Sirius Scheimpflug-Placido versus. ultrasound pachymetry for central corneal thickness: meta-analysis
1
作者 Yili Jin Colm McAlinden +8 位作者 Yong Sun Daizong Wen Yiran Wang Jinjin Yu Ke Feng Benhao Song Qinmei Wang Shihao Chen Jinhai Huang 《Eye and Vision》 SCIE CSCD 2023年第4期1-11,共11页
Background:To compare the difference in central corneal thickness(CCT)measurements in normal eyes between a rotating Scheimpflug camera combined with a Placido-disk corneal topographer(Sirius,CSO,Italy)and ultrasound ... Background:To compare the difference in central corneal thickness(CCT)measurements in normal eyes between a rotating Scheimpflug camera combined with a Placido-disk corneal topographer(Sirius,CSO,Italy)and ultrasound pachymetry(USP).Methods:A systematic literature search was conducted for relevant studies published on PubMed,Medline,EMBASE,and the Cochrane Library and ClinicalTrials.gov from inception to August 1st,2019.Primary outcome measures were CCT measurements between Sirius and USP.A random effects model was used to pool CCT measurements.Results:A total of twelve studies involving 862 eyes were included in this meta-analysis.The meta-analysis found CCT measurements between Sirius and USP to be statistically significantly different(P<0.0001).The mean difference between Sirius and USP was-11.26μm with a 95%confidence interval(CI)(-16.92μm,-5.60μm).The heterogeneity Was IP=60%(P=0.004).Conclusion:CCT measurements with the Sirius Scheimpflug-Placido topographer were statistically significantly lower than USP.However,it may be argued that the mean difference of 11.26μm is not a clinically significant difference. 展开更多
关键词 Meta-analysis Central corneal thickness scheimpflug-placido topographer Ultrasound pachymetry
原文传递
Comparison of central corneal thickness measurements with three new optical devices and a standard ultrasonic pachymeter 被引量:8
2
作者 Hasan Ali Bayhan Seray Aslan Bayhan Iz.zet Can 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2014年第2期302-308,共7页
AIM:To compare the RTVue spectral optical coherence tomography(SD-OCT),Sirius Scheimpflug-Placido topographer,Lenstar optical low coherence reflectometry(OLCR)and ultrasound pachymetry(USP)devices in terms of their ag... AIM:To compare the RTVue spectral optical coherence tomography(SD-OCT),Sirius Scheimpflug-Placido topographer,Lenstar optical low coherence reflectometry(OLCR)and ultrasound pachymetry(USP)devices in terms of their agreement and repeatability of measuring central corneal thickness(CCT).METHODS:In this prospective study,50 eyes of 50patients were included.Three repeated measures were obtained using SD-OCT,Scheimpflug-Placido topographer and USP and five measurements were determined with the OLCR.Bland-Altman plots were used to assess agreement among the instruments,and 95%limits of agreement(LoA)for each comparison were calculated.Intra-examiner repeatability was assessed using intraclass correlation coefficients(ICCs).RESULTS:The mean CCT by SD-OCT,ScheimpflugPlacido topographer,OLCR,and USP were 525.90±34.08μm,525.92±34.10μm,530.30±35.62μm,and543.50±37.11μm respectively.All 4 modalities of CCT measurements correlated closely with each other,with Pearson correlation coefficients ranging from 0.977 to0.995.The mean differences(and upper/lower LoA)for CCT measurements were-0.05±6.77μm(13.3/-13.3)between SD-OCT and Scheimpflug-Placido topographer,4.38±3.79μm(11.8/-3.1)between OLCR and SD-OCT,4.38±6.03μm(16.2/-7.5)between OLCR and ScheimpflugPlacido topographer,13.20±6.46μm(25.9/0.5)between USP and OLCR,17.59±6.76μm(30.8/4.3)between USP and SD-OCT,and 17.58±8.13μm(33.5/1.6)between USP and Scheimpflug-Placido topographer.Intra-examiner repeatability was excellent for all devices with ICCs】0.98.CONCLUSION:For most practical purposes,CCT measurements with the RTVue,Sirius and Lenstar can be used interchangeably.Although highly correlated,CCTmeasurement differences between USP and these 3optical instruments can be significant depending on the clinical situation. 展开更多
关键词 central corneal thickness optical low coherence reflectometry spectral optical coherence tomography scheimpflug-placido topographer
下载PDF
Placido disk-based topography versus high-resolution rotating Scheimpflug camera for corneal power measurements in keratoconic and post-LASIK eyes:reliability and agreement 被引量:2
3
作者 Rachele R.Penna Ugo de Sanctis +2 位作者 Martina Catalano Luca Brusasco Federico M.Grignolo 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2017年第3期453-460,共8页
AIM:To compare the repeatability/reproducibility of measurement by high-resolution Placido disk-based topography with that of a high-resolution rotating Scheimpflug camera and assess the agreement between the two ins... AIM:To compare the repeatability/reproducibility of measurement by high-resolution Placido disk-based topography with that of a high-resolution rotating Scheimpflug camera and assess the agreement between the two instruments in measuring corneal power in eyes with keratoconus and post-laser in situ keratomileusis(LASIK). METHODS:One eye each of 36 keratoconic patients and 20 subjects who had undergone LASIK was included in this prospective observational study. Two independent examiners worked in a random order to take three measurements of each eye with both instruments. Four parameters were measured on the anterior cornea:steep keratometry(Ks),flat keratometry(Kf),mean keratometry(Km),and astigmatism(Ks-Kf). Intra-examiner repeatability and inter-examiner reproducibility were evaluated by calculating the within-subject standard deviation(Sw)the coefficient of repeatability(R),the coefficient of variation(Co V),and the intraclass correlation coefficient(ICC). Agreement between instruments was tested with the BlandAltman method by calculating the 95% limits of agreement(95% Lo A).RESULTS:In keratoconic eyes,the intra-examiner and inter-examiner ICC were 〉0.95. As compared with measurement by high-resolution Placido disk-based topography,the intra-examiner R of the high-resolution rotating Scheimpflug camera was lower for Kf(0.32 vs 0.88),Ks(0.61 vs 0.88),and Km(0.32 vs 0.84)but higher for Ks-Kf(0.70 vs 0.57). Inter-examiner R values were lower for all parameters measured using the high-resolution rotating Scheimpflug camera. The 95% Lo A were-1.28 to +0.55 for Kf,-1.36 to +0.99 for Ks,-1.08 to +0.50 for Km,and-1.11 to +1.48 for Ks-Kf. In the post-LASIK eyes,the intra-examiner andinter-examiner ICC were 〉0.87 for all parameters. The intra-examiner and inter-examiner R were lower for all parameters measured using the high-resolution rotating Scheimpflug camera. The intra-examiner R was 0.17 vs 0.88 for Kf,0.21 vs 0.88 for Ks,0.17 vs 0.86 for Km,and 0.28 vs 0.33 for Ks-Kf. The inter-examiner R was 0.09 vs 0.64 for Kf,0.15 vs 0.56 for Ks,0.09 vs 0.59 for Km,and 0.18 vs 0.23 for Ks-Kf. The 95% Lo A were-0.54 to +0.58 for Kf,-0.51 to +0.53 for Ks and Km,and-0.28 to +0.27 for Ks-Kf. CONCLUSION:As compared with Placido disk-based topography,the high-resolution rotating Scheimpflug camera provides more repeatable and reproducible measurements of Ks,Kf and Ks in keratoconic and post-LASIK eyes. Agreement between instruments is fair in keratoconus and very good in post-LASIK eyes. 展开更多
关键词 keratoconus post-LASIK corneal power measurement Placido disk-based topography Scheimpflug camera
下载PDF
Sirius Scheimpflug–Placido versus ultrasound pachymetry for central corneal thickness:meta-analysis 被引量:1
4
作者 Yili Jin Colm McAlinden +8 位作者 Yong Sun Daizong Wen Yiran Wang Jinjin Yu Ke Feng Benhao Song Qinmei Wang Shihao Chen Jinhai Huang 《Eye and Vision》 SCIE CSCD 2021年第1期36-46,共11页
Background:To compare the difference in central corneal thickness(CCT)measurements in normal eyes between a rotating Scheimpflug camera combined with a Placido-disk corneal topographer(Sirius,CSO,Italy)and ultrasound ... Background:To compare the difference in central corneal thickness(CCT)measurements in normal eyes between a rotating Scheimpflug camera combined with a Placido-disk corneal topographer(Sirius,CSO,Italy)and ultrasound pachymetry(USP).Methods:A systematic literature search was conducted for relevant studies published on PubMed,Medline,EMBASE,and the Cochrane Library and ClinicalTrials.gov from inception to August 1st,2019.Primary outcome measures were CCT measurements between Sirius and USP.A random effects model was used to pool CCT measurements.Results:A total of twelve studies involving 862 eyes were included in this meta-analysis.The meta-analysis found CCT measurements between Sirius and USP to be statistically significantly different(P<0.0001).The mean difference between Sirius and USP was−11.26μm with a 95%confidence interval(CI)(−16.92μm,−5.60μm).The heterogeneity was I^(2)=60%(P=0.004).Conclusion:CCT measurements with the Sirius Scheimpflug-Placido topographer were statistically significantly lower than USP.However,it may be argued that the mean difference of 11.26μm is not a clinically significant difference. 展开更多
关键词 META-ANALYSIS Central corneal thickness scheimpflug-placido topographer Ultrasound Pachymetry
原文传递