This study investigated the feasibility of distance protection in extra-high voltage(EHV) networks. In long-distance transmission lines, the distributed parameter characteristic of the EHV network is obvious. When a f...This study investigated the feasibility of distance protection in extra-high voltage(EHV) networks. In long-distance transmission lines, the distributed parameter characteristic of the EHV network is obvious. When a fault occurs far away from the measurement site, the measured impedance might not be directly proportional to the fault distance, and the protection domain of distance protection will be decreased. The detailed theory inferred and proven in this paper reveals that this phenomenon is widespread in EHV transmission lines. The results indicate that the protection domain error is greatly reduced by the application of the shunt reactor. Overall, simulation results show that the proposed method is effective for impedance relay, considering different characteristics, different lengths of lines, and compensation degrees.展开更多
The high frequency transient recovery voltage caused by usually switching operation of the circuit breakers, used on shunt reactor switching, have become a noticeable problem recently. For extension the service life t...The high frequency transient recovery voltage caused by usually switching operation of the circuit breakers, used on shunt reactor switching, have become a noticeable problem recently. For extension the service life time and normal operation of the circuit breakers, a well modified maintenance strategy is proposed. The field testing and experimental measurement showed the maintenance strategy proposed had been proved effectively and adopted in Taiwan Power Company.展开更多
This paper analyzes the fundamental frequency impedance presents a novel transmission line pilot protection scheme characteristic of a thyristor controlled series capacitor (TCSC) and based on fault component integr...This paper analyzes the fundamental frequency impedance presents a novel transmission line pilot protection scheme characteristic of a thyristor controlled series capacitor (TCSC) and based on fault component integrated impedance (FCII) calculated for a transmission line with TCSC and controllable shunt reactor (CSR). The FCII is defined as the ratio of the sum of the fault component voltage phasors of a transmission line with TCSC and CSR to the sum of the fault component current phasors where all the phasors are determined at both line's terminals. It can be used to distinguish internal faults occurring on the line from external ones. If the fault is an external one the FCII reflects the line's capacitive impedance and has large value. If the fault is an internal one on the line the FCII reflects the impedance of the equivalent system and the line and is relatively small. The new pilot protection scheme can be easily set and has the fault phase selection ability and also it is not affected by the capacitive current and the fault transition resistance. It is not sensitive to compensation level and dynamics of TCSC and CSR. The effectiveness of the new scheme is validated against data obtained in ATP simulations and Northwest China 750 kV Project.展开更多
文摘This study investigated the feasibility of distance protection in extra-high voltage(EHV) networks. In long-distance transmission lines, the distributed parameter characteristic of the EHV network is obvious. When a fault occurs far away from the measurement site, the measured impedance might not be directly proportional to the fault distance, and the protection domain of distance protection will be decreased. The detailed theory inferred and proven in this paper reveals that this phenomenon is widespread in EHV transmission lines. The results indicate that the protection domain error is greatly reduced by the application of the shunt reactor. Overall, simulation results show that the proposed method is effective for impedance relay, considering different characteristics, different lengths of lines, and compensation degrees.
文摘The high frequency transient recovery voltage caused by usually switching operation of the circuit breakers, used on shunt reactor switching, have become a noticeable problem recently. For extension the service life time and normal operation of the circuit breakers, a well modified maintenance strategy is proposed. The field testing and experimental measurement showed the maintenance strategy proposed had been proved effectively and adopted in Taiwan Power Company.
基金supported by the National Natural Science Foundation of China (Grant Nos.50877061 and 51037005)
文摘This paper analyzes the fundamental frequency impedance presents a novel transmission line pilot protection scheme characteristic of a thyristor controlled series capacitor (TCSC) and based on fault component integrated impedance (FCII) calculated for a transmission line with TCSC and controllable shunt reactor (CSR). The FCII is defined as the ratio of the sum of the fault component voltage phasors of a transmission line with TCSC and CSR to the sum of the fault component current phasors where all the phasors are determined at both line's terminals. It can be used to distinguish internal faults occurring on the line from external ones. If the fault is an external one the FCII reflects the line's capacitive impedance and has large value. If the fault is an internal one on the line the FCII reflects the impedance of the equivalent system and the line and is relatively small. The new pilot protection scheme can be easily set and has the fault phase selection ability and also it is not affected by the capacitive current and the fault transition resistance. It is not sensitive to compensation level and dynamics of TCSC and CSR. The effectiveness of the new scheme is validated against data obtained in ATP simulations and Northwest China 750 kV Project.