Based on the plant model of 600-MW PWR,the molten core-concrete interactions(MCCI) under different models are studied.Station blackout (SBO) with steam-driven auxiliary feed water pump failure is selected as the case ...Based on the plant model of 600-MW PWR,the molten core-concrete interactions(MCCI) under different models are studied.Station blackout (SBO) with steam-driven auxiliary feed water pump failure is selected as the case for the model comparisons analysis.The result shows that thermal resistance model between debris and concrete has much influence on the consequence of MCCI.The concrete erosion rate calculated with gas film model is much higher than that of slag film model.Some other model comparisons such as the chemical reaction heat and the configuration molten pool are also discussed.展开更多
文摘Based on the plant model of 600-MW PWR,the molten core-concrete interactions(MCCI) under different models are studied.Station blackout (SBO) with steam-driven auxiliary feed water pump failure is selected as the case for the model comparisons analysis.The result shows that thermal resistance model between debris and concrete has much influence on the consequence of MCCI.The concrete erosion rate calculated with gas film model is much higher than that of slag film model.Some other model comparisons such as the chemical reaction heat and the configuration molten pool are also discussed.