Four levels of the data from the search coil magnetometer(SCM) onboard the China Seismo-Electromagnetic Satellite(CSES)are defined and described. The data in different levels all contain three components of the wavefo...Four levels of the data from the search coil magnetometer(SCM) onboard the China Seismo-Electromagnetic Satellite(CSES)are defined and described. The data in different levels all contain three components of the waveform and/or spectrum of the induced magnetic field around the orbit in the frequency range of 10 Hz to 20 kHz; these are divided into an ultra-low-frequency band(ULF,10–200 Hz), an extremely low frequency band(ELF, 200–2200 Hz), and a very low frequency band(VLF, 1.8–20 kHz). Examples of data products for Level-2, Level-3, and Level-4 are presented. The initial results obtained in the commission test phase demonstrated that the SCM was in a normal operational status and that the data are of high enough quality to reliably capture most space weather events related to low-frequency geomagnetic disturbances.展开更多
The seismic activities on the Earth can produce a disturbance of the electromagnetic field and particles in the ionosphere. The search coil magnetometer(SCM) mounted on China Seismo-Electromagnetic satellite(CSES) is ...The seismic activities on the Earth can produce a disturbance of the electromagnetic field and particles in the ionosphere. The search coil magnetometer(SCM) mounted on China Seismo-Electromagnetic satellite(CSES) is designed to measure the magnetic field fluctuation of low frequency electromagnetic waves in the frequency range of 10 Hz–20 k Hz. The SCM comprises a three-axis search coil sensor mounted on a 4.5 m boom and an electronic box inside satellite module. The sampling rate of the SCM is 51.2 k Hz and the time resolution of the power spectrum density(PSD) is 2 s. The frequency resolution is 12.5 Hz.There are three operation modes: survey, detailed survey and calibration. In the survey mode, the SCM can provide a PSD in the whole frequency range of 10 Hz–20 k Hz and wave forms in the low frequency range below 2 k Hz while in the detailed survey mode the SCM can provide both PSD and wave forms in the whole frequency range of 10 Hz–20 k Hz. The sensitivity of the SCM instrument is 5.0×10^(-4) n T Hz^(-1/2) at 10 Hz, 5.0×10^(–5) n T Hz^(-1/2) at 200 Hz, 3.4×10^(-5) n T Hz^(-1/2) at 2 k Hz and 1.1×10^(-4) n T Hz^(-1/2) at 20 k Hz. The telemetry rate is ~0.85 Mbps in the survey mode and ~3.0 Mbps in the detailed survey mode. The phase difference between three axes can be made generally with a precision of less than 1.0°. The dynamic range of the SCM instrument is over 100 d B. The orthogonality of three mechanical axes of search coil senor is better than 0.13°. The performance of SCM can satisfy the requirement of scientific objectives of CSES mission.展开更多
基金supported by the State Key R&D Project (Grant No. 2016YFE0122200)the Civil Aerospace Scientific Research Project “Data calibration and validation for CSES, ”the Central-Level Public Welfare Research Projects of the Institute of Crustal Dynamics Institute, China Earthquake Administration (Grant No. ZDJ2017-21)
文摘Four levels of the data from the search coil magnetometer(SCM) onboard the China Seismo-Electromagnetic Satellite(CSES)are defined and described. The data in different levels all contain three components of the waveform and/or spectrum of the induced magnetic field around the orbit in the frequency range of 10 Hz to 20 kHz; these are divided into an ultra-low-frequency band(ULF,10–200 Hz), an extremely low frequency band(ELF, 200–2200 Hz), and a very low frequency band(VLF, 1.8–20 kHz). Examples of data products for Level-2, Level-3, and Level-4 are presented. The initial results obtained in the commission test phase demonstrated that the SCM was in a normal operational status and that the data are of high enough quality to reliably capture most space weather events related to low-frequency geomagnetic disturbances.
基金supported by the National Natural Science Foundation of China(Grant No.41431071)
文摘The seismic activities on the Earth can produce a disturbance of the electromagnetic field and particles in the ionosphere. The search coil magnetometer(SCM) mounted on China Seismo-Electromagnetic satellite(CSES) is designed to measure the magnetic field fluctuation of low frequency electromagnetic waves in the frequency range of 10 Hz–20 k Hz. The SCM comprises a three-axis search coil sensor mounted on a 4.5 m boom and an electronic box inside satellite module. The sampling rate of the SCM is 51.2 k Hz and the time resolution of the power spectrum density(PSD) is 2 s. The frequency resolution is 12.5 Hz.There are three operation modes: survey, detailed survey and calibration. In the survey mode, the SCM can provide a PSD in the whole frequency range of 10 Hz–20 k Hz and wave forms in the low frequency range below 2 k Hz while in the detailed survey mode the SCM can provide both PSD and wave forms in the whole frequency range of 10 Hz–20 k Hz. The sensitivity of the SCM instrument is 5.0×10^(-4) n T Hz^(-1/2) at 10 Hz, 5.0×10^(–5) n T Hz^(-1/2) at 200 Hz, 3.4×10^(-5) n T Hz^(-1/2) at 2 k Hz and 1.1×10^(-4) n T Hz^(-1/2) at 20 k Hz. The telemetry rate is ~0.85 Mbps in the survey mode and ~3.0 Mbps in the detailed survey mode. The phase difference between three axes can be made generally with a precision of less than 1.0°. The dynamic range of the SCM instrument is over 100 d B. The orthogonality of three mechanical axes of search coil senor is better than 0.13°. The performance of SCM can satisfy the requirement of scientific objectives of CSES mission.
基金supported by the Natural Science Foundation of Liaoning Province(2019-ZD-0039)the Basic Scientific Research Project of Liaoning Education Department(LJ2020JCL003).