The background and scientific objectives of the Mars Climate Station(MCS)for Tianwen-1 are introduced,accompanied by a comparative review of the status of related meteorological observation missions and of advanced se...The background and scientific objectives of the Mars Climate Station(MCS)for Tianwen-1 are introduced,accompanied by a comparative review of the status of related meteorological observation missions and of advanced sensing technologies.As one of the China Tianwen-1 Mission’s principal scientific payloads,the MCS contains four measurement sensors and one electronic processing unit that are specially designed to measure local temperature,pressure,wind,and sound on the Martian surface.The MCS’s measurement principles,technical schemes,ground calibration techniques,and adaptability evaluation to the Mars surface environment of MCS are introduced in details.The conclusion presents measurement performance specifications of the MCS,based on ground test results,that will provide guidance to future research based on data from the Tianwen-1 and later Mars missions.展开更多
In this paper,the main purpose is to analyze and research the characteristics of the geoelectric field observed data with a long time span and large amplitude abnormal change,at the Lhasa geomagnetic station( hereafte...In this paper,the main purpose is to analyze and research the characteristics of the geoelectric field observed data with a long time span and large amplitude abnormal change,at the Lhasa geomagnetic station( hereafter referred to as "Lhasa station "),before and after the Nepal M_S8. 1 strong earthquake,which occurred on April 25,2015. Based on the observation conditions,the observation system,and the observed data of Lhasa station preliminary discussed,the main characteristics of the abnormal change and evolution process are analyzed and studied,using the following two methods; the "synthesis energy accumulation"and the "power as MSA spectrum"analysis,from the two aspects of the"Time Domain"and"Frequency Domain. "The results show that the abnormal change of the geo-electric field observation of Lhasa station experienced a development stage following the process of "trend change- disturbance change- earthquake period-recovery period",and an evolution process of "low frequency change- high frequency change- smooth change- high frequency change ",before and after the Nepal M_S8. 1strong earthquake. Comprehensive analysis shows that the variation characteristics and evolution process of the geo-electric field at Lhasa station are basically consistent with the results of the relevant mechanism and phenomenon research. So far,this is valuable information with certain objectivity,which is typical and representative to reflect the whole process of the gestation, occurrence and complete development of such strongearthquakes.展开更多
In order to specify the overvoltage and insulation level of equipments in ±1 100 kV UHVDC converter stations,the arrester configuration scheme and some basic parameters for ±1 100 kV Zhundong converter stati...In order to specify the overvoltage and insulation level of equipments in ±1 100 kV UHVDC converter stations,the arrester configuration scheme and some basic parameters for ±1 100 kV Zhundong converter station are proposed.Overvoltage of equipments in AC system,valve hall,DC busbar,and neutral busbar are also calculated in accordance with the fundamental principles of arrester configuration for UHV converter stations and the existing experiences in insulation coordination of ±800 kV UHVDC converter stations.The work is done also for specifing insulation levels for ±1 100 kV UHVDC converter stations of the ±1 100 kV UHVDC power transmission project from Zhundong to Sichuan in China.Thus,the recommended insulation margins that determine the insulation levels of converter station equipments are proposed: the insulation margins for thyristor valves are 10%/10%/15% for switching impulse/ lightning impulse/ steer front impulse; the insulation levels of lighting and swtiching impulses are recommended as 2 600 kV and 2 150 kV respectively for 1 100 kV DC buses,and as 2 250 kV and 2 100 kV respectively for equipments at the valve side of high-voltage Y/Y converter transformers.展开更多
直流输电系统的内过电压主要通过金属氧化物避雷器(metal oxide arrester,MOA)加以限制,避雷器在内过电压下的保护特性对确定设备的操作冲击绝缘水平具有重要意义。根据±1 100 k V主回路接线、避雷器配置、交直流系统参数等,建立...直流输电系统的内过电压主要通过金属氧化物避雷器(metal oxide arrester,MOA)加以限制,避雷器在内过电压下的保护特性对确定设备的操作冲击绝缘水平具有重要意义。根据±1 100 k V主回路接线、避雷器配置、交直流系统参数等,建立了±1 100 k V系统内过电压计算模型。对避雷器电压和电流波形进行仿真,对避雷器电流的波头时间进行统计。统计结果为:内过电压下通过避雷器电流的波头时间均不小于100μs,大于标准操作冲击电流的波头时间30μs,需要对较缓电流波头下避雷器的保护特性进行研究。为加以对比,对波形为316/814μs、30/60μs、8/20μs和1/4μs电流下的避雷器伏秒特性和伏安特性进行了试验研究。结果表明,同样电流下,1/4μs的伏安特性曲线高于8/20μs、30/60μs和316/814μs的曲线,而后三者的伏安特性曲线则区别不大;8/20μs、30/60μs和316/814μs的伏安特性相比,在0.1~1 k A电流范围内,30/60μs的伏安特性曲线比8/20μs和316/814μs的伏安特性曲线稍高。由于避雷器操作冲击电流的波头时间均不小于100μs,内过电压下避雷器取30/60μs电流波形下的伏安曲线是合适的,且是稍微偏严的。最后试验测试了避雷器电阻片在30/60μs操作冲击电流下的伏安特性。展开更多
基金supported by funding from the China State Administration of Science Technology and Industry for National Defense.
文摘The background and scientific objectives of the Mars Climate Station(MCS)for Tianwen-1 are introduced,accompanied by a comparative review of the status of related meteorological observation missions and of advanced sensing technologies.As one of the China Tianwen-1 Mission’s principal scientific payloads,the MCS contains four measurement sensors and one electronic processing unit that are specially designed to measure local temperature,pressure,wind,and sound on the Martian surface.The MCS’s measurement principles,technical schemes,ground calibration techniques,and adaptability evaluation to the Mars surface environment of MCS are introduced in details.The conclusion presents measurement performance specifications of the MCS,based on ground test results,that will provide guidance to future research based on data from the Tianwen-1 and later Mars missions.
基金funded by the key projects off undamental Research projects in the Institute of Earthquake Science,CEA(Grant No:2013IES0101&2014IES0101)
文摘In this paper,the main purpose is to analyze and research the characteristics of the geoelectric field observed data with a long time span and large amplitude abnormal change,at the Lhasa geomagnetic station( hereafter referred to as "Lhasa station "),before and after the Nepal M_S8. 1 strong earthquake,which occurred on April 25,2015. Based on the observation conditions,the observation system,and the observed data of Lhasa station preliminary discussed,the main characteristics of the abnormal change and evolution process are analyzed and studied,using the following two methods; the "synthesis energy accumulation"and the "power as MSA spectrum"analysis,from the two aspects of the"Time Domain"and"Frequency Domain. "The results show that the abnormal change of the geo-electric field observation of Lhasa station experienced a development stage following the process of "trend change- disturbance change- earthquake period-recovery period",and an evolution process of "low frequency change- high frequency change- smooth change- high frequency change ",before and after the Nepal M_S8. 1strong earthquake. Comprehensive analysis shows that the variation characteristics and evolution process of the geo-electric field at Lhasa station are basically consistent with the results of the relevant mechanism and phenomenon research. So far,this is valuable information with certain objectivity,which is typical and representative to reflect the whole process of the gestation, occurrence and complete development of such strongearthquakes.
基金supported by National Basic Research Program of China(973 Program)(2011CB209405)
文摘In order to specify the overvoltage and insulation level of equipments in ±1 100 kV UHVDC converter stations,the arrester configuration scheme and some basic parameters for ±1 100 kV Zhundong converter station are proposed.Overvoltage of equipments in AC system,valve hall,DC busbar,and neutral busbar are also calculated in accordance with the fundamental principles of arrester configuration for UHV converter stations and the existing experiences in insulation coordination of ±800 kV UHVDC converter stations.The work is done also for specifing insulation levels for ±1 100 kV UHVDC converter stations of the ±1 100 kV UHVDC power transmission project from Zhundong to Sichuan in China.Thus,the recommended insulation margins that determine the insulation levels of converter station equipments are proposed: the insulation margins for thyristor valves are 10%/10%/15% for switching impulse/ lightning impulse/ steer front impulse; the insulation levels of lighting and swtiching impulses are recommended as 2 600 kV and 2 150 kV respectively for 1 100 kV DC buses,and as 2 250 kV and 2 100 kV respectively for equipments at the valve side of high-voltage Y/Y converter transformers.
文摘直流输电系统的内过电压主要通过金属氧化物避雷器(metal oxide arrester,MOA)加以限制,避雷器在内过电压下的保护特性对确定设备的操作冲击绝缘水平具有重要意义。根据±1 100 k V主回路接线、避雷器配置、交直流系统参数等,建立了±1 100 k V系统内过电压计算模型。对避雷器电压和电流波形进行仿真,对避雷器电流的波头时间进行统计。统计结果为:内过电压下通过避雷器电流的波头时间均不小于100μs,大于标准操作冲击电流的波头时间30μs,需要对较缓电流波头下避雷器的保护特性进行研究。为加以对比,对波形为316/814μs、30/60μs、8/20μs和1/4μs电流下的避雷器伏秒特性和伏安特性进行了试验研究。结果表明,同样电流下,1/4μs的伏安特性曲线高于8/20μs、30/60μs和316/814μs的曲线,而后三者的伏安特性曲线则区别不大;8/20μs、30/60μs和316/814μs的伏安特性相比,在0.1~1 k A电流范围内,30/60μs的伏安特性曲线比8/20μs和316/814μs的伏安特性曲线稍高。由于避雷器操作冲击电流的波头时间均不小于100μs,内过电压下避雷器取30/60μs电流波形下的伏安曲线是合适的,且是稍微偏严的。最后试验测试了避雷器电阻片在30/60μs操作冲击电流下的伏安特性。