期刊文献+
共找到6篇文章
< 1 >
每页显示 20 50 100
Scattering Centers Measurements by a Modified MEMP Method
1
作者 李世勇 孙厚军 +1 位作者 吕昕 胡伟东 《Journal of Beijing Institute of Technology》 EI CAS 2007年第4期448-454,共7页
A modified matrix enhancement and matrix pencil (MMEMP) method is presented for the scattering centers measurements in step-frequency radar. The method estimates the signal parameter pairs directly unlike the matrix e... A modified matrix enhancement and matrix pencil (MMEMP) method is presented for the scattering centers measurements in step-frequency radar. The method estimates the signal parameter pairs directly unlike the matrix enhancement and matrix pencil (MEMP) method which contains an additional step to pair the parameters related to each dimension. The downrange and crossrange expressions of the scattering centers are deduced, as well as the range ambiguities, from the point of view of MMEMP method. Compared with the Fourier transform method, the numerical simulation shows that both the resolution and precision of the MMEMP method are higher than those of the Fourier method. The processing results of the real measured data for three cylinders prove the above conclusions further. 展开更多
关键词 matrix enhancement and matrix pencil (MEMP) modified MEMP (MMEMP) scattering centers measurements step-frequency singular value decomposition (SVD)
下载PDF
High sampling-rate measurement of turbulence velocity fluctuations in Mach 1.8 Laval jet using interferometric Rayleigh scattering 被引量:4
2
作者 Li Chen Fu-Rong Yang +4 位作者 Tie Su Wei-Yi Bao Bo Yan Shuang Chen Ren-Bing Li 《Chinese Physics B》 SCIE EI CAS CSCD 2017年第2期341-344,共4页
Interferometric Rayleigh scattering diagnostic technique for the time-resolved measurement of flow velocity is studied. Theoretically, this systematic velocity-measured accuracy can reach up to 1.23 m/s. Measurement a... Interferometric Rayleigh scattering diagnostic technique for the time-resolved measurement of flow velocity is studied. Theoretically, this systematic velocity-measured accuracy can reach up to 1.23 m/s. Measurement accuracy is then evaluated by comparing with hot wire anemometry results. Moreover, the distributions of velocity and turbulence intensity in a supersonic free jet from a Laval nozzle with a Mach number of 1.8 are also obtained quantitatively. The sampling rate in this measurement is determined to be approximately 10 k Hz. 展开更多
关键词 Fabry–Pérot interferometer Rayleigh scattering time-resolved velocity measurement turbulence
下载PDF
Present Status of the Nd:YAG Thomson Scattering System Development for Time Evolution Measurement of Plasma Profile on Heliotron J
3
作者 Takashi MINAMI Shohei ARAI +12 位作者 Naoki KENMOCHI Hiroaki YASHIRO Chihiro TAKAHASHI Shinji KOBAYASHI Tohru MIZUUCHI Shinsuke OHSHIMA Satoshi YAMAMOTO Hiroyuki OKADA Kazunobu NAGASAKI Yuji NAKAMURA Kiyoshi HANATANI Shigeru KONOSHIMA Fumimichi SANO 《Plasma Science and Technology》 SCIE EI CAS CSCD 2013年第3期240-243,共4页
A new high repetition rate Nd:YAG Thomson scattering system is developed for the Heliotron J helical device. A main purpose of installing the new system is the temporal evolution measurement of a plasma profile for i... A new high repetition rate Nd:YAG Thomson scattering system is developed for the Heliotron J helical device. A main purpose of installing the new system is the temporal evolution measurement of a plasma profile for improved confinement physics such as the edge transport barrier (H-mode) or the internal transport barrier of the helical plasma. The system has 25 spatial points with -10 mm resolution. Two high repetition Nd:YAG lasers (〉 550 m J@ 50 Hz) realize the measurement of the time evolution of the plasma profile with ~10 ms time intervals. Scattered light is collected by a large concave mirror (D----800 mm, f/2.25) with a solid angle of -100 mstr and transferred to interference filter polychromators by optical fiber bundles in a staircase form. The signal is amplified by newly designed fast preamplifiers with DC and AC output, which reduces the low frequency background noise. The signals are digitized with a multi-event QDC, fast gated integrators. The data acquisition is performed by a VME-based system operated by the CINOS. 展开更多
关键词 plasma diagnostic Nd:YAG laser Thomson scattering measurement plasma improved confinement
下载PDF
Determination of bulk viscosity of liquid water via pulse duration measurements in stimulated Brillouin scattering 被引量:3
4
作者 葛媛 史久林 +1 位作者 朱开兴 何兴道 《Chinese Optics Letters》 SCIE EI CAS CSCD 2013年第11期110-114,共5页
We present a method by which to determine the bulk viscosity of water from pulse duration measurements of stimulated Brillouin scattering (SBS). Beginning from a common model of Brillouin scattering, the bulk viscos... We present a method by which to determine the bulk viscosity of water from pulse duration measurements of stimulated Brillouin scattering (SBS). Beginning from a common model of Brillouin scattering, the bulk viscosity is shown to play an important role in Brillouin linewidth determination. Pulse durations of SBS back-reflected optical pulses are measured over the temperature range of 5-40℃. SBS linewidths are de- termined via Fourier transformation of the time-domain results, and the bulk viscosity of water is measured and derived from the obtained values. Our results show that the proposed method for measurement of pulse durations is an effective approach for determining bulk viscosity. The method can be easily extended to determine bulk viscosities of other Newtonian liquids. 展开更多
关键词 SBS Determination of bulk viscosity of liquid water via pulse duration measurements in stimulated Brillouin scattering
原文传递
Inversion of particle size distribution from light-scattering data using a modified regularization algorithm 被引量:5
5
作者 Yanmin Wang Guobiao Liang Zhidong Pan 《Particuology》 SCIE EI CAS CSCD 2010年第4期365-371,共7页
A modified regularization algorithm with a more proper operator was proposed for the inversion of particle size distribution (PSD) from light-scattering data in a laser particle sizer based on the Mie scattering pri... A modified regularization algorithm with a more proper operator was proposed for the inversion of particle size distribution (PSD) from light-scattering data in a laser particle sizer based on the Mie scattering principle. The Generalized Cross-Validation (GCV) method and the L-curve method were used for deter- mining the regularization parameter. The Successive Over-Relaxation (SOR) iterative method was used to increase the exactness and stability of the converged result. The simulated results based on the modified algorithm are in a good agreement with the experimental data measured for nine standard particulate samples, their mixtures as well as three natural particulate materials with irregular shapes, indicating that this modified regularization method is not only feasible but also effective for the simulation of PSD from corresponding light-scattering data. 展开更多
关键词 Particle size measurement Mie scattering Laser particle size analyzerInverse algorithm
原文传递
The signal selection and processing method for polarization measurement radar 被引量:8
6
作者 CHANG YuLiang WANG XueSong LI YongZhen XIAO ShunPing 《Science in China(Series F)》 2009年第10期1926-1935,共10页
Based on the ambiguity function, a novel signal processing method for the polarization measurement radar is developed. One advantage of this method is that the two orthogonal polarized signals do not have to be perpen... Based on the ambiguity function, a novel signal processing method for the polarization measurement radar is developed. One advantage of this method is that the two orthogonal polarized signals do not have to be perpendicular to each other, which is required by traditional methods. The error due to the correlation of the two transmitting signals in the traditional method, can be reduced by this new approach. A concept called ambiguity function matrix (AFM) is introduced based on this method. AFM is a promising tool for the signal selection and design in the polarization scattering matrix measurement. The waveforms of the polarimetric radar are categorized and analyzed based on AFM in this paper. The signal processing flow of this method is explained. And the polarization scattering matrix measurement performance is testified by simulation. Furthermore, this signal processing method can be used in the inter-pulse interval measurement technique as well as in the instantaneous measurement technique. 展开更多
关键词 target polarization scattering matrix measurement of the polarization scattering matrix ambiguity function ambiguity function matrix polarimetric radar radar waveform radar signal processing
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部