A new analytical method for the determination of urea-urease system based on biochemical reaction heat induced laser beam deflection is presented in this paper. With the method, the Michaelis constant (K-m) of urease ...A new analytical method for the determination of urea-urease system based on biochemical reaction heat induced laser beam deflection is presented in this paper. With the method, the Michaelis constant (K-m) of urease and apparent inhibition constant (K-i) of some metal ion inhibitors were measured respectively. This method was also used for the quantitative determination of metal ions with satisfactory result.展开更多
A highly sensitive method is developed for the determination of trace amounts of some heavy metal ions in aqueous solution based on the classical Belousov-Zhabotinskii (BZ) oscillating chemical system. Introducing o...A highly sensitive method is developed for the determination of trace amounts of some heavy metal ions in aqueous solution based on the classical Belousov-Zhabotinskii (BZ) oscillating chemical system. Introducing of S^2- ion makes the new oscillating system Ce(SO4)2 - KBrO3 - CH2(COOH)2 - Na2S - H2SO4 have to a high sensitivity for some heavy metal ions such as Ag^+, Pb^2+, Hg^2+, Cd^2+, Cu^2+and Bi^3+ with detection limits down to 10^-12 mol·L^- 1展开更多
An overview of extraction of some trace metal ions using molten solvent (lowmelting substance) during last two decades is presented. The development of this technique since itsinception is briefly traced. The comparis...An overview of extraction of some trace metal ions using molten solvent (lowmelting substance) during last two decades is presented. The development of this technique since itsinception is briefly traced. The comparison of extraction efficiency, thermodynamics and kineticsmainly involving extraction of rare earth ions between molten solvent extraction at high temperatureand usual liquid-liquid extraction at room temperature are discussed in detail. The variousparameters obtained from the previous and present studies such as equilibrium extraction constantK_(ex), pH_(1/2), thermodynamic and kinetic data are displayed in tabular form. Finally, the currentdemands, disadvantages and future prospects are also evaluated.展开更多
文摘A new analytical method for the determination of urea-urease system based on biochemical reaction heat induced laser beam deflection is presented in this paper. With the method, the Michaelis constant (K-m) of urease and apparent inhibition constant (K-i) of some metal ion inhibitors were measured respectively. This method was also used for the quantitative determination of metal ions with satisfactory result.
基金supported in part by the Project of International Cooperation between China and Ukraine(043-05)the National Natural Science Foundation(No.20475044)the Invention Project of Science&Technology(KJCXGC-01,NWNU),China.
文摘A highly sensitive method is developed for the determination of trace amounts of some heavy metal ions in aqueous solution based on the classical Belousov-Zhabotinskii (BZ) oscillating chemical system. Introducing of S^2- ion makes the new oscillating system Ce(SO4)2 - KBrO3 - CH2(COOH)2 - Na2S - H2SO4 have to a high sensitivity for some heavy metal ions such as Ag^+, Pb^2+, Hg^2+, Cd^2+, Cu^2+and Bi^3+ with detection limits down to 10^-12 mol·L^- 1
基金This work was financially supported by the Project of KJCXGC-01 of Northwest Normal University,and the Gansu Province Nature Science Foundation(ZR96016).]
文摘An overview of extraction of some trace metal ions using molten solvent (lowmelting substance) during last two decades is presented. The development of this technique since itsinception is briefly traced. The comparison of extraction efficiency, thermodynamics and kineticsmainly involving extraction of rare earth ions between molten solvent extraction at high temperatureand usual liquid-liquid extraction at room temperature are discussed in detail. The variousparameters obtained from the previous and present studies such as equilibrium extraction constantK_(ex), pH_(1/2), thermodynamic and kinetic data are displayed in tabular form. Finally, the currentdemands, disadvantages and future prospects are also evaluated.