There is a global trend for seismic response improvement of new buildings to reduce cost and future damage. It is also important to improve existing structures that are designed without consideration of seismic load o...There is a global trend for seismic response improvement of new buildings to reduce cost and future damage. It is also important to improve existing structures that are designed without consideration of seismic load or using old provisions that cannot meet the new one. The objective of this paper is to draw attention to evaluate existing reinforced concrete school buildings, then to present a proposed methodology to improve the behaviour of such schools with low cost especially in a developing country. The proposed method uses overhead water tanks as a tuned mass damper. A pushover analysis has been performed to evaluate the existing schools and perform a feasibility study to select the best solution to achieve seismic response improvement of the existing structure. Of course, the proposed methodology can be applied easily to other existing structures.展开更多
The information of seismic response spectra is key to many problems concerned with aseismic structure and is also helpful for earthquake disaster relief if it is generated in time when earthquake happens. While curren...The information of seismic response spectra is key to many problems concerned with aseismic structure and is also helpful for earthquake disaster relief if it is generated in time when earthquake happens. While current numerical calculation methods suffer from poor precision, especially in frequency band near Nyquist frequency, we present a set of improved parameters for precision improvement. It is shown that precision of displacement and velocity response spectra are both further improved compared to current numerical algorithms. A uniform fitting formula is given for computing these parameters for damping ratio range of 0.01-0.9, quite convenient for practical application.展开更多
文摘There is a global trend for seismic response improvement of new buildings to reduce cost and future damage. It is also important to improve existing structures that are designed without consideration of seismic load or using old provisions that cannot meet the new one. The objective of this paper is to draw attention to evaluate existing reinforced concrete school buildings, then to present a proposed methodology to improve the behaviour of such schools with low cost especially in a developing country. The proposed method uses overhead water tanks as a tuned mass damper. A pushover analysis has been performed to evaluate the existing schools and perform a feasibility study to select the best solution to achieve seismic response improvement of the existing structure. Of course, the proposed methodology can be applied easily to other existing structures.
基金supported by Science for Earthquake Resilience (XH12032)
文摘The information of seismic response spectra is key to many problems concerned with aseismic structure and is also helpful for earthquake disaster relief if it is generated in time when earthquake happens. While current numerical calculation methods suffer from poor precision, especially in frequency band near Nyquist frequency, we present a set of improved parameters for precision improvement. It is shown that precision of displacement and velocity response spectra are both further improved compared to current numerical algorithms. A uniform fitting formula is given for computing these parameters for damping ratio range of 0.01-0.9, quite convenient for practical application.