期刊文献+
共找到45,603篇文章
< 1 2 250 >
每页显示 20 50 100
Increased dependence on nitrogen-fixation of a native legume in competition with an invasive plant 被引量:1
1
作者 Meixu Han Haiyang Zhang +12 位作者 Mingchao Liu Jinqi Tang Xiaocheng Guo Weizheng Ren Yong Zhao Qingpei Yang Binglin Guo Qinwen Han Yulong Feng Zhipei Feng Honghui Wu Xitian Yang Deliang Kong 《Plant Diversity》 SCIE CAS CSCD 2024年第4期510-518,共9页
Suppression of roots and/or their symbiotic microorganisms,such as mycorrhizal fungi and rhizobia,is an effective way for alien plants to outcompete native plants.However,little is known about how invasive and native ... Suppression of roots and/or their symbiotic microorganisms,such as mycorrhizal fungi and rhizobia,is an effective way for alien plants to outcompete native plants.However,little is known about how invasive and native plants interact with the quantity and activity of nutrient-acquisition agents.Here a pot experiment was conducted with monoculture and mixed plantings of an invasive plant,Xanthium strumarium,and a common native legume,Glycine max.We measured traits related to root and nodule quantity and activity and mycorrhizal colonization.Compared to the monoculture,fine root quantity(biomass,surface area)and activity(root nitrogen(N)concentration,acid phosphatase activity)of G.max decreased in mixed plantings;nodule quantity(biomass)decreased by 45%,while nodule activity in Nfixing via rhizobium increased by 106%;mycorrhizal colonization was unaffected.Contribution of N fixation to leaf N content in G.max increased in the mixed plantings,and this increase was attributed to a decrease in the rhizosphere soil N of G.max in the mixed plantings.Increased root quantity and activity,along with a higher mycorrhizal association was observed in X.strumarium in the mixed compared to monoculture.Together,the invasive plant did not directly scavenge N from nodule-fixed N,but rather depleted the rhizosphere soil N of the legume,thereby stimulating the activity of N-fixation and increasing the dependence of the native legume on this N source.The quantity-activity framework holds promise for future studies on how native legumes respond to alien plant invasions. 展开更多
关键词 Mycorrhizal strategy Nitrogen depletion Plant invasion Root nutrient acquisition strategy Symbiotic nitrogen fixation
下载PDF
Intermittent sliding-lock-knot suture for limbal conjunctival autograft fixation in pterygium surgery:a technique note
2
作者 Ling Zhang Run-Hua Lyu +3 位作者 Jing-Ru Wang Wen-Jian Shi Feng Zheng Ying-Ying Gao 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2024年第5期838-844,共7页
AIM:To report a technique used with intermittent slidinglock-knot(ISLK)fixation for limbal conjunctival autografts in pterygium surgery and compared with those of routine intermittent(RI)fixation.METHODS:Consecutive p... AIM:To report a technique used with intermittent slidinglock-knot(ISLK)fixation for limbal conjunctival autografts in pterygium surgery and compared with those of routine intermittent(RI)fixation.METHODS:Consecutive patients with primary pterygium who had undergone pterygium excision combined with limbal conjunctival autograft transplantation between March 2021 and March 2022 at our institute were retrospectively analyzed.Primary outcome measures were mean duration of surgery and suture removal,degree of conjunctival hyperemia on postoperative day 1,pain score at suture removal,postoperative symptoms at 6mo,including conjunctival hyperemia,foreign body sensation,and graft stability.RESULTS:Ninety-eight patients underwent monocular surgery and were divided into ISLK(51 eyes)and RI(47 eyes)groups according to the type of conjunctiva autograft fixation method planned.There was no significant difference in mean duration of surgery between the two groups(18.59±2.39min vs 18.15±2.20min,P=0.417);however,compared to the RI group,shorter suture removal times were observed in the ISLK group[0.58min(0.42-0.87)vs 3.00min(2.21-4.15),P<0.001].The degree of conjunctival hyperemia on postoperative day 1 was milder in the ISLK group(P<0.001).Pain scores at suture removal were lower in the ISLK group than in RI group[1(0-3)vs 2(1-4),P<0.001].Postoperative symptoms at 6mo were comparable between the groups(P=0.487),with no recurrence.CONCLUSION:ISLK is an innovative method for limbal conjunctival autograft fixation after pterygium excision.Compared to RI fixation,ISLK facilitates suture removal and reduces discomfort,with comparable surgery duration and less conjunctival hyperemia. 展开更多
关键词 intermittent sliding-lock-knot fixation pterygium suture removal
下载PDF
Plasma nitrogen fixation system with dual-loop enhancement for improved energy efficiency and its efficacy for lettuce cultivation
3
作者 韩泽阳 张梦雪 +8 位作者 张頔 何欣 井天军 葛知轩 李玉鸽 朱童 任云鸿 仲崇山 季方 《Plasma Science and Technology》 SCIE EI CAS CSCD 2024年第1期82-92,共11页
Plasma nitrogen fixation(PNF)has been emerging as a promising technology for greenhouse gasfree and renewable energy-based agriculture.Yet,most PNF studies seldom address practical application-specific issues.In this ... Plasma nitrogen fixation(PNF)has been emerging as a promising technology for greenhouse gasfree and renewable energy-based agriculture.Yet,most PNF studies seldom address practical application-specific issues.In this work,we present the development of a compact and automatic PNF system for on-site agricultural applications.The system utilized a gliding-arc discharge as the plasma source and employed a dual-loop design to generate NO_(x)from air and water under atmospheric conditions.Experimental results showed that the system with a dualloop design performs well in terms of energy costs and production rates.Optimal operational parameters for the system were determined through experimentation,resulting in an energy cost of 13.9 MJ mol^(-1)and an energy efficiency of 16 g kWh^(-1)for NO_(3)^(-)production,respectively.Moreover,the concentration of exhausted NO_(x)was below the emission standards.Soilless lettuce cultivation experiments demonstrated that NO_(x)^(-)produced by the PNF system could serve as liquid nitrate nitrogen fertilizer.Overall,our work demonstrates the potential of the developed PNF system for on-site application in the production of green-leaf vegetables. 展开更多
关键词 plasma nitrogen fixation gliding arc soilless cultivation LETTUCE
下载PDF
Microfluidic-oriented synthesis of enriched iridium nanodots/carbon architecture for robust electrocatalytic nitrogen fixation
4
作者 Hengyuan Liu Xingjiang Wu +2 位作者 Yuhao Geng Xin Li Jianhong Xu 《Green Energy & Environment》 SCIE EI CAS CSCD 2024年第3期544-555,共12页
Electrocatalytic nitrogen reduction reaction(NRR)is considered as a promising candidate to achieve ammonia synthesis because of clean electric energy,moderate reaction condition,safe operating process and harmless by-... Electrocatalytic nitrogen reduction reaction(NRR)is considered as a promising candidate to achieve ammonia synthesis because of clean electric energy,moderate reaction condition,safe operating process and harmless by-products.However,the chemical inertness of nitrogen and poor activated capacity on catalyst surface usually produce low ammonia yield and faradic efficiency.Herein,the microfluidic technology is proposed to efficiently fabricate enriched iridium nanodots/carbon architecture.Owing to in-situ co-precipitation reaction and microfluidic manipulation,the iridium nanodots/carbon nanomaterials possess small average size,uniform dispersion,high conductivity and abundant active sites,producing good proton activation and rapid electrons transmission and moderate adsorption/desorption capacity.As a result,the as-prepared iridium nanodots/carbon nanomaterials realize large ammonia yield of 28.73 μg h^(-1) cm^(-2) and faradic efficiency of 9.14%in KOH solution.Moreover,the high ammonia yield of 11.21 μg h^(-1) cm^(-2) and faradic efficiency of 24.30%are also achieved in H_(2)SO_(4) solution.The microfluidic method provides a reference for large-scale fabrication of nano-sized catalyst materials,which may accelerate the progress of electrocatalytic NRR in industrialization field. 展开更多
关键词 Iridium nanodots CARBON Microfluidic technology Efficient synthesis Electrocatalytic nitrogen fixation
下载PDF
Sutured scleral fixation of existing subluxated/dislocated acrylic one-piece intraocular lenses
5
作者 Wei-Yu Huang Yung-Jen Chen 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2024年第4期665-669,共5页
AIM:To evaluate the visual and refractive outcomes in cases after sutured scleral fixation of existing subluxated or dislocated acrylic one-piece intraocular lenses(IOLs).METHODS:This study retrospectively enrolled a ... AIM:To evaluate the visual and refractive outcomes in cases after sutured scleral fixation of existing subluxated or dislocated acrylic one-piece intraocular lenses(IOLs).METHODS:This study retrospectively enrolled a consecutive series of patients who underwent a surgery of sutured existing subluxated or dislocated IOLs from October 2018 to June 2020.All patients underwent comprehensive preoperative and postoperative ophthalmologic examination,and data were collected including age,sex,surgical indications,best-corrected visual acuity,refractive error,intraocular pressure.Presence of intraoperative and postoperative surgical complications was documented.RESULTS:A total of 20 consecutive cases were enrolled for analysis with mean final follow-up period 9.8±5.3mo.Visual acuity improved from a mean of 0.35(0.46±0.32 logMAR)preoperatively to 0.61(0.21±0.18 logMAR)at the 3-month follow-up(P=0.002).The mean amount of preoperative keratometric astigmatism and total postoperative refractive astigmatism was-1.24±0.80 diopters(D)and-1.42±0.97 D,respectively.There was no statistically significant difference between preoperative and postoperative astigmatism(P=0.156).The mean IOL-induced astigmatism was-0.23±0.53 D.The mean spherical equivalent at the 3-month follow-up was-0.1±0.94 D.No major complications were noted during the follow-up period.CONCLUSION:Surgical techniques using sutured scleral fixation of existing subluxated or dislocated acrylic one-piece IOLs result in favorable visual and refractive outcomes without major complications. 展开更多
关键词 intraocular lens dislocation intraocular lens subluxation lens dislocation lens subluxation scleral fixation
下载PDF
In vitro performance of a biodegradable zinc alloy adjustable-loop cortical suspension fixation for anterior cruciate ligament reconstruction
6
作者 Ting Wang Zhangzhi Shi +7 位作者 Hongyong Zhong Xiangmin Li Jinling Sun Wei Yin Xiaojing Ji Qiang Wang Anqi Zhao Luning Wang 《International Journal of Minerals,Metallurgy and Materials》 SCIE EI CAS CSCD 2024年第5期887-898,共12页
Anterior cruciate ligament(ACL)injuries of the knee are one of the most common and serious athletic injuries.The widely used cortical suspension fixation buttons for ligament reconstruction are permanent implants,part... Anterior cruciate ligament(ACL)injuries of the knee are one of the most common and serious athletic injuries.The widely used cortical suspension fixation buttons for ligament reconstruction are permanent implants,particularly those made from conventional steel or titanium alloys.In this study,a biodegradable Zn-0.45Mn-0.2Mg(ZMM42)alloy with the yield strength of 300.4 MPa and tensile strength of 329.8 MPa was prepared through hot extrusion.The use of zinc alloys in the preparation of cortical suspension fixation buttons was proposed for the first time.After 35 d of immersion in simulated body fluids,the ZMM42 alloy fixation buttons were degraded at a rate of 44μm/a,and the fixation strength was retained(379.55 N)in the traction loops.Simultaneously,the ZMM42 alloy fixation buttons exhibited an increase in MC3T3-E1 cell viability and high antibacterial activity against Escherichia coli and Staphylococcus aureus.These results reveal the potential of biodegradable zinc alloys for use as ligament reconstruction materials and for developing diverse zinc alloy cortical suspension fixation devices. 展开更多
关键词 anterior cruciate ligament reconstruction zinc alloy fixation buttons mechanical property corrosion behavior BIOCOMPATIBILITY
下载PDF
Health economics for intra-capsular hip fractures undertaking fixation
7
作者 Anatole Wiik Thomas Ashdown Ian Holloway 《World Journal of Orthopedics》 2024年第1期30-38,共9页
BACKGROUND Hip fracture is a common musculoskeletal injury in the elderly requiring surgery worldwide.The operative mainstay of intra-capsular hip fractures is arthroplasty with a smaller proportion for fixation.AIM T... BACKGROUND Hip fracture is a common musculoskeletal injury in the elderly requiring surgery worldwide.The operative mainstay of intra-capsular hip fractures is arthroplasty with a smaller proportion for fixation.AIM To determine the most beneficial method of fixation for patients with intracapsular hip fractures.METHODS A registered audit from 2012-2018 was conducted on all intra-capsular hip fractures treated with 2 commonly used fixation methods.Patient notes,electronic records and clinical codes for cost benefit were evaluated.A validated quality of life measure was collected at least 1 year after surgery.RESULTS A total of 83 patients were identified with intra-capsular fractures undergoing fixation during the retrospective period.There were 47 cannulated cancellous screw and 36 sliding hip screw fixations with the case mix comparable for age,gender,co-morbidities and fracture configuration.There was no significant difference in blood loss,tip apex distance,radiation exposure,length of stay,radiological union time,collapse,avascular necrosis or re-operation between fixation methods.Logistic regression analysis demonstrated displaced intracapsular hip fractures correlated significantly with an undesirable outcome conferring a relative odds ratio of 7.25.There were 9(19%)and 4(11%)patients respectively,who required re-operation.There was no significant difference in health resource group tariff and implant cost with comparable EQ-5D and visual CONCLUSION No significant advantage was identified with differing fixation type,but irrespective there were a high number of patients requiring re-operation.This was predicted by initial fracture displacement and patient age.Arthroplasty may need to be carefully considered for health economics and patient benefit. 展开更多
关键词 Hip fracture fixation Patient reported outcome measure COST
下载PDF
Arthroscopic M-shaped suture fixation for tibia avulsion fracture of posterior cruciate ligament:A modified technique and case series
8
作者 Xiao-Hui Zhang Jian Yu +3 位作者 Meng-Yao Zhao Jin-Hui Cao Bing Wu Dan-Feng Xu 《World Journal of Orthopedics》 2024年第7期642-649,共8页
BACKGROUND Tibial avulsion fractures of the posterior cruciate ligament(PCL)are challenging to treat and compromise knee stability and function.Traditional open surgery often requires extensive soft tissue dissection,... BACKGROUND Tibial avulsion fractures of the posterior cruciate ligament(PCL)are challenging to treat and compromise knee stability and function.Traditional open surgery often requires extensive soft tissue dissection,which may increase the risk of morbidity.In response to these concerns,arthroscopic techniques have been evolving.The aim of this study was to introduce a modified arthroscopic tech-nique utilizing an M-shaped suture fixation method for the treatment of tibial avulsion fractures of the PCL and to evaluate its outcomes through a case series.AIM To evaluate the effects of arthroscopic M-shaped suture fixation on treating tibia avulsion fractures of the PCL.METHODS We developed a modified arthroscopic M-shaped suture fixation technique for tibia avulsion fractures of the PCL.This case series included 18 patients who underwent the procedure between January 2021 and December 2022.The patients were assessed for range of motion(ROM),Lysholm score and International knee documentation committee(IKDC)score.Postoperative complications were also recorded.RESULTS The patients were followed for a mean of 13.83±2.33 months.All patients showed radiographic union.At the final follow-up,all patients had full ROM and a negative posterior drawer test.The mean Lysholm score significantly improved from 45.28±8.92 preoperatively to 91.83±4.18 at the final follow-up(P<0.001),and the mean IKDC score improved from 41.98±6.06 preoperatively to 90.89±5.32 at the final follow-up(P<0.001).CONCLUSION The modified arthroscopic M-shaped suture fixation technique is a reliable and effective treatment for tibia avulsion fractures of the PCL,with excellent fracture healing and functional recovery. 展开更多
关键词 Posterior cruciate ligament Avulsion fracture ARTHROSCOPIC Case series Suture fixation
下载PDF
Assessment of Nitrogen Fixation, Uptake, and Leaching in Maize/Soybean Intercropping System at Varied Soil Depths and under Phosphorus Application in Chinese Agricultural Settings
9
作者 Bertha Magombo Chunjie Li Benjamin Kolie 《Natural Resources》 2024年第7期173-187,共15页
The study of Nitrogen fixation, uptake, and leaching at different soil depths in the co-cultivation of maize and soybean under phosphorus fertilization is important for sustainable agriculture. This study was conducte... The study of Nitrogen fixation, uptake, and leaching at different soil depths in the co-cultivation of maize and soybean under phosphorus fertilization is important for sustainable agriculture. This study was conducted in Quzhou, Hebei Province, China, with MC812 maize and Jidou12 soybean varieties. Soil samples were taken from each plot to create a composite sample. The results show that nitrogen concentration varies at different depths and is higher in all treatments between 40 and 100 cm. Incorporating intercropping of maize and soybeans into farming practices can lead to more sustainable and environmentally friendly agriculture in China. 展开更多
关键词 Nitrogen Maize/Soybean FERTILIZATION INTERCROPPING Soil fixation
下载PDF
Lateral femoral tunnel preparation and graft fixation for anterior cruciate ligament reconstruction–A discussion
10
作者 Mehak Chandanani Andrea Volpin 《World Journal of Clinical Cases》 SCIE 2024年第17期3277-3280,共4页
This article provides a discussion and commentary around the recent advances in arthroscopic anterior cruciate ligament reconstruction(ACLR),with a focus on the aspects of lateral femoral tunnel preparation and graft ... This article provides a discussion and commentary around the recent advances in arthroscopic anterior cruciate ligament reconstruction(ACLR),with a focus on the aspects of lateral femoral tunnel preparation and graft fixation techniques.The paper explores and comments on a recently published review by Dai et al,titled"Research progress on preparation of lateral femoral tunnel and graft fixation in ACLR",while providing insight into its relevance within the field of ACLR,and recommendations for future research. 展开更多
关键词 Anterior cruciate ligament reconstruction Arthroscopic surgery Lateral femoral tunnel Graft fixation techniques Anterior cruciate ligament tear BIOMECHANICS Knee injuries
下载PDF
Clinical Outcome of Internal Fixation and Fusion in the Treatment of Spinal Fractures by Paraspinal Muscular Space Approach
11
作者 Yafei Zhao Qiushuang Ma +3 位作者 Meng Zhang Shengwang Li Yannan Li Chenguang Tian 《Journal of Clinical and Nursing Research》 2024年第7期10-15,共6页
Objective:To explore the clinical effect of internal fixation and fusion with the paraspinal muscle gap approach in the treatment of spinal fracture patients.Methods:104 spinal fracture patients admitted to Central Ho... Objective:To explore the clinical effect of internal fixation and fusion with the paraspinal muscle gap approach in the treatment of spinal fracture patients.Methods:104 spinal fracture patients admitted to Central Hospital of TCM from October 2022 to April 2024 were selected as the study subjects and were randomly divided into the control group(n=52)and the observation group(n=52)according to the random number table method.The control group was treated with the conventional approach of internal fixation surgery,and the observation group was treated with the paraspinal muscular interspace approach of internal fixation fusion.The two groups’general data,surgical indexes,pain,lumbar spine function,and postoperative complications were observed.Results:The baseline data of the two groups of patients were not statistically significant(all P>0.05)while the intraoperative bleeding,the first postoperative time getting up from bed,and the length of hospital stay of the patients in the observation group were shorter than that of the control group(all P=0.000<0.001),and the duration of the operation was longer than that of the control group(t=2.644,P=0.010<0.05);at 3 months postoperatively,the VAS scores of the patients in the observation group were significantly lower than those in the control group(t=10.768,P=0.000<0.001),and the JOA score was higher than that of the control group(t=6.498,P=0.000<0.001);the total complication rate of patients in the observation group(3/5.77%)was significantly lower than that of the control group(12/23.08%)(χ^(2)=6.310,P=0.012<0.05).Conclusion:In the treatment of spinal fracture patients,compared with the conventional approach to internal fixation surgery,the paraspinal muscular gap approach to internal fixation and fusion treatment is less traumatic,postoperative lumbar spine function recovery is faster,and can reduce the incidence of postoperative complications. 展开更多
关键词 Paraspinal muscular interspace approach fixation and fusion Spinal fracture
下载PDF
Clinical Effectiveness of the Plate Screw Internal Fixation Technique in the Treatment of Patients with Traumatic Fractures of Long Bones in the Lower Extremities
12
作者 Yong Cai 《Proceedings of Anticancer Research》 2024年第3期115-120,共6页
Objective: To investigate the effectiveness of the plate screw internal fixation technique on the clinical outcomes of patients with traumatic fractures of long bones in the lower extremities. Methods: From January 20... Objective: To investigate the effectiveness of the plate screw internal fixation technique on the clinical outcomes of patients with traumatic fractures of long bones in the lower extremities. Methods: From January 2022 to December 2023, 70 patients with traumatic fractures of long bones in the lower extremities were admitted to the hospital and randomly divided into two groups: the control group and the observation group, each consisting of 35 cases. The control group underwent traditional closed interlocking intramedullary nailing, while the observation group received internal fixation with steel plates and screws. Relevant surgical indicators, treatment effectiveness, and postoperative complication rates were compared between the two groups. Results: The observation group exhibited significantly short surgical duration (80.65 ± 5.01 vs. 88.36 ± 5.26 minutes), fracture healing time (13.27 ± 0.32 vs. 15.52 ± 0.48 weeks), and hospitalization days (10.49 ± 1.13 vs. 16.57 ± 1.15 days) compared to the control group (P = 0.000). The effective treatment rate was significantly higher in the observation group (29/82.86%) than in the control group (21/60.00%), with a significant difference observed (χ2 = 4.480, P = 0.034). Additionally, the complication rate in the observation group (2/5.71%) was significantly lower than that in the control group (8/22.86%), with a correlated difference (χ2 = 4.200, P = 0.040). Conclusion: The plate screw internal fixation technique demonstrates significant clinical efficacy in treating traumatic fractures of long bones in the lower extremities. It improves the healing rate, reduces complications, and represents a safe and effective treatment strategy worthy of widespread use and application. 展开更多
关键词 Plate screw internal fixation technique Traumatic fractures Long bones in the lower extremities EFFECTIVENESS
下载PDF
High piezo/photocatalytic efficiency of Ag/Bi_(5)O_(7)I nanocomposite using mechanical and solar energy for N2 fixation and methyl orange degradation 被引量:2
13
作者 Lu Chen Wenqian Zhang +6 位作者 Junfeng Wang Xiaojing Li Yi Li Xin Hu Leihong Zhao Ying Wu Yiming He 《Green Energy & Environment》 SCIE EI CSCD 2023年第1期283-295,共13页
In this work,Ag/Bi_(5)O_(7)I nanocomposite was prepared and firstly applied in piezo/photocatalytic reduction of N2 to NH3 and methyl orange(MO)degradation.Bi_(5)O_(7)I was synthesized via a hydrothermal-calcination m... In this work,Ag/Bi_(5)O_(7)I nanocomposite was prepared and firstly applied in piezo/photocatalytic reduction of N2 to NH3 and methyl orange(MO)degradation.Bi_(5)O_(7)I was synthesized via a hydrothermal-calcination method and shows nanorods morphology.Ag nanoparticles(NPs)were photo deposited on the Bi_(5)O_(7)I nanorods as electron trappers to improve the spatial separation of charge carriers,which was confirmed via XPS,TEM,and electronic chemical analyses.The catalytic test indicates that Bi_(5)O_(7)I presents the piezoelectric-like behavior,while the loading of Ag NPs can strengthen the character.Under ultrasonic vibration,the optimal Ag/Bi_(5)O_(7)I presents high efficiency in MO degradation.The degradation rate is determined to be 0.033 min1,which is 4.7 folds faster than that of Bi_(5)O_(7)I.The Ag/Bi_(5)O_(7)I also presents a high performance in piezocatalytic N2 fixation.The piezocatalytic NH3 generation rate reaches 65.4 μmol L^(-1)g^(-1)h^(-1)with water as a hole scavenger.The addition of methanol can hasten the piezoelectric catalytic reaction.Interestingly,when ultrasonic vibration and light irradiation simultaneously act on the Ag/Bi_(5)O_(7)I catalyst,higher performance in NH3 generation and MO degradation is observed.However,due to the weak adhesion of Ag NPs,some Ag NPs would fall off from the Bi_(5)O_(7)I surface under long-term ultrasonic vibration,which would greatly reduce the piezoelectric catalytic performance.This result indicates that a strong binding force is required when preparing the piezoelectric composite catalyst.The current work provides new insights for the development of highly efficient catalysts that can use multiple energies. 展开更多
关键词 Ag/Bi_(5)O_(7)I Piezocatalysis Photocatalysis N2 fixation MO degradation
下载PDF
Oxygen defect modulating the charge behavior in titanium dioxide for boosting photocatalytic nitrogen fixation performance 被引量:1
14
作者 Mengxia Ji Nianhua Liu +6 位作者 Kai Li Qing Xu Gaopeng Liu Bin Wang Jun Di Huaming Li Jiexiang Xia 《Materials Reports(Energy)》 EI 2023年第4期46-51,共6页
Extremely high-temperature and high-pressure requirement of Haber-Bosch process motivates the search for a sustainable ammonia synthesis approach under mild conditions.Photocatalytic technology is a potential solution... Extremely high-temperature and high-pressure requirement of Haber-Bosch process motivates the search for a sustainable ammonia synthesis approach under mild conditions.Photocatalytic technology is a potential solution to convert N2 to ammonia.However,the poor light absorption and low charge carrier separation efficiency in conventional semiconductors are bottlenecks for the application of this technology.Herein,a facile synthesis of anatase TiO_(2)nanosheets with an abundance of surface oxygen vacancies(TiO_(2)-OV)via the calcination treatment was reported.Photocatalytic experiments of the prepared anatase TiO_(2)samples showed that TiO_(2)-OV nanosheets exhibited remarkably increased ammonia yield for solar-driven N2 fixation in pure water,without adding any sacrificial agents.EPR,XPS,XRD,UV-Vis DRS,TEM,Raman,and PL techniques were employed to systematically explore the possible enhanced mechanism.Studies revealed that the introduced surface oxygen vacancies significantly extended the light absorption capability in the visible region,decreased the adsorption and activation barriers of inert N2,and improved the separation and transfer efficiency of the photogenerated electronhole pairs.Thus,a high rate of ammonia evolution in TiO_(2)-OV was realized.This work offers a promising and sustainable approach for the efficient artificial photosynthesis of ammonia. 展开更多
关键词 Titanium dioxide Oxygen vacancies Artificial photosynthesis Nitrogen fixation Charge separation
下载PDF
Facile preparation of Ag_(2)S/KTa_(0.5)Nb_(0.5)O_(3) heterojunction for enhanced performance in catalytic nitrogen fixation via photocatalysis and piezo-photocatalysis 被引量:2
15
作者 Lu Chen Junfeng Wang +7 位作者 Xiaojing Li Jiayu Zhang Chunran Zhao Xin Hu Hongjun Lin Leihong Zhao Ying Wu Yiming He 《Green Energy & Environment》 SCIE EI CAS CSCD 2023年第6期1630-1643,共14页
In this work, a novel heterojunction composite Ag_(2)S/KTa_(x)Nb_(1-x)O_(3)was designed and synthesized through a combination of hydrothermal and precipitation procedures. The Ta/Nb ratio of the KTa_(x)Nb_(1-x)O_(3)an... In this work, a novel heterojunction composite Ag_(2)S/KTa_(x)Nb_(1-x)O_(3)was designed and synthesized through a combination of hydrothermal and precipitation procedures. The Ta/Nb ratio of the KTa_(x)Nb_(1-x)O_(3)and the Ag_(2)S content were optimized. The best 0.5% Ag_(2)S/KTa_(0.5)Nb_(0.5)O_(3)(KTN) sample presents an enhanced photocatalytic performance in ammonia synthesis than KTN and Ag_(2)S. Under simulated sunlight, the NH_(3)generation rate of 0.5% Ag_(2)S/KTN reaches 2.0 times that of pure KTN. Under visible light, the reaction rate ratio of the two catalysts is 6.0.XRD, XPS, and TEM analysis revealed that Ag2S was intimately decorated on the KTN nanocubes surface, which promoted the electron transfer between the two semiconductors. The band structure investigation indicated that the Ag_(2)S/KTN heterojunction established a type-Ⅱ band alignment with intimate contact, thus realizing the effective transfer and separation of photogenerated carriers. The change in charge separation was considered as the main reason for the enhanced photocatalytic performance. Interestingly, the Ag_(2)S/KTN composite exhibited higher NH3generation performance under the combined action of ultrasonic vibration and simulated sunlight. The enhanced piezo-photocatalytic performance can be ascribed that the piezoelectric effect of KTN improved the bulk separation of charge carriers in KTN. This study not only provides a potential catalyst for photocatalytic nitrogen fixation but also shows new ideas for the design of highly efficient catalysts via semiconductor modification and external field coupling. 展开更多
关键词 Photocatalytic nitrogen fixation Ag_(2)S/KTa_(0.5)Nb_(0.5)O_(3) Type-II heterojunction Piezo-photocatalysis Charge separation
下载PDF
Meta-analysis of the efficacy of volar plate internal fixation versus closed reduction and external fixation in the treatment of adult distal radius fractures
16
作者 CHEN Jian-ge ZHANG Hai-ning +4 位作者 ZHAO Hong-zhou LIU Ming-jun XING Jia-hui WANG Ping WANG Wei-min 《Journal of Hainan Medical University》 CAS 2023年第19期44-56,共13页
Objective:To compare the efficacy of open reduction and volar locking plate internal fixation with closed reduction and external fixation in the treatment of distal radius fractures by using meta analysis.Methods:The ... Objective:To compare the efficacy of open reduction and volar locking plate internal fixation with closed reduction and external fixation in the treatment of distal radius fractures by using meta analysis.Methods:The databases of CNKI,Wanfang,Weipu,Chinese biomedical literature,Pubmed,Embase,and Cochrane Library were retrieved,and the randomized controlled studies that directly compared the efficacy of plate internal fixation and closed reduction external fixation in the treatment of distal radius fractures published publicly from the establishment of the database to April 2023 were collected.The two researchers independently screened the retrieved literature according to the inclusion and exclusion criteria,extracted data,used Cochrane risk bias assessment tool for quality assessment,and used RevMan 5.4 software for meta analysis.Results:A total of 10 randomized controlled trials were included,all of which were in English.There were 1042 patients in total,and 9 of them were rated as low risk.Meta analysis results showed that one year after the treatment of distal radius fracture with volar locking plate internal fixation,DASH score[MD=-5.64,95%CI(-7.21,-4.06),P<0.00001];One year later,PRWE score[MD=-5.90,95%CI(-8.88,-2.92),P=0.001];Palm flexion[MD=5.92,95%CI(1.29,10.55),P=0.01];Pronation[MD=2.48,95%CI(0.59,4.36),P=0.01];Postrotation[MD=4.73,95%CI(2.15,7.31),P=0.0003];Grip strength[MD=0.61,95%CI(0.12,1.10),P=0.02];palmar tilt angle[MD=9.84,95%CI(5.66,14.02),P<0.00001];Radial inclination[MD=4.33,95%CI(2.97,5.69),P<0.00001]was superior to closed reduction plaster or splint external fixation.One year later,the European Five dimensional Health Scale(EQ-5D-5L)score[MD=0.02,95%CI(-0.01,0.05),P=0.27];Back extension[MD=2.22,95%CI(-4.15,8.59),P=0.49];Ulnar deviation[MD=3.49,95%CI(-0.80,7.78),P=0.11];Radial deviation[MD=2.05,95%CI(-2.39,6.50),P=0.37];Ulnar variance[MD=-1.14,95%CI(-3.16,0.88),P=0.27];There was no significant difference in complications[MD=0.77,95%CI(0.54,1.10),P=0.16](P>0.05).Conclusion:Based on the current clinical data,internal fixation with volar locking plate is more conducive to mid-term DASH score and grip strength recovery than closed reduction plaster or splint external fixation,but there is no significant difference in the quality of life and complications of patients.For adult distal radius fractures,surgical indications should be carefully grasped,and non operative treatment should be given priority. 展开更多
关键词 Volar plate Internal fixation Closed reduction External fixation PLASTER SPLINT Distal radius fracture Meta analysis
下载PDF
Flapless one-knot suture:a novel surgical technique for transscleral fixation of C-loop intraocular lenses
17
作者 Qing-Qing Long Bao-Jiang Li 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2023年第5期736-742,共7页
AIM:To describe a novel suture approach for transscleral fixation of C-loop intraocular lenses(IOL)and to compare the surgical outcomes with the four-haptics posterior chamber(PC)-IOL technique.METHODS:We retrospectiv... AIM:To describe a novel suture approach for transscleral fixation of C-loop intraocular lenses(IOL)and to compare the surgical outcomes with the four-haptics posterior chamber(PC)-IOL technique.METHODS:We retrospectively analyzed 16 eyes of 16 patients who underwent transscleral fixation of C-loop PCIOLs using a flapless one-knot suture technique,which were followed up for longer than 17mo.In this technique,the capsulorless IOL was suspended using a single suture for transscleral fixation of four feet.Then we compared its surgical outcomes and complications with the four-haptics PC-IOLs using the Student's t test and Chi-square test.RESULTS:Sixteen patients of 16 eyes with a mean age of 58.3±10.1y(42-76y)who received transscleral C-loop IOL implantation due to trauma,vitrectomy,or cataract surgery with inadequate capsule support showed improved visual acuity.The difference was not significant between two IOLs except the surgery time(P>0.05).The mean operation times of C-loop IOL surgery was 24.1±1.83min and 31.3±4.47min of the four-haptics PC-IOL method(P<0.0001).In the C-loop IOLs group,there was statistical difference between the preoperative and the postoperative UCVA(log MAR,1.20±0.50 vs 0.57±0.32,P=0.0003).There was no statistical difference between the preoperative and the postoperative BCVA(log MAR,0.66±0.46 vs 0.40±0.23,P=0.056).However,there was no statistically significant difference in postoperative UCVA and BCVA between the two IOLs(P>0.05).We did not detect any optic capture,IOL decentration or dislocation,suture exposed,or cystoid macular edema in patients underwent C-loop IOLs surgery.CONCLUSION:The novel flapless one-knot suture technique for transscleral fixation of C-loop IOL is a simple,reliable,and stable technique. 展开更多
关键词 C-loop intraocular lens implantation lens dislocation transscleral fixation four-haptics intraocular lens
下载PDF
Medium-term outcomes of laparoscopic pubocervical fascia reconstruction and sacrospinous ligament fixation with posterior approach for a pelvic organ prolapse:A retrospective study of 124 cases
18
作者 Yunshan Zhu Xiao Zhang +4 位作者 Danxia Chen Guangxiao Li Shanliang Shang Jianqiong Li Jianhua Yang 《Laparoscopic, Endoscopic and Robotic Surgery》 2023年第4期154-159,共6页
Objective:Pelvic organ prolapse(POP)is a common gynecological disease in middle-aged and older women that seriously affects patients'physical health and quality of life,increases the financial burden for patients,... Objective:Pelvic organ prolapse(POP)is a common gynecological disease in middle-aged and older women that seriously affects patients'physical health and quality of life,increases the financial burden for patients,and becomes a major public health concern.The aim of this study was to investigate the medium-term outcomes of laparoscopic pubocervical fascia reconstruction and sacrospinous ligament fixation with a posterior approach for patients with severe POP.Methods:Patients with severe POP quantitation stage III-IV who underwent laparoscopic pubocervical fascia reconstruction and sacrospinous ligament fixation with a posterior approach at the Department of Obstetrics and Gynecology,Sir Run Run Shaw Hospital,Zhejiang University School of Medicine between September 2016 and December 2020 were enrolled in this study.The results and complications were recorded.Data were retrospectively reviewed.Results:In total,124 patients were analyzed.Patients were followed up for 32.2712.90 months.The objective cure rate for patients who underwent hysterectomy was 917%(100/109),with 7(6.4%)patients had anterior vaginal wall prolapse and 2(1.8%)patients had posterior vaginal wall prolapse.The objective cure rate for patients who retained uterus was 66.7%(10/15).All 5 patients with recurrence had uterine prolapse,and 3(20.0%)of them also had anterior vaginal wall prolapse.Conchusions:Laparoscopic pubocervical fascia reconstruction and sacrospinous ligament fixation with the posterior approach is a safe,minimally invasive,and effective method for patients with severe POP.Long-term follow-up is needed to confirm the clinical effects. 展开更多
关键词 Pelvic organ prolapse LAPAROSCOPY Pubocervical fascia reconstruction Sacrospinous ligament fixation
下载PDF
Congenital stapes suprastructure fixation presenting with fluctuating auditory symptoms:A case report
19
作者 Sun Choi Seok Hyun Park +1 位作者 Ji Su Kim Jiwon Chang 《World Journal of Clinical Cases》 SCIE 2023年第1期249-254,共6页
BACKGROUND Stapes ankylosis is a rare cause of conductive hearing loss,and stapes suprastructure fixation is extremely rare with fewer than 30 reported cases.Patients usually visit the clinic with non-progressive cond... BACKGROUND Stapes ankylosis is a rare cause of conductive hearing loss,and stapes suprastructure fixation is extremely rare with fewer than 30 reported cases.Patients usually visit the clinic with non-progressive conductive hearing loss that typically began in the early years of life.CASE SUMMARY Herein,we report a case of a 37-year-old female with an isolated stapedial suprastructure fixation.The patient presented with unusual fluctuating auditory symptoms of tinnitus,ear fullness and mixed hearing loss.Pre-operative temporal bone computed tomography findings and operative findings revealed an isolated stapedial suprastructure fixation with monopod stapes caused by elongated pyramidal eminence.The hearing threshold recovered completely,and fluctuating auditory symptoms disappeared after the surgery.CONCLUSION This is the first report of stapedial suprastructure fixation with fluctuating auditory symptoms.Successful results are expected with surgical treatment. 展开更多
关键词 Isolated stapes ankylosis Stapes suprastructure fixation Elongated pyramidal eminence Stapes monopod Fluctuating auditory symptoms Exploratory tympanotomy Case report
下载PDF
Comparative assessment of nitrogen fixation rate by ^(15)N_(2) tracer assays in the South China Sea
20
作者 Danyang Li Minfang Zheng +5 位作者 Yusheng Qiu Limin Lai Nengwang Chen Hongmei Jing Run Zhang Min Chen 《Acta Oceanologica Sinica》 SCIE CAS CSCD 2023年第1期75-82,共8页
Nitrogen fixation is one of the most important sources of new nitrogen in the ocean and thus profoundly affects the nitrogen and carbon biogeochemical processes.The distribution,controlling factors,and flux of N2 fixa... Nitrogen fixation is one of the most important sources of new nitrogen in the ocean and thus profoundly affects the nitrogen and carbon biogeochemical processes.The distribution,controlling factors,and flux of N2 fixation in the global ocean remain uncertain,partly because of the lack of methodological uniformity.The^(15)N_(2)tracer assay(the original bubble method→the^(15)N_(2)-enriched seawater method→the modified bubble method)is the mainstream method for field measurements of N2 fixation rates(NFRs),among which the original bubble method is the most frequently used.However,accumulating evidence has suggested an underestimation of NFRs when using this method.To improve the availability of previous data,we compared NFRs measured by three^(15)N_(2)tracer assays in the South China Sea.Our results indicate that the relationship between NFRs measured by the original bubble method and the^(15)N_(2)-enriched seawater method varies obviously with area and season,which may be influenced by incubation time,diazotrophic composition,and environmental factors.In comparison,the relationship between NFRs measured by the original bubble method and the modified bubble method is more stable,indicating that the N2 fixation rates based on the original bubble methods may be underestimated by approximately 50%.Based on this result,we revised the flux of N2 fixation in the South China Sea to 40 mmol/(m2·a).Our results improve the availability and comparability of literature NFR data in the South China Sea.The comparison of the^(15)N_(2)tracer assay for NFRs measurements on a larger scale is urgently necessary over the global ocean for a more robust understanding of the role of N2 fixation in the marine nitrogen cycle. 展开更多
关键词 N2 fixation rate South China Sea ^(15)N_(2)tracer assay
下载PDF
上一页 1 2 250 下一页 到第
使用帮助 返回顶部