期刊文献+
共找到361篇文章
< 1 2 19 >
每页显示 20 50 100
Additive manufactured osseointegrated screws with hierarchical design
1
作者 Wenbo Yang Hao Chen +6 位作者 Haotian Bai Yifu Sun Aobo Zhang Yang Liu Yuchao Song Qing Han Jincheng Wang 《Bio-Design and Manufacturing》 SCIE EI CAS CSCD 2024年第2期206-235,共30页
Bone screws are devices used to fix implants or bones to bones.However,conventional screws are mechanically fixed with thread and often face long-term failure due to poor osseointegration.To improve osseointegration,s... Bone screws are devices used to fix implants or bones to bones.However,conventional screws are mechanically fixed with thread and often face long-term failure due to poor osseointegration.To improve osseointegration,screws are evolving from solid and smooth to porous and rough.Additive manufacturing(AM)offers a high degree of manufacturing freedom,enabling the preparation of predesigned screws that are porous and rough.This paper provides an overview of the problems currently faced by bone screws:long-term loosening and screw breakage.Next,advances in osseointegrated screws are summarized hierarchically(sub-micro,micro,and macro).At the sub-microscale level,we describe surface-modification techniques for enhancing osseointegration.At the micro level,we summarize the micro-design parameters that affect the mechanical and biological properties of porous osseointegrated screws,including porosity,pore size,and pore shape.In addition,we highlight three promising pore shapes:triply periodic minimal surface,auxetic structure with negative Poisson ratio,and the Voronoi structure.At the macro level,we outline the strategies of graded design,gradient design,and topology optimization design to improve the mechanical strength of porous osseointegrated screws.Simultaneously,this paper outlines advances in AM technology for enhancing the mechanical properties of porous osseointegrated screws.AM osseointegrated screws with hierarchical design are expected to provide excellent long-term fixation and the required mechanical strength. 展开更多
关键词 Bone screws Additive manufacturing Architecture design Surface modification
下载PDF
Biomechanical effects of posterior lumbar interbody fusion with vertical placement of pedicle screws compared to traditional placement
2
作者 Ji-Hong Jiang Chang-Ming Zhao +2 位作者 Jun Zhang Rong-Ming Xu Lei Chen 《World Journal of Clinical Cases》 SCIE 2024年第20期4108-4120,共13页
BACKGROUND The pedicle screw technique is widely employed for vertebral body fixation in the treatment of spinal disorders.However,traditional screw placement methods require the dissection of paraspinal muscles and t... BACKGROUND The pedicle screw technique is widely employed for vertebral body fixation in the treatment of spinal disorders.However,traditional screw placement methods require the dissection of paraspinal muscles and the insertion of pedicle screws at specific transverse section angles(TSA).Larger TSA angles require more force to pull the muscle tissue,which can increase the risk of surgical trauma and ischemic injury to the lumbar muscles.AIM To study the feasibility of zero-degree TSA vertical pedicle screw technique in the lumbosacral segment.METHODS Finite element models of vertebral bodies and pedicle screw-rod systems were established for the L4-S1 spinal segments.A standard axial load of 500 N and a rotational torque of 10 N/m were applied.Simulated screw pull-out experiment was conducted to observe pedicle screw resistance to pull-out,maximum stress,load-displacement ratio,maximum stress in vertebral bodies,load-displacement ratio in vertebral bodies,and the stress distribution in pedicle screws and vertebral bodies.Differences between the 0-degree and 17-degree TSA were compared.RESULTS At 0-degree TSA,the screw pull-out force decreased by 11.35%compared to that at 17-degree TSA(P<0.05).At 0-degree and 17-degree TSA,the stress range in the screw-rod system was 335.1-657.5 MPa and 242.8-648.5 MPa,separately,which were below the fracture threshold for the screw-rod system(924 MPa).At 0-degree and 17-degree TSA,the stress range in the vertebral bodies was 68.45-78.91 MPa and 39.08-72.73 MPa,separately,which were below the typical bone yield stress range for vertebral bodies(110-125 MPa).At 0-degree TSA,the load-displacement ratio for the vertebral bodies and pedicle screws was slightly lower compared to that at 17-degree TSA,indicating slightly lower stability(P<0.05).CONCLUSION The safety and stability of 0-degree TSA are slightly lower,but the risks of screw-rod system fracture,vertebral body fracture,and rupture are within acceptable limits. 展开更多
关键词 Vertical pedicle screw Pedicle screw technique Transverse section angle Lumbosacral segment Finite element analysis
下载PDF
Comparative efficacy of proximal femoral nail vs dynamic condylar screw in treating unstable intertrochanteric fractures
3
作者 Ahmed Mohamed Yousif Mohamed Monzir Salih +2 位作者 Mohanad Abdulgadir Ayman E Abbas Duha Lutfi Turjuman 《World Journal of Orthopedics》 2024年第8期796-806,共11页
BACKGROUND Among the most frequent hip fractures are trochanteric fractures,which usually occur from low-energy trauma like minor falls,especially in older people with osteoporotic bones.AIM To evaluate the treatment ... BACKGROUND Among the most frequent hip fractures are trochanteric fractures,which usually occur from low-energy trauma like minor falls,especially in older people with osteoporotic bones.AIM To evaluate the treatment efficacy of dynamic condylar screws(DCS)and proximal femoral nails(PFN)for unstable intertrochanteric fractures.METHODS To find pertinent randomized controlled trials and retrospective observational studies comparing PFN with DCS for the management of unstable femoral intertrochanteric fractures,a thorough search was carried out.For research studies published between January 1996 and April 2024,PubMed,EMBASE,Scopus,Web of Science,Cochrane Library,and Google Scholar were all searched.The complete texts of the papers were retrieved,vetted,and independently examined by two investigators.Disputes were settled by consensus,and any disagreements that persisted were arbitrated by a third author.RESULTS This study included six articles,comprising a total of 173 patients.Compared to the DCS,the PFN had a shorter operation time[mean difference(MD):-41.7 min,95%confidence interval(95%CI):-63.04 to-20.35,P=0.0001],higher success rates with closed reduction techniques[risk ratio(RR):34.05,95%CI:11.12-104.31,P<0.00001],and required less intraoperative blood transfusion(MD:-1.4 units,95%CI:-1.80 to-1.00,P<0.00001).Additionally,the PFN showed shorter fracture union time(MD:-6.92 wk,95%CI:-10.27 to-3.57,P<0.0001)and a lower incidence of reoperation(RR:0.37,95%CI:0.17-0.82,P=0.01).However,there was no discernible variation regarding hospital stay,implant-related complications,and infections.CONCLUSION Compared to DCS,PFN offers shorter operative times,reduces the blood transfusions requirements,achieves higher closed reduction success,enables faster fracture healing,and lowers reoperation incidence. 展开更多
关键词 Intertrochanteric fracture UNSTABLE Dynamic condylar screw Proximal femoral nail META-ANALYSIS Comparative study
下载PDF
Roller Screw and Threaded Chain Speed Reducer: An Experimental Evaluation
4
作者 Filiberto Gutiérrez 《Modern Mechanical Engineering》 2024年第1期1-11,共11页
We are developing a speed reducer that can be considered a transformation of a worm gear reducer: the worm is replaced by an inverted roller screw, and the gear is replaced by a threaded chain drive. This configuratio... We are developing a speed reducer that can be considered a transformation of a worm gear reducer: the worm is replaced by an inverted roller screw, and the gear is replaced by a threaded chain drive. This configuration lessens wear, increases load capacity, and improves efficiency. The threaded chain consists of nut-shaped links. This paper presents the results of tests carried out on a prototype with a reduction ratio of 46. 展开更多
关键词 Speed Reducer Inverted Roller screw Chain Drive Threaded Chain Drive
下载PDF
Clinical Effectiveness of the Plate Screw Internal Fixation Technique in the Treatment of Patients with Traumatic Fractures of Long Bones in the Lower Extremities
5
作者 Yong Cai 《Proceedings of Anticancer Research》 2024年第3期115-120,共6页
Objective: To investigate the effectiveness of the plate screw internal fixation technique on the clinical outcomes of patients with traumatic fractures of long bones in the lower extremities. Methods: From January 20... Objective: To investigate the effectiveness of the plate screw internal fixation technique on the clinical outcomes of patients with traumatic fractures of long bones in the lower extremities. Methods: From January 2022 to December 2023, 70 patients with traumatic fractures of long bones in the lower extremities were admitted to the hospital and randomly divided into two groups: the control group and the observation group, each consisting of 35 cases. The control group underwent traditional closed interlocking intramedullary nailing, while the observation group received internal fixation with steel plates and screws. Relevant surgical indicators, treatment effectiveness, and postoperative complication rates were compared between the two groups. Results: The observation group exhibited significantly short surgical duration (80.65 ± 5.01 vs. 88.36 ± 5.26 minutes), fracture healing time (13.27 ± 0.32 vs. 15.52 ± 0.48 weeks), and hospitalization days (10.49 ± 1.13 vs. 16.57 ± 1.15 days) compared to the control group (P = 0.000). The effective treatment rate was significantly higher in the observation group (29/82.86%) than in the control group (21/60.00%), with a significant difference observed (χ2 = 4.480, P = 0.034). Additionally, the complication rate in the observation group (2/5.71%) was significantly lower than that in the control group (8/22.86%), with a correlated difference (χ2 = 4.200, P = 0.040). Conclusion: The plate screw internal fixation technique demonstrates significant clinical efficacy in treating traumatic fractures of long bones in the lower extremities. It improves the healing rate, reduces complications, and represents a safe and effective treatment strategy worthy of widespread use and application. 展开更多
关键词 Plate screw internal fixation technique Traumatic fractures Long bones in the lower extremities EFFECTIVENESS
下载PDF
Distal clavicle fractures treated by anteroinferior plating with a single screw: Two case reports 被引量:1
6
作者 Xin-Lei Zhao Yan-Qing Liu +4 位作者 Jian-Guo Wang You-Cai Liu Jia-Xuan Zhou Bei-Yu Wang Yi-Jun Zhang 《World Journal of Clinical Cases》 SCIE 2023年第30期7502-7507,共6页
BACKGROUND For the treatment of distal clavicle fractures,each treatment method has its own advantages and disadvantages,and there is no optimal surgical solution.CASE SUMMARY Based on this,we report 2 cases of distal... BACKGROUND For the treatment of distal clavicle fractures,each treatment method has its own advantages and disadvantages,and there is no optimal surgical solution.CASE SUMMARY Based on this,we report 2 cases of distal clavicle fractures treated utilizing an anterior inferior plate with a single screw placed in the distal,in anticipation of providing a better surgical approach to distal clavicle fracture treatment.Two patients were admitted to the hospital after trauma with a diagnosis of distal clavicle fracture,and were admitted to the hospital for internal fixation of clavicle fracture by incision and reduction,with good postoperative functional recovery.CONCLUSION With solid postoperative fixation and satisfactory prognostic functional recovery,this technique has been shown to be simple,easy to perform and effective. 展开更多
关键词 Distal clavicle fractures Anteroinferior PLATING Single screw Case report
下载PDF
Gravity-Based Kinetostatic Modeling of Parallel Manipulators Using Screw Theory
7
作者 Chao Yang Fengli Huang +1 位作者 Wei Ye Qiaohong Chen 《Chinese Journal of Mechanical Engineering》 SCIE EI CAS CSCD 2023年第6期73-86,共14页
The pose accuracy of parallel manipulators(PMs)is a key index to measure their performance.Establishing the grav-ity-based kinetostatic model of a parallel robot provides an important basis for its error composition a... The pose accuracy of parallel manipulators(PMs)is a key index to measure their performance.Establishing the grav-ity-based kinetostatic model of a parallel robot provides an important basis for its error composition and accuracy improvement.In this paper,a kinetostatic modeling approach that takes real gravity distribution into consideration is proposed to analyze the influence of gravity on the infinitesimal twist and actuator forces of PMs.First,the duality of the twist screw and constraint wrenches are used to derive the gravity-attached constraint wrenches independent of the external load and the limb stiffness matrix corresponding to the kinematics-based constraint wrenches.Sec-ond,the gravity model of the mechanism is established based on the screw theory and the principle of virtual work.Finally,the analytical formulas of the infinitesimal twist and the actuator force of PMs are obtained,and the influences of the external load,platform gravity,and rod gravity on the stiffness of the mechanism are decoupled.The non-overconstrained 3RPS and overconstrained 2PRU-UPR PMs are taken as examples to verify the proposed method.This research proposes a methodology to analyze the infinitesimal deformation of the mechanism under the influence of gravity. 展开更多
关键词 Parallel manipulator Kinetostatic model GRAVITY screw theory
下载PDF
Multitrack and multianchor point screw technique combined with the Wiltse approach for lesion debridement for lumbar tuberculosis
8
作者 Yu-Fei Yuan Zhi-Xin Ren +5 位作者 Cun Zhang Guan-Jun Li Bing-Zhi Liu Xiao-Dong Li Jie Miao Jian-Fei Li 《World Journal of Clinical Cases》 SCIE 2023年第14期3167-3175,共9页
BACKGROUND The incidence of lumbar tuberculosis is high worldwide,and effective treatment is a continuing problem.AIM To study the safety and efficacy of the multitrack and multianchor point screw technique combined w... BACKGROUND The incidence of lumbar tuberculosis is high worldwide,and effective treatment is a continuing problem.AIM To study the safety and efficacy of the multitrack and multianchor point screw technique combined with the contralateral Wiltse approach for lesion debridement to treat lumbar tuberculosis.METHODS The C-reactive protein(CRP)level,erythrocyte sedimentation rate(ESR),visual analogue scale(VAS)score,oswestry disability index(ODI)and American Spinal Injury Association(ASIA)grade were recorded and analysed pre-and postoperatively.RESULTS The CRP level and ESR returned to normal,and the VAS score and ODI were decreased at 3 mo postoperatively,with significant differences compared with the preoperative values(P<0.01).Neurological dysfunction was relieved,and the ASIA grade increased,with no adverse events.CONCLUSION The multitrack,multianchor point screw fixation technique combined with the contralateral Wiltse approach for debridement is an effective and safe method for the treatment of lumbar tuberculosis. 展开更多
关键词 Lumbar spine TUBERCULOSIS DEBRIDEMENT Pedicle screw Cortical bone trajectory screw Wiltse approach
下载PDF
Experimental Investigation on the Strength and Ductility Performance of Steel-Timber-Steel Joints with Screw and Steel-Tube Fasteners
9
作者 Huifeng Yang Mingwang Wu +3 位作者 Rixin Gu Hang Cao Kai Xiao Benkai Shi 《Journal of Renewable Materials》 EI 2023年第12期4175-4195,共21页
This article presents experimental results of steel-timber-steel(STS)joints loaded parallel to grain.Eight groups of specimens were designed,and tensile tests were performed.The fastener types and fastener numbers wer... This article presents experimental results of steel-timber-steel(STS)joints loaded parallel to grain.Eight groups of specimens were designed,and tensile tests were performed.The fastener types and fastener numbers were considered to evaluate the tensile strengths and ductility performances of the STS joints.The screws with 6 mm diameter and the innovative steel-tubes with 18 mm diameter were adopted as connecting fasteners.The experimental results were discussed in terms of yielding and ultimate strengths,slip stiffness,and ductility factors.The ductility classification and failure mechanisms of each group of specimens were analyzed.It was demonstrated that the STS joint with large diameter steel-tubes showed acceptable ductility,which was close to the ductility of the STS joint with small diameter screws,thanks to the hollow structure of the steel-tube.The theoretical strengths of various failure modes for the joints with small diameter screws or large diameter steel-tubes were calculated and compared with the experimental results.The ductile performance of the STS joint was discussed by comparing the theoretical strengths of various failure modes.The effective number of the STS joint with multifasteners was also analyzed by considering the failure mechanisms in aspects of tensile strength and slip stiffness. 展开更多
关键词 Steel-timber-steel joint screw steel-tube DUCTILITY experimental investigation timber structure
下载PDF
Nail Holding Performance of Self-Tapping Screws on Masson Pine and Chinese Fir Dimension Lumbers
10
作者 De Li Bengang Zhang +7 位作者 Yuan Tu Guoming Xiao Meifen Tian Xiaoxue Xu Xiao Zhong Qiaoyan Zhang Zhigang Wu Jiankun Liang 《Journal of Renewable Materials》 EI 2023年第10期3725-3738,共14页
Screw connection is a type most commonly applied to timber structures.As important commercial tree species in China,Masson pine and Chinese fir have the potential to prepare wood structures.In this study,the effects o... Screw connection is a type most commonly applied to timber structures.As important commercial tree species in China,Masson pine and Chinese fir have the potential to prepare wood structures.In this study,the effects of the diameter of the self-tapping screw and the guiding bores on the nail holding performance on different sections of Masson pine and Chinese fir dimension lumbers were mainly explored.The results showed that:(1)The nail holding strength of the tangential section was the maximum,followed by that of the radial section,and that of the cross section was the minimum.(2)The nail holding strength of Masson pine was higher than that of Chinese fir.(3)The nail holding strength grew with the increase in the diameter of self-tapping screws,but a large diameter would lead to plastic cracking of the timber,thus further affecting the nail holding strength.Masson pine and Chinese fir reached the maximum nail holding strength when the diameter of self-tapping screws was 3.5 mm.(4)Under a large diameter of screws,prefabricated guiding bores could mitigate timber cracking and improve its nail holding strength.(5)Prefabricated guiding bores were more necessary for the screw connection of Masson pine.The results obtained could provide a scientific basis for the screw connection design of Masson pine and Chinese fir timber structures. 展开更多
关键词 Masson pine Chinese fir self-tapping screws nail holding performance
下载PDF
Research and experimental analysis of precision degradation method based on the ball screw mechanism
11
作者 孔德顺 GAO Xiangsheng JIANG Huizeng 《High Technology Letters》 EI CAS 2023年第3期247-256,共10页
As a key transmission component in computer numerical control(CNC) machine tools,the ball screw mechanism(BSM) is usually investigated under working load conditions. Its accuracy degradation process is relatively long... As a key transmission component in computer numerical control(CNC) machine tools,the ball screw mechanism(BSM) is usually investigated under working load conditions. Its accuracy degradation process is relatively long,which is not conducive to the design and development of new products. In this paper,the normal wear depth of the BSM nut raceway is calculated under the variable speed operation condition using the fractal wear analysis method and the BSM’s accelerated degradation proportional wear model. Parameters of the acceleration degradation model of the double-nut preloaded ball screw pair are calculated based on the physical simulation results. The accelerated degradation test platform of the BSM is designed and manufactured to calculate the raceway wear model when the lubrication condition is broken under the variable-speed inertial load and the boundary lubrication condition under the uniform speed state. Three load forces and two samples are selected for the accelerated degradation test of the BSM. The measured friction torque of the BSM is employed as the evaluation index of the accuracy degradation test. In addition,the life cycle of the accuracy retention is accurately calculated by employing the parameters of the physical simulation model of the BSM. The calculations mentioned above can be used to estimate BSM’s accuracy performance degradation law under normal operating conditions. The application of the proposed model provides a new research method for researching the precision retention of the BSM. 展开更多
关键词 ball screw mechanism(BSM) fractal theory wear model accelerated degradation method friction torque precision retention
下载PDF
Accuracy of screw placement in the apical region of Lenke 1 adolescent idiopathic scoliosis surgery using a calibration technique for the intraoperative navigation error
12
作者 CHEN Huan-xiong HE Xian-bo +6 位作者 LI Guo-jun TANG Song-jie ZHONG Zhen-hao HUANG Tao LIN You-cai LIN Su-yu MENG Zhi-bin 《Journal of Hainan Medical University》 CAS 2023年第6期43-50,共8页
Objective:To study the position and the grade of screw perforation in the apical region of adolescent idiopathic scoliosis(AIS)surgery using a calibration technique for the intraoperative navigation error,and to analy... Objective:To study the position and the grade of screw perforation in the apical region of adolescent idiopathic scoliosis(AIS)surgery using a calibration technique for the intraoperative navigation error,and to analyze the related factors of navigation deviation and the clinical significance of the calibration technique.Methods:From 2017 to 2020,a total of 60 Lenke 1 AIS surgical cases were enrolled in this research.The 30 cases received surgery using the intraoperative navigation system(Navigation group)and another 30 cases were assisted with intraoperative navigation system with calibration technique(Calibration group)for the intraoperative navigation error.The basic information and radiological data of the both groups were all recorded.According to the Fu Chang-feng’s pedicle channel classification system,the pedicle on the apical region of the two groups was classified.And then the accuracy of screw placement of the two groups was evaluated according to the Rao’s classification.Results:A total of 600 screws were placed in the two groups.The 297 and 303 pedicle screws were implanted in the navigation group and the calibration group,respectively.In the apical region of the calibration group,the rates of the grade 0 screw placement in type A,B and C pedicle were 95.7%,86.7%and 68.9%respectively.It was a statistically significant difference from the 73.9%,66.9%and 30.0%in the navigation group respectively(P<0.05).In the calibration group,the rates of the medial cortical perforation in the type A,B,C and D pedicle were 0%,1.6%,1.6%and 0%,respectively.The corresponding rates were 16.3%,16.9%,30.0%and 47.6%in the navigation group,respectively.Moreover,in the concave side of the apical region of the calibration group,the rates of the medial cortical perforation in the type A,B,C and D pedicle were 0%,3.6%,2.6%and 0%,respectively.Compared with the calibration group,the corresponding rates were higher in the navigation group(34.4%,25.9%,37.2%and 60.0%,respectively).No serious complications such as spinal cord or neurovascular injury occurred for the two groups.Conclusion:Compared with the intraoperative navigation system,the calibration technique for the intraoperative navigation error could provide the higher accuracy of pedicle screw placement in the apical region of the major curve,the lower medial cortical perforation rate,the less screws misplacement rate on the concave side and the less complication rate of the severe Lenke 1 AIS patients. 展开更多
关键词 Adolescent idiopathic scoliosis Apical region Pedicle channel classification Pedicle screw Navigation error
下载PDF
Management of Isolated Coronal Fractures of Distal Humeral Epiphysis by Herbert Screw
13
作者 Yassine Ben Bouzid Rida-Allah Bassir +4 位作者 Monsef Boufettal Jalal Mekkaoui Mohamed Kharmaz Moulay Omar Lamrani Mohamed Saleh Berrada 《Open Journal of Orthopedics》 2023年第2期50-54,共5页
Isolated fractures of the distal humerus are rare. Their diagnosis is often late, and treatment has progressed but serious complications may occur. We conducted a retrospective study of a series of 10 cases at the Dep... Isolated fractures of the distal humerus are rare. Their diagnosis is often late, and treatment has progressed but serious complications may occur. We conducted a retrospective study of a series of 10 cases at the Department of Orthopedic and Traumatologic Surgery of the Ibn Sina University Hospital in Rabat over a 4-year period, from January 2018 to January 2022. All our cases were treated surgically with Herbert screws. The functional, clinical and radiological outcome was satisfactory with a return to pre-fracture activity in all patients. 展开更多
关键词 Elbow CAPITELLUM Herbert screw
下载PDF
Crossed Intralaminar Screws for Fusion of the Cervicothoracic Junction and the Thoracic Spine: The Experience in an Iberic Service with Case Series and Review of the Current Literature with Technique Description
14
作者 Marcel Sincari Margarida Conceição 《Surgical Science》 2023年第3期203-220,共18页
The treatment of pathologies in the thoracic spine is a challenge. The periodic failure of pedicle screw insertion and anatomical variations make the search for an alternative to pedicle screws in thoracic spine surge... The treatment of pathologies in the thoracic spine is a challenge. The periodic failure of pedicle screw insertion and anatomical variations make the search for an alternative to pedicle screws in thoracic spine surgery necessary. The interlaminar crossed screws is a well-known and secure method for fusion in cervical spine, and in thoracic spine there used to be insufficient clinical data to support this technique, until now. We demonstrate in an initial series of 10 cases treated with interlaminar fusion in association of other fusion techniques in the thoracic spine with good results. Objective: Intralaminar screws have been shown to be a biomechanical salvage technique in the thoracic spine, especially in long cervicothoracic, thoracic and thoracolumbar fixation. The goals of this article are to demonstrate our initial experience and the range of indications for thoracic crossed intralaminar screws. Methods: In this article we describe our initial series performed at S&#227o Teot&#243nio Hospital in Viseu, Portugal, and our results, and also provide a comprehensive review of the recent literature in the use of intralaminar crossed fixation. 展开更多
关键词 Crossed Intralaminar Spinolaminar Angle THORACIC Imaging Lamina screws Spinal Fusion/Instrumentation/Methods Thoracic Vertebrae
下载PDF
Fixation of Calcaneal Tuberosity Beavis II Fracture in Elderly Patients Using Locking Plate Combined with Tension Screw
15
作者 De-Jian Li Jia-Wen He +2 位作者 Jian-Hua Zhou Cheng-Qing Yi Qi-Kai Huang 《Biomedical Engineering Communications》 2023年第1期24-28,共5页
Background:Calcaneus is the largest bone of foot and the main load-bearing structure of heel.The incidence of simple calcaneal tubercle avulsion fracture is low,accounting for about 1%to 3%of all calcaneal fractures.B... Background:Calcaneus is the largest bone of foot and the main load-bearing structure of heel.The incidence of simple calcaneal tubercle avulsion fracture is low,accounting for about 1%to 3%of all calcaneal fractures.Beavis II fracture has large bone fracture,obvious displacement,obvious soft tissue irritation,and often leads to skin necrosis.It needs surgical treatment,reduction and fixation as soon as possible.Although open reduction and tension screw internal fixation is used for Beavis II calcaneal tubercle fracture,but the failure rate is more common.Methods:This study retrospectively analyzed the surgical treatment of calcaneal tubercle Beavis II fracture over 55 years old in our hospital from January 2013 to January 2019.The patients were treated with tension screw combined with locking plate,and followed up and analyzed.Results:12 patients in this group were followed up for 12 to 36 months(mean 20 months).After operation,the fracture healed smoothly in all patients,the healing time was 8 to 12 weeks(mean 10.7 weeks),and there were no complications such as poor incision healing,fracture displacement,internal fixation loosening,fracture and so on.When the patients were followed up 18 weeks after operation,the AOFAS score was 47 to 100,with an average of 91.1,of which 8 cases were excellent,3 good and 1 poor,with an excellent and good rate of 91.7%.Conclusion:Our hospital has been treated with tension screw combined with locking plate,fixed firmly,can early functional exercise,achieved good results. 展开更多
关键词 calcaneal tubercle Beavis II fracture locking plate tension screw elderly patients
下载PDF
Development of Technology and Equipment for Non-destructive Testing of Defects in Sewing Mandrels of a Three-roll Screw Mill 30-80
16
作者 Shatalov Roman Lvovich Zagoskin Egor Evgenievich 《Journal of Electronic & Information Systems》 2023年第2期61-66,共6页
The conditions of heating and cooling of piercing mandrels made of 4X5MFS steel of a three-roll screw mill 30-80 in the production of a closed cavity of steel vessels of small volume are determined.It is established t... The conditions of heating and cooling of piercing mandrels made of 4X5MFS steel of a three-roll screw mill 30-80 in the production of a closed cavity of steel vessels of small volume are determined.It is established that multiple cycles of heating up to 600℃ and cooling with water up to 80℃ for about 7 seconds/1 cycle lead to the formation of ridges,shells and cracks on the surface and in the volume of the tool.The loss of structural strength of the material leads to the breakdown of the mandrel during the stitching process.The technique and equipment of magnetic powder control have been developed to establish the dynamics of the growth of internal and external defects of mandrels.An equation is obtained that allows determining the increase in the number of defects in the sewing tool of a screw rolling mill.The technology of non-destructive testing made it possible to develop a rational plan for replacing the sewing mandrels,which allows for predicting the appearance of defects leading to a complex breakdown of the deforming tool at the NPO Pribor machine-building enterprise. 展开更多
关键词 screw rolling mill 30-80 Piercing mandrel made of 4X5MFS steel Vessel made of 50 steel Temperature Crack Magnetic powder control of hidden defects
下载PDF
Type Synthesis of Self-Alignment Parallel Ankle Rehabilitation Robot with Suitable Passive Degrees of Freedom
17
作者 Ya Liu Wenjuan Lu +3 位作者 Dabao Fan Weijian Tan Bo Hu Daxing Zeng 《Chinese Journal of Mechanical Engineering》 SCIE EI CAS CSCD 2024年第1期160-175,共16页
The current parallel ankle rehabilitation robot(ARR)suffers from the problem of difficult real-time alignment of the human-robot joint center of rotation,which may lead to secondary injuries to the patient.This study ... The current parallel ankle rehabilitation robot(ARR)suffers from the problem of difficult real-time alignment of the human-robot joint center of rotation,which may lead to secondary injuries to the patient.This study investigates type synthesis of a parallel self-alignment ankle rehabilitation robot(PSAARR)based on the kinematic characteristics of ankle joint rotation center drift from the perspective of introducing"suitable passive degrees of freedom(DOF)"with a suitable number and form.First,the self-alignment principle of parallel ARR was proposed by deriving conditions for transforming a human-robot closed chain(HRCC)formed by an ARR and human body into a kinematic suitable constrained system and introducing conditions of"decoupled"and"less limb".Second,the relationship between the self-alignment principle and actuation wrenches(twists)of PSAARR was analyzed with the velocity Jacobian matrix as a"bridge".Subsequently,the type synthesis conditions of PSAARR were proposed.Third,a PSAARR synthesis method was proposed based on the screw theory and type of PSAARR synthesis conducted.Finally,an HRCC kinematic model was established to verify the self-alignment capability of the PSAARR.In this study,93 types of PSAARR limb structures were synthesized and the self-alignment capability of a human-robot joint axis was verified through kinematic analysis,which provides a theoretical basis for the design of such an ARR. 展开更多
关键词 Ankle rehabilitation robot SELF-ALIGNMENT Parallel mechanism Type synthesis screw theory
下载PDF
Peri-articular elbow fracture fixations with magnesium implants and a review of current literature: A case series
18
作者 Christopher Fang Antony Xavier Rex Premchand +1 位作者 Derek Howard Park Dong Hao Toon 《World Journal of Orthopedics》 2024年第3期215-229,共15页
BACKGROUND In recent years,the use of Magnesium alloy implants have gained renewed popularity,especially after the first commercially available ConformitéEuropéenne approved Magnesium implant became availabl... BACKGROUND In recent years,the use of Magnesium alloy implants have gained renewed popularity,especially after the first commercially available ConformitéEuropéenne approved Magnesium implant became available(MAGNEZIX®CS,Syntellix)in 2013.AIM To document our clinical and radiographical outcomes using magnesium implants in treating peri-articular elbow fractures.METHODS Our paper was based on a retrospective case series design.Intra-operatively,a standardized surgical technique was utilized for insertion of the magnesium implants.Post–operatively,clinic visits were standardized and physical exam findings,functional scores,and radiographs were obtained at each visit.All complications were recorded.RESULTS Five patients with 6 fractures were recruited(2 coronoid,3 radial head and 1 capitellum).The mean patient age and length of follow up was 54.6 years and 11 months respectively.All fractures healed,and none exhibited loss of reduction or complications requiring revision surgery.No patient developed synovitis of the elbow joint or suffered electrolytic reactions when titanium implants were used concurrently.CONCLUSION Although there is still a paucity of literature available on the subject and further studies are required,magnesium implants appear to be a feasible tool for fixation of peri-articular elbow fractures with promising results in our series.INTRODUCTION In recent years,the use of Magnesium alloy implants in orthopaedic surgeries have gained renewed popularity.Apart from being bioabsorbable,negating the need for implant removal,magnesium also has good osteoconductive properties[1-4].Biomechanically,it exhibits greater biomechanical strength than any pre-existing polymers,and reduces the stress-shielding effect associated with titanium and steel implants as it has a Young’s modulus closer to bone[4].Currently,the main utility of magnesium implants in the orthopaedic community is within the foot and ankle community where satisfactory results have been reported with its utility in forefoot osteotomies[5-7].However,its utility in the setting of orthopaedic trauma has been steadily increasing[8].Our study aims to document our clinical and radiographical outcomes using magnesium implants to treat peri-articular elbow fractures.To our knowledge,our study is the first study analyzing outcomes in radial head and coronoid fractures in the English literature. 展开更多
关键词 Magnesium screw Fracture Peri-articular ELBOW
下载PDF
Effective time, correction speed and termination time of hemiepiphysiodesis in children
19
作者 Jian-Fa Zeng Yu-Yin Xie +5 位作者 Can Liu Zhen-Qi Song Zheng Xu Zhong-Wen Tang Jie Wen Sheng Xiao 《World Journal of Orthopedics》 2024年第1期1-10,共10页
In children with asymmetric growth on the medial and lateral side of limbs,if there still remains growth potential,the guided growth technique of hemiepiphysiodesis on one side of the epiphysis is recognized as a safe... In children with asymmetric growth on the medial and lateral side of limbs,if there still remains growth potential,the guided growth technique of hemiepiphysiodesis on one side of the epiphysis is recognized as a safe and effective method.However,when the hemi-epiphysiodesis start to correct the deformities,how many degrees could hemi-epiphysiodesis bring every month and when to remove the hemi-epiphysiodesis implant without rebound phenomenon are still on debate.This article reviews the current studies focus on the effective time,correction speed and termination time of hemi-epiphysiodesis. 展开更多
关键词 Hemi-epiphysiodesis Percutaneous epiphysiodesis Transphyseal screws Eight plate
下载PDF
C1C2 Wiring and Posttraumatic Atlantoaxial Dislocation: An Effective and Cheap Surgical Procedure in a Developing Country
20
作者 Ibrahim Dao Massimiliano Visocchi +11 位作者 Salah Sow John Jabang Ousmane Ouattara Astride Somda Abdoulaye Sanou Elie Dibloni Nassoum Arsène Tossou Narcisse Ouedraogo Frédéric Bako Massadiami Soulama Malick Diallo Patrick Wendpouiré Hamed Dakouré 《Surgical Science》 2024年第5期357-370,共14页
Objectives: Atlantoaxial dislocation remains a rare and serious condition with a high preoperative and postoperative morbidity and mortality. Its successful surgical management is still challenging and gratifying for ... Objectives: Atlantoaxial dislocation remains a rare and serious condition with a high preoperative and postoperative morbidity and mortality. Its successful surgical management is still challenging and gratifying for neurosurgeons. Several technics have been described such as wiring, trans articular screwing, C1C2 screwing with plate and screw introduced by Goel et al., and modified by insertion of polyaxially screw and rod many years later by Harms. Unavailability and expensiveness of upper cervical spine instrumentation device led us to C1C2 Wiring resulting in a good outcome. Finally, a quadriplegic patient with a more comfortable financial condition had ordered devices from abroad and benefit for Goel and Harms screwing technique and improved dramatically from ASIA A to ASIA E. Material and methods: This is a retrospective study of patients managed in our department by a same neurosurgeon from January 2019 to April 2024. Results: We defined 6 men and 1 woman with an average age of 33 years. Unrestrained driver in a rollover motor vehicle accident was most common. Only one patient was neurologically intact on admission. Neurovegetative disorders were noticed in one patient. Dislocation was associated to a fracture of the dens in two patients. Three patients have been successfully operated with remarkable outcome, mostly from ASIA A to E. Conclusion: C1C2 dislocation is a serious condition and C1C2 Wiring represents an effective and cheaper technic. Therefore, this technic should deserve consideration above all in low incomes countries when screwing devices are not available. Seatbelt should be demanded for motor vehicle drivers and passengers. 展开更多
关键词 Superior Cervical Spine DISLOCATION Fracture WIRING screwing Neurovegetative Disorders
下载PDF
上一页 1 2 19 下一页 到第
使用帮助 返回顶部