期刊文献+
共找到3,561篇文章
< 1 2 179 >
每页显示 20 50 100
Impact of Atrial Septal Defect Closure on Mortality in Older Patients
1
作者 Sipawath Khamplod Yodying Kaolawanich +1 位作者 Khemajira Karaketklang Nithima Ratanasit 《Congenital Heart Disease》 SCIE 2024年第1期93-105,共13页
Background:Atrial septal defect(ASD)is a common form of adult congenital heart disease that can lead to long-term adverse outcomes if left untreated.Early closure of ASD has been associated with excellent outcomes and... Background:Atrial septal defect(ASD)is a common form of adult congenital heart disease that can lead to long-term adverse outcomes if left untreated.Early closure of ASD has been associated with excellent outcomes and lower complication rates.However,there is limited evidence regarding the prognosis of ASD closure in older adults.This study aims to evaluate the mortality rates in older ASD patients with and without closure.Methods:A retrospective cohort study was conducted on patients aged 40 years or older with ASD between 2001 and 2017.Patients were followed up to assess all-cause mortality.Univariable and multivariable analyses were performed to identify the predictors of mortality.A p-value of<0.05 was considered statistically significant.Results:The cohort consisted of 450 patients(mean age 56.6±10.4 years,77.3%female),with 66%aged between 40 and 60 years,and 34%over 60 years.Within the cohort,299 underwent ASD closure(201 with transcatheter and 98 with surgical closure).During the median follow-up duration of 7.9 years,51 patients died.The unadjusted cumulative 10-year rate of mortality was 3%in patients with ASD closure,and 28%in patients without ASD closure(log-rank p<0.001).Multivariable analysis revealed that age(hazard ratio[HR]1.04,95%confidence interval[CI]1.006–1.06,p=0.01),NYHA class(HR 2.75,95%CI 1.63–4.62,p<0.001),blood urea nitrogen(BUN)(HR 1.07,95%CI 1.03–1.12,p<0.001),right ventricular systolic pressure(RVSP)(HR 1.07,95%CI 1.003–1.04,p=0.01),and lack of ASD closure(HR 15.12,95%CI 5.63–40.59,p<0.001)were independently associated with mortality.Conclusion:ASD closure demonstrated favorable outcomes in older patients.Age,NYHA class,BUN,RVSP,and lack of ASD closure were identified as independent factors linked to mortality in this population. 展开更多
关键词 Atrial septal defect congenital heart disease defect closure long-term survival MORTALITY
下载PDF
Surgical Repair of Ventricular Septal Defect in Neonates: Indications and Outcomes
2
作者 Jae Hong Lee Sungkyu Cho +6 位作者 Jae Gun Kwak Hye Won Kwon Woong-Han Kim Mi Kyoung Song Sang-Yun Lee Gi Beom Kim Eun Jung Bae 《Congenital Heart Disease》 SCIE 2024年第1期69-83,共15页
Background:The optimal surgical timing and clinical outcomes of ventricular septal defect(VSD)closure in neo-nates remain unclear.We aimed to evaluate the clinical outcomes of VSD closure in neonates(age≤30 days).Met... Background:The optimal surgical timing and clinical outcomes of ventricular septal defect(VSD)closure in neo-nates remain unclear.We aimed to evaluate the clinical outcomes of VSD closure in neonates(age≤30 days).Methods:We retrospectively reviewed 50 consecutive neonates who underwent VSD closure for isolated VSDs between August 2003 and June 2021.Indications for the procedure included congestive heart failure/failure to thrive and pulmonary hypertension.Major adverse events(MAEs)were defined as the composite of all-cause mortality,reoperation,persistent atrioventricular block,and significant(≥grade 2)valvular dysfunction.Results:The median age and body weight at operation were 26.0 days(interquartile range[IQR],18.8–28.3)and 3.7 kg(IQR,3.3–4.2),respectively.The median follow-up duration was 110.4 months(IQR,56.8–165.0).Seven patients required preoperative respiratory support,andfive had significant(≥grade 2)preoperative valvular dysfunction.One early mortality occurred due to irreversible cardiogenic shock;no late mortality was observed.One reopera-tion was due to hemodynamically significant residual VSD at 103.8 months postoperatively.The overall survival,freedom from reoperation,and freedom from MAE at 15-years were 98.0%,96.3%,and 94.4%,respectively.Pre-operative mechanical ventilation was associated with a longer duration of postoperative mechanical ventilation(p<0.001)and a longer length of intensive care unit stay(p<0.001).Conclusions:VSD closure with favorable outcomes without morbidities is feasible even in neonates.However,neonates requiring preoperative respiratory support may require careful postoperative management considering the long-term postoperative risks.Overall,surgical VSD closure might be indicated earlier in neonates with respiratory compromise. 展开更多
关键词 Ventricular septal defect NEONATE early surgery neonatal surgery
下载PDF
Reliability of Echocardiographic Pulmonary Vascular Resistance to Screen for the New Definition of Precapillary Pulmonary Hypertension in Uncorrected Secundum Atrial Septal Defect
3
作者 Risalina Myrtha Hasanah Mumpuni +3 位作者 Real Kusumanjaya Marsam Dyah Wulan Anggrahini Anggoro Budi Hartopo Lucia Kris Dinarti 《Congenital Heart Disease》 SCIE 2024年第3期315-324,共10页
Background and Objective:The most feared complication of uncorrected secundum Atrial Septal Defect(ASD)is pulmonary arterial hypertension(PAH).Pulmonary vascular resistance(PVR)is crucial in detecting precapil-lary pu... Background and Objective:The most feared complication of uncorrected secundum Atrial Septal Defect(ASD)is pulmonary arterial hypertension(PAH).Pulmonary vascular resistance(PVR)is crucial in detecting precapil-lary pulmonary hypertension(PH)to guide the need for PAH-specific therapy.There is a change in the cut-off value of PVR according to the recently updated PH guideline.How echocardiographic PVR(PVRecho)correlates to PVR by right heart catheterization(RHC)(PVRcath)according to the new guidelines has not been known.The aim of this study is to determine the reliability of PVRecho in detecting PAH in Uncorrected Ostium Secundum ASD based on the current updated guideline and to help screen the high PVR group.Methods:429 ostium secun-dum ASD in the COngenital HeARt Disease in Adult and Pulmonary Hypertension(COHARD-PH)registry was divided into three groups according to the PVR.PVRecho was calculated using Abbas’Formula and compared the its gold standard,the PVRcath.The correlation between the two methods was analyzed.The Bland-Altman plot was used to analyze the agreement between the two methods.Receiver operating characteristics(ROC)analysis was used to determine the PVRecho cut-off value for high PVR.Results:The majority of the population(63.5%)had high PVR.Female gender dominated the study population(84%).PVR_(echo) was significantly correlated with PVRcath(r=0.6225,p<0.0001).Bland-Altman plot among all groups and in subgroups analysis showed a wide range of agreement.PVRecho underestimated PVRcath 5.124 WU.In subgroup analysis,PVRecho overestimated PVRcath 0.35 WU in those with PVR<2 WU.In the second and third groups,PVR_(echo) underestimated PVRcath 0.52 and 10.77 WU,respectively.Conclusion:PVRecho is reliable in predicting high PVR in uncorrected secun-dum ASD.However,there is a wide range of agreement.PVR_(echo) cut-off value of>1.62 WU showed good dis-criminatory power in determining high PVR. 展开更多
关键词 Pulmonary vascular resistance atrial septal defect ECHOCARDIOGRAPHY
下载PDF
Intelligent diagnosis of atrial septal defect in children using echocardiography with deep learning
4
作者 Yiman LIU Size HOU +7 位作者 Xiaoxiang HAN Tongtong LIANG Menghan HU Xin WANG Wei GU Yuqi ZHANG Qingli LI Jiangang CHEN 《虚拟现实与智能硬件(中英文)》 EI 2024年第3期217-225,共9页
Background Atrial septal defect(ASD)is one of the most common congenital heart diseases.The diagnosis of ASD via transthoracic echocardiography is subjective and time-consuming.Methods The objective of this study was ... Background Atrial septal defect(ASD)is one of the most common congenital heart diseases.The diagnosis of ASD via transthoracic echocardiography is subjective and time-consuming.Methods The objective of this study was to evaluate the feasibility and accuracy of automatic detection of ASD in children based on color Doppler echocardiographic static images using end-to-end convolutional neural networks.The proposed depthwise separable convolution model identifies ASDs with static color Doppler images in a standard view.Among the standard views,we selected two echocardiographic views,i.e.,the subcostal sagittal view of the atrium septum and the low parasternal four-chamber view.The developed ASD detection system was validated using a training set consisting of 396 echocardiographic images corresponding to 198 cases.Additionally,an independent test dataset of 112 images corresponding to 56 cases was used,including 101 cases with ASDs and 153 cases with normal hearts.Results The average area under the receiver operating characteristic curve,recall,precision,specificity,F1-score,and accuracy of the proposed ASD detection model were 91.99,80.00,82.22,87.50,79.57,and 83.04,respectively.Conclusions The proposed model can accurately and automatically identify ASD,providing a strong foundation for the intelligent diagnosis of congenital heart diseases. 展开更多
关键词 Deep learning Atrial septal defect ECHOCARDIOGRAPHY
下载PDF
Genetic Analysis of Variants of the MYH6 Gene Promoter in Congenital Atrial Septal Defects 被引量:1
5
作者 Ji-Yang Zuo Huan-Xin Chen +2 位作者 Zhi-Gang Liu Qin Yang Guo-Wei He 《Congenital Heart Disease》 SCIE 2023年第1期7-21,共15页
Background:Atrial septal defect(ASD)is one of the common congenital heart diseases.The MYH6 gene has a critical role in cardiac development but the role of MYH6 promoter variants in patients with ASD has not been expl... Background:Atrial septal defect(ASD)is one of the common congenital heart diseases.The MYH6 gene has a critical role in cardiac development but the role of MYH6 promoter variants in patients with ASD has not been explored.Methods:In 613 subjects including 320 ASD patients,we investigated the MYH6 gene promoter variants and verified the effect on gene expression by using cellular functional experiments and bioinformatics analysis.Results:Eleven variants were identified in the MYH6 gene promoter,of which four variants were found only in ASD patients,and two variants(g.3434G>C and g.4524C>T)were identified for the first time.Cellular functional experiments indicated that all four variants reduced the transcriptional activity of the MYH6 gene promoter(p<0.05).Subsequent analysis through the JASPAR(A database of transcription factor binding profiles)suggests that these variants may alter transcription factor binding sites,which may in turn lead to changes in myocardin subunit expression and ASD formation.Conclusions:Our study for the first time focuses on variants in the promoter region of the MYH6 gene in Chinese patients with ASD and the discovered variants have functional significance.The study provides new insights in the role of the MYH6 gene promoter region to better understand the genetic basis of ASD formation and facilitates clinical diagnosis. 展开更多
关键词 Atrial septal defect MYH6 GENETIC VARIANTS congenital heart disease
下载PDF
Transcatheter Ventricular Septal Defect Closure with Nit-Occlud LêVSD Device—Five Years’Experience and Literature Review
6
作者 Ivana B.Cerović Vladislav A.Vukomanović +6 位作者 Jovan Lj.Košutić Mila S.Stajević Sanja S.Ninić Saša S.Popović Ivan D.Dizdarević Staša D.Krasić Sergej M.Prijić 《Congenital Heart Disease》 SCIE 2023年第3期361-371,共11页
Introduction:Transcatheter closure is an alternative to ventricular septal defect(VSD)occlusion surgery.Nit-Occlud LêVSD coil is a new device yet to be evaluated.The study aimed to evaluate immediate and midterm ... Introduction:Transcatheter closure is an alternative to ventricular septal defect(VSD)occlusion surgery.Nit-Occlud LêVSD coil is a new device yet to be evaluated.The study aimed to evaluate immediate and midterm results after transcatheter closure with the Nit-Occlud LêVSD device.Methods:The retrospective analysis included 30 patients with VSD referred for closure during the period from October 2015 to December 2020.Results:At the time of intervention,the patients’mean age and body weights were 7.5±5.6 years and 29.3±19.1 kg.The majority of the defects had perimembranous location(24/30),four defects had muscular and two outlet subaortic position.The mean effective right-side diameter of the VSDs was 3.6±1.3 mm.Single ventricular fibrillation,device embolization,and hemolysis developed in different patients and were successfully treated.None of the patients had a complete atrioventricular block.The coil was successfully placed in 25/30(83.3%)patients.The majority of the devices were 10 mm×6 mm(11/25)and 12 mm×8 mm(8/25)in size.Two patients required the implantation of a second device.The follow-up period was 2.1±1.4 years.Complete VSD closure was achieved in 48%of cases immediately after the intervention,74%during 2.1±1.6 months after the procedure,and 81%over follow-up.The remaining patients had a trivial residual defect.During the follow-up,approximately one-third of patients developed trivial aortic and mitral valve regurgitation,and half of the patients acquired trace/mild tricuspid regurgitation.Standardized(z-score)left ventricular end-diastolic diameter(0.15±0.37 vs.0.92±0.82,p=0.005)and left atrium dimension(0.47±0.58 vs.1.89±1.11,p=0.005),as well as the left atrium to aortic root ratio(1.2±0.1 vs.1.4±0.2,p=0.005)showed a significant decrease over follow-up related to the period before intervention.Conclusion:Intervention with Nit-OccludLêVSD coil showed appropriate results regarding VSD closure rate,complications,and chamber remodeling.The introduction of this device into clinical practice is a significant step forward in transcatheter perimembranous VSD occlusion. 展开更多
关键词 Ventricular septal defect TRANSCATHETER DEVICE children
下载PDF
Mortality Rates of Ventricular Septal Defect for Children in Kazakhstan: Spatio-Temporal Epidemiological Appraisal
7
作者 Akkerbez Adilbekova Shukhrat Marassulov +2 位作者 Bakhytzhan Nurkeev Saken Kozhakhmetov Aikorkem Badambekova 《Congenital Heart Disease》 SCIE 2023年第4期447-459,共13页
Objective: The aim is to study the trends in ventricular septal defect (VSD) mortality in children in Kazakhstan.Methods: The retrospective study was done for the period 2011–2020. Descriptive and analytical methods ... Objective: The aim is to study the trends in ventricular septal defect (VSD) mortality in children in Kazakhstan.Methods: The retrospective study was done for the period 2011–2020. Descriptive and analytical methods of epidemiologywere applied. The universally acknowledged methodology used in sanitary statistics is used to calculatethe extensive, crude, and age-specific mortality rates. Results: Kazakhstan is thought to be seeing an increase inmortality from VSDs in children. As a result, this study for the years 2011 to 2020 was conducted to retrospectivelyassess data from the central registration of the Bureau of National Statistics that was available throughoutthe nation. Age-standardized mortality data were obtained and compared between age categories. It was shownthat 507 children died from this condition throughout the time period under study. The average annual standardizedmortality rate was 1.88 per 100,000 population and tended to decrease over time. The peak of mortality wasnoted at the age of up to 1 year, namely the neonatal period. Cartogram mortality rates were calculated usingstandardized indicators. Additionally, age-sex variations were taken into account when performing all calculations.Conclusion: In recent years, the death rate from VSD has declined from 1.5 to 0.6 per 100,000 people, withthe trend remaining constant (T = 1.4%, R^(2) = 0.5825). The analysis of mortality trends related to VSD is crucial inboth theoretical and practical aspects, as it enables early detection and treatment of VSDs. The findings of thisstudy will be valuable to public health authorities in developing a strategy to treat VSDs effectively. 展开更多
关键词 Ventricular septal defect children mortality geographical variation kazakhstan
下载PDF
“Treat-Repair-Treat”:Management of Left Main Coronary Compression by a Pulmonary Artery Aneurysm in a Patient with Atrial Septal Defect and Significant Pulmonary Hypertension
8
作者 Andrei George Iosifescu Roxana Enache +2 位作者 Ioana Marinică Corina Radu Vlad Anton Iliescu 《Congenital Heart Disease》 SCIE 2023年第1期67-72,共6页
Left main coronary compression syndrome(LMCS)may complicate pulmonary artery aneurysms(PAA),usually developed in the context of pulmonary arterial hypertension(PAH).We report the case of a 51-year-old female patient w... Left main coronary compression syndrome(LMCS)may complicate pulmonary artery aneurysms(PAA),usually developed in the context of pulmonary arterial hypertension(PAH).We report the case of a 51-year-old female patient with an atrial septal defect(unsuitable for device closure)complicated by a PAA generating a 90%left main stenosis.The significant PAH held us back from immediate surgery.After specific dual PAH-targeted therapy(sildenafil and bosentan),the atrial septal defect could be closed with a unidirectional valved patch;the PAAinduced LMCS was treated by reductive arterioplasty.The postoperative course was uneventful.Follow-up showed clinical improvement,but PAH treatment was still needed.After three months,coronary angiography showed only an insignificant residual left main stenosis,proving that reductive pulmonary arterioplasty was effective in treating LMCS.Any PAA requires further evaluation for LMCS,a dangerous but treatable complication.The“treat-repair-treat”strategy and shunt-closure with a unidirectional valved patch can both improve surgical prospects of LMCS with shunt-related PAH. 展开更多
关键词 Atrial septal defect pulmonary arterial hypertension pulmonary artery aneurysm left main coronary compression syndrome surgery unidirectional valved patch
下载PDF
The Effect of Atrial Septal Defect Closure on Cardiac Volumetric Changes in Adults, Transcatheter Versus Surgical Closure, a Pilot Cardiac Magnetic Resonance Study
9
作者 Amr Mansour Noha M.Gamal +3 位作者 Alaa M.Nady Amr Ibraheem Dalia M.Salah Khaled M.El-Maghraby 《Congenital Heart Disease》 SCIE 2023年第6期679-691,共13页
Background:Closure of an atrial septal defect(ASD)reduces right-side heart volumes by abolishing shunting with simultaneous improvement of the left ventricle(LV)filling and functions due to ventricular interdependence,... Background:Closure of an atrial septal defect(ASD)reduces right-side heart volumes by abolishing shunting with simultaneous improvement of the left ventricle(LV)filling and functions due to ventricular interdependence,thereby improving symptoms.Furthermore,studies conducted on atrial volume changes after ASD closure are limited.Cardiac magnetic resonance(CMR)is considered as the gold standard method for measuring cardiac volume and mass.Objective:We aimed to study the effect of transcatheter and surgical closure of secundum ASD on cardiac volumes and systolic functions as well as the fate of tricuspid regurgitation(TR),using CMR analysis.Methods:We prospectively enrolled 30 adult patients with isolated secundum ASD who were referred to ASD closure.CMR evaluation of cardiac chambers indexed volumes,systolic function,myocardial mass index,and tricuspid regurgitant fraction were done at before and 6 months after closure.Results:RV volumes decreased in both groups when compared to baseline(p-value 0.001),the device group had more reduction in volumes and more improvement in RV function after closure(p-value 0.001)when compared to the surgical arm.The changes in the RV mass index were insignificant between both groups(p-value 0.31).Functional TR improved to the same extent in both groups.Left ventricular end diastolic volume index(LVEDVI)and LV mass index increased sig-nificantly in both groups when compared to baseline in both groups but with no difference between groups p-value 0.01),left ventricular end systolic volume index(LVESVI)changes were insignificant.LV systolic function improved in patients who underwent device closure only(63.53±3.85 vs.67.13±4.34,p-value 0.01).There was a significant reduction in right atrial(RA)volumes and an insignificant decrease in left atrial(LA)volumes,with no difference between groups.Conclusion:Transcatheter and surgical secundum ASD closure resulted in volumetric changes in some cardiac chambers with better improvement in bi-ventricular systolic function in the transcatheter arm and no difference in the TR reduction between the two groups at 6 months follow-up by CMR. 展开更多
关键词 Atrial septal defect closure cardiac volumetric changes functional tricuspid regurgitation cardiac CMR
下载PDF
Outcomes of Transcatheter Closure in Outlet-Type Ventricular Septal Defect after 1 Year
10
作者 Supaporn Roymanee Nantawan Su-angka +4 位作者 Worakan Promphan Kanjarut Wongwaitaweewong Jirayut Jarutach Rujira Buntharikpornpun Pimpak Prachasilchai 《Congenital Heart Disease》 SCIE 2023年第2期169-182,共14页
Background:Ventricular septal defect(VSD)is the most common congenital heart disease.Transcatheter VSD closure is an effective treatment for patients with muscular and perimembranous VSD.However,there is a limit data ... Background:Ventricular septal defect(VSD)is the most common congenital heart disease.Transcatheter VSD closure is an effective treatment for patients with muscular and perimembranous VSD.However,there is a limit data for outlet VSD,especially impact to the aortic valve leaflet after transcatheter closure.This study aims to assess the outcomes of transcatheter closure of the outlet-type ventricular septal defect(OVSD)after 1 postoperative year.Methods:A retrospective study was performed including 50 patients who underwent transcatheter(n=25)and surgical(n=25)OVSD closure during the exact time frame at two medical centres.Results:The median age and body weight of patients in the transcatheter group were significantly higher than those of patients in the surgical group(7.0 vs.2.8 years;27.0 vs.11.4 kg;p<0.01).The defect size in the surgical group was significantly larger than that in the transcatheter group(5.0 vs.3.0 mm;p<0.01).All OVSD patients have successful transcatheter closure(100%)as effective as surgical closure.Less than small residual shunt was present 20%and 8%immediately after the procedure in the transcatheter and surgical groups(p=0.50),which decreased to 12%and 4%at the 1-year follow-up(p=0.61),respectively.No incidence of complete atrioventricular block and other complications was observed in both groups,and no significant differences were noted in the new onset or worsening of the aortic regurgitation in both groups(p=1.0).Conclusions:Transcatheter treatment could be effectively and safely achieved for OVSD closure at 1-year follow-up. 展开更多
关键词 Outlet ventricular septal defect aortic valve prolapse aortic regurgitation transcatheter closure OUTCOME INTERVENTION
下载PDF
Effects of General Anesthesia on the Results of Cardiac Catheterization in Pediatric Patients with Ventricular Septal Defect
11
作者 Kiyotaka Go Taichi Kato +5 位作者 Machiko Kito Yoshihito Morimoto Satoru Kawai Hidenori Yamamoto Yoshie Fukasawa Kazushi Yasuda 《Congenital Heart Disease》 SCIE 2023年第2期235-243,共9页
Background:There is no gold standard sedation method for pediatric cardiac catheterization.In congenital heart diseases with intracardiac shunts,hemodynamic parameters are prone to change depending on the ventilation ... Background:There is no gold standard sedation method for pediatric cardiac catheterization.In congenital heart diseases with intracardiac shunts,hemodynamic parameters are prone to change depending on the ventilation conditions and anesthetics,although few studies have examined these effects.The purpose of this study was to investigate the effects of two different sedation methods on the hemodynamic parameters.Methods:This study retrospectively evaluated consecutive patients with ventricular septal defect(VSD)below 1 year of age who underwent cardiac catheterization at Aichi Children’s Health and Medical Center,who were divided into age-and VSD diameter-matched general anesthesia(GA)and monitored anesthesia care(MAC)under the natural airway groups(n=40 each),for comparison of hemodynamic parameters.Results:In the GA group,arterial blood pH and arterial partial pressure of oxygen were significantly higher(p<0.01),whereas arterial partial pressure of carbon dioxide was significantly lower than in the MAC group(p<0.01).Mean pulmonary artery pressure(p<0.05)and systemic blood pressure(p<0.01)were lower in the GA group.Pulmonary vascular resistance index(p<0.01)and systemic vascular resistance index(p<0.01)were also significantly lower in the GA group than the MAC group.There were no significant differences in pulmonary blood flow index,systemic blood flow index,and pulmonary/systemic blood flow ratio between the two groups.Conclusions:Cardiac catheterization under GA in VSD patients results in different hemodynamic parameters compared to that under MAC.In particular,when using pulmonary artery pressure and pulmonary vascular resistance measured under GA for judgment regarding the surgical indications or perioperative management,consideration should be given to the fact that these parameters might be lower compared to those measured under MAC. 展开更多
关键词 Ventricular septal defect cardiac catheterization general anesthesia monitored anesthesia care
下载PDF
Effectiveness and Safety of Transcatheter Closure of Various Ventricular Septal Defects Using Second-Generation Amplatzer Duct Occluders
12
作者 Jianming Wang Qiguang Wang +3 位作者 Xiaotang Sheng Jingsong Geng Jiawang Xiao Xianyang Zhu 《Congenital Heart Disease》 SCIE 2023年第2期183-195,共13页
Objective:This study was designed to determine the long-term safety and efficacy of using the Amplatzer Duct Occluder II(ADO II)for the closure of various ventricular septal defects(VSDs).Methods:From January 2011 to ... Objective:This study was designed to determine the long-term safety and efficacy of using the Amplatzer Duct Occluder II(ADO II)for the closure of various ventricular septal defects(VSDs).Methods:From January 2011 to December 2019,selected VSD patients were treated through transcatheter intervention using ADO II occluders.The closure results and complications from 188 patients,involving 167 perimembranous ventricular septal defects(pmVSDs),9 intracristal VSDs,11 post surgery residual shunts and 1 post closure residual shunt with the mean outlet diameter3.1±0.8 mm under angiography,were enrolled in this study.Results:The success rate was 98.9%for all procedures.During the median 77-month follow-up period,no cases of complete atrioventricular block(cAVB),infective endocarditis or death occurred.One major adverse event(0.5%)was recorded:cerebrovascular accident occurred 1 day after the procedure in one patient who was transferred to the neurology department.The residual shunt rate was 44.6%,which was the most common minor adverse event.The cardiac conduction block rate was 4.3%.Specifically,one pmVSD patient developed intermittent LBBB during the 28-month follow-up.There were 3 patients(1.6%)with new-onset mild tricuspid insufficiency,and the insufficiency degree was stable during follow-up.There was no new-onset aortic insufficiency that occurred.Conclusions:Transcatheter closure of pmVSDs,some intracristal VSDs,some postsurgery or postclosure residual shunts using ADO II occluders were both safe and effective and yielded excellent long-term results in selected patients. 展开更多
关键词 Ventricular septal defects Amplatzer Duct Occluder II long-term follow-up transcatheter closure
下载PDF
Completed atrioventricular block induced by atrial septal defect occluder unfolding:A case report
13
作者 Chuan He Yang Zhou +2 位作者 Si-Si Tang Li-Hong Luo Kun Feng 《World Journal of Clinical Cases》 SCIE 2020年第22期5715-5721,共7页
BACKGROUND An atrial septal defect is a common condition and accounts for 25%of adult congenital heart diseases.Transcatheter occlusion is a widely used technique for the treatment of secondary aperture-type atrial se... BACKGROUND An atrial septal defect is a common condition and accounts for 25%of adult congenital heart diseases.Transcatheter occlusion is a widely used technique for the treatment of secondary aperture-type atrial septal defects(ASDs).CASE SUMMARY A 30-year-old female patient was diagnosed with ASD by transthoracic echocardiography(TTE)1 year ago.The electrocardiogram showed a heart rate of 88 beats per minute,normal sinus rhythm,and no change in the ST-T wave.After admission,TTE showed an atrial septal defect with a left-to-right shunt,aortic root short-axis section with an ASD diameter of 8 mm,a parasternal four-chamber section with an ASD diameter of 9 mm,and subxiphoid biatrial section with a diameter of 13 mm.Percutaneous occlusion was proposed.The intraoperative TTE scan showed that the atrial septal defect was oval in shape,was located near the root of the aorta,and had a maximum diameter of 13 mm.A 10-F sheath was placed in the right femoral vein,and a 0.035°hard guidewire was used to establish the transport track between the left pulmonary vein and the inferior vena cava.A shape-memory alloy atrial septal occluder with a waist diameter of 20 mm was placed successfully and located correctly.TTE showed that the double disk unfolded well and that the clamping of the atrial septum was smooth.Immediately after the disc was revealed,electrocardiograph monitoring showed that the ST interval of the inferior leads was prolonged,the P waves and QRS waves were separated,a junctional escape rhythm maintained the heart rate,and the blood pressure began to decrease.After removing the occluder,the elevation in the ST segment returned to normal immediately,and the sinus rhythm returned to average approximately 10 min later.After consulting the patient’s family,we finally decided to withdraw from the operation.CONCLUSION Compression of the small coronary artery,which provides an alternative blood supply to the atrioventricular nodule during the operation,leads to the emergence of a complete atrioventricular block. 展开更多
关键词 Completed atrioventricular block Atrial septal defect occluder Atrial septal defect Transthoracic echocardiography Case report
下载PDF
Percutaneous closure of secundum type atrial septal defects:More than 5-year follow-up 被引量:6
14
作者 Roel JR Snijder Maarten J Suttorp +1 位作者 Jurrien M Ten Berg Martijn C Post 《World Journal of Cardiology》 CAS 2015年第3期150-156,共7页
AIM: To investigate long-term efficacy of two different devices more than five years after percutaneous atrial septal defect(ASD) closure in adults.METHODS: All patients who underwent percutaneous closure of an ASD in... AIM: To investigate long-term efficacy of two different devices more than five years after percutaneous atrial septal defect(ASD) closure in adults.METHODS: All patients who underwent percutaneous closure of an ASD in the St. Antonius Hospital, Nieuwegein, The Netherlands, between February 1998 and December 2006 were included. Percutaneous closure took place under general anaesthesia and transesophageal echocardiographic moni toring. Transthoracic echocardiography(TTE) was performed 24 h post-procedure to visualize the device position and to look for residual shunting using color Doppler. All complications were registered. All patients were invited for an outpatient visit and contrast TTE more than 5-years after closure. Efficacy was based on the presence of a residual right-to-left shunt(RLS), graded as minimal, moderate or severe. The presence of a residual left-to-right shunt(LRS) was diagnosed using color Doppler, and was not graded. Descriptive statistics were used for patients' characteristics. Univariate analysis was used to identify predictors for residual shunting.RESULTS: In total, 104 patients(mean age 45.5 ± 17.1 years) underwent percutaneous ASD closure using an Amplatzer device(ASO) in 76 patients and a Cardioseal/Starflex device(CS/SF) in 28 patients. The mean follow-up was 6.4 ± 3.4 years. Device migration occurred in 4 patients of whom two cases occurred during the index hospitalization(1 ASO, 1 CS/SF). The other 2 cases of device migration occurred during the first 6 mo of follow-up(2 CS/SF). The recurrent thrombo-embolic event rate was similar in both groups: 0.4% per follow-up year. More than 12 mo post-ASD closure and latest follow-up, new-onset supraventricular tachyarrhythmia's occurred in 3.9% and 0% for the ASO and CS/SF group, respectively. The RLS rate at latest follow-up was 17.4%(minimal 10.9%, moderate 2.2%, severe 4.3%) and 45.5%(minimal 27.3%, moderate 18.2%, severe 0%) for the ASO- and CS/SF groups, respectively. There was no residual LRS in both groups.CONCLUSION: Percutaneous ASD closure has good long-term safety and efficacy profiles. The residual RLS rate seems to be high more than 5 years after closure, especially in the CS/SF. Residual LRS was not observed. 展开更多
关键词 Percutaneous intervention Atrial septal defect Closure device Right-to-left interatrial shunt Left-to-right interatrial shunt ECHOCARDIOGRAPHY
下载PDF
Delayed cardiac tamponade after simultaneous transcatheter atrial septal defect closure and left atrial appendage closure device implantation: a particular case report 被引量:2
15
作者 Jian-Ming WANG Qi-Guang WANG Xian-Yang ZHU 《Journal of Geriatric Cardiology》 SCIE CAS CSCD 2019年第12期898-901,共4页
Percutaneous left atrial appendage(LAA)occlusion evolved as an alternative treatment to the patients who are contraindicated or cannot tolerate oral anticoagulants with nonvalvular atrial fibrillation(AF)at risk of st... Percutaneous left atrial appendage(LAA)occlusion evolved as an alternative treatment to the patients who are contraindicated or cannot tolerate oral anticoagulants with nonvalvular atrial fibrillation(AF)at risk of stroke or systemic embolism.[1]Abnormal hemodynamic changes in elder atrial septal defect(ASD)patients cause remodeling of the left atrium,which eventually leads to right heart failure.[2]As the ASDs elderly are associated with a higher incidence of AF,simultaneous transcatheter ASD and LAA closure has become a new effective therapeutic strategy.However,only a limited number of articles involving cardiac tamponade complications have been published in the literature.What’s more,previous studies involving early hemodynamically irrelevant pericardial effusion after the procedure attribute to multiple repositioning attempts of LAA occluder or delivery sheath injured the atrial wall. 展开更多
关键词 Atrial fibrillation Atrial septal defect Cardiac catheterization Cardiac tamponade Left atrial appendage
下载PDF
Evaluation of Atrial Septal Defect Using Real-time Three-dimensional Echocardiography:Comparison with Surgical Findings 被引量:2
16
作者 Saumu Tobbi Mweri 邓又斌 +12 位作者 程佩萱 林汉华 王宏伟 Ommari Baaliy Mkangara 夏治 胡秀芬 毕小军 伍玉晗 Mustaafa Bapumiia 申屠伟慧 刘蓉 刘娅妮 朱美华 《Journal of Huazhong University of Science and Technology(Medical Sciences)》 SCIE CAS 2009年第2期257-259,共3页
The present study evaluated the application of three dimensional echocardigraphy (3DE) in the diagnosis of atrial septal defect (ASD) and the measurement of its size by 3DE and compared the size with surgical find... The present study evaluated the application of three dimensional echocardigraphy (3DE) in the diagnosis of atrial septal defect (ASD) and the measurement of its size by 3DE and compared the size with surgical findings. Two-dimensional and real-time three dimensional echocardiography (RT3DE) was performed in 26 patients with atrial septal defect, and the echocardiographic data were compared with the surgical findings. Significant correlation was found between defect diameter by RT3DE and that measured during surgery (r=0.77, P〈0.001). The defect area changed significantly during cardiac cycle. Percentage change in defect size during cardiac cycle ranged from 6%-70%. Our study showed that the size and morphology of atrial septal defect obtained with RT3DE correlate well with surgical findings. Therefore, RT3DE is a feasible and accurate non-invasive imaging tool for assessment of atrial septal size and dynamic changes. 展开更多
关键词 real-time three-dimensional echocardiography atrial septal defect two dimensional echocardiography
下载PDF
Dynamic Characteristic Mechanism of Atrial Septal Defect Using Real-Time Three-Dimensional Echocardiography and Evaluation of Right Ventricular Functions 被引量:7
17
作者 沙仁高娃 张军 +1 位作者 秦川 吕清 《Journal of Huazhong University of Science and Technology(Medical Sciences)》 SCIE CAS 2017年第1期140-147,共8页
The dynamic characteristics of the area of the atrial septal defect(ASD) were evaluated using the technique of real-time three-dimensional echocardiography(RT 3DE), the potential factors responsible for the dynami... The dynamic characteristics of the area of the atrial septal defect(ASD) were evaluated using the technique of real-time three-dimensional echocardiography(RT 3DE), the potential factors responsible for the dynamic characteristics of the area of ASD were observed, and the overall and local volume and functions of the patients with ASD were measured. RT 3DE was performed on the 27 normal controls and 28 patients with ASD. Based on the three-dimensional data workstations, the area of ASD was measured at P wave vertex, R wave vertex, T wave starting point, and T wave terminal point and in the T-P section. The right atrial volume in the same time phase of the cardiac cycle and the motion displacement distance of the tricuspid annulus in the corresponding period were measured. The measured value of the area of ASD was analyzed. The changes in the right atrial volume and the motion displacement distance of the tricuspid annulus in the normal control group and the ASD group were compared. The right ventricular ejection fractions in the normal control group and the ASD group were compared using the RT 3DE long-axis eight-plane(LA 8-plane) method. Real-time three-dimensional volume imaging was performed in the normal control group and ASD group(n=30). The right ventricular inflow tract, outflow tract, cardiac apex muscular trabecula dilatation, end-systolic volume, overall dilatation, end-systolic volume, and appropriate local and overall ejection fractions in both two groups were measured with the four-dimensional right ventricular quantitative analysis method(4D RVQ) and compared. The overall right ventricular volume and the ejection fraction measured by the LA 8-plane method and 4D RVQ were subjected to a related analysis. Dynamic changes occurred to the area of ASD in the cardiac cycle. The rules for dynamic changes in the area of ASD and the rules for changes in the right atrial volume in the cardiac cycle were consistent. The maximum value of the changes in the right atrial volume occurred in the end-systolic period when the peak of the curve appeared. The minimum value of the changes occurred in the end-systolic period and was located at the lowest point of the volume variation curve. The area variation curve for ASD and the motion variation curve for the tricuspid annulus in the cardiac cycle were the same. The displacement of the tricuspid annulus exhibited directionality. The measured values of the area of ASD at P wave vertex, R wave vertex, T wave starting point, T wave terminal point and in the T-P section were properly correlated with the right atrial volume(P〈0.001). The area of ASD and the motion displacement distance of the tricuspid annulus were negatively correlated(P〈0.05). The right atrial volumes in the ASD group in the cardiac cycle in various time phases increased significantly as compared with those in the normal control group(P=0.0001). The motion displacement distance of the tricuspid annulus decreased significantly in the ASD group as compared with that in the normal control group(P=0.043). The right ventricular ejection fraction in the ASD group was lower than that in the normal control group(P=0.032). The ejection fraction of the cardiac apex trabecula of the ASD patients was significantly lower than the ejection fractions of the right ventricular outflow tract and inflow tract and overall ejection fraction. The difference was statistically significant(P=0.005). The right ventricular local and overall dilatation and end-systolic volumes in the ASD group increased significantly as compared with those in the normal control group(P=0.031). The a RVEF and the overall ejection fraction decreased in the ASD group as compared with those in the normal control group(P=0.0005). The dynamic changes in the area of ASD and the motion curves for the right atrial volume and tricuspid annulus have the same dynamic characteristics. RT 3DE can be used to accurately evaluate the local and overall volume and functions of the right ventricle. The local and overall volume loads of the right ventricle in the ASD patients increase significantly as compared with those of the normal people. The right ventricular cardiac apex and the overall systolic function decrease. 展开更多
关键词 ultrasonic cardiography real-time three-dimension atrial septal defect tricuspid annulus right atrium
下载PDF
Clinical Value of Stereoscopic Three-dimensional Echocardiography in Assessment of Atrial Septal Defects: Feasibility and Efficiency 被引量:1
18
作者 王静 王新房 +3 位作者 谢明星 贺林 吕清 王蕾 《Journal of Huazhong University of Science and Technology(Medical Sciences)》 SCIE CAS 2009年第6期791-794,共4页
Stereoscopic three-dimensional echocardiography(S-3DE) is a novel displaying technol-ogy based on real-time 3-dimensional echocardiography (RT-3DE). Our study was to evaluate the feasibility and efficiency of S-3D... Stereoscopic three-dimensional echocardiography(S-3DE) is a novel displaying technol-ogy based on real-time 3-dimensional echocardiography (RT-3DE). Our study was to evaluate the feasibility and efficiency of S-3DE in the diagnosis of atrial septal defect (ASD) and its use in the guidance for transcatheter ASD occlusion. Twelve patients with secundum ASD underwent RT-3DE examination and 9 of the 12 were subjected to transcatheter closure of ASD. Stereoscopic vision was generated with a high-performance volume renderer with red-green stereoscopic glasses. S-3DE was compared with standard RT-3D display for the assessment of the shape, size, and the surrounding tis-sues of ASD and for the guidance of ASD occlusion. The appearance rate of coronary sinus and the mean formation time of the IVC, SVC were compared. Our results showed that S-3DE could measure the diameter of ASD accurately and there was no significant difference in the measurements between S-3DE and standard 3D display (2.89±0.73 cm vs 2.85±0.72 cm, P〉0.05; r=0.96, P〈0.05). The appearance of coronary sinus for S-3DE was higher as compared with the standard 3D display (93.3% vs 100%). The mean time of the IVC, SVC for S-3DE monitor was slightly shorter than that of the standard 3D display (11.0±3.8 s vs 10.3±3.6 s, P〉0.05). The mean completion time of interven-tional procedure was shortened with S-3DE display as compared with standard 3D display (17.3±3.1 min vs 23.0±3.9 min, P〈0.05). Stereoscopic three-dimensional echocardiography could improve the visualization of three-dimensional echocardiography, facilitate the identification of the adjacent structures, decrease the time required for interventional manipulation. It may be a feasible, safe, and efficient tool for guiding transcatheter septal occlusion or the surgical interventions. 展开更多
关键词 ECHOCARDIOGRAPHY stereoscopic vision real time THREE-DIMENSION atrial septal defect OCCLUSION
下载PDF
Cryoballoon pulmonary vein isolation and left atrial appendage occlusion prior to atrial septal defect closure: A case report 被引量:1
19
作者 Yu-Cheng Wu Mei-Xiang Wang +2 位作者 Ge-Cai Chen Zhong-Bao Ruan Qing-Qing Zhang 《World Journal of Clinical Cases》 SCIE 2022年第12期3872-3878,共7页
BACKGROUND In patients who suffer from both atrial fibrillation(AF)and atrial septal defect(ASD),cryoballoon pulmonary vein isolation(PVI),sequential left atrial appendage(LAA)occlusion and ASD closure could be a stra... BACKGROUND In patients who suffer from both atrial fibrillation(AF)and atrial septal defect(ASD),cryoballoon pulmonary vein isolation(PVI),sequential left atrial appendage(LAA)occlusion and ASD closure could be a strategy for effective prevention of stroke and right heart failure.CASE SUMMARY A 65-year-old man was admitted to our institution due to recurrent episodes of palpitations and shortness of breath for 2 years,which had been worsening over the last 48 h.He had a history of AF,ASD,coronary heart disease with stent implantation and diabetes.Physical and laboratory examinations showed no abnormalities.The score of CHA2DS2VASc was 3,and HAS-BLED was 1.Echocardiography revealed a 25-mm secundum ASD.Pulmonary vein(PV)and LAA anatomy were assessed by cardiac computed tomography.PV mapping with 10-pole Lasso catheter was performed following ablation of all four PVs with complete PVI.Following the cryoballoon PVI,the patient underwent LAA occlusion under transesophageal echocardiographic monitoring.Lastly,a 34-mm JIYI ASD occlude device was implanted.A follow-up transesophageal echocardiography at 3 mo showed proper position of both devices and neither thrombi nor leakage was found.CONCLUSION Sequential cryoballoon PVI and LAA occlusion prior to ASD closure can be performed safely in AF patients with ASD. 展开更多
关键词 Atrial fibrillation Atrial septal defect CRYOBALLOON Pulmonary vein isolation Left atrial appendage occlusion Case report
下载PDF
Misdiagnosis of unroofed coronary sinus syndrome as an ostium primum atrial septal defect by echocardiography:A case report 被引量:1
20
作者 Jin-Ling Chen Cai-Gui Yu +1 位作者 Dai-Jiao Wang Hong-Bin Chen 《World Journal of Clinical Cases》 SCIE 2022年第5期1592-1597,共6页
BACKGROUND Unroofed coronary sinus syndrome(UCSS)is a rare congenital heart disease,which has variable morphologic features and is strongly associated with persistent left superior vena cava(PLSVC).However,it is often... BACKGROUND Unroofed coronary sinus syndrome(UCSS)is a rare congenital heart disease,which has variable morphologic features and is strongly associated with persistent left superior vena cava(PLSVC).However,it is often difficult to visualize the left-to-right shunt pathway through the CS by transthoracic echocardiography(TTE).CASE SUMMARY A 37-year-old female was admitted to the hepatological surgery department of a hospital with complaint of subxiphoid pain that had started 1 wk prior.Physical examination revealed a grade 3/6 systolic murmur at the left margin of the sternum,between the 2nd and 3rd intercostal cartilage.The patient underwent echocardiography and was diagnosed with ostium primum atrial septal defect(ASD);thus,she was subsequently transferred to the cardiovascular surgery department.A second TTE evaluation before surgery showed type IV UCSS with secundum ASD.Right-heart contrast echocardiography(RHCE)showed that the right atrium and right ventricle were immediately filled with microbubbles,but no microbubble was observed in the CS.Meanwhile,negative filling was observed at the right atrium orifice of the CS and right atrium side of the secundum atrial septal.RHCE identified UCSS combined with secundum ASD but without PLSVC in this patient.CONCLUSION This rare case of UCSS highlights the value of TTE combined with RHCE in confirming UCSS with ASD or PLSVC. 展开更多
关键词 Congenital heart disease Coronary sinus Atrial septal defect Persistent left superior vena cava ECHOCARDIOGRAPHY Right heart contrast echocardiography Case report
下载PDF
上一页 1 2 179 下一页 到第
使用帮助 返回顶部