期刊文献+
共找到110,832篇文章
< 1 2 250 >
每页显示 20 50 100
Contrast Detection Learning Improves Visual Contrast Sensitivity of Cat 被引量:6
1
作者 华田苗 王振华 +1 位作者 徐金旺 刁建刚 《Zoological Research》 CAS CSCD 北大核心 2010年第2期155-162,共8页
Psychological studies on human subjects show that contrast detection learning promote learner's sensitivity to visual stimulus contrast. The underlying neural mechanisms remain unknown. In this study, three cats (Fe... Psychological studies on human subjects show that contrast detection learning promote learner's sensitivity to visual stimulus contrast. The underlying neural mechanisms remain unknown. In this study, three cats (Felis catus) were trained to perform monocularly a contrast detection task by two-altemative forced choice method. The perceptual ability of each cat improved remarkably with learning as indicated by a significantly increased contrast sensitivity to visual stimuli. The learning effect displayed an evident specificity to the eye employed for learning but could partially transfer to the naive eye, prompting the possibility that contrast detection learning might cause neural plasticity before and after the information from both eyes are merged in the visual pathway. Further, the contrast sensitivity improvement was evident basically around the spatial frequency (SF) used for learning, which suggested that contrast detection learning effect showed, to some extent, a SF specificity. This study indicates that cat exhibits a property of contrast detection learning similar to human subjects and can be used as an animal model for subsequent investigations on the neural correlates that mediate learning-induced contrast sensitivity improvement in humans. 展开更多
关键词 VISUAL contrast detection LEARNING contrast sensitivity CAT
下载PDF
Decreased contrast sensitivity of visual cortical cells to visual stimuli accompanies a reduction of intracortical inhibition in old cats 被引量:2
2
作者 周俊 施夏明 +2 位作者 彭青松 化国鹏 华田苗 《Zoological Research》 CAS CSCD 北大核心 2011年第5期533-539,共7页
Psychophysical experiments on human and animal subjects have proven that aged individuals show significantly reduced visual contrast sensitivity compared with young adults.To uncover the possible neural mechanisms,we ... Psychophysical experiments on human and animal subjects have proven that aged individuals show significantly reduced visual contrast sensitivity compared with young adults.To uncover the possible neural mechanisms,we used extracellular single-unit recording techniques to examine the response of V1(primary visual cortex) neurons as a function of visual stimulus contrast in both old and young adult cats(Felis catus).The mean contrast sensitivity of V1 neurons to visual stimuli in old cats decreased significantly relative to young adult cats,consistent with findings reported in old primates.These results indicate that aging can affect contrast sensitivity of visual cortical cells in both primate and non-primate mammalian animals,and might contribute to the reduction of perceptual visual contrast sensitivity in aged individuals.Further,V1 cells of old cats exhibited increased responsiveness,decreased signal-to-noise ratio,and enlarged receptive field(RF) size compared with that of young adult cats,which indicated that decreased contrast sensitivity of V1 neurons accompanied a reduction of intracortical inhibition during senescence. 展开更多
关键词 contrast sensitivity V1 neurons Old cats Young adult cats
下载PDF
Effects of higher-order aberrations on contrast sensitivity in normal eyes of a large myopic population 被引量:11
3
作者 Peng-Fei Zhao Shi-Ming Li +4 位作者 Jing Lu Hong-Min Song Jing Zhang Yue-Hua Zhou Ning-Li Wang 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2017年第9期1407-1411,共5页
AIM:To study the relation between higher-order aberrations(HOAs)and contrast sensitivity(CS)in normal eyes among a population of laser in situ keratomileusis(LASIK)candidates.METHODS:In 6629 eyes of 3315 LASIK... AIM:To study the relation between higher-order aberrations(HOAs)and contrast sensitivity(CS)in normal eyes among a population of laser in situ keratomileusis(LASIK)candidates.METHODS:In 6629 eyes of 3315 LASIK candidates,CS were measured under dark environment at the spatial frequencies of 1.5,3,6,12 and 18 cycles per degree(c/d),respectively,using an Optec 6500 visual function tester.Meanwhile,ocular HOAs were measured for a 6.0 mm pupil with a Hartmann-Shack wavefront analyzer.RESULTS:In the study,the subjects with an average spherical equivalent of-4.86±2.07 D were included.HOAs decreased from the third to the sixth order aberrations with predominant aberrations of third-order coma,trefoil and fourth-order spherical aberration.At low and moderate spatial frequencies,CS was negatively correlated with the third-order coma and trefoil aberrations,and decreased with increasing Z31,but increased with increasing Z3-3and Z5-1.At high spatial frequencies,CS decreased with increasing Z3-3and increased with increasing Z5-1.CONCLUSION:At a large pupil size of 6.0 mm,the thirdorder aberrations,but not the total aberrations,are the main factors affecting CS.Vertical coma is negatively correlated with CS. 展开更多
关键词 MYOPIA contrast sensitivity higher-orderaberrations COMA spherical aberration
下载PDF
Contrast sensitivity in 14 MeV fast neutron radiography 被引量:5
4
作者 Chang-Bing Lu Jie Bao +4 位作者 Ying Huang Peng Xu Xiong-Jun Chen Qi-Wei Zhang Xi-Chao Ruan 《Nuclear Science and Techniques》 SCIE CAS CSCD 2017年第6期115-122,共8页
Fast neutron radiography(FNR) is an effective non-destructive testing technique.Due to the scattering effect and low detection efficiency,the detection limit of FNR under certain conditions cannot be determined.In ord... Fast neutron radiography(FNR) is an effective non-destructive testing technique.Due to the scattering effect and low detection efficiency,the detection limit of FNR under certain conditions cannot be determined.In order to obtain the minimum detectable thickness by FNR,we studied the contrast sensitivity of FNR lead samples,both theoretically and experimentally.We then clarified the relationship between pixel value and irradiation time,and sample materials and thickness.Our experiment,using a4-cm-thick lead sample,verified our theoretical expression of FNR contrast sensitivity. 展开更多
关键词 FAST NEUTRON RADIOGRAPHY contrast sensitivity EXPERIMENTAL research
下载PDF
Relationship between contrast sensitivity and corneal shape following overnight orthokeratology 被引量:6
5
作者 Li-Li Liu Li-Ping Gong +3 位作者 Yue-Yuan Xu Xuan Zhu Kaddie Kwok Chen Wei-Feng Liu 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2019年第2期275-279,共5页
AIM: To evaluate the relationship between contrast sensitivity(CS) and corneal shape following overnight orthokeratology(OK). METHODS: We conducted a retrospective clinical study of 80 lens-wearing myopia patients, al... AIM: To evaluate the relationship between contrast sensitivity(CS) and corneal shape following overnight orthokeratology(OK). METHODS: We conducted a retrospective clinical study of 80 lens-wearing myopia patients, all of whom had undergone OK and had been evaluated by Orbscan II topography. We measured the surface irregularity index(SIRI) of corneal topography at 3 and 5 mm, the size of the flattened central corneal curvature of OK lens(zone A), the size of the cornea altered by OK lens(zone B), the size of the pupillary area at the corneal level(zone C), the area of crossover between zones A and C(zone AC), the area of crossover between zones B and C(BC), the ratio of BC to B(BC/B), and the ratio of AC to C(AC/C). CS was evaluated using the CSV-1000 with spatial frequencies of 3, 6, 12, and 18 cycles/degree(CPD). RESULTS: Multiple correlation analyses indicated significant negative correlations between CS, zone C, BC/B, and 3-mm SIRI(all P<0.01). There were no significant differences between CS, zone B, AC/A, or 5-mm SIRI(P=0.60, 0.94 and 0.11, respectively). Zone C was negatively correlated with 3, 6, 12, and 18 CPD. 5-mm SIRI were negatively correlated with 6, 12, and 18 CPD. BC/C was negatively correlated with 6 and 18 CPD. AC/C was positively correlated with 3 CPD. CONCLUSION: Zone C, 3-mm SIRI and BC/B affect the CS following overnight OK. 展开更多
关键词 ORTHOKERATOLOGY contrast sensitivity PUPIL size area shaped CORNEA MYOPIA
下载PDF
Comparison of contrast sensitivity and visual acuity between deep anterior lamellar keratoplasty and penetrating keratoplasty in patients with keratoconus 被引量:3
6
作者 Mehmet Orcun Akdemir Baran Kandemir +2 位作者 Isil Bahar Sayman Cem Selvi OmerKamil Dogan 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2012年第6期737-741,共5页
AIM: To evaluate postoperative visual acuity and contrast sensitivity results following deep anterior lamellar keratoplasty (DALK) and penetrating keratoplasty (PK) in patients with keratoconus (KC). METHODS: All the ... AIM: To evaluate postoperative visual acuity and contrast sensitivity results following deep anterior lamellar keratoplasty (DALK) and penetrating keratoplasty (PK) in patients with keratoconus (KC). METHODS: All the patients’ records with KC who had PK or DALK surgery between May 2010 and May 2011 were retrospectively reviewed. Sixty patients who underwent successful corneal transplantation for KC: 30 eyes underwent DALK and 30 eyes underwent PK were included in this study. Preoperative and postoperative mean logarithm of the minimum angle of resolution (logMAR) uncorrected visual acuity (UCVA), logMAR best spectacle-corrected visual acuity (BSCVA) and intraocular pressure (IOP) were evaluated. Contrast sensitivity tests (CS) were done preoperative and 2 months after all sutures had removed. All surgeries were performed under regional anesthesia (retrobulbar anesthesia) by 1 surgeon (B.K.) who was experienced in penetrating and lamellar keratoplasty techniques. RESULTS: The mean age of the DALK group was 29.67±4.95 (range 18-40) years and the PK group was 28.7±3.53 (range 18-39) years. Preoperatively there was no significant difference in the logMAR UCVA, logMAR BSCVA and IOP between the DALK (1.281±0.56; 0.97±0.85; 12.07±2.12mmHg) and PK (1.34±0.21; 0.98±0.21; 13±2.12mmHg) groups. One-year after surgery there was no significant difference in the mean logMAR UCVA and IOP between the DALK (0.46±0.37; 11.73±2.1mmHg) and PK (0.38±0.21; 12±2.12mmHg) groups. The mean contrast sensitivity was evaluated by CC-100 Topcon LCD at 1.5, 2.52, 4.23, 7.10 and 11.91 cycles per degree (cs/deg) spatial frequencies before and 2 months after the all sutures had removed. CONCLUSION: All patients with keratoconus in both DALK and PK groups performed good visual function postoperatively. The mean contrast sensitivity increased considerably at all spatial frequencies compared with preoperative levels in the DALK and PK groups. The mean post-operative evaluation of contrast sensitivity measurements was not significantly different between the two groups. 展开更多
关键词 contrast sensitivity KERATOCONUS corneal transplantation
下载PDF
Assessment of contrast sensitivity loss after intrastromal femtosecond laser and LASIK procedure 被引量:2
7
作者 Elsa L.C.Mai Ie-Bin Lian David C.K.Chang 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2016年第12期1798-1801,共4页
AIM: To assess the loss of contrast sensitivity (CS) function for INTRACOR or intrastromal femtosecond laser presbyopia procedure to conventional LASIK procedures.METHODS: Patients were recruited from a refractive... AIM: To assess the loss of contrast sensitivity (CS) function for INTRACOR or intrastromal femtosecond laser presbyopia procedure to conventional LASIK procedures.METHODS: Patients were recruited from a refractive surgery center for either INTRACOR or conventional LASIK. INTRACOR was performed on 8 eyes and LASIK was performed for 40 eyes in an overlapping period. Pre-operative evaluation and post-operative follow up for up to three months was done. Drops of CS in 4 spatial frequency (3 cpd, 6 cpd, 12 cpd and 18 cpd) right before and 3mo after the surgery were compared by Wilcoxon signed ranks test.RESULTS: For INTRACOR, CS threshold showed significant drop at both glare and non-glare condition, the drop was seen in all 4 spatial frequency. The averaged loss over the 4 spatial frequencies 3mo after surgery was 1.18 for non-glare and 0.71 for glare. For LASIK the CS threshold drop was most significant in 12 cpd for glare.CONCLUSION: INTRACOR procedure produces a gain of near vision for presbyopia patients but also introduces a high lost of contrast sensitivity plus worsen of vision quality. Pre-surgical patient selection and advise should be given with specific regards to night driving and glare conditions. 展开更多
关键词 INTRACOR LASIK contrast sensitivity intrastromal femtosecond laser
下载PDF
Comparison of contrast sensitivity based on the surgical results for intermittent exotropia
8
作者 Hae Rang Kim Soo Jung Lee 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2019年第11期1725-1730,共6页
AIM: To compare contrast sensitivity(CS) based on the surgical results for intermittent exotropia(IXT) and to examine the relationship between CS and photophobia.METHODS: Medical records of the patients who underwent ... AIM: To compare contrast sensitivity(CS) based on the surgical results for intermittent exotropia(IXT) and to examine the relationship between CS and photophobia.METHODS: Medical records of the patients who underwent bilateral lateral rectus muscle recession for IXT between 4 and 12 years old were reviewed retrospectively. They were categorized based on the surgical results;successful correction group(n=36) and overcorrection group(esotropia ≥10 PD at 3 mo postoperatively, n=18). Using CGT-2000 test for CS was performed binocularly, and subjective reports of photophobia was investigated preoperatively and at 3 mo postoperatively. Objective photophobia was defined as a significant decrease in CS in the presence of glare.RESULTS: Preoperatively, there was no difference in CS between the groups. Postoperatively, under mesopic conditions, significant improvement of CS was observed at 6.3°, 4°, and 2.5° in the successful correction group and at 6.3° and 4° in the overcorrection group, regardless of glare. Under photopic conditions, at all visual angles except 0.64°, improvement in CS was noted in both groups while CS worsened significantly at 0.64° in the overcorrection group postoperatively. At all visual angles under photopic conditions postoperatively, regardless of glare, CS in the overcorrected group was significantly worse than that in the successful correction group, and CS was significantly decreased by addition of glare in both groups. All patients except one(96.4%) in the successful correction group and 8 patients(61.5%) in overcorrection group showed improvement of photophobia postoperatively, which correlated with CS under photopic conditions(P=0.001, 0.03).CONCLUSION: After surgery for IXT, CS under photopic conditions improve at all visual angles except 0.64°, while CS is significantly worse in the overcorrection group postoperatively at 0.64°. Subjective photophobia havesignificant correlation with CS under photopic conditions, and may be used as an objective indicator of photophobia. 展开更多
关键词 contrast sensitivity INTERMITTENT EXOTROPIA OVERCORRECTION PHOTOPHOBIA SUCCESS
下载PDF
Age norms for grating acuity and contrast sensitivity measured by Lea tests in the first three years of life
9
作者 Amal A.Elgohary Manal H.Abuelela Adel Alei Eldin 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2017年第7期1150-1153,共4页
AIM: To determine age norms in the first three years of life for grating visual acuity and contrast sensitivity obtained with Lea grating test and Hiding Heidi low contrast face test. METHODS: Lea grating test was u... AIM: To determine age norms in the first three years of life for grating visual acuity and contrast sensitivity obtained with Lea grating test and Hiding Heidi low contrast face test. METHODS: Lea grating test was used to estimate binocular grating acuity and Hiding Heidi low contrast face test was used to estimate contrast sensitivity in 600 healthy infants and children. Age ranged from 3 to 36 mo subdivided into 12 groups subjected for full ophthalmologic and pediatric examinations.RESULTS: The grating acuity developed along the first three years of life. It ranged from 1.88±0.32 c/d at 3mo to 30.95±0.77 c/d at 36 mo. The most rapid development was during the first 12 mo and the slowest development was from 30 to 36 mo. The contrast sensitivity showed rapid development in the first two years of life. Its mean value ranged from 4.23±1.17 at 3mo to 78.26±8.21 at 24 mo. It was constant at the highest score(80) thereafter.CONCLUSION: Age norms for grating acuity along with contrast sensitivity offer a more comprehensive measure of spatial vision and should be incorporated in clinical practice for better visual assessment in preverbal and nonverbal children. 展开更多
关键词 grating acuity contrast sensitivity age norms Lea tests preverbal children
下载PDF
CONTRAST SENSITIVITY IN AMBLYOPIA
10
作者 Shaomei Yang De-zheng Wu Ning Tian Lezheng Wu Zhongshan Ophthalmic Centre Sun Yat-sen University of Medical Sciences Guangzhou, China 《眼科学报》 1991年第1期25-28,共4页
Contrast sensitivity function(CSF) for sinusoid gratings of varying spatial frequencies was determined for each eye of 21 cases with unilateral amblyopia. The CSF of all amblyopic eyes, except one, showed reduced sens... Contrast sensitivity function(CSF) for sinusoid gratings of varying spatial frequencies was determined for each eye of 21 cases with unilateral amblyopia. The CSF of all amblyopic eyes, except one, showed reduced sensitivity when compared with the non-amblyopic eye of the same person. The curve showed reduction more significantly at middle and high spatial frequencies. The cut-off frequency was shifted toward lower spatial frequencies. The relationship between CSF and various degree of amblyopia was als... 展开更多
关键词 CSF contrast sensitivity IN AMBLYOPIA
下载PDF
AB037.Preliminary findings from the COMPASS-ND study:reading acuity and contrast sensitivity at different levels of cognitive impairment
11
作者 Faisal Al-Yawer Natalie Phillips Walter Wittich 《Annals of Eye Science》 2019年第1期212-212,共1页
Background:Declines in visual function have been reported in individuals with Alzheimer’s disease(AD)and other neurological disorders,and have been associated with cognitive decline seen in those disorders.Here we re... Background:Declines in visual function have been reported in individuals with Alzheimer’s disease(AD)and other neurological disorders,and have been associated with cognitive decline seen in those disorders.Here we report preliminary visual findings from the COMPASS-ND study of the Canadian Consortium on Neurodegeneration in Aging(CCNA)in a diverse group of individuals at various stages of cognitive impairment,diagnosed via clinical consensus and stringent criteria.Methods:Participants were 109 older adults(age range,60-89,M=72.94,SD=7.01)that are part of the CCNA cohort at different stages of cognitive decline(subjective cognitive impairment,SCI,n=24;mild cognitive impairment,MCI,n=64;mild AD,n=21).Reading acuity(MNRead)and contrast sensitivity(Mars test)were tested with habitual correction.We additionally report scores on the Montreal Cognitive Assessment(MoCA)scale for the three groups.Results:Out of all the participants,25%had reduced reading acuity[>0.5 logMAR(20/63)]and 23%presented with moderate to severe loss of contrast sensitivity[<1.48 log CS(3.3%contrast)].Only 6.5%of participants had combined reduced reading acuity and moderate to severe contrast sensitivity.Notably,only 8.3%of individuals with SCI presented with reduced reading acuity,compared to 32.3%and 23.8%of those with MCI and AD,respectively(χ2=5.28,P=0.071).Lower contrast sensitivity was observed in AD participants relative to those with MCI and SCI(P=0.04,ω2=0.04;Figure 1),after adjusting for age,sex and education.No differences in reading acuity were observed(P=0.46,ω2=0.004).Conclusions:Using the Mars test,a measure of the processing of low spatial frequencies,we were able to replicate previous reports of declines in contrast sensitivity in individuals with AD compared to those with MCI and SCI.We also observed higher rates of reduced reading acuity in the AD and MCI groups relative to those reported in the general population.These results set the groundwork for examining the relationship between vision status and cognitive function,brain integrity,quality of life,in these groups. 展开更多
关键词 Cognitive impairment COGNITION visual acuity contrast sensitivity
下载PDF
Psychophysics in the ophthalmological practice—Ⅱ.Contrast sensitivity
12
作者 Claudio Rosa Carlo Aleci 《Annals of Eye Science》 2022年第4期27-39,共13页
Contrast is the differential luminance between one object and another.Contrast sensitivity(CS)quantifies the ability to detect this difference:estimating contrast threshold provides information about the quality of vi... Contrast is the differential luminance between one object and another.Contrast sensitivity(CS)quantifies the ability to detect this difference:estimating contrast threshold provides information about the quality of vision and helps diagnose and monitor eye diseases.High contrast visual acuity assessment is traditionally performed in the eye care practice,whereas the estimate of the discrimination of low contrast targets,an important complementary task for the perception of details,is far less employed.An example is driving when the contrast between vehicles,obstacles,pedestrians,and the background is reduced by fog.Many conditions can selectively degrade CS,while visual acuity remains intact.In addition to spatial CS,“temporal”CS is defined as the ability to discriminate luminance differences in the temporal domain,i.e.,to discriminate information that reaches the visual cortex as a function of time.Likewise,temporal sensitivity of the visual system can be investigated in terms of critical fusion frequency(CFF),an indicator of the integrity of the magnocellular system that is responsible for the perception of transient stimulations.As a matter of fact,temporal resolution can be abnormal in neuro-ophthalmological clinical conditions.This paper aims at considering CS and its application to the clinical practice. 展开更多
关键词 contrast sensitivity(CS) MAGNOCELLULAR sine-wave grating temporal processing FLICKER
下载PDF
Objective electrophysiological contrast sensitivity with monofocal and multifocal intraocular lenses:a prospective clinical study
13
作者 Salvatore Cillino Giovanni Cillino +4 位作者 Simona Di Naro Aissa Iggui Viviana Firpo Girolamo Maniscalco Alessandra Casuccio 《Annals of Eye Science》 2018年第1期136-146,共11页
Background:To compare objective electrophysiological contrast sensitivity function(CSF)in patients implanted with either multifocal intraocular lenses(MIOLs)or monofocal intraocular lenses(IOLs)by pattern reversal vis... Background:To compare objective electrophysiological contrast sensitivity function(CSF)in patients implanted with either multifocal intraocular lenses(MIOLs)or monofocal intraocular lenses(IOLs)by pattern reversal visual evoked potentials(prVEP)measurements.Methods:Fourty-five cataract patients were randomly allocated to receive bilaterally:apodized diffractive-refractive Alcon Acrysof MIOL(A),full diffractive AMO Tecnis MIOL(B)or monofocal Alcon Acrysof IOL(C).Primary outcomes:1-year differences in objective binocular CSF measured by prVEP with sinusoid grating stimuli of 6 decreasing contrast levels at 6 spatial frequencies.Secondary outcomes:psychophysical CSF measured with VCTS-6500,photopic uncorrected distance(UDVA),and mesopic and photopic uncorrected near and intermediate visual acuities(UNVA and UIVA respectively).Results:Electrophysiological CSF curve had an inverted U-shaped morphology in all groups,with a biphasic pattern in Group B.Group A showed a lower CSF than group B at 4 and 8 cpd,and a lower value than group C at 8 cpd.Psychophysical CSF in group A exhibited a lower value at 12 cpd than group B.Mean photopic and mesopic UNVA and UIVA were worse in monofocal group compared to the multifocal groups.Mesopic UNVA and UIVA were better in group B.Conclusions:Electrophysiological CSF behaves differently depending on the types of multifocal or monofocal IOLs.This may be related to the visual acuity under certain conditions or to IOL characteristics.This objective method might be a potential new tool to investigate on MIOL differences and on subjective device-related quality of vision. 展开更多
关键词 Electrophysiological contrast sensitivity visual evoked potentials(VEPs) multifocal intraocular lens(MIOLs) prospective clinical study
下载PDF
Prediction of radiosensitivity in primary central nervous system germ cell tumors using dynamic contrast-enhanced magnetic resonance imaging 被引量:3
14
作者 Chenlu Feng Peiyi Gao +4 位作者 Xiaoguang Qiu Tianyi Qian Yan Lin Jian Zhou Binbin Sui 《Chinese Journal of Cancer Research》 SCIE CAS CSCD 2015年第3期231-238,共8页
Objective: To evaluate the feasibility of dynamic contrast-enhanced magnetic resonance imaging(DCEMRI) for predicting tumor response to radiotherapy in patients with suspected primary central nervous system(CNS) ... Objective: To evaluate the feasibility of dynamic contrast-enhanced magnetic resonance imaging(DCEMRI) for predicting tumor response to radiotherapy in patients with suspected primary central nervous system(CNS) germ cell tumors(GCTs).Methods: DCE-MRI parameters of 35 patients with suspected primary CNS GCTs were obtained prior to diagnostic radiation, using the Tofts and Kermode model. Radiosensitivity was determined in tumors diagnosed 2 weeks after radiation by observing changes in tumor size and markers as a response to MRI. Taking radiosensitivity as the gold standard, the cut-off value of DCE-MRI parameters was measured by receiver operating characteristic(ROC) curve. Diagnostic accuracy of DCE-MRI parameters for predicting radiosensitivity was evaluated by ROC curve.Results: A significant elevation in transfer constant(K^trans) and extravascular extracellular space(Ve)(P=0.000), as well as a significant reduction in rate constant(Kep)(P=0.000) was observed in tumors. K^trans, relative K^trans, and relative Kep of the responsive group were significantly higher than non-responsive groups. No significant difference was found in Kep, Ve, and relative Ve between the two groups. Relative K^trans showed the best diagnostic value in predicting radiosensitivity with a sensitivity of 100%, specificity of 91.7%, positive predictive value(PPV) of 95.8%, and negative predictive value(NPV) of 100%.Conclusions: Relative K^trans appeared promising in predicting tumor response to radiation therapy(RT). It is implied that DCE-MRI pre-treatment is a requisite step in diagnostic procedures and a novel and reliable approach to guide clinical choice of RT. 展开更多
关键词 Dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) extravascular extracellular space germ cell tumors (GCTs) RADIOsensitivity rate constant transfer constant
下载PDF
A Rapid Adaptation Approach for Dynamic Air‑Writing Recognition Using Wearable Wristbands with Self‑Supervised Contrastive Learning
15
作者 Yunjian Guo Kunpeng Li +4 位作者 Wei Yue Nam‑Young Kim Yang Li Guozhen Shen Jong‑Chul Lee 《Nano-Micro Letters》 SCIE EI CAS 2025年第2期417-431,共15页
Wearable wristband systems leverage deep learning to revolutionize hand gesture recognition in daily activities.Unlike existing approaches that often focus on static gestures and require extensive labeled data,the pro... Wearable wristband systems leverage deep learning to revolutionize hand gesture recognition in daily activities.Unlike existing approaches that often focus on static gestures and require extensive labeled data,the proposed wearable wristband with selfsupervised contrastive learning excels at dynamic motion tracking and adapts rapidly across multiple scenarios.It features a four-channel sensing array composed of an ionic hydrogel with hierarchical microcone structures and ultrathin flexible electrodes,resulting in high-sensitivity capacitance output.Through wireless transmission from a Wi-Fi module,the proposed algorithm learns latent features from the unlabeled signals of random wrist movements.Remarkably,only few-shot labeled data are sufficient for fine-tuning the model,enabling rapid adaptation to various tasks.The system achieves a high accuracy of 94.9%in different scenarios,including the prediction of eight-direction commands,and air-writing of all numbers and letters.The proposed method facilitates smooth transitions between multiple tasks without the need for modifying the structure or undergoing extensive task-specific training.Its utility has been further extended to enhance human–machine interaction over digital platforms,such as game controls,calculators,and three-language login systems,offering users a natural and intuitive way of communication. 展开更多
关键词 Wearable wristband Self-supervised contrastive learning Dynamic gesture Air-writing Human-machine interaction
下载PDF
Effect of astigmatism and spherical equivalent correction on contrast sensitivity
16
作者 Maryam Saffarizadeh Saeed Rahmani +1 位作者 Alireza Akbarzadeh Baghban Mohammad Ghassemi-Broumand 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2024年第12期2243-2247,共5页
AIM:To investigate the effect of astigmatism and spherical equivalent(SE)correction on contrast sensitivity(CS).METHODS:In this cross-sectional study,103 visually normal subjects aged 18 to 36y with bilateral regular ... AIM:To investigate the effect of astigmatism and spherical equivalent(SE)correction on contrast sensitivity(CS).METHODS:In this cross-sectional study,103 visually normal subjects aged 18 to 36y with bilateral regular astigmatism in range of 1.00 diopter cylinder(DC)to 4.00 DC and normal best-corrected visual acuity(20/20)were recruited.Binocular CS was assessed by linear sine-wave gratings at 1.5,3,6,12,and 18 cycles per degree(cpd),before correction of astigmatism,after full correction of astigmatism by cylindrical spectacle lenses,and after SE of refractive error.The repeated measures ANOVA and Bonferroni test were used to compare the effects of astigmatism correction on logCS.RESULTS:Totally 39 patients were male and 64 patients were female with the mean age of 28.25±5.38y.The average degree of astigmatism in right and left eye was 2.03±0.83 and 2.10±0.78,respectively.Increases in uncorrected astigmatic power correlated with decreases in the logCS,especially at high spatial frequencies.A statistically significant difference in logCS was found between these three cases:before correction of astigmatism,after SE of refractive error,and after full correction of astigmatism by cylindrical spectacle lenses at all frequencies(P<0.001),except at 18 cpd.At 18 cpd,there was no statistically significant difference between logCS before and after SE of refractive error(P=1.0).Also,there was no statistically significant difference in mean CS between with-the-rule(WTR)and against-the-rule(ATR)astigmatism,before correction of astigmatism,after correction of astigmatism with cylindrical lenses,and after SE of refractive error.CONCLUSION:Binocular astigmatism defocus decreases CS depending on the degree of astigmatism power;correction of this will improve patent’s quality of vision.Although high astigmatism refractive error(more than 2.00 DC)that is fully corrected by cylindrical spectacle lenses doesn’t increase the CS to the maximum value,especially at higher spatial frequencies(12 and 18).Also SE refractive error effects on improving CS in low astigmatism power(less than 2.00 DC),especially at lower spatial frequencies. 展开更多
关键词 astigmatism contrast sensitivity spherical equivalent
下载PDF
Ultra‑High Sensitivity Anisotropic Piezoelectric Sensors for Structural Health Monitoring and Robotic Perception
17
作者 Hao Yin Yanting Li +4 位作者 Zhiying Tian Qichao Li Chenhui Jiang Enfu Liang Yiping Guo 《Nano-Micro Letters》 SCIE EI CAS 2025年第2期432-446,共15页
Monitoring minuscule mechanical signals,both in magnitude and direction,is imperative in many application scenarios,e.g.,structural health monitoring and robotic sensing systems.However,the piezoelectric sensor strugg... Monitoring minuscule mechanical signals,both in magnitude and direction,is imperative in many application scenarios,e.g.,structural health monitoring and robotic sensing systems.However,the piezoelectric sensor struggles to satisfy the requirements for directional recognition due to the limited piezoelectric coefficient matrix,and achieving sensitivity for detecting micrometer-scale deformations is also challenging.Herein,we develop a vector sensor composed of lead zirconate titanate-electronic grade glass fiber composite filaments with oriented arrangement,capable of detecting minute anisotropic deformations.The as-prepared vector sensor can identify the deformation directions even when subjected to an unprecedented nominal strain of 0.06%,thereby enabling its utility in accurately discerning the 5μm-height wrinkles in thin films and in monitoring human pulse waves.The ultra-high sensitivity is attributed to the formation of porous ferroelectret and the efficient load transfer efficiency of continuous lead zirconate titanate phase.Additionally,when integrated with machine learning techniques,the sensor’s capability to recognize multi-signals enables it to differentiate between 10 types of fine textures with 100%accuracy.The structural design in piezoelectric devices enables a more comprehensive perception of mechanical stimuli,offering a novel perspective for enhancing recognition accuracy. 展开更多
关键词 Flexible piezoelectric filaments ANISOTROPIC Ultra-high sensitivity Structural health detection Texture recognition
下载PDF
Innovative approaches beyond periprocedural hydration for preventing contrast-induced acute kidney injury
18
作者 Chun-Han Cheng Wen-Rui Hao Tzu-Hurng Cheng 《World Journal of Radiology》 2024年第9期375-379,共5页
Contrast-induced acute kidney injury(CI-AKI)is a major concern in clinical practice,particularly among high-risk patients with preexisting renal and cardiovascular conditions.Although periprocedural hydration has long... Contrast-induced acute kidney injury(CI-AKI)is a major concern in clinical practice,particularly among high-risk patients with preexisting renal and cardiovascular conditions.Although periprocedural hydration has long been the primary approach for CI-AKI prevention,recent advancements have led to the development of novel approaches such as RenalGuard and contrast removal systems.This editorial explores these emerging approaches and highlights their potential for enhancing CI-AKI prevention.By incorporating the latest evidence into clinical practice,health-care professionals can more effectively maintain renal function and improve outcomes for patients undergoing contrast-enhanced procedures. 展开更多
关键词 contrast-induced acute kidney injury contrast-induced acute kidney injury prevention Periprocedural hydration RenalGuard contrast removal systems
下载PDF
Navigating nephrotoxic waters:A comprehensive overview of contrast-induced acute kidney injury prevention 被引量:1
19
作者 Panagiotis Theofilis Rigas Kalaitzidis 《World Journal of Radiology》 2024年第6期168-183,共16页
Contrast-induced acute kidney injury(CI-AKI)is the third leading cause of acute kidney injury deriving from the intravascular administration of contrast media in diagnostic and therapeutic procedures and leading to lo... Contrast-induced acute kidney injury(CI-AKI)is the third leading cause of acute kidney injury deriving from the intravascular administration of contrast media in diagnostic and therapeutic procedures and leading to longer in-hospital stay and increased short and long-term mortality.Its pathophysiology,although not well-established,revolves around medullary hypoxia paired with the direct toxicity of the substance to the kidney.Critically ill patients,as well as those with pre-existing renal disease and cardiovascular comorbidities,are more susceptible to CI-AKI.Despite the continuous research in the field of CI-AKI prevention,clinical practice is based mostly on periprocedural hydration.In this review,all the investigated methods of prevention are presented,with an emphasis on the latest evidence regarding the potential of RenalGuard and contrast removal systems for CI-AKI prevention in high-risk individuals. 展开更多
关键词 contrast-induced acute kidney injury contrast media PREVENTION HYDRATION RenalGuard Dyevert
下载PDF
Characterizing permeability-porosity relationships of porous rocks using a stress sensitivity model in consideration of elastic-structural deformation and tortuosity sensitivity
20
作者 Ronghe Xu Liqin Wang +1 位作者 Xiaoli Zhao Yuze Mao 《Journal of Rock Mechanics and Geotechnical Engineering》 SCIE CSCD 2024年第9期3437-3451,共15页
Clarifying the relationship between stress sensitivities of permeability and porosity is of great significance in guiding underground resource mining.More and more studies focus on how to construct stress sensitivity ... Clarifying the relationship between stress sensitivities of permeability and porosity is of great significance in guiding underground resource mining.More and more studies focus on how to construct stress sensitivity models to describe the relationship and obtain a comprehensive stress sensitivity of porous rock.However,the limitations of elastic deformation calculation and incompleteness of considered tortuosity sensitivity lead to the fact that the existing stress sensitivity models are still unsatisfactory in terms of accuracy and generalization.Therefore,a more accurate and generic stress sensitivity model considering elastic-structural deformation of capillary cross-section and tortuosity sensitivity is proposed in this paper.The elastic deformation is derived from the fractal scaling model and Hooke's law.Considering the effects of elastic-structural deformation on tortuosity sensitivity,an empirical formula is proposed,and the conditions for its applicability are clarified.The predictive performance of the proposed model for the permeability-porosity relationships is validated in several sets of publicly available experimental data.These experimental data are from different rocks under different pressure cycles.The mean and standard deviation of relative errors of predicted stress sensitivity with respect to experimental data are 2.63%and 1.91%.Compared with other models,the proposed model has higher accuracy and better predictive generalization performance.It is also found that the porosity sensitivity exponent a,which can describe permeability-porosity relationships,is 2 when only elastic deformation is considered.a decreases from 2 when structural deformation is also considered.In addition,a may be greater than 3 due to the increase in tortuosity sensitivity when tortuosity sensitivity is considered even if the rock is not fractured. 展开更多
关键词 Stress sensitivity model Permeability-porosity relationships Elastic-structural deformation Tortuosity stress sensitivity
下载PDF
上一页 1 2 250 下一页 到第
使用帮助 返回顶部