An Efficient Particle Swarm Optimization Technique for 4-Leg Shunt Active Power Filter
1
作者 V. Parimala S. Chenthur Pandian D. Ganeshkumar 《Circuits and Systems》 2016年第8期1546-1559,共14页
This paper describes the mitigation of harmonics in source and neutral current in three phase four wire system based on 4-leg shunt active power filter under balanced and unbalanced load conditions. Particle Swarm Opt... This paper describes the mitigation of harmonics in source and neutral current in three phase four wire system based on 4-leg shunt active power filter under balanced and unbalanced load conditions. Particle Swarm Optimization (PSO) and conventional Proportional Integral (PI) controller are used as control techniques to analyze the control performance of 4-leg shunt active power filter. The synchronous reference frame (SRF) method is used to extract reference current in 4-leg shunt active filter. The Hysteresis Current Controller (HCC) is used to generate gate pulses for Voltage Source Inverter (VSI) based 4-leg shunt active power filter. The proposed PSO technique gives less percentage of Total Harmonic Distortion (THD) value in source and neutral current and settling time of the DC capacitor voltage compared to conventional PI controller technique. The model of the proposed system performance was validated using MATLAB/Simulink environment. 展开更多
关键词 Hysteresis Current Controller Particle Swarm Optimization shunt active power filter SRF Method
下载PDF
A Novel Starting Impulse Suppression Method for Active Power Filter Based on Slowly Rising Curve
2
作者 Jianfeng Yang Yu Ding 《Energy Engineering》 EI 2021年第6期1839-1853,共15页
With the widespread application of power electronic equipment in the power grid,the harmonic problem of the power grid becomes more pronounced,reducing the efficiency of power production,transmission,and utilization,a... With the widespread application of power electronic equipment in the power grid,the harmonic problem of the power grid becomes more pronounced,reducing the efficiency of power production,transmission,and utilization,and interfering with the normal operation of the power grid.Based on the requirements of harmonic suppression and power system protection,a shunt active power filter(SAPF)is proposed as an effective harmonic suppression method.However,there are problems with impulse current and impulse voltage in the starting process of SAPF.Impulse current and impulse voltage cause the power grid and switchgear to bear greater current stress and voltage stress,which seriously affect the security and reliability of the power grid and may damage the switchgear.To effectively solve the problem of impulse current and impulse voltage,the starting process of SAPF is divided into the uncontrolled rectification stage and the transition stage.The mathematical model of the DC side of APF is established.The causes of impulse current and impulse voltage in the uncontrolled rectifier and transition phases are analyzed.By introducing voltage square,a new starting impulse suppression strategy of active power filter based on the slow rising curve is proposed,fundamentally solving the problems of impulse current and impulse voltage.Simulation results verify the effectiveness and feasibility of this method. 展开更多
关键词 shunt active power filter starting shock impulse current impulse voltage
下载PDF
Power Quality Comparative Analysis between UPF and SAPF
3
作者 Nicolae Badea Alexandru Dusa Nicu Roman 《Journal of Energy and Power Engineering》 2021年第4期117-127,共11页
This paper makes a technical analysis of the converter’s topologies that are conventionally employed in three-phase three-wire in increasing the power factor and harmonics eliminating,namely unit power factor(UPF)and... This paper makes a technical analysis of the converter’s topologies that are conventionally employed in three-phase three-wire in increasing the power factor and harmonics eliminating,namely unit power factor(UPF)and shunt active power filter(SAPF)and highlights the improvement of energy quality in the supply network.The paper highlights that the mathematical model of the three-phase PWM rectifier in the dq coordinate system is similar for both configurations.The structure of the control schemes of the two topologies for increasing the energy quality is similar by transformation of three-phase stationary coordinate system(a,b,c),to synchronous rotating(d,q)coordinate system that synchronously rotates with the fundamental voltage of the grid.Theoretical analysis and simulation results show that the control in synchronous rotating coordinate system has high power factor and low THDi for the both topologies. 展开更多
关键词 power quality unit power factor shunt active power filter energy efficiency.
下载PDF