期刊文献+
共找到2篇文章
< 1 >
每页显示 20 50 100
Monte Carlo simulation for performance evaluation of detector model with a monolithic LaBr_(3)(Ce)crystal and SiPM array forγradiation imaging 被引量:2
1
作者 Wei Lu Lei Wang +5 位作者 Yong Yuan Ting Zhang Ge Tang Ming-Zhe Liu Xian-Guo Tuo Jing Ning 《Nuclear Science and Techniques》 SCIE EI CAS CSCD 2022年第8期163-174,共12页
In recent years,LaBr_(3)(Ce)crystals and silicon photomultipliers(SiPMs)have been increasingly used in radiation imaging.This study involved the establishment of a detector model with a monolithic LaBr_(3)(Ce)crystal ... In recent years,LaBr_(3)(Ce)crystals and silicon photomultipliers(SiPMs)have been increasingly used in radiation imaging.This study involved the establishment of a detector model with a monolithic LaBr_(3)(Ce)crystal and SiPM array forγ-radiation imaging on the GEANT4 platform.The optical process included in the detector model was defined by key parameters,such as the emission spectrum,scintillation yield,and intrinsic resolution of the LaBr_(3):5%Ce crystal,as well as the detection efficiency of the SiPM array.The response of the detector model to^(57)Co flooded field irradiation was simulated and evaluated.The radiation images generated by the detector model exhibited a compression effect that was very close to that on images acquired by the physical detector.The spatial resolution of the simulated detector closely approximates that of the physical experiment.A detector model without the optical process was also established for comparison with a detector using the optical process.Both were used in a near-field modified uniform redundant array(MURA)imaging system to acquire images of a point source and a ring source of^(57)Co at the center of the field-of-view of the imaging system.The spatial resolution and signal-to-noise ratio of the images that were reconstructed using the two detector models were determined and compared.Compared with the detector model without optical processes,although the images from the proposed detector model have slightly inferior signal-to-noise ratios and more artifacts,they are more consistent with the reconstructed versions of images acquired in real physical experiments.The results confirm that the detector model can be used to design aγ-radiation imaging detector and to develop an imaging algorithm that can significantly shorten the development time and reduce the cost. 展开更多
关键词 Scintillation photons Monte Carlo sipm array Spatial resolution Monolithic LaBr_(3)(Ce)crystal
下载PDF
The design and performance of GRD onboard the GECAM satellite 被引量:1
2
作者 Z.H.An X.L.Sun +48 位作者 D.L.Zhang S.Yang X.Q.Li X.Y.Wen K.Gong X.H.Liang X.J.Liu Y.Q.Liu Y.G.Li S.L.Xiong Y.B.Xu Fan Zhang X.Y.Zhao C.Cai Z.Chang G.Chen C.Chen Y.Y.Du P.Y.Feng M.Gao R.Gao D.Y.Guo J.J.He D.J.Hou C.Y.Li G.Li L.Li X.F.Li M.S.Li F.J.Lu H.Lu B.Meng W.X.Peng F.Shi H.Wang J.Z.Wang Y.S.Wang H.Z.Wang X.Wen S.Xiao Y.P.Xu J.W.Yang Q.B.Yi S.N.Zhang C.Y.Zhang C.M.Zhang Fei Zhang Y.Zhao X.Zhou 《Radiation Detection Technology and Methods》 CSCD 2022年第1期43-52,共10页
Background Each GECAM satellite payload contains 25 gamma-ray detectors(GRDs),which can detect gamma-rays and particles and can roughly localize the Gamma-Ray Bursts(GRBs).GRD was designed using lanthanum bromide(LaBr... Background Each GECAM satellite payload contains 25 gamma-ray detectors(GRDs),which can detect gamma-rays and particles and can roughly localize the Gamma-Ray Bursts(GRBs).GRD was designed using lanthanum bromide(LaBr3)crystal as the sensitive material with the rear end coupled with silicon photomultiplier(SiPM)array for readout.Purpose In aerospace engineering design of GRD,there are many key points to be studied.In this paper,we present the specific design scheme of GRD,the assembly and the performance test results of detectors.Methods Based on Monte Carlo simulation and experimental test results,the specific schematic design and assembling process of GRD were optimized.After being fully assembled,the GRDs were conducted performance tests by using radioactive source and also conducted random vibration tests.Result and conclusion The test results show that all satellite-borne GRDs have energy resolution<16%at 59.5 keV,meeting requirements of satellite in scientific performance.The random vibration test shows that GRD can maintain in a stable performance,which meets the requirement of spatial application. 展开更多
关键词 Lanthanum bromide scintillator sipm array GECAM Gamma-ray detector Energy resolution
原文传递
上一页 1 下一页 到第