Focusing on the extending length restriction of the completion screen pipe resistance running into ultra-short radius horizontal well,this paper proposed technology of hydraulic drive completion tubular string running...Focusing on the extending length restriction of the completion screen pipe resistance running into ultra-short radius horizontal well,this paper proposed technology of hydraulic drive completion tubular string running into ultra-short radius horizontal well.Innovative hydraulic drive tools and string structure are designed,which are composed of guide tubing,hydraulic drive tubing and non-metallic completion screen pipe from inside to outside.A novel mechanical-hydraulic coupling model is established.Based on the wellbore structure of an ultra-short radius horizontal well for deep coalbed methane,the numerical calculations of force and hydraulic load on tubular strings were accomplished by the mechanical-hydraulic coupling model.The results show that the extending length of completion tubular string with the hydraulic drive is 17 times that of conventional completion technology under the same conditions.The multi-factor orthogonal design is adopted to analyze the numerical calculations,and the results show that the extending length of the completion tubular string is mainly affected by the completion tubular string structure and the friction coefficient between the non-metallic composite continuous screen pipe and the wellbore.Two series of hydraulic drive completion tubular string structures suitable for ultra-short radius horizontal wells under different conditions are optimized,with the extending limits of 381 m and 655 m,respectively.These researches will provide theoretical guidance for design and control of hydraulic drive non-metallic composite continuous completion screen pipe running into ultra-short radius horizontal wells.展开更多
The objective of the present experimental work is to investigate the performance of a wrapped screen heat pipe for atmospheric air heating to compare with the limits of this pipe. The experiment was conducted using co...The objective of the present experimental work is to investigate the performance of a wrapped screen heat pipe for atmospheric air heating to compare with the limits of this pipe. The experiment was conducted using copper pipe material and acetone as working fluid at different vapor temperatures. The testing also consists of a heater, a blower for heat removal (condenser), temperature measuring device, a vapor temperature probe, acetone charging system, and a vacuum pump. The copper outside diameterof the pipe is 0.022 m, with a total length of 0.6 m. The results showed that the pipe wall temperature (Tw) for a wrapped screen heat pipe has a rapid increase and takes 50 min to reach steady state at (Q = 63 W). The vapour temperature of working fluid increases as the heat load increases at constant air velocity. It was also been found that the range of vapour temperature deceases as the filling ratio increases that means the increasing of the filling ratio results the decrease of the maximum vapour temperature and the variation in the vapour temperature. The best recorded filling ratio is 0.6 which has the lowest vapour temperature at highest heat load. The maximum heat transport limit for this pipe is 80 W and the maximum temperature difference for air is 5。C.展开更多
基金Supported by the Innovative Research Group Project of China National Natural Science Foundation(51821092)Key Project of China National Natural Science Foundation(U1762214).
文摘Focusing on the extending length restriction of the completion screen pipe resistance running into ultra-short radius horizontal well,this paper proposed technology of hydraulic drive completion tubular string running into ultra-short radius horizontal well.Innovative hydraulic drive tools and string structure are designed,which are composed of guide tubing,hydraulic drive tubing and non-metallic completion screen pipe from inside to outside.A novel mechanical-hydraulic coupling model is established.Based on the wellbore structure of an ultra-short radius horizontal well for deep coalbed methane,the numerical calculations of force and hydraulic load on tubular strings were accomplished by the mechanical-hydraulic coupling model.The results show that the extending length of completion tubular string with the hydraulic drive is 17 times that of conventional completion technology under the same conditions.The multi-factor orthogonal design is adopted to analyze the numerical calculations,and the results show that the extending length of the completion tubular string is mainly affected by the completion tubular string structure and the friction coefficient between the non-metallic composite continuous screen pipe and the wellbore.Two series of hydraulic drive completion tubular string structures suitable for ultra-short radius horizontal wells under different conditions are optimized,with the extending limits of 381 m and 655 m,respectively.These researches will provide theoretical guidance for design and control of hydraulic drive non-metallic composite continuous completion screen pipe running into ultra-short radius horizontal wells.
文摘The objective of the present experimental work is to investigate the performance of a wrapped screen heat pipe for atmospheric air heating to compare with the limits of this pipe. The experiment was conducted using copper pipe material and acetone as working fluid at different vapor temperatures. The testing also consists of a heater, a blower for heat removal (condenser), temperature measuring device, a vapor temperature probe, acetone charging system, and a vacuum pump. The copper outside diameterof the pipe is 0.022 m, with a total length of 0.6 m. The results showed that the pipe wall temperature (Tw) for a wrapped screen heat pipe has a rapid increase and takes 50 min to reach steady state at (Q = 63 W). The vapour temperature of working fluid increases as the heat load increases at constant air velocity. It was also been found that the range of vapour temperature deceases as the filling ratio increases that means the increasing of the filling ratio results the decrease of the maximum vapour temperature and the variation in the vapour temperature. The best recorded filling ratio is 0.6 which has the lowest vapour temperature at highest heat load. The maximum heat transport limit for this pipe is 80 W and the maximum temperature difference for air is 5。C.