar countermeasure reconnaissance receiver.From constructing template of pulse train's amplitude vector of mechanical scanning radar,computing distance of samples and standard template,finding threshold of the template matching arithmetic,the article puts forward the template matching algorithm of radar beam scan type recognition to identify phased array radar automatically.
基金supported by the National Key R&D Program of China(No.2020YFA0714500)the Shanghai Strategic Emerging Industry Development Special Fund(No.31011442501217020191D3101001)+1 种基金the National Natural Science Foundation of China(Nos.61875212 and U1831211)the International Partnership Program of Chinese Academy of Sciences(No.181231KYSB20200040)
文摘In this paper,a 2D angle amplifier based on peristrophic multiplexed volume Bragg gratings is designed and prepared,in which a calculation method is firstly proposed to optimize the number of channels to a minimum.The induction of peristrophic multiplexing reduces the performance difference in one bulk of the grating,whereas there is no need to deliberately optimize the fabrication process.It is revealed that a discrete 2D angle deflection range of±30°is obtained and the relative diffraction efficiency of all the grating channels reaches more than 55%with a root-meansquare deviation of less than 3.4%in the same grating.The deviation of the Bragg incidence and exit angles from the expected values is less than 0.07°.It is believed that the proposed 2D angle amplifier has the potential to realize high-performance and large-angle beam steering in high-power laser beam scanning systems.
基金supported by the National Natural Science Foundation of China(6149069261401488)
文摘This paper presents an approach for mitigating the cross-eye jamming using a dual-polarization array. By transmitting a sum beam and a difference beam in two orthogonal polarimetric channels, a synthesized transmitted beam with spatially varying polarization is produced, such that the polarization of the transmitted radar wave varies in azimuth or elevation. Thus, the phases of the signals received on the two antennas of a cross-eye jammer become unequal, and an additional phase difference is introduced to disrupt the 180? phase shifting in the retrodirective loop of the jammer. By means of beam scanning in a small angular range,the optimal beam steering configuration can be found to maximize the phase error for the mitigation of cross-eye jamming. As a result, the jamming performance of the cross-eye jammer degrades largely. Theoretical analysis and simulation results indicate that the proposed method is valid and feasible.
基金supported by the National Key Research and Development Program of China(Grant Nos.2017YFA0700201,2017YFA0700202,and 2017YFA0700203)the National Natural Science Foundation of China(Grant Nos.61631007,61731010,61735010,61722106,61701107,and 61701108)+4 种基金the Fund for International Cooperation and Exchange of the National Natural Science Foundation of China(Grant No.61761136007)the Overseas Expertise Introduction Project for Discipline Innovation(Grant No.111-2-05)the Fundamental Research Funds for the Central UniversitiesPostgraduate Research&Practice Innovation Program of Jiangsu Province(Grant No.KYCX17_0092)the Scientific Research Foundation of Graduate School of Southeast University(Grant No.YBJJ1815)。
文摘Coding metasurfaces make it possible to manipulate electromagnetic(EM)waves digitally by means of several discrete particles.Hence,there have been rapid advances in this field recently.Here we propose a novel design of a broadband transmission-type coding metasurface,which is valid to both x-and y-polarized EM incidences from 8.1-12.5 GHz while satisfies the requirements of 1-bit coding without changing the polarization.Two types of multi-layer coding particles with different geometrical parameters are adopted to represent the digital states"0"and"1",which are easily promoted to terahertz and optics through modifying the size scale.To verify the ability to manipulate the EM waves,we first adopt the coding metasurface to achieve broadband beam forming by converting spherical waves to plane waves and realize high-directivity pencil beam in far field with low side lobes.We further arrange the particles according to the coding sequence 010101…to steer two symmetrical beams in different directions controlled by frequencies with the maximum range of the scanning angle of 30°-50.5°.The good agreements between the simulated and measured results validate the proposed broadband coding metasurface,indicating its huge potential in communication and radar imaging systems.
文摘For industrial computed tomography systems, generation II scan mode has a large field of view but time consuming and generation III has a small field of view but fast. In order to realize the rapid ICT test of large objects, a scan mode based on generation III called large field of view scan was discussed and its reconstruction algorithm based on FBP was deduced. The validity of the algorithm was verified by the results of computer simulation and experiments. Analysis showed that the effective scan field of view could be improved by more than 90% compared with that of generation III.
基金supported by the National Key R&D Program of China(Grant No.2020YFA0711802)the Strategic Program of Chinese Academy of Sciences(Grant No.XDB10030400)。
文摘The three-dimensional(3D)pore structures and permeability of shale are critical for forecasting gas production capacity and guiding pressure differential control in practical reservoir extraction.However,few investigations have analyzed the effects of microscopic organic matter(OM)morphology and 3D pore nanostructures on the stress sensitivity,which are precisely the most unique and controlling factors of reservoir quality in shales.In this study,ultra-high nanoscale-resolution imaging experiments,i.e.focused ion beam-scanning electron microscopy(FIB-SEMs),were conducted on two organic-rich shale samples from Longmaxi and Wufeng Formations in northern Guizhou Depression,China.Pore morphology,porosity of 3D pore nanostructures,pore size distribution,and connectivity of the six selected regions of interest(including clump-shaped OMs,interstitial OMs,framboidal pyrite,and microfractures)were qualitatively and quantitatively characterized.Pulse decay permeability(PDP)measurement was used to investigate the variation patterns of stress-dependent permeability and stress sensitivity of shales under different confining pressures and pore pressures,and the results were then used to calculate the Biot coefficients for the two shale formations.The results showed that the samples have high OM porosity and 85%of the OM pores have the radius of less than 40 nm.The OM morphology and pore structure characteristics of the Longmaxi and Wufeng Formations were distinctly different.In particular,the OM in the Wufeng Formation samples developed some OM pores with radius larger than500 nm,which significantly improved the connectivity.The macroscopic permeability strongly depends on the permeability of OM pores.The stress sensitivity of permeability of Wufeng Formation was significantly lower than that of Longmaxi Formation,due to the differences in OM morphology and pore structures.The Biot coefficients of 0.729 and 0.697 were obtained for the Longmaxi and Wufeng Formations,respectively.
文摘It is very important to measure local deformations for an in-depth understanding of mechanical properties and fracture mechanism of structural and functional materials. In this paper, different types of model grid fabrication methods and many types of electron Moire methods using an electron beam drawing system, a scanning electron microscope or a focus ion beam are reported, together with their applications in the measurement of deformations occurring in various engineerings and materials science research.
文摘This study shows that submicron/nanoparticles found in bacterial cells (S. aureus) incubated with polyurethane (a material commonly used for prostheses in odontostomatology) are a consequence of biodestruction. The presence of polyurethane nanoparticles into bacterial vesicles suggests that the internalization process occurs through endocytosis. TEM and FIB/SEM are a suitable set of correlated instruments and techniques for this multi facet investigation: polyurethane particles influence the properties of S. aureus from the morpho-functional standpoint that may have undesirable effects on the human body. S. aureus and C. albicans are symbiotic microorganisms;it was observed that C. albicans has a similar interaction with polyurethane and an increment of the biodestruction capacity is expected by its mutual work with S. aureus.
基金supported by the Youth Innovation Promotion Association CAS(No.2016238)
文摘Background In the field of particle therapy,the method of pencil beam scanning is of great potential for clinical application,now and in the future.Purpose The authors made strong effort to develop a spot scanning system for Shanghai Proton Therapy Facility.Design parameters and basic layout of the system are introduced.Methods Functionalities and specifications of crucial devices are described in detail.Most of the devices in the system were designed in house by the authors themselves,including scanning nozzle,scanning magnets and their power supplies,beam monitors,irradiation control modules and safety interlock modules.During the technical commissioning stage in the fix beam room,the spot scanning system was tested and verified.Results Under conditions of the maximum dose rate and minimum dose rate,a)repeatability of the single spot dose is less than±0.1%;b)nonlinearity of the single spot dose is less than±0.1%;c)FWHM for spot size in air at isocenter varies from 8mm to 12mm for full energy,consistent with the design values;d)lateral dose distribution achieves a flatness of less than 2%for multiple proton energies.Conclusion According to the results of technical commissioning,the spot scanning system is capable of producing a pre-scribed 3D dose distribution for target tumor successfully.